SRStefan Rohde

Stefan Rohde

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stefan Rohde has a total of 114 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correction to: Comment on ESO/EANS/ESMINT Guideline on Aneurysmal Subarachnoid Haemorrhage

    by Stephan Meckel, Matthias Gawlitza, Klaus Kaier, Franziska Dorn, Stefan Rohde, Peter Schramm, Ansgar Berlis

  • Open Access

    Comment on ESO/EANS/ESMINT Guideline on Aneurysmal Subarachnoid Haemorrhage

    by Stephan Meckel, Matthias Gawlitza, Klaus Kaier, Franziska Dorn, Stefan Rohde, Peter Schramm, Ansgar Berlis

  • Open Access

    Evaluation of a Novel Enhanced Radiation Protection Device in Interventional Neuroradiology: a Phantom Study

    by Felix Bärenfänger, Gabriel Bartal, Patrik Hidefjäll, Fredrik Gellerstedt, Petra Apell, Stefan Rohde

    Introduction Scatter radiation during interventional neuroradiological (INR) procedures is potentially harmful to the operator and cath-lab staff. Enhanced radiation protection devices (ERPDs) aim to improve safety by minimizing scatter radiation in addition to standard and personal protective equipment (PPE). This study evaluated the efficacy of a novel ERPD in INR. Methods Radiation exposure of the main operator was estimated by measuring the local dose rate at the examination position. An anthropomorphic patient whole body phantom was used simulating a standard INR procedure. The relative dose reductions were determined for the following settings: a) MasterPeace (Texray AB, Sweden) combined with ceiling-suspended lead screen (Mavig, Germany) compared to no shielding. b) MasterPeace combined with ceiling-suspended lead screen, compared to standard radiation protection consisting of a table-side curtain for lower body protection (Kenex, UK) and ceiling-suspended lead screen. Scatter radiation was measured at various operator heights (70, 130 and 160 cm) across seven routine projection angles using a biplane angio-suite (Artis zee, Siemens Healthineers, Germany). Results (a) The mean scatter radiation shielding effect was 98.5% compared to no shielding across all measured heights and angular projections when used in combination with a ceiling-suspended lead screen. (b) The mean scatter radiation shielding effect was 79.7% compared to standard radiation protection for all measured heights and angular projections. The shielding efficacy ranged from 93.1% for the PA projection to 31.8% for LAO30/CAU30; and from 87.0% at 70 cm to 39.5% at 160 cm. Conclusions This phantom study demonstrates that the MasterPeace is highly effective and provides relevant radiation protection in addition to existing standard and personal protection equipment. Clinical evaluation in INR procedures is underway.

  • Open Access

    Structured Training in Modules E and F—A Success Story in Interventional Neuroradiology in Germany

    by Stefan Rohde, Ansgar Berlis, Werner Weber, Peter Schramm

  • Open Access

    Radiation Exposure in Interventional Stroke Treatment

    by Felix Bärenfänger, Peter Schramm, Stefan Rohde

    Purpose: To evaluate patient-related radiation exposure in interventional stroke treatment by analyzing data from the German Society for Interventional Radiology and Minimally Invasive Therapy (DeGIR) and the German Society of Neuroradiology (DGNR) quality registry from 2019–2021. Methods: The DeGIR/DGNR registry is the largest database of radiological interventions in Germany. Since the introduction of the registry in 2012, the participating hospitals have entered clinical and dose-related data on the procedures performed. To evaluate the current diagnostic reference level (DRL) for mechanical thrombectomy (MT) in stroke patients, we analyzed interventional data from 2019 to 2021 with respect to the reported dose area product (DAP) and factors that might contribute to the radiation dose, such as the localization of the occlusion, technical success using the modified treatment in cerebral ischemia (mTICI) score, number of passages, technical approach, additional intracranial/extracranial stenting, and case volume per center. Results: A total of 41,538 performed MTs from 180 participating hospitals were analyzed. The median DAP for MT was 7337.5 cGy∙cm2 and the corresponding interquartile range (IQR) Q25 = 4064 cGy∙cm2 to Q75 = 12,263 cGy∙cm2. In addition, we discovered that the dose was significantly influenced by occlusion location, number of passages, case volume per center, recanalization score, and additional stenting. Conclusion: We conducted a retrospective study on radiation exposure during MT in Germany. Based on the results of more than 41,000 procedures, we observed that the DRL of 14,000 cGy·cm2 is currently appropriate but may be lowered over the next years. Furthermore, we identified several factors that contribute to high radiation exposure. This can aid in detecting the cause of an exceeded DRL and optimize the treatment workflow.


  • Künstliche Intelligenz in der orthopädisch-unfallchirurgischen Radiologie

    by Stefan Rohde, Nico Münnich

    Zusammenfassung Künstliche Intelligenz (KI) spielt eine zunehmende Rolle für die radiologische Bildgebung in der Orthopädie und Unfallchirurgie. Die bislang verfügbaren Algorithmen finden überwiegend in der Detektion von (okkulten) Frakturen und in der Längen- und Winkelbestimmung bei konventionellen Röntgenaufnahmen Anwendung. Aktuelle KI-Lösungen ermöglichen aber auch die Analyse und Mustererkennung von CT-Datensätzen, zum Beispiel bei der Detektion von Rippen- oder Wirbelkörperfrakturen. Eine besondere Anwendung ist das EOS™ (ATEC Spine Group, Paris, Frankreich), dass auf der Basis einer digitalen 2‑D-Röntgenaufnahme eine 3‑D-Simulation des Achsenskeletts und semiautomatische Längen- und Winkelberechnungen ermöglicht. In der vorliegenden Arbeit wird das derzeitige Spektrum der KI-Anwendungen für die Orthopädie und Unfallchirurgie vorgestellt und diskutiert.


  • Mechanical thrombectomy for acute ischemic stroke in COVID-19 patients: multicenter experience in 111 cases

    by Hanna Styczen, Volker Maus, Lukas Goertz, Martin Köhrmann, Christoph Kleinschnitz, Sebastian Fischer, Markus Möhlenbruch, Iris Mühlen, Bernd Kallmünzer, Franziska Dorn, et al.

    Background Data on the frequency and outcome of mechanical thrombectomy (MT) for large vessel occlusion (LVO) in patients with COVID-19 is limited. Addressing this subject, we report our multicenter experience. Methods A retrospective cohort study was performed of consecutive acute stroke patients with COVID-19 infection treated with MT at 26 tertiary care centers between January 2020 and November 2021. Baseline demographics, angiographic outcome and clinical outcome evaluated by the modified Rankin Scale (mRS) at discharge and 90 days were noted. Results We identified 111 out of 11 365 (1%) patients with acute or subsided COVID-19 infection who underwent MT due to LVO. Cardioembolic events were the most common etiology for LVO (38.7%). Median baseline National Institutes of Health Stroke Scale score and Alberta Stroke Program Early CT Score were 16 (IQR 11.5–20) and 9 (IQR 7–10), respectively. Successful reperfusion (mTICI ≥2b) was achieved in 97/111 (87.4%) patients and 46/111 (41.4%) patients were reperfused completely. The procedure-related complication rate was 12.6% (14/111). Functional independence was achieved in 20/108 (18.5%) patients at discharge and 14/66 (21.2%) at 90 days follow-up. The in-hospital mortality rate was 30.6% (33/108). In the subgroup analysis, patients with severe acute COVID-19 infection requiring intubation had a mortality rate twice as high as patients with mild or moderate acute COVID-19 infection. Acute respiratory failure requiring ventilation and time interval from symptom onset to groin puncture were independent predictors for an unfavorable outcome in a logistic regression analysis. Conclusion Our study showed a poor clinical outcome and high mortality, especially in patients with severe acute COVID-19 infection undergoing MT due to LVO.


  • Clinical evaluation of a novel head protection system for interventional radiologists

    by Felix Bärenfänger, Jörg Walbersloh, Rachid El Mouden, Fabian Goerg, Andreas Block, Stefan Rohde


  • Open Access

    Acute Endovascular Stroke Treatment in Germany in 2019

    by German Society Of Interventional Radiology And Minimal Invasive Therapy, S. Rohde, German Society of Interventional Radiology and Minimal Invasive Therapy (DeGIR) and the German Society of Neuroradiology (DGNR), W. Weber, A. Berlis, H. Urbach, P. Reimer, P. Schramm

    Purpose: Since the incidental discovery and systematic introduction of mechanical endovascular stroke treatment in 2015 there are few reports about the real-life situation in daily clinical practice. The aim of this study was to evaluate the mechanical thrombectomy data documented in the quality assurance database of the German Society for Interventional Radiology and Minimally Invasive Therapy (DeGIR) and the German Society of Neuroradiology (DGNR) in 2019. Methods: We retrospectively analyzed the clinical and procedural data of all mechanical thrombectomies that were entered into the voluntary nationwide database in 2019. The information of each procedure was provided on a standardized web-based data sheet. Data were exported and analyzed by a group of experts on behalf of the DGNR. Results: A total of 13,840 data sets from 158 participating centers could be analyzed. Mean age of the patients was 74 ± 13 years; 53.9% were female. Vessel occlusion was located in the anterior circulation in 87.4%, in the posterior circulation in 10.7%. On hospital admission, the median National Institutes of Health Stroke Scale (NIHSS) was 14 (lower/upper quartile 10/19); at hospital discharge, median NIHSS had dropped to 9 (lower/upper quartile 2/12; p < 0.001). Recanalization of the occluded vessel segment was successful (TICI 2b + 3) in 88.4%. The reported complication rate was 7.3%, with subarachnoid hemorrhage as the most frequent complication (3.4%), followed by parenchymal hemorrhage (1.7%) and embolization in new territories (1.2%). Overall, the median time interval from symptom onset to hospital admission was 94 min (quartiles 59/180 min), the median time from hospital admission to groin puncture was 74 min (lower/upper quartile 47/103 min), and the median duration of the procedure 43 min (lower/upper quartile 25.2/73.2 min). A comparison between primary and secondary referral revealed a significant faster symptom-to-intervention time for primary referrals, whereas in-house workflows showed no significant difference. Conclusion: The analysis represents the largest documented cohort of acute stroke patients treated by thrombectomy. The documentation allows for a detailed evaluation of procedural, clinical, logistic and radiation exposure data and might be used for monitoring the quality of the treatment on a nationwide scale.


  • Effect of General Anaesthesia versus Conscious Sedation on Clinical and Procedural Outcome in Patients Undergoing Endovascular Stroke Treatment: A Matched-Pair Analysis

    by Stefan Rohde, Stephan Schwarz, Maria Alexandrou, Gernot Reimann, Richard Klaus Ellerkmann, Maria Politi, Andreas Kastrup, Panagiotis Papanagiotou

    Introduction: General anaesthesia (GA) during mechanical thrombectomy (MT) might lead to an inferior clinical outcome compared to conscious sedation (CS). It was hypothesised that using CS might avoid a critical drop in cerebral perfusion, shorten the time of the intervention and therefore might result in better clinical outcome. In this study, we compared the procedural and clinical results of patients who underwent MT under GA or CS at two tertiary neuro-vascular centres on the basis of a matched-pair analysis. Methods: Using a matched-pair approach, we compared the data of 56 patients that were treated under CS at centre A (n = 28) with selected patients who were treated under GA at the centre B (n = 28). Patients were matched for age, sex, site of vessel occlusion, NIHSS at admission (±3 points), time from symptom onset to initial stroke imaging, intravenous-lysis and co-morbidities. All patients had an ASPECT-score of ≥8. To exclude the effect of technical failures, only patients with successful recanalization of the occluded vessel (TICI 2b and 3) were included into the study. The primary endpoint was the proportion of patients with early good clinical outcome after MT, defined by a modified Ranking Scale (mRS)-score ≤2 at discharge. Secondary endpoints were the time from symptom onset to the start of the procedure, the duration of the procedure and the rate of procedural complications. Results: There were no differences concerning gender, age, the site of vessel occlusion and the degree of stroke severity at baseline. The proportion of patients with an early good clinical outcome (mRS ≤2 at discharge) was 60.4% (17/28) in both groups. The time from symptom onset to the start of the procedure was shorter at centre B, while the duration of the procedure was significantly faster at A, resulting in an overall time from symptom onset to complete recanalization of 152.2 ± 68.0 min for patients treated at centre A and 171.1 ± 43.5 min for patients at centre B (ns). Conclusion: Our study revealed no differences in the investigated clinical outcome for patients undergoing endovascular stroke treatment under GA versus CS.