Adolfo Ferrero Guadagnoli
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Adolfo Ferrero Guadagnoli has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Francesco Maisano
Department of Cardiac Surgery and Valve Center, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
3 shared publications Edwin Ho
A University Heart Center , University Hospital , Zurich , Switzerland
2 shared publicationsFabian Nietlispach
B Cardiology , University Hospital of Zurich , Zurich , Switzerland
2 shared publicationsMarco Luciani
A University Heart Center , University Hospital , Zurich , Switzerland
2 shared publications- Matteo Saccocci
Heart Valve Center, IRCCS San Raffaele Hospital, Milan, Italy; Cardiac Surgery Unit, Poliambulanza Foundation Hospital, Brescia, Italy
2 shared publications Maurizio Taramasso
A University Heart Center , University Hospital , Zurich , Switzerland
2 shared publications
Latest Publications
- Open Access
- 1 December 2020
- Published by Universidad Nacional de Córdoba in Revista de la Facultad de Ciencias Médicas de Córdoba
- Vol. 77 (4) , 281-284
Validación de percentil 99 de troponina ultrasensible obtenido en la población de un hospital general
El dosaje de troponina ultrasensible (TnT US) se recomienda para el diagnóstico de infarto de miocardio, para lo cual se utiliza como punto de corte el percentil 99 (p99) obtenido por el fabricante (99F) en población sana. El objetivo de este estudio es validar el p99 obtenido en la población de este hospital (99L) frente al 99F, utilizando la cinecoronariografía (CCG) como gold standard. Materiales y métodos: análisis retrospectivo de TnT US Roche realizada a todos los pacientes que ingresaron por SCA (síndrome coronario agudo) a los que se les realizó CCG entre 2015 y 2018. Se utilizó para el procesamiento estadístico el programa IBM SPSS Statistics 24 y tablas de sensibilidad y especificidad para métodos diagnósticos (EviCardio). Resultados: se incluyeron 415 pacientes, 118 de sexo femenino, con edad de 64,2 ± 12,5 años. La sensibilidad del 99F para diagnóstico de enfermedad coronaria severa (obstrucción ≥ 70%) fue de 83,6% y la especificidad, 44,5%. El valor predictivo positivo (VPP) fue de 77% y el negativo (VPN) 55%. La sensibilidad del 99L se calculó en 69,7% y la especificidad, 58,6%. El VPP fue 79% y el VPN 46%. El ABC (área bajo la curva) resultó ser 0,641 para el 99Fy 0,641 para el 99L. Conclusiones: Debido a la importancia de la sensibilidad en el uso de la TnT US como herramienta diagnóstica ante la sospecha de SCA, debemos seguir utilizando el 99F ya que mostró mayor sensibilidad que 99L (aunque menor a la reportada en estudios previos).
- 1 December 2020
- Published by Universidad Nacional de Córdoba in Revista de la Facultad de Ciencias Médicas de Córdoba
- Vol. 77 (4) , 281-284
Open AccessValidación de percentil 99 de troponina ultrasensible obtenido en la población de un hospital general
El dosaje de troponina ultrasensible (TnT US) se recomienda para el diagnóstico de infarto de miocardio, para lo cual se utiliza como punto de corte el percentil 99 (p99) obtenido por el fabricante (99F) en población sana. El objetivo de este estudio es validar el p99 obtenido en la población de este hospital (99L) frente al 99F, utilizando la cinecoronariografía (CCG) como gold standard. Materiales y métodos: análisis retrospectivo de TnT US Roche realizada a todos los pacientes que ingresaron por SCA (síndrome coronario agudo) a los que se les realizó CCG entre 2015 y 2018. Se utilizó para el procesamiento estadístico el programa IBM SPSS Statistics 24 y tablas de sensibilidad y especificidad para métodos diagnósticos (EviCardio). Resultados: se incluyeron 415 pacientes, 118 de sexo femenino, con edad de 64,2 ± 12,5 años. La sensibilidad del 99F para diagnóstico de enfermedad coronaria severa (obstrucción ≥ 70%) fue de 83,6% y la especificidad, 44,5%. El valor predictivo positivo (VPP) fue de 77% y el negativo (VPN) 55%. La sensibilidad del 99L se calculó en 69,7% y la especificidad, 58,6%. El VPP fue 79% y el VPN 46%. El ABC (área bajo la curva) resultó ser 0,641 para el 99Fy 0,641 para el 99L. Conclusiones: Debido a la importancia de la sensibilidad en el uso de la TnT US como herramienta diagnóstica ante la sospecha de SCA, debemos seguir utilizando el 99F ya que mostró mayor sensibilidad que 99L (aunque menor a la reportada en estudios previos).
- 12 February 2020
- Published by Springer Nature
- p. 455-462
Transcatheter Mitral Valve Therapies
- 3 June 2018
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 15 (6) , 415-421
Cardioband system as a treatment for functional mitral regurgitation
Are the current data on the Cardioband in the clinical area enough to consider it a tool for mitral regurgitation treatment? Severe secondary mitral valve insufficiency frequently affects high-risk surgical patients. The Cardioband system is a novel percutaneous surgical-like device for direct annuloplasty. It is implanted into the beating heart by transvenous femoral access, with minimal impact on hemodynamic and cardiac function during implantation. So far, it has demonstrated safety and feasibility in high-risk patients with functional mitral regurgitation; it has imparted significant annular reduction and regurgitation improvements. In well-selected patients, it could be an option for mitral valve repair. This is a bibliographic review based on scientific publications and medical congress reports. It includes the most current information related to Cardioband in mitral regurgitation. This novel, less-invasive and effective tool is an option for the open repair or replacement of the mitral valve in high-risk surgical patients. Although the current results of Cardioband are promising, more data and longer follow-up times are necessary to confirm its safety and efficacy and to evaluate the durability of the results.
- 3 June 2018
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 15 (6) , 415-421
Cardioband system as a treatment for functional mitral regurgitation
Are the current data on the Cardioband in the clinical area enough to consider it a tool for mitral regurgitation treatment? Severe secondary mitral valve insufficiency frequently affects high-risk surgical patients. The Cardioband system is a novel percutaneous surgical-like device for direct annuloplasty. It is implanted into the beating heart by transvenous femoral access, with minimal impact on hemodynamic and cardiac function during implantation. So far, it has demonstrated safety and feasibility in high-risk patients with functional mitral regurgitation; it has imparted significant annular reduction and regurgitation improvements. In well-selected patients, it could be an option for mitral valve repair. This is a bibliographic review based on scientific publications and medical congress reports. It includes the most current information related to Cardioband in mitral regurgitation. This novel, less-invasive and effective tool is an option for the open repair or replacement of the mitral valve in high-risk surgical patients. Although the current results of Cardioband are promising, more data and longer follow-up times are necessary to confirm its safety and efficacy and to evaluate the durability of the results.
- 28 March 2018
- Published by Springer Nature in Indian Journal of Thoracic and Cardiovascular Surgery
- Vol. 34 (S2) , 133-143
Cardioband system: a novel percutaneous solution for atrioventricular valve insufficiency
- 28 March 2018
- Published by Springer Nature in Indian Journal of Thoracic and Cardiovascular Surgery
- Vol. 34 (S2) , 133-143
Cardioband system: a novel percutaneous solution for atrioventricular valve insufficiency
- Open Access
- 1 January 2017
- Published by Instituto Mexicano del Seguro Social in Archivos de Cardiología de México
- Vol. 87 (1) , 96-99
Multivessel spontaneous coronary artery dissection in a puerperal young woman
- 1 January 2017
- Published by Instituto Mexicano del Seguro Social in Archivos de Cardiología de México
- Vol. 87 (1) , 96-99
Open AccessMultivessel spontaneous coronary artery dissection in a puerperal young woman
- Open Access
- 30 June 2016
- Published by ClinMed International Library in International Journal of Clinical Cardiology
- Vol. 3 (1)
Spontaneous Coronary Artery Dissection: Report of 6 Cases and Literature Review
We present our recent casuistry on such an interesting issue as coronary dissections. Provide data to assist the diagnosis and treatment of this disease.
- 30 June 2016
- Published by ClinMed International Library in International Journal of Clinical Cardiology
- Vol. 3 (1)
Open AccessSpontaneous Coronary Artery Dissection: Report of 6 Cases and Literature Review
We present our recent casuistry on such an interesting issue as coronary dissections. Provide data to assist the diagnosis and treatment of this disease.
- 1 January 2014
- Vol. 74 (4) , 303-6
[Treatment of pulmonary vein stenosis secondary to radiofrequency ablation].
Isolation of the pulmonary veins by applying radiofrequency is an effective treatment for atrial fibrillation. One of the potential complications with higher clinical compromise utilizing this invasive technique is the occurrence of stenosis of one or more pulmonary veins. This complication can be treated by angioplasty with or without stent implantation, with an adequate clinical improvement, but with a high rate of restenosis.
- 1 January 2014
- Vol. 74 (4) , 303-6
[Treatment of pulmonary vein stenosis secondary to radiofrequency ablation].
Isolation of the pulmonary veins by applying radiofrequency is an effective treatment for atrial fibrillation. One of the potential complications with higher clinical compromise utilizing this invasive technique is the occurrence of stenosis of one or more pulmonary veins. This complication can be treated by angioplasty with or without stent implantation, with an adequate clinical improvement, but with a high rate of restenosis.