TMThomas J. Marini

Thomas J. Marini

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thomas J. Marini has a total of 123 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Where no sound wave has gone before: first high-resolution transcranial images of the brain using ultrasound computed tomography

    by Thomas J. Marini, Trevor Mitcham, Rehman Ali, Israel Owolabi, Victoria Nketia, Matthew T. Bender, Gurkirat Kohli, Santiago Mendoza-Ayus, Marissa Lake, Melanie Singh, et al.

  • Transcranial ultrasound tomography for neonatal brain imaging: A feasibility study

    by Gaofei Jin, Hossein Raeis, Thomas J. Marini, Joseph M. Bliss, Mohammad Mehrmohammadi

  • Open Access

    New lung ultrasound system for rapid triage of pulmonary disease without a radiologist or sonographer

    by Thomas J. Marini, Ajeesh Ajayan Nayaruparambil, Timothy M. Baran, Thapasya Murali, Stephen Drury, Yu T. Zhao, Katherine Kaproth-Joslin, Robert Ambrosini, Sean Cleary, Stan L. Weiss, et al.

    Most people in the world lack access to medical imaging including for assessment of pulmonary disease. We sought to improve access to pulmonary imaging by developing a rapid automated system for triage of pulmonary disease using lung ultrasound requiring neither a radiologist nor experienced sonographer utilizing volume sweep imaging (VSI) and artificial intelligence (AI). We conducted a retrospective study of lung ultrasound VSI data collected from May 2019 to January 2020. AI analysis utilizing a convolutional neural network and random forest-based machine learning classifier was performed on 70 normal lung ultrasound VSI video clips and 49 abnormal lung ultrasound VSI video clips obtained by individuals without prior ultrasound experience. The accuracy of the AI was assessed for the ability to distinguish between normal and abnormal lung ultrasound video clips. Among test VSI clips (n = 36 clips), AI achieved 91.7% accuracy, 85.7% sensitivity, 95.5% specificity, and an F1 score of 0.89 for an abnormal lung ultrasound VSI clip. Among test subjects (n = 20) from which these clips were obtained, 90.0% accuracy, 87.5% sensitivity, 91.7% specificity, and an F1 score of 0.88 were achieved. Lung ultrasound VSI integrated with AI shows potential to provide preliminary triage of pulmonary disease allowing a system for rapid automatic triage of pulmonary disease requiring neither a radiologist nor sonographer.

  • Open Access

    Sustainable volume sweep imaging lung teleultrasound in Peru: Public health perspectives from a new frontier in expanding access to imaging

    by Thomas J. Marini, Benjamin Castaneda, Malavika Satheesh, Yu T. Zhao, C. Mahony Reátegui-Rivera, Walter Sifuentes, Timothy M. Baran, Katherine A. Kaproth-Joslin, Robert Ambrosini, Gloria Rios-Mayhua, et al.

    Background: Pulmonary disease is a common cause of morbidity and mortality, but the majority of the people in the world lack access to diagnostic imaging for its assessment. We conducted an implementation assessment of a potentially sustainable and cost-effective model for delivery of volume sweep imaging (VSI) lung teleultrasound in Peru. This model allows image acquisition by individuals without prior ultrasound experience after only a few hours of training.Methods: Lung teleultrasound was implemented at 5 sites in rural Peru after a few hours of installation and staff training. Patients were offered free lung VSI teleultrasound examination for concerns of respiratory illness or research purposes. After ultrasound examination, patients were surveyed regarding their experience. Health staff and members of the implementation team also participated in separate interviews detailing their views of the teleultrasound system which were systematically analyzed for key themes.Results: Patients and staff rated their experience with lung teleultrasound as overwhelmingly positive. The lung teleultrasound system was viewed as a potential way to improve access to imaging and the health of rural communities. Detailed interviews with the implementation team revealed obstacles to implementation important for consideration such as gaps in lung ultrasound understanding.Conclusions: Lung VSI teleultrasound was successfully deployed to 5 health centers in rural Peru. Implementation assessment revealed enthusiasm for the system among members of the community along with important areas of consideration for future teleultrasound deployment. This system offers a potential means to increase access to imaging for pulmonary illness and improve the health of the global community.


  • Open Access

    No sonographer, no radiologist: Assessing accuracy of artificial intelligence on breast ultrasound volume sweep imaging scans

    by Thomas J Marini, Benjamin Castaneda, Kevin Parker, Timothy M Baran, Stefano Romero, Radha Iyer, Yu T Zhao, Zaegyoo Hah, Moon Ho Park, Galen Brennan, et al.

    Breast ultrasound provides a first-line evaluation for breast masses, but the majority of the world lacks access to any form of diagnostic imaging. In this pilot study, we assessed the combination of artificial intelligence (Samsung S-Detect for Breast) with volume sweep imaging (VSI) ultrasound scans to evaluate the possibility of inexpensive, fully automated breast ultrasound acquisition and preliminary interpretation without an experienced sonographer or radiologist. This study was conducted using examinations from a curated data set from a previously published clinical study of breast VSI. Examinations in this data set were obtained by medical students without prior ultrasound experience who performed VSI using a portable Butterfly iQ ultrasound probe. Standard of care ultrasound exams were performed concurrently by an experienced sonographer using a high-end ultrasound machine. Expert-selected VSI images and standard of care images were input into S-Detect which output mass features and classification as “possibly benign” and “possibly malignant.” Subsequent comparison of the S-Detect VSI report was made between 1) the standard of care ultrasound report by an expert radiologist, 2) the standard of care ultrasound S-Detect report, 3) the VSI report by an expert radiologist, and 4) the pathological diagnosis. There were 115 masses analyzed by S-Detect from the curated data set. There was substantial agreement of the S-Detect interpretation of VSI among cancers, cysts, fibroadenomas, and lipomas to the expert standard of care ultrasound report (Cohen’s κ = 0.73 (0.57–0.9 95% CI), p<0.0001), the standard of care ultrasound S-Detect interpretation (Cohen’s κ = 0.79 (0.65–0.94 95% CI), p<0.0001), the expert VSI ultrasound report (Cohen’s κ = 0.73 (0.57–0.9 95% CI), p<0.0001), and the pathological diagnosis (Cohen’s κ = 0.80 (0.64–0.95 95% CI), p<0.0001). All pathologically proven cancers (n = 20) were designated as “possibly malignant” by S-Detect with a sensitivity of 100% and specificity of 86%. Integration of artificial intelligence and VSI could allow both acquisition and interpretation of ultrasound images without a sonographer and radiologist. This approach holds potential for increasing access to ultrasound imaging and therefore improving outcomes related to breast cancer in low- and middle- income countries.


  • Open Access

    Volume sweep imaging lung teleultrasound for detection of COVID-19 in Peru: a multicentre pilot study

    by Thomas J Marini, Katherine Kaproth-Joslin, Robert Ambrosini, Timothy M Baran, Ann M Dozier, Yu T Zhao, Malavika Satheesh, Christian Mahony Reátegui-Rivera, Walter Sifuentes, Gloria Rios-Mayhua, et al.

    Objectives Pulmonary disease is a significant cause of morbidity and mortality in adults and children, but most of the world lacks diagnostic imaging for its assessment. Lung ultrasound is a portable, low-cost, and highly accurate imaging modality for assessment of pulmonary pathology including pneumonia, but its deployment is limited secondary to a lack of trained sonographers. In this study, we piloted a low-cost lung teleultrasound system in rural Peru during the COVID-19 pandemic using lung ultrasound volume sweep imaging (VSI) that can be operated by an individual without prior ultrasound training circumventing many obstacles to ultrasound deployment. Design Pilot study. Setting Study activities took place in five health centres in rural Peru. Participants There were 213 participants presenting to rural health clinics. Interventions Individuals without prior ultrasound experience in rural Peru underwent brief training on how to use the teleultrasound system and perform lung ultrasound VSI. Subsequently, patients attending clinic were scanned by these previously ultrasound-naïve operators with the teleultrasound system. Primary and secondary outcome measures Radiologists examined the ultrasound imaging to assess its diagnostic value and identify any pathology. A random subset of 20% of the scans were analysed for inter-reader reliability. Results Lung VSI teleultrasound examinations underwent detailed analysis by two cardiothoracic attending radiologists. Of the examinations, 202 were rated of diagnostic image quality (94.8%, 95% CI 90.9% to 97.4%). There was 91% agreement between radiologists on lung ultrasound interpretation among a 20% sample of all examinations (κ=0.76, 95% CI 0.53 to 0.98). Radiologists were able to identify sequelae of COVID-19 with the predominant finding being B-lines. Conclusion Lung VSI teleultrasound performed by individuals without prior training allowed diagnostic imaging of the lungs and identification of sequelae of COVID-19 infection. Deployment of lung VSI teleultrasound holds potential as a low-cost means to improve access to imaging around the world.


  • Open Access

    Breast Ultrasound Volume Sweep Imaging: A New Horizon in Expanding Imaging Access for Breast Cancer Detection

    by Thomas J. Marini, Benjamin Castaneda, Radha Iyer, Timothy M. Baran, Omar Nemer, Ann M. Dozier, Kevin J. Parker, Yu Zhao, William Serratelli, Gregory Matos, et al.

    Objective The majority of people in the world lack basic access to breast diagnostic imaging resulting in delay to diagnosis of breast cancer. In this study, we tested a volume sweep imaging (VSI) ultrasound protocol for evaluation of palpable breast lumps that can be performed by operators after minimal training without prior ultrasound experience as a means to increase accessibility to breast ultrasound. Methods Medical students without prior ultrasound experience were trained for less than 2 hours on the VSI breast ultrasound protocol. Patients presenting with palpable breast lumps for standard of care ultrasound examination were scanned by a trained medical student with the VSI protocol using a Butterfly iQ handheld ultrasound probe. Video clips of the VSI scan imaging were later interpreted by an attending breast imager. Results of VSI scan interpretation were compared to the same-day standard of care ultrasound examination. Results Medical students scanned 170 palpable lumps with the VSI protocol. There was 97% sensitivity and 100% specificity for a breast mass on VSI corresponding to 97.6% agreement with standard of care (Cohen's kappa = 0.95, P < .0001). There was a detection rate of 100% for all cancer presenting as a sonographic mass. High agreement for mass characteristics between VSI and standard of care was observed, including 87% agreement on Breast Imaging-Reporting and Data System assessments (Cohen's kappa = 0.82, P < .0001). Conclusions Breast ultrasound VSI for palpable lumps offers a promising means to increase access to diagnostic imaging in underserved areas. This approach could decrease delay to diagnosis for breast cancer, potentially improving morbidity and mortality.


  • Open Access

    No sonographer, no radiologist: New system for automatic prenatal detection of fetal biometry, fetal presentation, and placental location

    by Junior Arroyo, Thomas J. Marini, Ana C. Saavedra, Marika Toscano, Timothy M. Baran, Kathryn Drennan, Ann Dozier, Yu Tina Zhao, Miguel Egoavil, Lorena Tamayo, et al.

    Ultrasound imaging is a vital component of high-quality Obstetric care. In rural and under-resourced communities, the scarcity of ultrasound imaging results in a considerable gap in the healthcare of pregnant mothers. To increase access to ultrasound in these communities, we developed a new automated diagnostic framework operated without an experienced sonographer or interpreting provider for assessment of fetal biometric measurements, fetal presentation, and placental position. This approach involves the use of a standardized volume sweep imaging (VSI) protocol based solely on external body landmarks to obtain imaging without an experienced sonographer and application of a deep learning algorithm (U-Net) for diagnostic assessment without a radiologist. Obstetric VSI ultrasound examinations were performed in Peru by an ultrasound operator with no previous ultrasound experience who underwent 8 hours of training on a standard protocol. The U-Net was trained to automatically segment the fetal head and placental location from the VSI ultrasound acquisitions to subsequently evaluate fetal biometry, fetal presentation, and placental position. In comparison to diagnostic interpretation of VSI acquisitions by a specialist, the U-Net model showed 100% agreement for fetal presentation (Cohen’s κ 1 (p<0.0001)) and 76.7% agreement for placental location (Cohen’s κ 0.59 (p<0.0001)). This corresponded to 100% sensitivity and specificity for fetal presentation and 87.5% sensitivity and 85.7% specificity for anterior placental location. The method also achieved a low relative error of 5.6% for biparietal diameter and 7.9% for head circumference. Biometry measurements corresponded to estimated gestational age within 2 weeks of those assigned by standard of care examination with up to 89% accuracy. This system could be deployed in rural and underserved areas to provide vital information about a pregnancy without a trained sonographer or interpreting provider. The resulting increased access to ultrasound imaging and diagnosis could improve disparities in healthcare delivery in under-resourced areas.


  • Open Access

    Lung ultrasound volume sweep imaging for respiratory illness: a new horizon in expanding imaging access

    by Thomas J Marini, Justin M Weis, Timothy M Baran, Jonah Kan, Steven Meng, Alex Yeo, Yu T Zhao, Robert Ambrosini, Sean Cleary, Deborah Rubens, et al.

    Background Respiratory illness is a leading cause of morbidity in adults and the number one cause of mortality in children, yet billions of people lack access to medical imaging to assist in its diagnosis. Although ultrasound is highly sensitive and specific for respiratory illness such as pneumonia, its deployment is limited by a lack of sonographers. As a solution, we tested a standardised lung ultrasound volume sweep imaging (VSI) protocol based solely on external body landmarks performed by individuals without prior ultrasound experience after brief training. Each step in the VSI protocol is saved as a video clip for later interpretation by a specialist. Methods Dyspneic hospitalised patients were scanned by ultrasound naive operators after 2 hours of training using the lung ultrasound VSI protocol. Separate blinded readers interpreted both lung ultrasound VSI examinations and standard of care chest radiographs to ascertain the diagnostic value of lung VSI considering chest X-ray as the reference standard. Comparison to clinical diagnosis as documented in the medical record and CT (when available) were also performed. Readers offered a final interpretation of normal, abnormal, or indeterminate/borderline for each VSI examination, chest X-ray, and CT. Results Operators scanned 102 subjects (0–89 years old) for analysis. Lung VSI showed a sensitivity of 93% and a specificity of 91% for an abnormal chest X-ray and a sensitivity of 100% and a specificity of 93% for a clinical diagnosis of pneumonia. When any cases with an indeterminate rating on chest X-ray or ultrasound were excluded (n=38), VSI lung ultrasound showed 92% agreement with chest X-ray (Cohen’s κ 0.83 (0.68 to 0.97, pConclusion Lung VSI performed by previously inexperienced ultrasound operators after brief training showed excellent agreement with chest X-ray and high sensitivity and specificity for a clinical diagnosis of pneumonia. Blinded readers were able to identify other respiratory diseases including pulmonary oedema and pleural effusion. Deployment of lung VSI could benefit the health of the global community.


  • Open Access

    Cone-Beam Breast Computed Tomography: Time for a New Paradigm in Breast Imaging

    by Avice M. O'Connell, Thomas J. Marini, Daniel T. Kawakyu-O'Connor

    It is time to reconsider how we image the breast. Although the breast is a 3D structure, we have traditionally used 2D mammography to perform screening and diagnostic imaging. Mammography has been continuously modified and improved, most recently with tomosynthesis and contrast mammography, but it is still using modifications of compression 2D mammography. It is time to consider 3D imaging for this 3D structure. Cone-beam breast computed tomography (CBBCT) is a revolutionary modality that will assist in overcoming the limitations of current imaging for dense breast tissue and overlapping structures. It also allows easy administration of contrast material for functional imaging. With a radiation dose on par with diagnostic mammography, rapid 10 s acquisition, no breast compression, and true high-resolution isotropic imaging, CBBCT has the potential to usher in a new era in breast imaging. These advantages could translate into lower morbidity and mortality from breast cancer.