Josef Havlicek
Research Subjects
Josef Havlicek has a total of 278 co-authors. Here are the top co-authors by number of shared publications:
- Martin Hron
Czech Academy of Sciences - Institute of Plasma Physics Prague, CZECH REPUBLIC
9 shared publications - Radomir Panek
Institute of Plasma Physics AS CR
9 shared publications - Petr Vondracek
Institute of Plasma Physics, Czech Academy of Sciences - Institute of Plasma Physics, Za Slovankou 3, P O Box 17, 182-21 Prague 8, Prague, 18000, CZECH REPUBLIC
7 shared publications - Lukas Kripner
Institute of Plasma Physics of the Czech Academy of Sciences
5 shared publications - Martin Imrisek
Institute of Plasma Physics of the Czech Academy of Sciences
5 shared publications - Vadim Yanovskiy
National Research Centre Kurchatov Institute
5 shared publications
Latest Publications
- 9 November 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 234
Evaluation of electromagnetic loads on the COMPASS-U tokamak limiters during disruptions
- 9 November 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 234
Evaluation of electromagnetic loads on the COMPASS-U tokamak limiters during disruptions
- Open Access
- 29 October 2026
- Published by IOP Publishing in Nuclear Fusion
CarMa0NL modelling of COMPASS halo currents
A vertical displacement event in the COMPASS tokamak is modelled using the CarMa0NL code, with the halo-current width treated as a free parameter. The simulations that best reproduce the experimental evolution are those in which the resulting safety factor at the last closed flux surface remains above unity. This result is consistent with the possibility that the interaction of the \(m/n=1/1\) mode with higher harmonics, and the associated formation of a stochastic magnetic field-line structure, may contribute to setting the halo-current width. The potential relevance of this observation to scrape-off-layer widening and divertor heat-load mitigation during normal operation is discussed.- 29 October 2026
- Published by IOP Publishing in Nuclear Fusion
Open AccessCarMa0NL modelling of COMPASS halo currents
A vertical displacement event in the COMPASS tokamak is modelled using the CarMa0NL code, with the halo-current width treated as a free parameter. The simulations that best reproduce the experimental evolution are those in which the resulting safety factor at the last closed flux surface remains above unity. This result is consistent with the possibility that the interaction of the \(m/n=1/1\) mode with higher harmonics, and the associated formation of a stochastic magnetic field-line structure, may contribute to setting the halo-current width. The potential relevance of this observation to scrape-off-layer widening and divertor heat-load mitigation during normal operation is discussed. - Open Access
- 18 May 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (7)
Numerical modelling and optimization of vacuum field during plasma initiation in view of the operation of the COMPASS Upgrade tokamak
The COMPASS Upgrade tokamak will have dimensions R0 = 0.894 m and a ∼ 0.27 m with high-field (Bt ∼ 5 T), high-current (Ip ∼ 2 MA), high-triangularity (δ ∼ 0.4–0.6) capabilities. This contribution aims at establishing open loop circuits currents scenarios for complete plasma initiation (breakdown and burn-through) and initial current ramp-up in both low field (2.5 T) and high field (5 T) conditions. A complete electro-magnetic model of the future device was derived and linearized through the FIESTA code : in particular the Passive Stabilizing Plates have been consistently included. The optimization algorithm aims at providing the currents necessary to generate the proper vacuum field and maintain the plasma in its initial position against the inner limiter. It relies on the YFactory optimization tool. We present for the first time a fully optimized plasma initiation strategy that provides the feed-forward currents of all the coils from breakdown to the ∼ 150 kA mark, without any active feedback. The optimization takes into account a certain number of control points for the field and flux values which allows to guide the null size and shape, as well as ensures initial radial and vertical stability. The breakdown strategy is discussed with respect to the null geometry and the maximum loop voltage requested during the breakdown. The outputs of the optimization are tested via the DYON code for a reasonable range of neutral prefill densities. The duration of burn-through is analysed and an optimum breakdown configuration is identified that minimizes burn-through time, current consumption and stresses. The optimization is further refined in order to minimize the stress in the sliding joint of the Toroidal Field coil which is evaluated by ANSYS APDL model. The combined approach provides an operational space for COMPASS-U startup that is consistent with both electromagnetic and structural constraints.
- 18 May 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (7)
Open AccessNumerical modelling and optimization of vacuum field during plasma initiation in view of the operation of the COMPASS Upgrade tokamak
The COMPASS Upgrade tokamak will have dimensions R0 = 0.894 m and a ∼ 0.27 m with high-field (Bt ∼ 5 T), high-current (Ip ∼ 2 MA), high-triangularity (δ ∼ 0.4–0.6) capabilities. This contribution aims at establishing open loop circuits currents scenarios for complete plasma initiation (breakdown and burn-through) and initial current ramp-up in both low field (2.5 T) and high field (5 T) conditions. A complete electro-magnetic model of the future device was derived and linearized through the FIESTA code : in particular the Passive Stabilizing Plates have been consistently included. The optimization algorithm aims at providing the currents necessary to generate the proper vacuum field and maintain the plasma in its initial position against the inner limiter. It relies on the YFactory optimization tool. We present for the first time a fully optimized plasma initiation strategy that provides the feed-forward currents of all the coils from breakdown to the ∼ 150 kA mark, without any active feedback. The optimization takes into account a certain number of control points for the field and flux values which allows to guide the null size and shape, as well as ensures initial radial and vertical stability. The breakdown strategy is discussed with respect to the null geometry and the maximum loop voltage requested during the breakdown. The outputs of the optimization are tested via the DYON code for a reasonable range of neutral prefill densities. The duration of burn-through is analysed and an optimum breakdown configuration is identified that minimizes burn-through time, current consumption and stresses. The optimization is further refined in order to minimize the stress in the sliding joint of the Toroidal Field coil which is evaluated by ANSYS APDL model. The combined approach provides an operational space for COMPASS-U startup that is consistent with both electromagnetic and structural constraints.
- Open Access
- 10 June 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (6) , 065030
Physics drivers for the plasma-facing component design of the COMPASS-U tokamak
The main drivers for the metallic plasma-facing component (PFC) design of the COMPASS Upgrade (COMPASS-U) tokamak (B T ⩽5 T, I P ⩽ 2 MA, R geo = 0.9 m, a geo = 0.27 m, t flattop ⩽ 3 s) derived from physics considerations are presented in this paper. Requirements on the plasma-wall gaps are given based on previous experimental observations in other devices. Gaps at the inner/outer midplane are set to minimum values 20 and 40 mm, respectively, to allow all magnetic equilibria in the lower and upper single-null configurations to fit in the PFC outline, to allow an efficient flow in the scrape-off layer towards the divertor and to minimize the impurity flux from the wall. The closed tungsten divertor was designed with a similar shape to ITER’s divertor since COMPASS-U has a similar aspect ratio and uses an ITER-like equilibrium for its baseline scenario. Steady-state thermal loads are calculated at the outer strike-point, where they are expected to be the highest, in attached conditions using a 0D energy balance (⩾150 MW m−2) and in detached conditions using BIT1 kinetic calculations (∼70 MW m−2). Transient thermal loads range from 1.2 MJ m−2 for ELMs (maximum parallel peak energy fluence at targets) to 0.6–1.2 GW m−2 in ∼0.5 ms for high-energy vertical displacement events (maximum perpendicular heat flux density). Electromagnetic loads are calculated during disruptions using an in-house parametric model, accounting for current quench (CQ) and halo current contributions and validated by simulations using the CarMa0NL code, which is able to describe the nonlinear evolution of axisymmetric plasmas in the presence of 3D volumetric structures. The CQ rate is expected to be at least δI P/δt = 3 MA ms−1, and the halo current magnitude is set to 75% of the pre-disruptive maximum plasma current, according to the ITPA disruption database, yielding I halo = 1.5 MA. Maximum total force acts on the bottom divertor baffle with a value of ∼60 kN and the corresponding total torque is ∼4 kN m.
- 10 June 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (6) , 065030
Open AccessPhysics drivers for the plasma-facing component design of the COMPASS-U tokamak
The main drivers for the metallic plasma-facing component (PFC) design of the COMPASS Upgrade (COMPASS-U) tokamak (B T ⩽5 T, I P ⩽ 2 MA, R geo = 0.9 m, a geo = 0.27 m, t flattop ⩽ 3 s) derived from physics considerations are presented in this paper. Requirements on the plasma-wall gaps are given based on previous experimental observations in other devices. Gaps at the inner/outer midplane are set to minimum values 20 and 40 mm, respectively, to allow all magnetic equilibria in the lower and upper single-null configurations to fit in the PFC outline, to allow an efficient flow in the scrape-off layer towards the divertor and to minimize the impurity flux from the wall. The closed tungsten divertor was designed with a similar shape to ITER’s divertor since COMPASS-U has a similar aspect ratio and uses an ITER-like equilibrium for its baseline scenario. Steady-state thermal loads are calculated at the outer strike-point, where they are expected to be the highest, in attached conditions using a 0D energy balance (⩾150 MW m−2) and in detached conditions using BIT1 kinetic calculations (∼70 MW m−2). Transient thermal loads range from 1.2 MJ m−2 for ELMs (maximum parallel peak energy fluence at targets) to 0.6–1.2 GW m−2 in ∼0.5 ms for high-energy vertical displacement events (maximum perpendicular heat flux density). Electromagnetic loads are calculated during disruptions using an in-house parametric model, accounting for current quench (CQ) and halo current contributions and validated by simulations using the CarMa0NL code, which is able to describe the nonlinear evolution of axisymmetric plasmas in the presence of 3D volumetric structures. The CQ rate is expected to be at least δI P/δt = 3 MA ms−1, and the halo current magnitude is set to 75% of the pre-disruptive maximum plasma current, according to the ITPA disruption database, yielding I halo = 1.5 MA. Maximum total force acts on the bottom divertor baffle with a value of ∼60 kN and the corresponding total torque is ∼4 kN m.
- Open Access
- 3 September 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (10) , 106029
Quantification of locked mode instability triggered by a change in confinement
This work presents the first analysis of the disruptive locked mode (LM) triggered by the dynamics of a confinement change. It shows that, under certain conditions, the LM threshold during the transient is significantly lower than expected from steady states. We investigate the sensitivity to a controlled n = 1 error field (EF) activated prior to the L-H transition in the COMPASS tokamak, at q 95 ∼ 3, β N ∼ 1, and using EF coils on the high-field side of the vessel. A threshold for EF penetration subsequent to the L-H transition is identified, which shows no significant trend with density or applied torque, and is an apparent consequence of the reduced intrinsic rotation of the 2/1 mode during this transient phase. This finding challenges the assumption made in theoretical and empirical works that natural mode rotation can be predicted by global plasma parameters and urges against using any parametric EF penetration scaling derived from steady-state experiments to define the EF correction strategy in the entire discharge. Furthermore, even at EFs below the identified penetration threshold, disruptive locking of sawtooth-seeded 2/1 tearing modes is observed after about 30% of L-H transitions without external torque.
- 3 September 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (10) , 106029
Open AccessQuantification of locked mode instability triggered by a change in confinement
This work presents the first analysis of the disruptive locked mode (LM) triggered by the dynamics of a confinement change. It shows that, under certain conditions, the LM threshold during the transient is significantly lower than expected from steady states. We investigate the sensitivity to a controlled n = 1 error field (EF) activated prior to the L-H transition in the COMPASS tokamak, at q 95 ∼ 3, β N ∼ 1, and using EF coils on the high-field side of the vessel. A threshold for EF penetration subsequent to the L-H transition is identified, which shows no significant trend with density or applied torque, and is an apparent consequence of the reduced intrinsic rotation of the 2/1 mode during this transient phase. This finding challenges the assumption made in theoretical and empirical works that natural mode rotation can be predicted by global plasma parameters and urges against using any parametric EF penetration scaling derived from steady-state experiments to define the EF correction strategy in the entire discharge. Furthermore, even at EFs below the identified penetration threshold, disruptive locking of sawtooth-seeded 2/1 tearing modes is observed after about 30% of L-H transitions without external torque.
- 20 December 2022
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 65 (2) , 025004
Characterisation of the auxiliary heating power delivered by the 40 keV neutral beam injectors on the COMPASS tokamak
Two identical neutral beam injectors (NBIs) have been installed on the COMPASS tokamak. Each of them is capable of producing a deuterium (or hydrogen, helium) neutral beam with nominal power of up to 400 kW at 40 keV. Since the COMPASS tokamak is a compact machine, the design of the neutral beams was carefully optimized to fit the neutral beam through the narrow ports of the tokamak. However, once the neutral beams are operated out of the scope of their optimal parameters, additional power losses occur due to neutral beam scraping. This article investigates the amount of power loss due to neutral beam scraping. The losses are calculated using the neutral beam models and measured neutral beam parameters. The calculated results are compared with the measured power delivered into the plasma. Two different neutral beam models are employed. One describes the neutral beam as a sum of small beamlets, which are Gaussian-like. The second one describes the neutral beam as a single Gaussian beam. The amount of the power lost to scraping is determined by both models and compared. Neutral beam parameters, the input parameters for both models, are derived from the Doppler-shifted spectra emitted by fast neutral atoms. It is shown that when operating NBIs at nominal parameters, the scraping losses are negligible ( < 5% ). If the NBIs are operated too far from the nominal parameters, the scraping losses can reach up to ∼60% of the NBI output power. As the highest fractional losses occur with low power NBI, the beam duct is capable of withstanding the corresponding power loads. The expected auxiliary heating power P A U X , the power entering the tokamak chamber carried by fast neutrals, is benchmarked against the additional plasma input power observed in the measured plasma parameters P N B I . The additional plasma input power P N B I is derived from the plasma power balance. The power balance terms are independent of the neutral beam model used for the auxiliary heating power calculation P A U X . The results of the power balance evaluation reveal a difference between two NBIs installed on COMPASS. One of the injectors systematically delivers 17% less power than the other into the plasma given the same beam parameters. It is concluded that the additional losses occur before the beam enters the tokamak chamber.
- 20 December 2022
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 65 (2) , 025004
Characterisation of the auxiliary heating power delivered by the 40 keV neutral beam injectors on the COMPASS tokamak
Two identical neutral beam injectors (NBIs) have been installed on the COMPASS tokamak. Each of them is capable of producing a deuterium (or hydrogen, helium) neutral beam with nominal power of up to 400 kW at 40 keV. Since the COMPASS tokamak is a compact machine, the design of the neutral beams was carefully optimized to fit the neutral beam through the narrow ports of the tokamak. However, once the neutral beams are operated out of the scope of their optimal parameters, additional power losses occur due to neutral beam scraping. This article investigates the amount of power loss due to neutral beam scraping. The losses are calculated using the neutral beam models and measured neutral beam parameters. The calculated results are compared with the measured power delivered into the plasma. Two different neutral beam models are employed. One describes the neutral beam as a sum of small beamlets, which are Gaussian-like. The second one describes the neutral beam as a single Gaussian beam. The amount of the power lost to scraping is determined by both models and compared. Neutral beam parameters, the input parameters for both models, are derived from the Doppler-shifted spectra emitted by fast neutral atoms. It is shown that when operating NBIs at nominal parameters, the scraping losses are negligible ( < 5% ). If the NBIs are operated too far from the nominal parameters, the scraping losses can reach up to ∼60% of the NBI output power. As the highest fractional losses occur with low power NBI, the beam duct is capable of withstanding the corresponding power loads. The expected auxiliary heating power P A U X , the power entering the tokamak chamber carried by fast neutrals, is benchmarked against the additional plasma input power observed in the measured plasma parameters P N B I . The additional plasma input power P N B I is derived from the plasma power balance. The power balance terms are independent of the neutral beam model used for the auxiliary heating power calculation P A U X . The results of the power balance evaluation reveal a difference between two NBIs installed on COMPASS. One of the injectors systematically delivers 17% less power than the other into the plasma given the same beam parameters. It is concluded that the additional losses occur before the beam enters the tokamak chamber.
- Open Access
- 1 April 2022
- Published by IOP Publishing in Nuclear Fusion
- Vol. 62 (4) , 042021
Overview of the COMPASS results *
COMPASS addressed several physical processes that may explain the behaviour of important phenomena. This paper presents results related to the main fields of COMPASS research obtained in the recent two years, including studies of turbulence, L–H transition, plasma material interaction, runaway electron, and disruption physics: Tomographic reconstruction of the edge/SOL turbulence observed by a fast visible camera allowed to visualize turbulent structures without perturbing the plasma. Dependence of the power threshold on the X-point height was studied and related role of radial electric field in the edge/SOL plasma was identified. The effect of high-field-side error fields on the L–H transition was investigated in order to assess the influence of the central solenoid misalignment and the possibility to compensate these error fields by low-field-side coils. Results of fast measurements of electron temperature during ELMs show the ELM peak values at the divertor are around 80% of the initial temperature at the pedestal. Liquid metals were used for the first time as plasma facing material in ELMy H-mode in the tokamak divertor. Good power handling capability was observed for heat fluxes up to 12 MW m−2 and no direct droplet ejection was observed. Partial detachment regime was achieved by impurity seeding in the divertor. The evolution of the heat flux footprint at the outer target was studied. Runaway electrons were studied using new unique systems—impact calorimetry, carbon pellet injection technique, wide variety of magnetic perturbations. Radial feedback control was imposed on the beam. Forces during plasma disruptions were monitored by a number of new diagnostics for vacuum vessel (VV) motion in order to contribute to the scaling laws of sideways disruption forces for ITER. Current flows towards the divertor tiles, incl. possible short-circuiting through PFCs, were investigated during the VDE experiments. The results support ATEC model and improve understanding of disruption loads.
- 1 April 2022
- Published by IOP Publishing in Nuclear Fusion
- Vol. 62 (4) , 042021
Open AccessOverview of the COMPASS results *
COMPASS addressed several physical processes that may explain the behaviour of important phenomena. This paper presents results related to the main fields of COMPASS research obtained in the recent two years, including studies of turbulence, L–H transition, plasma material interaction, runaway electron, and disruption physics: Tomographic reconstruction of the edge/SOL turbulence observed by a fast visible camera allowed to visualize turbulent structures without perturbing the plasma. Dependence of the power threshold on the X-point height was studied and related role of radial electric field in the edge/SOL plasma was identified. The effect of high-field-side error fields on the L–H transition was investigated in order to assess the influence of the central solenoid misalignment and the possibility to compensate these error fields by low-field-side coils. Results of fast measurements of electron temperature during ELMs show the ELM peak values at the divertor are around 80% of the initial temperature at the pedestal. Liquid metals were used for the first time as plasma facing material in ELMy H-mode in the tokamak divertor. Good power handling capability was observed for heat fluxes up to 12 MW m−2 and no direct droplet ejection was observed. Partial detachment regime was achieved by impurity seeding in the divertor. The evolution of the heat flux footprint at the outer target was studied. Runaway electrons were studied using new unique systems—impact calorimetry, carbon pellet injection technique, wide variety of magnetic perturbations. Radial feedback control was imposed on the beam. Forces during plasma disruptions were monitored by a number of new diagnostics for vacuum vessel (VV) motion in order to contribute to the scaling laws of sideways disruption forces for ITER. Current flows towards the divertor tiles, incl. possible short-circuiting through PFCs, were investigated during the VDE experiments. The results support ATEC model and improve understanding of disruption loads.
- 1 October 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 171
Design and verification status of COMPASS-U vacuum vessel and stabilization loop
- 1 October 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 171
Design and verification status of COMPASS-U vacuum vessel and stabilization loop
- 1 September 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 170
Conceptual design of the COMPASS-U control systems
- 1 September 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 170
Conceptual design of the COMPASS-U control systems
- Open Access
- 1 August 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 169
Preliminary design of the COMPASS upgrade tokamak
- 1 August 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 169
Open AccessPreliminary design of the COMPASS upgrade tokamak