Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hossein Ghadamian has a total of 90 co-authors. Here are the top co-authors by number of shared publications:

  • Mohammad Aminy

    Department of Energy, Materials and Energy Research Center (MERC), Tehran, Iran

    6 shared publications
  • H. A. Ozgoli

    Department of Mechanical Engineering, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran

    5 shared publications
  • Hassan Ali Ozgoli

    Department of Mechanical Engineering, Iranian Research Organization for Science and Technology (IROST), Tehran, Islamic Republic of Iran

    5 shared publications
  • Leila Seidabadi

    Department of Energy, Materials and Energy Research Center, Karaj, Iran

    4 shared publications
  • Meisam Moghadasi

    Mat & Energy Res Ctr, Dept Energy, Karaj, Iran

    4 shared publications
  • Mojtaba Baghban Yousefkhani

    Mat & Energy Res Ctr, Dept Energy, Karaj, Iran

    4 shared publications

Latest Publications

  • Prediction of outlet air characteristics and thermal performance of a symmetrical solar air heater via machine learning to develop a model-based operational control scheme—an experimental study

    by Meisam Moghadasi, Hossein Ghadamian, Mohammad Moghadasi, Leila Seidabadi

    This study develops reliable and robust machine learning (ML) models to predict the outlet air temperature and humidity and thermal efficiency of a solar air heater (SAH). Also, the application of predictive models for optimal control of the SAH operation is proposed. For this, the work contains three main parts: (a) a vertically-mounted symmetrical SAH was installed outside of a building room and operated throughout the winter of 2022. (b) By conducting experiments for five air mass flow rates, a large dataset with more than 62,500 sample points was collected. (c) Six input features containing time, environmental-related attributes, and SAH variables were applied to develop several state-of-the-art ML algorithms. To figure out the most accurate models for predicting output variables, the dataset was partitioned into three parts. Also, various modeling performance evaluation criteria were calculated and compared on the validation and test sets. Among these models, the gradient boosting machine algorithm based on LightGBM implementation achieved the best degree of generalization in modeling the target variables. The results demonstrated that the developed models obtained the lowest R-squared and the highest mean absolute percentage error of 0.9827 and 2.95%, respectively, on the test set. Moreover, the offline analysis of SAH operation based on the proposed control scheme demonstrated that 350 kWh of thermal energy can be generated during the application in the one-year winter season, 24% more than SAH operation without a model-based control strategy.


  • Simulation and experimental investigation of an organic phase change material-based air-cooling system for industrial applications in the hot climate

    by Leila Seidabadi, Hossein Ghadamian, Mohammad Aminy, Meisam Moghadasi, Shahriar Ghahremanian

    This work proposes a novel cooling system of the inlet air for industrial applications in the hot climates using organic phase change material. This cooling system consists of an inductive fan, an underground heat exchanger including double pipe phase change material. A three-dimensional transient simulation was developed to predict cooling capacity (temperature drop) using the analytical solution method within the MATLAB open-source code software. A prototype of the system was designed, built and tested in laboratory conditions to validate the modeling results. The experimental setup shows an average temperature reduction of 6°C in the air-cooling system in nine working hours, which matches with the simulation results with a variance of less than 2%. Further simulations demonstrated that an industrial scale could reduce the average temperature of intake air to 10°C in 7 hours working. The offline analysis proved a significant energy conservation opportunity in power plants. This study showed that energy performance and power generation of an industrial-scale gas turbine can be improved by 1% and 1.2 MW, respectively.


  • Applying machine learning techniques to implement the technical requirements of energy management systems in accordance with ISO 50001:2018, an industrial case study

    by Meisam Moghadasi, Nima Izadyar, Amirali Moghadasi, Hossein Ghadamian

    This article developed an innovative data-driven framework utilizing machine learning models to implement effective energy management systems in the energy-intensive industries to comply with ISO 50001:2018. By implementing this three-level framework, the following standard’s requirements are fulfilled: (a) indicating the variables that significantly affect energy performance, (b) energy performance indicator and energy baseline development, (c) analysis of the current energy performance, (d) energy conservation opportunity quantification, (e) determining the energy target, and (f) defining the energy action plan. The proposed data-driven energy management approach was implemented in an industrial-scale ethane decarbonization unit in South Pars Gas Complex in Iran. The dataset consists of 52,560 records of unit states sampled throughout 2020 as a baseline period. A high-accuracy model with 99% R-squared is developed by applying the Gradient Boosting Machines algorithm to predict the unit’s energy consumption as an energy baseline. As a critical finding, the offline analysis reveals a great potential to save energy by 10.31% or 63,119 metric tons of yearly steam consumption decreasing and a reduction of 7,027 tons of carbon dioxide emissions per year. By adjusting the unit working modes to the best practices, as an action plan, the intended outcome would be achievable.


  • Open Access

    Techno-Economic Analysis and New Design of a Photovoltaic Power Plant by a Direct Radiation Amplification System

    by Hamed Khodayar Sahebi, Siamak Hoseinzadeh, Hossein Ghadamian, Mohammad Hadi Ghasemi, Farbod Esmaeilion, Davide Astiaso Garcia

    Today, photovoltaic panels are used in various applications, and increasing their efficiency is of interest to many researchers. In this research, we try to increase the radiation density by increasing direct radiation to finally increase the energy production in photovoltaic power plants. The direct radiation amplification system is used to improve the photovoltaic efficiency. In this proposed system, energy and economics are analyzed by MATLAB software. Also, prototype testing and photovoltaic power plant testing are examined. The results show that by implementing this system in photovoltaic power plants, annual energy production can be increased. By adding this system to a photovoltaic power plant, the price of electricity produced in photovoltaic power plants will be increased from 13 ¢/kWh to 9 ¢/kWh, which shows a 31% reduction in the price of electricity per kilowatt-hour.


  • Open Access

    Investigation of the Fuel Utilization Factor in PEM Fuel Cell Considering the Effect of Relative Humidity at the Cathode

    by Mojtaba Baghban Yousefkhani, Hossein Ghadamian, Keyvan Daneshvar, Nima Alizadeh, Brendy C. Rincon Troconis

    This research consists of both theoretical and experimental sections presenting a novel scenario for the consumption of hydrogen in the polymer electrolyte membrane fuel cell (PEMFC). In the theory section, a new correction factor called parameter δ is used for the calculation of fuel utilization by introducing concepts of “useful water” and “non-useful water”. The term of “useful water” refers to the state that consumed hydrogen leads to the production of liquid water and external electric current. In the experimental section, the effect of the relative humidity of the cathode side on the performance and power density is investigated by calculating the parameter δ and the modified fuel utilization at 50% and 80% relative humidity. Based on the experimental results, the maximum power density obtained at 50% and 80% relative humidity of the cathode side is about 645 mW/cm2 and 700 mW/cm2, respectively. On the other hand, the maximum value of parameter δ for a value of 50% relative humidity in the cathode side is about 0.88, while for 80% relative humidity it is about 0.72. This means that the modified fuel utilization for 50% relative humidity has a higher value than that for 80%, which is not aligned with previous literature. Therefore, it is necessary to find an optimal range for the relative humidity of the cathode side to achieve the best cell performance in terms of the power generation and fuel consumption as increasing the relative humidity of the cathode itself cannot produce the best result.


  • Open Access

    Simulation of a GEF5 Gas Turbine Power Plant Using Fog Advanced Cycle and a Systematic Approach to Calculate Critical Relative Humidity

    by S. M. Arabi, H. Ghadamian, M. Aminy, H. A. Ozgoli, B. Ahmadi, M. Khodsiani

    The ambient conditions have a significant effect on the generated power and efficiency of gas turbines [1]. These variations considerably affect power generation, fuel consumption, power plant emissions, and plant incomes. However, cooling the compressor inlet air has been widely used to reduce this deficiency [2]. In this paper, by simulating a specific gas unit in Thermoflow software, the effect of the FOG system on it was studied. Considering the error in determining the capacity of cooling systems based on the average values of dry and wet bulb temperatures, or even considering the worst possible temperature and humidity conditions, it is advisable to use ECDH or Evaporation cooling Degree Hours. Accordingly, by calculating ECDH under at ambient temperatures above 15 °C and changing the conditions of the model, the total production increase of the unit was estimated to be 4.7×106 kWh. In addition, the effect of relative humidity on payback time was examined, which illustrated the critical relative humidity for a gas unit would depend on the price of fuel, the purchase price of electricity, the design parameters of the unit and the expected payback time. For this gas unit, critical relative humidity was monitored based on expected payback time and electricity purchase price. Results showed that for a certain electricity price, at the shorter PBT, the critical RH is lower; therefore, the temperature drop and power enhancement will be greater. In addition, at a certain PBT, as the electricity price increases, the critical RH for the same PBT will be higher.


  • Open Access

    Quantitative trade-off analysis of infrared light absorber effects contributed to photovoltaic cells performance

    by Shahrzad Bahrizadeh, Hossein Ghadamian, Mohammad Aminy, Ali Hosseini Rad, Maryam Azadeh

    It is widely known that organic and inorganic coatings absorb more of the solar spectrum, and due to a considerable share of 45% infrared radiation, the energy efficiency drop by the increasing of temperature should be considered. The purpose of this study is to implement a system to characterize silicon solar cell performance and increasing energy efficiency by imposing such coatings as infrared wave absorber to overcome the Shockley–Queisser limit. In other words, this research efforts to improve cell efficiency (coating effects) in addition to imposing the efficiency decreasing effects (temperature increasing). The core of the study is laboratory and experimental set-up measurements to find an organic absorber with the highest absorbance. Ruthenium-based dye, N719, has shown the best performance in experimental conditions and heat extraction to enhance cell energy efficiency. Due to increased absorption in a solar cell (SC), to control the temperature rise of the system, the fan is used as a cooling system. The imposing of N719 results in increasing energy efficiency by up to 1.38%. It is worth noting that a 1.60% increase in energy efficiency is observed due to temperature reduction by 2 degrees.


  • Open Access

    Energy and Exergy Evaluation of Multi-channel Photovoltaic/Thermal Hybrid System: Simulation and Experiment

    by Ali Hosseini Rad, H Ghadamian, Hamid Reza Haghgou, Faramarz Sarhadi

    In this research, a pilot study and analysis of an innovative multi-channel photovoltaic/thermal (MCPV/T) system in a geographic location (35° 44' 35'' N, 50° 57' 25'' E) has been carried out. This system consists of integrating a photovoltaic panel and two PV/T heat-sink converters. The total electrical, exergy and energy efficiencies of the system at air flow rate of 0.005 kg/s and radiation intensity of 926 w/m2 were 9.73%, 10.72%, and 47.24%, respectively. An air flow rate of 0.011 kg/s and the radiation intensity of 927 w/m2 were also achieved to be 9.35%, 10.40% and 65.10%, respectively. Based on simulation results considering experiments validations, as the air flow rate increases, the overall energy efficiency increases to the maximal amount of 80%. However, the maximum exergy efficiency value has a local optimal point of 13.46% at a fluid flow rate of 0.024 kg/s. Similarly, with increasing channel heights, the total energy efficiency decreased to 70%, and the maximum exergy efficiency has a local optimal point of 13.64% at channel height of 0.011 m. As an overall achievement, the system has higher energy quality (exergy efficiency) in laminar flow regime and has higher energy efficiency under turbulent flow conditions. First published in 1988, International Journal of Engineering (IJE) is multidisciplinary science journal published in three quarterly transactions.