Mahdi Ghotbi Maleki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mahdi Ghotbi Maleki has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Reza Mohammadi Chabanloo
Department of Electrical Engineering, Shahid Beheshti University, Tehran, Iran
11 shared publications Hamid Javadi
Department of Electrical Engineering Shahid Beheshti University Tehran Iran
4 shared publications- Majid Sanaye-Pasand
University of Tehran
4 shared publications - Maher Abdelkhalek Azzouz
University of Windsor
2 shared publications Mojtaba Khederzadeh
2 shared publicationsSiamak Farajzadeh
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (6) , 5093-5104
Clustering Technique for Adaptive Overcurrent Protection in Active Distribution Networks: Addressing Numerous Operational Conditions
Clustering of network operational conditions (NOCs) and coordination of overcurrent relays (OCRs) for designing setting group (SG)-based adaptive protection schemes in active distribution networks (ADNs) are typically addressed separately in the existing criterion-based methods. However, integrating these two interdependent problems into a unified optimization framework increases the number of optimization variables, diminishing the efficiency of the existing optimization-based methods in networks with numerous numbers of NOCs. This study introduces a criterion-based method that treats NOCs clustering as a sub-problem within the OCRs coordination process, effectively leveraging the advantages of existing methods. By decoupling the number of optimization variables from the number of NOCs, the proposed method is particularly adept for application in ADNs characterized by numerous NOCs. The method employs the OCRs operating times as the clustering criterion, reflecting the performances of OCRs in their primary and backup protection tasks. Simulation results indicate that the proposed method significantly outperforms the existing methods in achieving optimization convergence and reducing OCRs operating times, especially in ADNs with numerous NOCs and various types of distributed generations. Also, the compliance with the IEC 61850 standard is investigated to ensure the practical implementation of the proposed adaptive protection scheme.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (6) , 5093-5104
Clustering Technique for Adaptive Overcurrent Protection in Active Distribution Networks: Addressing Numerous Operational Conditions
Clustering of network operational conditions (NOCs) and coordination of overcurrent relays (OCRs) for designing setting group (SG)-based adaptive protection schemes in active distribution networks (ADNs) are typically addressed separately in the existing criterion-based methods. However, integrating these two interdependent problems into a unified optimization framework increases the number of optimization variables, diminishing the efficiency of the existing optimization-based methods in networks with numerous numbers of NOCs. This study introduces a criterion-based method that treats NOCs clustering as a sub-problem within the OCRs coordination process, effectively leveraging the advantages of existing methods. By decoupling the number of optimization variables from the number of NOCs, the proposed method is particularly adept for application in ADNs characterized by numerous NOCs. The method employs the OCRs operating times as the clustering criterion, reflecting the performances of OCRs in their primary and backup protection tasks. Simulation results indicate that the proposed method significantly outperforms the existing methods in achieving optimization convergence and reducing OCRs operating times, especially in ADNs with numerous NOCs and various types of distributed generations. Also, the compliance with the IEC 61850 standard is investigated to ensure the practical implementation of the proposed adaptive protection scheme.
- 15 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 20 (2) , 468-479
Low-Iterative Fault Location Method for IBR-Connected Transmission Lines Considering System Non-Homogeneity
Novel fault location methods have relied on the assumption of system homogeneity, which becomes increasingly invalid in different scenarios, e.g., high-resistance faults. On the other hand, the IEEE 2800-2022 standard, addressing the interconnection of inverter-based resources (IBRs) to transmission networks, recommends the injection of negative sequence reactive current as a low-voltage ride-through requirement. However, adherence to this standard does not inherently ensure that IBRs exhibit behavior identical to that of traditional synchronous generators, to enhance the performance of fault location methods in the presence of IBRs. This article presents an enhanced local-based fault location method designed for lines connecting IBRs, especially suitable for nonhomogeneous networks. The proposed method effectively addresses challenges posed by high-resistance faults and remote-infeed effects, without relying on the assumption of system homogeneity. Moreover, the formulated methodology enhances fault location accuracy using a low-iterative procedure. The proposed method for two-phase-to-ground faults requires the zero sequence impedance of the remote-side network. This article introduces a novel method for estimating this impedance utilizing locally measured quantities obtained during the fault. Simulation results demonstrate a maximum calculated discrepancy of 0.10% in fault location estimation for both symmetric and asymmetric high-resistance faults, underscoring the robustness and precision of the proposed method.
- 15 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 20 (2) , 468-479
Low-Iterative Fault Location Method for IBR-Connected Transmission Lines Considering System Non-Homogeneity
Novel fault location methods have relied on the assumption of system homogeneity, which becomes increasingly invalid in different scenarios, e.g., high-resistance faults. On the other hand, the IEEE 2800-2022 standard, addressing the interconnection of inverter-based resources (IBRs) to transmission networks, recommends the injection of negative sequence reactive current as a low-voltage ride-through requirement. However, adherence to this standard does not inherently ensure that IBRs exhibit behavior identical to that of traditional synchronous generators, to enhance the performance of fault location methods in the presence of IBRs. This article presents an enhanced local-based fault location method designed for lines connecting IBRs, especially suitable for nonhomogeneous networks. The proposed method effectively addresses challenges posed by high-resistance faults and remote-infeed effects, without relying on the assumption of system homogeneity. Moreover, the formulated methodology enhances fault location accuracy using a low-iterative procedure. The proposed method for two-phase-to-ground faults requires the zero sequence impedance of the remote-side network. This article introduces a novel method for estimating this impedance utilizing locally measured quantities obtained during the fault. Simulation results demonstrate a maximum calculated discrepancy of 0.10% in fault location estimation for both symmetric and asymmetric high-resistance faults, underscoring the robustness and precision of the proposed method.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 1
Efficient Piecewise Curve for Numerical Overcurrent Relays Under Limitations Imposed by the IEC 61850 Standard
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 1
Open AccessEfficient Piecewise Curve for Numerical Overcurrent Relays Under Limitations Imposed by the IEC 61850 Standard
- 31 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (2) , 875-886
Coordination of Directional Overcurrent Relays in Transient Topologies Induced by Faster Operation of Remote-Side Circuit Breakers
This paper presents a novel methodology for directional overcurrent relays (DOCRs) coordination that effectively accounts for the transient topologies triggered by faster operation of remote-side circuit breakers (CBs), thereby preventing miscoordination and enhancing power system reliability. The methodology is based on the dynamic model of DOCR, allowing for the incorporation of short-circuit currents associated with the moments before and after the operation of remote-side CB in the coordination process. This method facilitates the determination of time multiplier, pickup current, and characteristic curve settings; while earlier methods are unable to determine the latter two settings because updating these settings alters the slope of DOCR curve, shifting the specified interference between DOCRs on both sides of a line to a different fault location. The proposed method is structured as a nested optimization problem: the outer layer establishes the initial operational sequence of DOCRs on both sides of each line, while the inner layer updates the DOCR settings to prevent miscoordination. Comprehensive consideration of various short-circuit types and locations in the study about the faster operation of remote-side CB enhances the robustness of the proposed coordination method compare to existing ones, which is also validated through hardware-in-the-loop testing.
- 31 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (2) , 875-886
Coordination of Directional Overcurrent Relays in Transient Topologies Induced by Faster Operation of Remote-Side Circuit Breakers
This paper presents a novel methodology for directional overcurrent relays (DOCRs) coordination that effectively accounts for the transient topologies triggered by faster operation of remote-side circuit breakers (CBs), thereby preventing miscoordination and enhancing power system reliability. The methodology is based on the dynamic model of DOCR, allowing for the incorporation of short-circuit currents associated with the moments before and after the operation of remote-side CB in the coordination process. This method facilitates the determination of time multiplier, pickup current, and characteristic curve settings; while earlier methods are unable to determine the latter two settings because updating these settings alters the slope of DOCR curve, shifting the specified interference between DOCRs on both sides of a line to a different fault location. The proposed method is structured as a nested optimization problem: the outer layer establishes the initial operational sequence of DOCRs on both sides of each line, while the inner layer updates the DOCR settings to prevent miscoordination. Comprehensive consideration of various short-circuit types and locations in the study about the faster operation of remote-side CB enhances the robustness of the proposed coordination method compare to existing ones, which is also validated through hardware-in-the-loop testing.
- 14 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (11) , 9034-9044
Resilience Enhancement of Adaptive Overcurrent Protection for Active Distribution Networks Against Relay-Setting Cyber-Attacks
Cyber-attacks that alter relay settings can cause relay malfunctions, increasing unsupplied energy, and diminishing system reliability. This article addresses the vulnerability of overcurrent adaptive protection schemes in active distribution networks against relay-setting cyber-attacks (RSCAs). The proposed method involves storing settings in the memory of overcurrent relays (OCR) and modifying the active setting group instead of directly updating settings in response to the network conditions changing, such as connection to or disconnection from the upstream grid and the on/off statuses of distributed generations, thereby preventing OCRs maloperation. Furthermore, the prestored settings are derived using novel coordination constraints to ensure that RSCAs do not lead to miscoordination among the OCRs, thus maintaining network reliability and reducing unsupplied energy. Rather than merely detecting RSCAs, this method leverages the setting group capabilities of contemporary OCRs to develop an adaptive protection scheme based on the IEC 61850 standard for active distribution networks, enhancing resilience to cyber-attacks.
- 14 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (11) , 9034-9044
Resilience Enhancement of Adaptive Overcurrent Protection for Active Distribution Networks Against Relay-Setting Cyber-Attacks
Cyber-attacks that alter relay settings can cause relay malfunctions, increasing unsupplied energy, and diminishing system reliability. This article addresses the vulnerability of overcurrent adaptive protection schemes in active distribution networks against relay-setting cyber-attacks (RSCAs). The proposed method involves storing settings in the memory of overcurrent relays (OCR) and modifying the active setting group instead of directly updating settings in response to the network conditions changing, such as connection to or disconnection from the upstream grid and the on/off statuses of distributed generations, thereby preventing OCRs maloperation. Furthermore, the prestored settings are derived using novel coordination constraints to ensure that RSCAs do not lead to miscoordination among the OCRs, thus maintaining network reliability and reducing unsupplied energy. Rather than merely detecting RSCAs, this method leverages the setting group capabilities of contemporary OCRs to develop an adaptive protection scheme based on the IEC 61850 standard for active distribution networks, enhancing resilience to cyber-attacks.
- 20 December 2024
- Published by Elsevier in Expert Systems with Applications
- Vol. 267
Exponential-based dynamic objective function for coordination of overcurrent relays in power networks
- 20 December 2024
- Published by Elsevier in Expert Systems with Applications
- Vol. 267
Exponential-based dynamic objective function for coordination of overcurrent relays in power networks
- Open Access
- 12 April 2023
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 17 (11) , 2667-2686
Load shedding method aimed fast voltage recovery to prevent interference of FIDVR with UV relays
The fault‐induced delayed voltage recovery (FIDVR) and short‐term voltage instability (STVI) phenomena appear in networks with high penetration of induction motor loads because the increase in requested reactive powers of these loads prevents the voltages from quickly returning to their pre‐fault levels. Load shedding (LS) is one of the ways to deal with FIDVR and STVI and reduce the imbalance between the generation and demand of reactive power. Under‐voltage (UV) relays that disconnect loads during voltage drop cannot effectively deal with this phenomenon because of their inability to detect the effective loads on the reduction of FIDVR and STVI severities. Therefore, the operation of UV relays during these phenomena causes unnecessary load disconnection, and the interference of their operations with FIDVR and STVI must be avoided. This paper presents two wide‐area approaches based on network and loads parameters, the first of which deals with the most critical FIDVR, and the second tries to simultaneously handle critical FIDVRs of all buses. Also, bus prioritization for LS during STVI has been addressed. Simulation results revealed the better performance of the proposed approaches than the previous ones in terms of the amount of LS and the number of selected buses for LS.
- 12 April 2023
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 17 (11) , 2667-2686
Open AccessLoad shedding method aimed fast voltage recovery to prevent interference of FIDVR with UV relays
The fault‐induced delayed voltage recovery (FIDVR) and short‐term voltage instability (STVI) phenomena appear in networks with high penetration of induction motor loads because the increase in requested reactive powers of these loads prevents the voltages from quickly returning to their pre‐fault levels. Load shedding (LS) is one of the ways to deal with FIDVR and STVI and reduce the imbalance between the generation and demand of reactive power. Under‐voltage (UV) relays that disconnect loads during voltage drop cannot effectively deal with this phenomenon because of their inability to detect the effective loads on the reduction of FIDVR and STVI severities. Therefore, the operation of UV relays during these phenomena causes unnecessary load disconnection, and the interference of their operations with FIDVR and STVI must be avoided. This paper presents two wide‐area approaches based on network and loads parameters, the first of which deals with the most critical FIDVR, and the second tries to simultaneously handle critical FIDVRs of all buses. Also, bus prioritization for LS during STVI has been addressed. Simulation results revealed the better performance of the proposed approaches than the previous ones in terms of the amount of LS and the number of selected buses for LS.
- Top Cited Papers
- 1 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 12 (2) , 1185-1193
Design of Setting Group-Based Overcurrent Protection Scheme for Active Distribution Networks Using MILP
- 1 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 12 (2) , 1185-1193
Top Cited PapersDesign of Setting Group-Based Overcurrent Protection Scheme for Active Distribution Networks Using MILP
- Open Access
- 19 October 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (23) , 5607-5616
Determination of optimal breakpoint set of overcurrent relays using modified depth‐first search and mixed‐integer linear programming
In the process of determination of breakpoints for overcurrent relays (OCR), different sets with equal number of OCRs can be selected as minimum breakpoint set (MBPS). Therefore, determination of the most appropriate MBPS is an issue which must be considered. This paper proposes a prioritization between different MBPSs based on the sum of operating times of OCRs. In this case, a set which results the minimum sum of operating times is selected as the appropriate MBPS. For this purpose, the proposed method combines two problems: determination of MBPS and coordination of OCRs, and is expressed in mixed‐integer linear programming (MILP) form. Also, a modified depth‐first search (DFS) algorithm is applied to determine the OCRs contained loops of studied networks. It is shown that the proposed method has the capability to be combined with previous defined expert rules in this field in order to consider the network conditions in the process of determination of optimal breakpoint set (OBPS). The proposed method has been implemented on various size networks, and the results show the effectiveness of proposed method in determining breakpoint set with the least number in first priority and minimum operating times of relays in second priority.
- 19 October 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (23) , 5607-5616
Open AccessDetermination of optimal breakpoint set of overcurrent relays using modified depth‐first search and mixed‐integer linear programming
In the process of determination of breakpoints for overcurrent relays (OCR), different sets with equal number of OCRs can be selected as minimum breakpoint set (MBPS). Therefore, determination of the most appropriate MBPS is an issue which must be considered. This paper proposes a prioritization between different MBPSs based on the sum of operating times of OCRs. In this case, a set which results the minimum sum of operating times is selected as the appropriate MBPS. For this purpose, the proposed method combines two problems: determination of MBPS and coordination of OCRs, and is expressed in mixed‐integer linear programming (MILP) form. Also, a modified depth‐first search (DFS) algorithm is applied to determine the OCRs contained loops of studied networks. It is shown that the proposed method has the capability to be combined with previous defined expert rules in this field in order to consider the network conditions in the process of determination of optimal breakpoint set (OBPS). The proposed method has been implemented on various size networks, and the results show the effectiveness of proposed method in determining breakpoint set with the least number in first priority and minimum operating times of relays in second priority.