Elliott A. Palmer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Elliott A. Palmer has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin Roger Buckley
Department of Chemistry, Loughborough University, Loughborough, Leicestershire, LE11 3TU, UK
1 shared publication C. Aldcroft
Advion Ltd, Kao Hockham Building, Edinburgh Way, Harlow, CM20 2NQ, UK
1 shared publicationCarlos Castelló Beltrán
Department of Chemistry, School of Science, Loughborough University, Leicestershire, LE11 3TU, UK.
1 shared publication- Colin S. Creaser
Centre for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, Leicestershire LE11 3TU, United Kingdom
1 shared publication - Felipe Iza
Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University 2 , Ashby Road, Loughborough, Leicestershire LE11 3TU, United Kingdom
1 shared publication - Helen J. Cooper
School of Biosciences University of Birmingham Edgbaston Birmingham UK
1 shared publication
Latest Publications
- 16 October 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (22) , 14306-14313
Investigation of the 12-Month Stability of Dried Blood and Urine Spots Applying Untargeted UHPLC-MS Metabolomic Assays
The use of dried blood spot (DBS) and dried urine spot (DUS) samples represents an attractive opportunity for researchers in biomedical metabolomics to collect whole blood and urine samples in the absence of a processing laboratory and so to al-low collection in remote areas or in longitudinal studies away from the clinic. The 12-month stability of the thousands of metabolites present in these biofluids and the applicability of DBS and DUS samples for untargeted metabolomics applica-tions has not previously been investigated in detail and compared to blood and urine samples. Here, the 12-month stability of DBS and DUS at different storage temperatures (-20°C, +4°C and +21°C) have been compared to plasma and urine bio-fluids stored at the same storage temperatures and time. Samples were analysed applying complementary HILIC and C18 reversed-phase UHPLC-MS untargeted metabolomic assays. Results show that metabolites demonstrate increased stability in DBS and DUS compared to whole blood and urine at all storage temperatures and times. DBS and DUS stored at +21°C are stable for up to 4 weeks but are not stable over a one year period. DBS and DUS showed good stability when stored at -20°C for one year. We recommend that DBS and DUS samples are collected and transported within 28 days at room tem-perature and are stored for longer periods of time at -20°C or -80°C. The metabolomes of DUS samples and urine were very similar but the metabolome of DBS included additional metabolites not detected in plasma and therefore proposed to be released from cells in whole blood.
- 16 October 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (22) , 14306-14313
Investigation of the 12-Month Stability of Dried Blood and Urine Spots Applying Untargeted UHPLC-MS Metabolomic Assays
The use of dried blood spot (DBS) and dried urine spot (DUS) samples represents an attractive opportunity for researchers in biomedical metabolomics to collect whole blood and urine samples in the absence of a processing laboratory and so to al-low collection in remote areas or in longitudinal studies away from the clinic. The 12-month stability of the thousands of metabolites present in these biofluids and the applicability of DBS and DUS samples for untargeted metabolomics applica-tions has not previously been investigated in detail and compared to blood and urine samples. Here, the 12-month stability of DBS and DUS at different storage temperatures (-20°C, +4°C and +21°C) have been compared to plasma and urine bio-fluids stored at the same storage temperatures and time. Samples were analysed applying complementary HILIC and C18 reversed-phase UHPLC-MS untargeted metabolomic assays. Results show that metabolites demonstrate increased stability in DBS and DUS compared to whole blood and urine at all storage temperatures and times. DBS and DUS stored at +21°C are stable for up to 4 weeks but are not stable over a one year period. DBS and DUS showed good stability when stored at -20°C for one year. We recommend that DBS and DUS samples are collected and transported within 28 days at room tem-perature and are stored for longer periods of time at -20°C or -80°C. The metabolomes of DUS samples and urine were very similar but the metabolome of DBS included additional metabolites not detected in plasma and therefore proposed to be released from cells in whole blood.
- Open Access
- 1 December 2018
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1037, 301-315
Comparison of modified Matyash method to conventional solvent systems for polar metabolite and lipid extractions
- 1 December 2018
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1037, 301-315
Open AccessComparison of modified Matyash method to conventional solvent systems for polar metabolite and lipid extractions
- Open Access
- 30 August 2017
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 31 (22) , 1947-1956
Direct analysis of volatile organic compounds in foods by headspace extraction atmospheric pressure chemical ionisation mass spectrometry
Rationale: The rapid screening of volatile organic compounds (VOCs) by direct analysis has potential applications in the areas of food and flavour science. Currently, the technique of choice for VOC analysis is gas chromatography/mass spectrometry (GC/MS). However, the long chromatographic run times and elaborate sample preparation associated with this technique have led a movement towards direct analysis techniques, such as selected ion flow tube mass spectrometry (SIFT‐MS), proton transfer reaction mass spectrometry (PTR‐MS) and electronic noses. The work presented here describes the design and construction of a Venturi jet‐pump‐based modification for a compact mass spectrometer which enables the direct introduction of volatiles for qualitative and quantitative analysis. Methods: Volatile organic compounds were extracted from the headspace of heated vials into the atmospheric pressure chemical ionization source of a quadrupole mass spectrometer using a Venturi pump. Samples were analysed directly with no prior sample preparation. Principal component analysis (PCA) was used to differentiate between different classes of samples. Results: The interface is shown to be able to routinely detect problem analytes such as fatty acids and biogenic amines without the requirement of a derivatisation step, and is shown to be able to discriminate between four different varieties of cheese with good intra and inter‐day reproducibility using an unsupervised PCA model. Quantitative analysis is demonstrated using indole standards with limits of detection and quantification of 0.395 μg/mL and 1.316 μg/mL, respectively. Conclusions: The described methodology can routinely detect highly reactive analytes such as volatile fatty acids and diamines without the need for a derivatisation step or lengthy chromatographic separations. The capability of the system was demonstrated by discriminating between different varieties of cheese and monitoring the spoilage of meats.
- 30 August 2017
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 31 (22) , 1947-1956
Open AccessDirect analysis of volatile organic compounds in foods by headspace extraction atmospheric pressure chemical ionisation mass spectrometry
Rationale: The rapid screening of volatile organic compounds (VOCs) by direct analysis has potential applications in the areas of food and flavour science. Currently, the technique of choice for VOC analysis is gas chromatography/mass spectrometry (GC/MS). However, the long chromatographic run times and elaborate sample preparation associated with this technique have led a movement towards direct analysis techniques, such as selected ion flow tube mass spectrometry (SIFT‐MS), proton transfer reaction mass spectrometry (PTR‐MS) and electronic noses. The work presented here describes the design and construction of a Venturi jet‐pump‐based modification for a compact mass spectrometer which enables the direct introduction of volatiles for qualitative and quantitative analysis. Methods: Volatile organic compounds were extracted from the headspace of heated vials into the atmospheric pressure chemical ionization source of a quadrupole mass spectrometer using a Venturi pump. Samples were analysed directly with no prior sample preparation. Principal component analysis (PCA) was used to differentiate between different classes of samples. Results: The interface is shown to be able to routinely detect problem analytes such as fatty acids and biogenic amines without the requirement of a derivatisation step, and is shown to be able to discriminate between four different varieties of cheese with good intra and inter‐day reproducibility using an unsupervised PCA model. Quantitative analysis is demonstrated using indole standards with limits of detection and quantification of 0.395 μg/mL and 1.316 μg/mL, respectively. Conclusions: The described methodology can routinely detect highly reactive analytes such as volatile fatty acids and diamines without the need for a derivatisation step or lengthy chromatographic separations. The capability of the system was demonstrated by discriminating between different varieties of cheese and monitoring the spoilage of meats.
- Open Access
- 3 December 2014
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 51 (9) , 1579-1582
Virtues and limitations of Pittsburgh green for ozone detection
A recently proposed 2′,7′-dichlorofluorescein (DCF)-derived fluorescent probe for the detection of ozone shows good selectivity against a number of reactive oxygen species and good pH stability for biological and environmental applications. It is found, however, that over oxidation of the fluorescent product (Pittsburgh green) can occur. This could render quantitative measurements inaccurate due to a reduction in fluorescence and overlapping fluorescence signals from over oxidation by-products and it requires careful experimental design. Although difficult to assess by fluorescence measurements, the over oxidation can be conveniently monitored by 1H NMR spectroscopy.
- 3 December 2014
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 51 (9) , 1579-1582
Open AccessVirtues and limitations of Pittsburgh green for ozone detection
A recently proposed 2′,7′-dichlorofluorescein (DCF)-derived fluorescent probe for the detection of ozone shows good selectivity against a number of reactive oxygen species and good pH stability for biological and environmental applications. It is found, however, that over oxidation of the fluorescent product (Pittsburgh green) can occur. This could render quantitative measurements inaccurate due to a reduction in fluorescence and overlapping fluorescence signals from over oxidation by-products and it requires careful experimental design. Although difficult to assess by fluorescence measurements, the over oxidation can be conveniently monitored by 1H NMR spectroscopy.