Seyed Reza Mahmoodi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Seyed Reza Mahmoodi has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Mehdi Javanmard
Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ 08854, USA
3 shared publications M. Mayer
Stevens Inst Technol, Dept Chem Engn & Mat Sci, Hoboken, NJ 07030 USA
2 shared publications- Mark. G. Allen
University of Pennsylvania
2 shared publications A. Khalatbari
School of Metallurgical and Materials Engineering, University of Tehran, Tehran, Iran
1 shared publication- Abdol-Reza Geranmayeh
Islamic Azad University
1 shared publication Alexis Abigail A. Alburo
Department of Bioengineering and California Institute for Quantitative Biosciences (QB3) University of California Berkeley CA 94720 USA
1 shared publication
Latest Publications
- Open Access
Automated Electrical Detection of Proteins for Oral Squamous Cell Carcinoma in an Integrated Microfluidic Chip Using Multi-Frequency Impedance Cytometry and Machine Learning
Proteins can act as suitable biomarkers for the prognosis and diagnosis of certain conditions and can help us gain an understanding of the fundamental processes that occur inside an organism. In this work, we present a fully automated machine learning-assisted label-free method for the electrical detection of proteins in an integrated microfluidic chip using multi-frequency impedance cytometry and off-the-shelf components for realizing an automated and programmable fluid control system. We verify the robustness of our mixing method on our custom microfluidic mixer composed of polydimethylsiloxane (PDMS) serpentine channels optically using a fluorescent sandwich immunoassay and comparing the results with a commercial benchtop mixer. Salivary IL-6 is a biomarker for oral squamous cell carcinoma (OSCC), and we have demonstrated that our system can be used for the detection of quantification of Interleukin-6 (IL-6) levels in a solution using the impedance response of beads conjugated with the protein of interest, which passes through the microfluidic chip with reasonable accuracy (96%). Although we have demonstrated the detection and quantification of IL-6, our system can be adapted to any protein of interest with slight modification in the reagents and bead-binding protocols.
Open AccessAutomated Electrical Detection of Proteins for Oral Squamous Cell Carcinoma in an Integrated Microfluidic Chip Using Multi-Frequency Impedance Cytometry and Machine Learning
Proteins can act as suitable biomarkers for the prognosis and diagnosis of certain conditions and can help us gain an understanding of the fundamental processes that occur inside an organism. In this work, we present a fully automated machine learning-assisted label-free method for the electrical detection of proteins in an integrated microfluidic chip using multi-frequency impedance cytometry and off-the-shelf components for realizing an automated and programmable fluid control system. We verify the robustness of our mixing method on our custom microfluidic mixer composed of polydimethylsiloxane (PDMS) serpentine channels optically using a fluorescent sandwich immunoassay and comparing the results with a commercial benchtop mixer. Salivary IL-6 is a biomarker for oral squamous cell carcinoma (OSCC), and we have demonstrated that our system can be used for the detection of quantification of Interleukin-6 (IL-6) levels in a solution using the impedance response of beads conjugated with the protein of interest, which passes through the microfluidic chip with reasonable accuracy (96%). Although we have demonstrated the detection and quantification of IL-6, our system can be adapted to any protein of interest with slight modification in the reagents and bead-binding protocols.
- Open Access
Vascular Microphysiological System for Investigating Endothelial Barrier Function During Organ Preservation and Reperfusion
Endothelial cell damage after cold preservation and reperfusion injury causes deterioration of the endothelial barrier and ultimately results in edema, leading to transplant failure. Here, a vascular microphysiological system ( MPS ) is introduced as a testbed to investigate the combinational effect of thermal and fluid perturbations (i.e., wall shear stress) on human endothelial barrier function. Two methods of organ storage are compared: isochoric supercooling ( ISC ) preservation, which prevents ice formation at subzero temperatures; and, the standard clinical protocol of static cold storage ( SCS ) at 4 °C. Integrating electrical impedance measurements on chip allow real‐time monitoring and quantification of barrier function during preservation and reperfusion protocols. Isochoric supercooling preservation enables longer periods of preservation with superior recovery of barrier function during reperfusion, and has lower metabolic activities compared to static cold storage. Genomic analysis reveals injury and recovery mechanisms at the molecular level for the different preservation and reperfusion conditions. The multifunctional vascular microphysiological system provides a physiologically relevant in vitro model recapitulating ischemia‐reperfusion injury to the endothelium. The vascular MPS has potential for optimizing organ preservation protocols, ultimately improving organ transplant viability.
Open AccessVascular Microphysiological System for Investigating Endothelial Barrier Function During Organ Preservation and Reperfusion
Endothelial cell damage after cold preservation and reperfusion injury causes deterioration of the endothelial barrier and ultimately results in edema, leading to transplant failure. Here, a vascular microphysiological system ( MPS ) is introduced as a testbed to investigate the combinational effect of thermal and fluid perturbations (i.e., wall shear stress) on human endothelial barrier function. Two methods of organ storage are compared: isochoric supercooling ( ISC ) preservation, which prevents ice formation at subzero temperatures; and, the standard clinical protocol of static cold storage ( SCS ) at 4 °C. Integrating electrical impedance measurements on chip allow real‐time monitoring and quantification of barrier function during preservation and reperfusion protocols. Isochoric supercooling preservation enables longer periods of preservation with superior recovery of barrier function during reperfusion, and has lower metabolic activities compared to static cold storage. Genomic analysis reveals injury and recovery mechanisms at the molecular level for the different preservation and reperfusion conditions. The multifunctional vascular microphysiological system provides a physiologically relevant in vitro model recapitulating ischemia‐reperfusion injury to the endothelium. The vascular MPS has potential for optimizing organ preservation protocols, ultimately improving organ transplant viability.
- 1 August 2021
- Published by Elsevier in Applied Energy
- Vol. 295
Rapid and simple assembly of a thin microfluidic fuel cell stack by gas-assisted thermal bonding
- 1 August 2021
- Published by Elsevier in Applied Energy
- Vol. 295
Rapid and simple assembly of a thin microfluidic fuel cell stack by gas-assisted thermal bonding
- Open Access
- 2 July 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (27) , eabf4401
Single-step label-free nanowell immunoassay accurately quantifies serum stress hormones within minutes
Single-step label-free nanowell array immunoassay accurately detects serum stress hormones within minutes at small volumes.
- 2 July 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (27) , eabf4401
Open AccessSingle-step label-free nanowell immunoassay accurately quantifies serum stress hormones within minutes
Single-step label-free nanowell array immunoassay accurately detects serum stress hormones within minutes at small volumes.
- 22 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 4 (2) , 1-4
Multiwell Plate Impedance Analysis of a Nanowell Array Sensor for Label-Free Detection of Cytokines in Mouse Serum
We present a novel method for label-free detection of tumor necrosis factor alpha (TNF-α) in serum after immobilization by electric field. Detection of proteins in blood using label-free impedance-based techniques is difficult due to high salt concentration of the matrix, which results in charge screening. The nanowell array sensor provides enhanced electrochemical sensitivity by electric field focusing in the nanoscale volume wells. Here, an on-chip multi-well plate sensing platform was fabricated and tested. The sensor performance through testing in mouse serum at protein concentrations between 10–500 ng/l has been demonstrated. This detection modality is advantageous to many label-free electronic sensors in that signal power scales with increase in salt concentration, thus improving the sensitivity of the platform.
- 22 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 4 (2) , 1-4
Multiwell Plate Impedance Analysis of a Nanowell Array Sensor for Label-Free Detection of Cytokines in Mouse Serum
We present a novel method for label-free detection of tumor necrosis factor alpha (TNF-α) in serum after immobilization by electric field. Detection of proteins in blood using label-free impedance-based techniques is difficult due to high salt concentration of the matrix, which results in charge screening. The nanowell array sensor provides enhanced electrochemical sensitivity by electric field focusing in the nanoscale volume wells. Here, an on-chip multi-well plate sensing platform was fabricated and tested. The sensor performance through testing in mouse serum at protein concentrations between 10–500 ng/l has been demonstrated. This detection modality is advantageous to many label-free electronic sensors in that signal power scales with increase in salt concentration, thus improving the sensitivity of the platform.
- 18 March 2019
- Published by Springer Nature in Microsystem Technologies
- Vol. 25 (10) , 3923-3932
Gas-assisted thermal bonding of thermoplastics for the fabrication of microfluidic devices
- 18 March 2019
- Published by Springer Nature in Microsystem Technologies
- Vol. 25 (10) , 3923-3932
Gas-assisted thermal bonding of thermoplastics for the fabrication of microfluidic devices
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 32nd IEEE/CPMT International Electronic Manufacturing Technology Symposium
- No. 10898190,p. 443-449
Indentation creep of lead-free Sn-Bi solder alloys as replacements of Sn-Pb used in microelectronic packaging
Creep behavior of three lead-free Sn-Bi alloys with 1-5 wt.% Bi, together with the Sn-37%Pb solder alloy as the material for comparison, was studied by Vickers indentation testing at room temperature. The stress exponents in the range 13-16, determined through different indentation methods, are in good agreement. The measured exponents imply that dislocation movement is the possible mechanism during room-temperature creep deformation of these solders alloys. All three tin-based alloys showed creep resistances higher than that of the Sn-37%Pb alloy. Creep resistance increased by increasing Bi content of the alloys.
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 32nd IEEE/CPMT International Electronic Manufacturing Technology Symposium
- No. 10898190,p. 443-449
Indentation creep of lead-free Sn-Bi solder alloys as replacements of Sn-Pb used in microelectronic packaging
Creep behavior of three lead-free Sn-Bi alloys with 1-5 wt.% Bi, together with the Sn-37%Pb solder alloy as the material for comparison, was studied by Vickers indentation testing at room temperature. The stress exponents in the range 13-16, determined through different indentation methods, are in good agreement. The measured exponents imply that dislocation movement is the possible mechanism during room-temperature creep deformation of these solders alloys. All three tin-based alloys showed creep resistances higher than that of the Sn-37%Pb alloy. Creep resistance increased by increasing Bi content of the alloys.