Feng C. Lai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Feng C. Lai has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
C. C. Ngo
University of North Dakota, Grand Forks, ND
8 shared publicationsN. M. Brown
University of Technology, Kingston, Jamaica
3 shared publicationsS.-C. Lin
3 shared publications- Yilma T. Birhane
Mechanical and Industrial Engineering, Addis Ababa University, 37602 Addis Ababa, Oromia, Ethiopia
3 shared publications A. K. M. Monayem H. Mazumder
Saginaw Valley State University, University Center, Michigan 48710
2 shared publicationsJ.C. Leong
2 shared publications
Latest Publications
- 25 May 2026
- Published by Elsevier in Journal of Electrostatics
- Vol. 141
Parametric study on the performance of dielectric barrier discharge plasma actuator
- 25 May 2026
- Published by Elsevier in Journal of Electrostatics
- Vol. 141
Parametric study on the performance of dielectric barrier discharge plasma actuator
- 16 February 2025
- Published by Elsevier in Journal of Electrostatics
- Vol. 134
Evaluation of swirl-flow generation by two-stage EHD pumps with three configurations using anchored electrodes
- 16 February 2025
- Published by Elsevier in Journal of Electrostatics
- Vol. 134
Evaluation of swirl-flow generation by two-stage EHD pumps with three configurations using anchored electrodes
- 26 May 2024
- Published by Elsevier in Journal of Electrostatics
- Vol. 129
EHD gas pump as a cooling device for electronic components in a horizontal channel
- 26 May 2024
- Published by Elsevier in Journal of Electrostatics
- Vol. 129
EHD gas pump as a cooling device for electronic components in a horizontal channel
- 13 February 2024
- Published by Elsevier in Journal of Electrostatics
- Vol. 128
Enhancement of flow mixing using a two-stage EHD gas pump with electrodes anchored at one corner of channel
- 13 February 2024
- Published by Elsevier in Journal of Electrostatics
- Vol. 128
Enhancement of flow mixing using a two-stage EHD gas pump with electrodes anchored at one corner of channel
- 3 February 2024
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 38 (3) , 1-8
On Electronics Cooling Using an Electrohydrodynamic Gas Pump with Aligned Electrodes
- 3 February 2024
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 38 (3) , 1-8
On Electronics Cooling Using an Electrohydrodynamic Gas Pump with Aligned Electrodes
- 1 October 2023
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 37 (4) , 761-770
Flows Generated by Electrohydrodynamic Gas Pumps with Different Electrode Orientations
Numerical simulations have been performed to examine the flows inside a square channel produced by a two-stage electrohydrodynamic (EHD) gas pump with two electrode arrangements. The EHD pump has a pair of seven emitting electrodes flush mounted on two parallel walls at each stage. The flush-mounted electrodes produce corona wind similar to a wall jet that is mainly responsible for flow delivery. The pump is operated by a combination of three different voltages (24, 26, and 28 kV) for performance improvement. Because flow visualization is very challenging to implement in experimental study of EHD flows, very few results are available in the literature. As such, this study is specifically aimed at providing additional insight to the flowfield inside the channel through visualization of the numerical results obtained. Also, the overall effectiveness of the EHD gas pump is evaluated by the volume flow rate delivered as well as its power efficiency. It has been found that the power efficiency for the EHD pumps considered is higher than the conventional fans/pumps. Thus, they have a great potential for applications in thermal management. Particularly, they can be more energy efficient when they are operated by uneven applied voltages.
- 1 October 2023
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 37 (4) , 761-770
Flows Generated by Electrohydrodynamic Gas Pumps with Different Electrode Orientations
Numerical simulations have been performed to examine the flows inside a square channel produced by a two-stage electrohydrodynamic (EHD) gas pump with two electrode arrangements. The EHD pump has a pair of seven emitting electrodes flush mounted on two parallel walls at each stage. The flush-mounted electrodes produce corona wind similar to a wall jet that is mainly responsible for flow delivery. The pump is operated by a combination of three different voltages (24, 26, and 28 kV) for performance improvement. Because flow visualization is very challenging to implement in experimental study of EHD flows, very few results are available in the literature. As such, this study is specifically aimed at providing additional insight to the flowfield inside the channel through visualization of the numerical results obtained. Also, the overall effectiveness of the EHD gas pump is evaluated by the volume flow rate delivered as well as its power efficiency. It has been found that the power efficiency for the EHD pumps considered is higher than the conventional fans/pumps. Thus, they have a great potential for applications in thermal management. Particularly, they can be more energy efficient when they are operated by uneven applied voltages.
- 12 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (4) , 5292-5300
A Two-Stage EHD Gas Pump in a Square Channel With Electrodes Mounted on Two Opposite Facing Walls
This article explores ways to further improve the performance of an electrohydrodynamic (EHD) gas pump operating in a square channel. To this end, the present pump uses electrode assemblies that are grouped in two and are mounted on the two opposite walls facing each other. The emitting electrodes are flush mounted on the channel walls so that the air flow produced is similar to that of a wall jet. The electrode configuration with three emitting electrodes on each wall is investigated for its effectiveness in enhancing the volume flow rate as well as reducing the power requirement. The results obtained are compared with those reported in the previous studies with various electrode configurations to determine which performs the best. Through the performance assessment of various pump designs, the present results have provided important information for practical applications of EHD technology.
- 12 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (4) , 5292-5300
A Two-Stage EHD Gas Pump in a Square Channel With Electrodes Mounted on Two Opposite Facing Walls
This article explores ways to further improve the performance of an electrohydrodynamic (EHD) gas pump operating in a square channel. To this end, the present pump uses electrode assemblies that are grouped in two and are mounted on the two opposite walls facing each other. The emitting electrodes are flush mounted on the channel walls so that the air flow produced is similar to that of a wall jet. The electrode configuration with three emitting electrodes on each wall is investigated for its effectiveness in enhancing the volume flow rate as well as reducing the power requirement. The results obtained are compared with those reported in the previous studies with various electrode configurations to determine which performs the best. Through the performance assessment of various pump designs, the present results have provided important information for practical applications of EHD technology.
- 31 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (2) , 2444-2451
Numerical Study of Corona Jet Produced From a Circular Tube Fitted With a Nozzle
Numerical study on the flow characteristics of a plasma jet, which is produced from a needle electrode positioned at the centerline of a circular tube with a grounded stainless-steel nozzle attached at one end of the tube, is presented. This study is particularly aimed at providing additional insight to the flow field inside the tube assembly through visualization of the numerical results obtained. Since flow visualization is very challenging to implement in experimental study of electrohydrodynamics (EHD), and thus no result was available from the previous study. As such, the present results become very useful in understanding the flow inside the nozzle. To this end, six nozzles with two diameter ratios and three taper angles are evaluated for their effectiveness in accelerating the jet produced by corona discharge with positive polarity. The numerical results have confirmed the findings from the previous study that a nozzle with a smaller diameter ratio does not always perform the best in accelerating the flow or producing the maximum volume flow rate due to the flow restructuring inside the nozzle. In addition, the results show that taper angle can further amplify the effect produced by the diameter ratio.
- 31 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (2) , 2444-2451
Numerical Study of Corona Jet Produced From a Circular Tube Fitted With a Nozzle
Numerical study on the flow characteristics of a plasma jet, which is produced from a needle electrode positioned at the centerline of a circular tube with a grounded stainless-steel nozzle attached at one end of the tube, is presented. This study is particularly aimed at providing additional insight to the flow field inside the tube assembly through visualization of the numerical results obtained. Since flow visualization is very challenging to implement in experimental study of electrohydrodynamics (EHD), and thus no result was available from the previous study. As such, the present results become very useful in understanding the flow inside the nozzle. To this end, six nozzles with two diameter ratios and three taper angles are evaluated for their effectiveness in accelerating the jet produced by corona discharge with positive polarity. The numerical results have confirmed the findings from the previous study that a nozzle with a smaller diameter ratio does not always perform the best in accelerating the flow or producing the maximum volume flow rate due to the flow restructuring inside the nozzle. In addition, the results show that taper angle can further amplify the effect produced by the diameter ratio.
- 27 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (3) , 3052-3060
Performance of a Two-Stage EHD Gas Pump in a Circular Pipe Operating at Uneven Applied Voltages
The performance of a two-stage electrohydro-dynamic (EHD) gas pump in a circular tube has been investigated for operating conditions in which each stage is charged at a different voltage. The main objective of the study is to examine the characteristics of resulting flow as well as the efficient use of energy in sustaining and improving the volume flow rate produced by a single-stage pump over a greater distance. To this end, two different sizes of tube are employed (61.8 mm and 127.8 mm in diameter). Each stage uses eight emitting electrodes flush mounted on the tube wall. In addition, two electrode configurations, aligned and offset, with fixed electrode spacing have been considered. The electrodes at both stages are charged at voltages in positive polarity from 18 kV to 22 kV. The velocity profile and volume flow rate delivered are compared with those produced by the same pump operating at even voltages to provide additional insight to the problem. The results thus obtained have important implications for practical use of EHD gas pump.
- 27 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (3) , 3052-3060
Performance of a Two-Stage EHD Gas Pump in a Circular Pipe Operating at Uneven Applied Voltages
The performance of a two-stage electrohydro-dynamic (EHD) gas pump in a circular tube has been investigated for operating conditions in which each stage is charged at a different voltage. The main objective of the study is to examine the characteristics of resulting flow as well as the efficient use of energy in sustaining and improving the volume flow rate produced by a single-stage pump over a greater distance. To this end, two different sizes of tube are employed (61.8 mm and 127.8 mm in diameter). Each stage uses eight emitting electrodes flush mounted on the tube wall. In addition, two electrode configurations, aligned and offset, with fixed electrode spacing have been considered. The electrodes at both stages are charged at voltages in positive polarity from 18 kV to 22 kV. The velocity profile and volume flow rate delivered are compared with those produced by the same pump operating at even voltages to provide additional insight to the problem. The results thus obtained have important implications for practical use of EHD gas pump.
- 1 May 2019
- Published by Elsevier in Journal of Electrostatics
- Vol. 99, 49-58
Effect of grounded electrode size on a single stage EHD gas pump performance in a square channel
- 1 May 2019
- Published by Elsevier in Journal of Electrostatics
- Vol. 99, 49-58
Effect of grounded electrode size on a single stage EHD gas pump performance in a square channel