Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sangwon Cha has a total of 187 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simultaneous Determination of Aromatic Amines in Tattoo Ink by Gas Chromatography–Electron Ionization (GC-EI)–Mass Spectrometry (MS) and Tandem MS (MS/MS)

    by Eunyoung Shin, Hyebeen Kim, Jihye Choi, Minjae Kang, Juhui Shin, Sangwon Cha

    Aromatic amines (AAs) are potent carcinogens found in tattoo inks that pose significant health risks. Precise quantitative analysis is essential for safety. In this study, we developed and validated a robust method for the simultaneous quantification of 21 regulated AAs using both gas chromatography–electron ionization (GC-EI)–mass spectrometry (MS) and tandem MS (MS/MS). After optimizing separation conditions, MS-based selected ion monitoring (SIM) and MS/MS-based multiple reaction monitoring (MRM) were evaluated. While both methods were largely sufficient to ensure compliance with international safety thresholds, the MRM-based approach exhibited superior detection capability with comparable analytical accuracy and precision, providing a more effective tool for trace-level hazardous compound analysis. The developed MRM method was applied to eight commercial tattoo inks, identifying five AAs in five products. Notably, o-toluidine, o-anisidine, and 3,3′-dichlorobenzidine significantly exceeded the regulatory limit (5.0 mg/kg), particularly in green and yellow inks. The dual-capability GC-MS platform—combining high-performance MRM quantification with robust spectral confirmation—ensures the high throughput and analytical confidence necessary for regulatory compliance and public health protection.

  • Open Access

    Negative Paper Spray Ionization Mass Spectrometry for the Determination of Endocrine-Disrupting Chemicals with Application to Paraben Analysis in Cosmetics

    by Seonyoung Cho, Sarmila Shrestha Amatya, Hyerin Bahng, Eungyeong Lee, Yunsang Ko, Sangwon Cha

    Paper spray ionization mass spectrometry (PSI-MS) enables rapid analysis with minimal sample preparation, yet negative-ion mode performance has been limited by poor sensitivity and unstable signals, similar to conventional electrospray ionization. In this study, we optimized negative PSI tandem MS (MS/MS) for twelve endocrine-disrupting chemicals (EDCs) and related biomarkers—including bisphenols, phthalates, parabens, and substituted phenols—used as model analytes. A systematic solvent and additive screen identified 1 mM ammonium fluoride in methanol and 0.1% ammonium hydroxide in 9:1 MeOH/carbon tetrachloride as optimal conditions, providing enhanced deprotonated-ion intensities and improved stability. Calibration curves generated under these conditions showed excellent linearity, with limits of quantitation (LOQs) in the low-ppb range. Application to cosmetic formulations demonstrated reliable paraben quantitation. In fortified hand cream, LOQs below 1 mg/kg were achieved, with recoveries of 93–110% and intra- and inter-day precision below 10% RSD. Notably, PSI-MS/MS performance was comparable to LC–MS/MS, without a separation step. These results demonstrate the feasibility of optimized negative PSI-MS as a sensitive and robust tool for paraben determination in cosmetics and highlight its potential as a versatile platform for broader EDC quantification.

  • Open Access

    Determination of Sulfites in Dried Fruits by Paper Spray Ionization Tandem Mass Spectrometry

    by Donghoon Lee, Heejin Ro, Seoyoung Hwang, Minkyu Lee, Hyebeen Kim, Jaeyoung Heo, Sangwon Cha

    Sulfite, a widely used food additive, is subject to regulated labeling. The extraction of sulfite as the stable hydroxymethylsulfonate (HMS) form and its quantitative analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been recognized for their good sensitivity, selectivity, and versatility across various food materials. This study aimed to develop a cost-effective and simpler method for sulfite quantitation, while maintaining the superior sensitivity and selectivity of mass spectrometry (MS). To achieve this, we introduced paper spray ionization (PSI), an ambient desorption ionization technique that could achieve the direct measurement of analytes without employing separation. We also employed a novel internal standard (IS) structurally similar to the analyte, replacing the more expensive isotopically labeled IS. Although the PSI-MS/MS method developed in this study exhibited slightly lower analytical performance compared to the conventional LC-MS/MS, it remained effective for sulfite analysis in dried fruits.


  • Open Access

    Simple Protein Analysis by Droplet Paper Spray Ionization Mass Spectrometry with Polyolefin Silica-Based Paper

    by Sung Jun An, Youngjoo Kal, Minjoo Jeong, Sumin Kang, Byeongho Kwak, Hyunsoo Kim, Shihyeon Ryu, Sangwon Cha

    Paper spray ionization mass spectrometry (PSI MS) has emerged as a notable method for the rapid analysis of biological samples. However, the typical cellulose-based paper tip is incompatible with protein detection due to the strong interaction between cellulose hydroxyl groups and proteins. In this study, we utilized a commercially available polyolefin-based synthetic paper, Teslin®, as an alternative PSI substrate for simple protein analysis. We have named this method “droplet PSI” MS, as the aqueous protein solution droplet retains its shape on the Teslin® paper tip. For droplet PSI, no further chemical pretreatment was necessary for the Teslin® substrate; the only required preparation was shaping the Teslin® paper into a triangular tip. In droplet PSI MS, protein ion signals were instantly detected from a protein solution droplet upon applying a spray solvent in situ along with high voltage (HV). When compared with conventional PSI MS, our method demonstrated superior sensitivity. The droplet PSI MS utilizing Teslin® also showcased flexibility in real-time observation of protein alterations induced by an acid additive. Additionally, the effects of spray solvent composition and the application method were discussed.


  • Open Access

    Toward Depth-Resolved Analysis of Plant Metabolites by Nanospray Desorption Electrospray Ionization Mass Spectrometry

    by Sangwon Cha, Gyouwoong Jun, Yougyeong Park, Sung Jun An, Donghoon Lee

    Nanospray desorption electrospray ionization (nano-DESI) is one of the ambient desorption ionization methods for mass spectrometry (MS), and it utilizes a steady-state liquid junction formed between two microcapillaries to directly extract analytes from sample surfaces with minimal sample damage. In this study, we employed nano-DESI MS to perform a metabolite fingerprinting analysis directly from a Hypericum leaf surface. Moreover, we investigated whether changes in metabolite fingerprints with time can be related to metabolite distribution according to depth. From a raw Hypericum leaf, the mass spectral fingerprints of key metabolites, including flavonoids and prenylated phloroglucinols, were successfully obtained using ethanol as a nano-DESI solvent, and the changes in their intensities were observed with time via full mass scan experiments. In addition, the differential extraction patterns of the obtained mass spectral fingerprints were clearly visualized over time through selected ion monitoring and pseudo-selected reaction monitoring experiments. To examine the correlation between the time-dependent changes in the metabolite fingerprints and depth-wise metabolite distribution, we performed a nano-DESI MS analysis against leaves whose surface layers were removed multiple times by forming polymeric gum Arabic films on their surfaces, followed by detaching. The preliminary results showed that the changes in the metabolite fingerprints according to the number of peelings showed a similar pattern with those obtained from the raw leaves over time.


  • Targeted Discovery of an Enediyne-Derived Cycloaromatized Compound, Jejucarboside A, from a Marine Actinomycete

    by Ji Hyeon Im, Daniel Shin, Yeon Hee Ban, Woong Sub Byun, Eun Seo Bae, Donghoon Lee, Young Eun Du, Jinsheng Cui, Yun Kwon, Sang-Jip Nam, et al.

    A genomic and spectroscopic signature-based search revealed a cycloaromatized enediyne, jejucarboside A (1), from a marine actinomycete strain. The structure of 1 was determined as a new cyclopenta[a]indene glycoside bearing carbonate functionality by nuclear magnetic resonance, high-resolution mass spectrometry (MS), MS/MS, infrared spectroscopy, and a modified Mosher's method. An iterative enediyne synthase pathway has been proposed for the putative biosynthesis of 1 by genomic analysis. Jejucarboside A exhibited cytotoxicity against the HCT116 colon carcinoma cells.


  • Fluoride-assisted liquid chromatography-tandem mass spectrometry method for simultaneous analysis of propofol and its metabolites without derivatization in urine

    by Kang Mi Lee, Sang Moon Han, Seunghwa Lee, Tae Young Jeong, Ho Jun Kim, Hophil Min, Ki Hun Kim, Sangwon Cha, Won Keun Oh, Jaeick Lee


  • Isomer separation and analysis of amphiphilic polysialogangliosides using reversed‐phase liquid chromatography‐mass spectrometry

    by Jun Young Park, Sarmila Amatya Shrestha, Sangwon Cha

    Gangliosides are amphiphilic, acidic glycosphingolipids possessing one or more sialic acid residues and several isobaric structural isomers with different abundances and bioactivities. Therefore, the distinction between these isomers is crucial for their proper profiling. Although liquid chromatography–mass spectrometry has been successfully employed for this purpose, the distinction process can still be improved, particularly regarding liquid chromatography. Recently, a reversed‐phase liquid chromatography method that could separate disialoganglioside isomers was reported; however, the distinction of trisialoganglioside isomers using reversed‐phase liquid chromatography has not been demonstrated. Here, we investigated the practicality of a reversed‐phase liquid chromatography with an octadecylsilane column for separating polysialoganglioside isomers and successfully achieved the isomer separation of disialogangliosides and trisialogangliosides for the first time. We also confirmed several crucial factors in the mobile‐phase composition, which affect the differential retention and mass spectral response of the isomers. First, an organic modifier, acetonitrile, exhibited superior selectivity against polysialogangliosides over methanol. Second, ammonium bicarbonate was the best ammonium salt additive among those tested, in terms of the separation efficiency and mass spectral response. Third, as the ammonium salt concentration increased, the negative electrospray ionization response was extensively suppressed, and the retention of gangliosides increased.


  • Open Access

    In Situ Separation and Analysis of Lipids by Paper Spray Ionization Mass Spectrometry

    by Youngju Kal, Sangwon Cha

    Paper spray ionization (PSI) is an extractive ambient ionization technique for mass spectrometry (MS), whereby a triangular paper tip serves as the sampling base and the electrospray tip. During PSI, analytes are extracted and transported to the edge of the paper tip by the applied spraying solvent. Analytes can be purified from a sample matrix and separated from each other by this transportation process. In this study, we investigated and utilized the analyte transportation process of PSI for the in situ separation and analysis of lipid mixtures. We found that differential transport of phosphatidylcholine (PC) and triacylglycerol (TAG), the two most abundant lipid classes in animals, occurred during PSI. We also found that the order in which these lipids moved strongly depended on how the spraying solvent was applied to the paper base. The more polar PC moved faster than the less polar TAG during PSI, when a polar solvent was slowly fed into a paper tip, whereas TAG was transported faster than PC when excess solvent was applied to the tip at once. In addition, we achieved a complete separation and detection of PC and TAG by slowly supplying a nonpolar solvent to a PSI tip.