MTMarie Sand Traberg

Marie Sand Traberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marie Sand Traberg has a total of 73 co-authors. Here are the top co-authors by number of shared publications:

  • Jorgen Arendt Jensen

    Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark

    22 shared publications
  • Matthias Bo Stuart

    Department of Health Technology, Center for Fast Ultrasound Imaging, Technical University of Denmark, Lyngby, Denmark

    10 shared publications
  • Jacob Bjerring Olesen

    Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, Lyngby, Denmark; BK Medical, Herlev, Denmark

    8 shared publications
  • Michael Bachmann Nielsen

    Department of Radiology, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark

    7 shared publications
  • Borislav Gueorguiev Tomov

    Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, DK-2800 Lyngby, Denmark

    4 shared publications
  • Kristoffer Lindskov Hansen

    Department of Diagnostic Radiology, Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark

    4 shared publications

Latest Publications

  • Open Access

    Intra-Cardiac Flow from Geometry Prescribed Computational Fluid Dynamics: Comparison with Ultrasound Vector Flow Imaging

    by Rasmus Hvid, Matthias Bo Stuart, Jørgen Arendt Jensen, Marie Sand Traberg

    Purpose: This paper investigates the accuracy of blood flow velocities simulated from a geometry prescribed computational fluid dynamics (CFD) pipeline by applying it to a dynamic heart phantom. The CFD flow patterns are compared to a direct flow measurement by ultrasound vector flow imaging (VFI). The hypothesis is that the simulated velocity magnitudes are within one standard deviation of the measured velocities. Methods: The CFD pipeline uses computed tomography angiography (CTA) images with 20 volumes per cardiac cycle as geometry input. Fluid domain movement is prescribed from volumetric image registration using the CTA image data. Inlet and outlet conditions are defined by the experimental setup. VFI is systematically measured in parallel planes, and compared to the corresponding planes in the simulated time dependent three dimensional fluid velocity field. Results: The measured VFI and simulated CFD have similar flow patterns when compared qualitatively. A quantitative comparison of the velocity magnitude is also performed at specific regions of interest. These are evaluated at 11 non-overlapping time bins and compared by linear regression giving R2 = 0.809, SD = 0.060 m/s, intercept = − 0.039 m/s, and slope = 1.09. Excluding an outlier at the inlet, the correspondence between CFD and VFI improves to: R2 = 0.823, SD = 0.048 m/s, intercept = -0.030 m/s, and slope = 1.01. Conclusion: The direct comparison of flow patterns shows that the proposed CFD pipeline provide realistic flow patterns in a well-controlled experimental setup. The demanded accuracy is obtained close to the inlet and outlet, but not in locations far from these.


  • Precise Estimation of Intravascular Pressure Gradients

    by Lars Emil Haslund, Lasse Thurmann Jørgensen, Matthias Bo Stuart, Marie Sand Traberg, Jørgen Arendt Jensen

    This study presents a method for noninvasive pressure gradient estimation, which allows the detection of small pressure differences with higher precision compared to invasive catheters. It combines a new method for estimating the temporal acceleration of the flowing blood with the Navier–Stokes equation. The acceleration estimation is based on a double cross-correlation approach, which is hypothesized to minimize the influence of noise. Data are acquired using a 256-element, 6.5-MHz GE L3-12-D linear array transducer connected to a Verasonics research scanner. A synthetic aperture (SA) interleaved sequence with ${2} \times {12}$ virtual sources evenly distributed over the aperture and permuted in emission order is used in combination with recursive imaging. This enables a temporal resolution between correlation frames equal to the pulse repetition time at a frame rate of half the pulse repetition frequency. The accuracy of the method is evaluated against a computational fluid dynamic simulation. Here, the estimated total pressure difference complies with the CFD reference pressure difference, which yields an ${R}$ -square of 0.985 and an RMSE of 3.03 Pa. The precision of the method is tested on experimental data, measured on a carotid phantom of the common carotid artery. The volume profile used during measurement was set to mimic flow in the carotid artery with a peak flow rate of 12.9 mL/s. The experimental setup showed that the measured pressure difference changes from −59.4 to 31 Pa throughout a single pulse cycle. This was estimated with a precision of 5.44% (3.22 Pa) across ten pulse cycles. The method was also compared to invasive catheter measurements in a phantom with a 60% cross-sectional area reduction. The ultrasound method detected a maximum pressure difference of 72.3 Pa with a precision of 3.3% (2.22 Pa). The catheters measured a maximum pressure difference of 105 Pa with a precision of 11.2% (11.4 Pa). This was measured over the same constriction and with a peak flow rate of 12.9 mL/s. The double cross-correlation approach revealed no improvement compared to a normal differential operator. The method’s strength, thus, lies primarily in the ultrasound sequence, which allows precise and accurate velocity estimations, at which acceleration and pressure differences can be acquired.


  • Top Cited Papers
    Open Access

    Anatomic and Functional Imaging Using Row–Column Arrays

    by Jorgen Arendt Jensen, Mikkel Schou, Lasse Thurmann Jorgensen, Borislav G. Tomov, Matthias Bo Stuart, Marie Sand Traberg, Iman Taghavi, Sigrid Huesebo Oygaard, Martin Lind Ommen, Kitty Steenberg, et al.

    Row–column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article summarizes the current literature for RC imaging and demonstrates that full anatomic and functional imaging can attain a high quality using synthetic aperture (SA) sequences and modified delay-and-sum beamforming. Resolution can approach the diffraction limit with an isotropic resolution of half a wavelength with low sidelobe levels, and the field of view can be expanded by using convex or lensed RC probes. GPU beamforming allows for three orthogonal planes to be beamformed at 30 Hz, providing near real-time imaging ideal for positioning the probe and improving the operator’s workflow. Functional imaging is also attainable using transverse oscillation and dedicated SA sequence for tensor velocity imaging for revealing the full 3-D velocity vector as a function of spatial position and time for both blood velocity and tissue motion estimation. Using RC arrays with commercial contrast agents can reveal super-resolution imaging (SRI) with isotropic resolution below $20~ \mu \text{m}$ . RC arrays can, thus, yield full 3-D imaging at high resolution, contrast, and volumetric rates for both anatomic and functional imaging with the same number of receive channels as current commercial 1-D arrays.


  • Performance Assessment of Row–Column Transverse Oscillation Tensor Velocity Imaging Using Computational Fluid Dynamics Simulation of Carotid Bifurcation Flow

    by Lasse Thurmann Jorgensen, Marie Sand Traberg, Matthias Bo Stuart, Jorgen Arendt Jensen

    In this work, the accuracy of row–column tensor velocity imaging (TVI), i.e., 3-D vector flow imaging (VFI) in 3-D space over time, is quantified on a complex, clinically relevant flow. The quantification is achieved by transferring the flow simulated using computational fluid dynamics (CFD) to a Field II simulation environment, and this allows for a direct comparison between the actual and estimated velocities. The carotid bifurcation flow simulations were performed with a peak inlet velocity of 80 cm/s, nonrigid vessel walls, and a flow cycle duration of 1.2 s. The flow was simulated from two observation angles, and it was acquired using a 3-MHz 62+62 row–column addressed array (RCA) at a pulse repetition frequency ( ${f}_{prf}$ ) of 10 and 20 kHz. The tensor velocities were obtained at a frame rate of 208.3 Hz, at ${f}_{prf} = {10} ~\mathrm{kHz}$ , and the results from two velocity estimators were compared. The two estimators were the directional transverse oscillation (TO) cross correlation estimator and the proposed autocorrelation estimator. Linear regression between the actual and estimated velocity components yielded, for the cross correlation estimator, an ${R}$ 2 value in the range of 0.89–0.91, 0.46–0.77, and 0.91–0.97 for the ${x}$ -, ${y}$ -, and ${z}$ -components, and 0.87–0.89, 0.40–0.83, and 0.91–0.96 when using the autocorrelation estimator. The results demonstrate that an RCA can, with just 62 receive channels, measure complex 3-D flow fields at a high volume rate.


  • Open Access

    3D Volumetric Tensor Velocity Imaging with Low Computational Complexity Using a Row-Column Addressed Array

    by Kseniya Chetverikova, Jørgen Arendt Jensen, Marie Sand Traberg, Matthias Bo Stuart

    A method for volumetric Tensor Velocity Imaging employing row-column (RC) addressed array with low computational complexity is investigated in simulations. An interleaved and non-interleaved sliding aperture sequence with 11 rows and 11 columns emissions by a 62 + 62 RC addressed array was used. The 3D velocities were estimated by a transverse oscillation (TO) cross-correlation estimator. Parabolic profiles at six different orientations corresponding to combinations of 0, 45 degrees azimuth angles and 90, 75, 60 beam-to-flow angles were investigated with 5 kHz pulse repetition frequencies. The Field II simulations were performed at a depth of 30 mm with peak velocity of 0.3 m/s. Across all vessel orientations, the relative mean bias varied from 2.3% to −14.26%, and the relative standard deviation varied from 0.43% to 5.5%. The best and worst performance was found at beam to flow angles of 90 degrees with 0 degrees rotation angle and 60 degrees beam-to-flow angle with 45 degrees rotation angle respectively. Due to the low channel count of the RC array and the low computational complexity, real-time implementation is feasible on conventional ultrasound systems.


  • Flow Complexity Estimation in Dysfunctional Arteriovenous Dialysis Fistulas using Vector Flow Imaging

    by Tin-Quoc Nguyen, Marie Sand Traberg, Jacob Bjerring Olesen, Søren Thorup Heerwagen, Andreas Hjelm Brandt, Thor Bechsgaard, Brian Lindegaard Pedersen, Ramin Moshavegh, Lars Lönn, Jørgen Arendt Jensen, et al.


  • Fast 3-D Velocity Estimation in 4-D Using a 62 + 62 Row–Column Addressed Array

    by Mikkel Schou, Lasse Thurmann Jorgensen, Christopher Beers, Marie Sand Traberg, Borislav Gueorguiev Tomov, Matthias Bo Stuart, Jorgen Arendt Jensen

    This paper presents an imaging scheme capable of estimating the full 3-D velocity vector field in a volume using rowcolumn addressed (RCA) arrays at a high volume rate. A 62+62 RCA array is employed with an interleaved synthetic aperture sequence. It contains repeated emissions with rows and columns interleaved with B-mode emissions. The sequence contains 80 emissions in total and can provide continuous volumetric data at a volume rate above 125 Hz. A transverse oscillation crosscorrelation estimator determines all three velocity components. The approach is investigated using Field II simulations and measurements using a specially built 3 MHz 62+62 RCA array connected to the SARUS experimental scanner. Both the B-mode and flow sequences have a penetration depth of 14 cm when measured on a tissue mimicking phantom (0.5 dB/[MHz·cm] attenuation). Simulations of a parabolic flow in a 12 mm diameter vessel at a depth of 30 mm, beam-to-flow angle of 90°, and xyrotation of 45° gave a standard deviation (SD) of (3.3, 3.4, 0.4)% and bias of (-3.3, -3.9, -0.1)%, for (vx, vy, vz). Decreasing the beam-to-flow angle to 60° gave a SD of (8.9, 9.1, 0.8)% and bias of (-7.6, -9.5, -7.2)%, showing a slight increase. Measurements were carried out using a similar setup, and pulsing at 2 kHz yielded comparable results at 90° with a SD of (5.8, 5.5, 1.1)% and bias of (1.4, -6.4, 2.4)%. At 60° the SD was (5.2, 4.7 1.2)% and bias (-4.6, 6.9, -7.4)%. Results from measurements across all tested settings showed a maximum SD of 6.8% and a maximum bias of 15.8%, for a peak velocity of 10 cm/s. A tissue mimicking phantom with a straight vessel was used to introduce clutter, tissue motion, and a pulsating flow. The pulsating velocity magnitude was estimated across 10 pulse periods and yielded an SD of 10.9%. The method was capable of estimating transverse flow components precisely, but underestimated the flow with small beam-to-flow angles. The sequence provided continuous data in both time and space throughout the volume, allowing for retrospective analysis of the flow. Moreover, B-mode planes can be selected retrospectively anywhere in the volume. This shows that tensor velocity imaging (full 3-D volumetric vector flow imaging) can be estimated in 4-D (x,y,z,t) using only 62 channels in receive, making 4-D volumetric imaging implementable on current scanner hardware.


  • History and Latest Advances in Flow Estimation Technology: From 1-D in 2-D to 3-D in 4-D

    by Jorgen Arendt Jensen, Marie Sand Traberg, Tin-Quoc Nguyen, Erik Vilain Thomsen, Niels Bent Larsen, Christopher Beers, Borislav Gueorguiev Tomov, Michael Bachmann Nielsen, Svetoslav Ivanov Nikolov, Kristoffer Lindskov Hansen, et al.

    Ultrasound imaging of flow has seen a tremendous development over the last sixty years from 1-D spectral displays to color flow mapping and the latest Vector Flow Imaging (VFI). The paper gives an overview of the development from current commercial vector flow systems to the latest advances in fast 4-D volumetric visualizations. It includes a description of the radical break with the current sequential data acquisition by the introduction of synthetic aperture imaging, where the whole region of interest is insonified using either spherical or plane waves also known as ultrafast imaging. This makes it possible to track flow continuously in all directions at frame rates of thousands of images per second. The latest research translates this to full volumetric imaging by employing matrix arrays and row-column arrays for full 3-D vector velocity estimation at all spatial points visualized at very high volume rates (4-D).


  • Pressure Difference Estimation in Carotid Bulbs using Vector Flow Imaging - A Phantom Study

    by Tin-Quoc Nguyen, Marie Sand Traberg, Jacob Bjerring Olesen, Ramin Moshavegh, Peter Hasse Moller-Sorensen, Lars Lonn, Jorgen Arendt Jensen, Michael Bachmann Nielsen, Kristoffer Lindskov Hansen

    Hypertension is a common health problem and may be caused by dysfunction of the stretch sensitive baroreceptors in the carotid bulb. Velocity changes and vortices are present in the carotid bulb, and a better evaluation of the local flow and pressures may be important to further understand hypertension. The intravascular pressure catheter is a common tool in the clinic and is currently considered to be the reference standard for intravascular pressure measurement, but the method is invasive, ionizing, and has been reported to be inaccurate. Vector flow imaging (VFI) is an angle independent, noninvasive, and nonionizing ultrasound method that can estimate pressure differences. In this study, pressure differences between the common carotid artery and the carotid bulb obtained with VFI were compared with catheter measurements in three carotid bifurcation phantoms. A fluid-structure interaction (FSI) simulation model was used as reference. Additionally, 10 repeated VFI and catheter measurements were performed in one phantom for a precision assessment. The mean absolute pressure difference between the catheter and FSI method in the three phantoms was 140.5 Pa, and 10 repeated catheter tests measured a mean pressure decrease with a large variation (mean: -133.3 Pa, SD: 786%). VFI estimated pressure increases in all phantoms with a mean standard deviation of 11.6%, and the mean absolute pressure difference compared with FSI was 16.7 Pa. Ten repeated VFI estimations found a mean pressure increase with low variation (mean: 40.1 Pa, SD: 10.9%). VFI precisely estimated small pressure differences in a carotid bifurcation phantom setup, whereas the fluid-filled pressure catheter measurements were imprecise.