Elba Mauriz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Elba Mauriz has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
- Laura M. Lechuga
Nanobiosensors and Bioanalytical Applications Group (NanoB2A), Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, CIBER-BBN, and BIST, Campus UAB Bellaterra, 08193 Barcelona, Spain
14 shared publications A. Calle
Biosensors Group Microelectronics National Centre (CNM), CSIC, Madrid, Spain
9 shared publications- Ana Maria Vázquez Casares
Department of Nursing and Physiotherapy, University of Leon, 24071 León, Spain
9 shared publications A. Montoya
Centro de Investigación e Innovación en Bioingeniería, Universidad Politécnica de Valencia, Valencia, Spain
7 shared publications- Marı́a Camino Garcı́a-Fernández
Institute of Food Science and Technology (ICTAL), La Serna 58, 24007 León, Spain
6 shared publications - Juan José Manclús
Laboratorio Integrado de Bioingeniería, Universidad Politécnica de Valencia, Camino de Vera s/n, 46022 Valencia, Spain
5 shared publications
Latest Publications
- Open Access
- 17 July 2026
- Published by MDPI AG in Nursing Reports
- Vol. 16 (7) , 250
Validity and Internal Consistency of a Rubric for Cervical Collar Placement in Nursing Students
Background/Objectives: The assessment of clinical competencies in nursing education requires valid and reliable instruments, especially for essential procedures such as the placement of a cervical collar in the care of polytrauma patients. The objective of this study was to analyse the psychometric properties of a rubric designed to assess the placement of cervical collars in nursing students in a low-fidelity clinical simulation environment. Methods: A quasi-experimental, cross-sectional study was conducted with 186 undergraduate nursing students, organised into 61 groups, over three academic years (2021–2024). An eight-item rubric was applied, with a four-level Likert scale (1–4). Interrater reliability was analysed using Cohen’s Kappa index (0.418–0.796), internal consistency using Cronbach’s alpha (alpha = 0.753), and the internal structure of the instrument using exploratory factor analysis, applying Varimax orthogonal rotation. Results: Inter-rater reliability showed values ranging from moderate to substantial, with greater agreement observed in items related to the selection of the collar and the position of the medical team, and moderate agreement in those related to technical manoeuvres and immobilisation. The rubric showed adequate overall internal consistency (α = 0.76), with good to very good consistency values in six of the eight items. Exploratory factor analysis identified a two-dimensional structure with a dominant procedural factor (four items) and a second factor associated with clinical judgement (four items). Conclusions: The validated rubric has adequate levels of reliability and internal consistency for evaluating the placement of cervical collars by nursing students. Its application can promote more objective and structured evaluation processes in clinical simulation for nursing students, contributing to the development of essential skills in the care of polytrauma patients.
- 17 July 2026
- Published by MDPI AG in Nursing Reports
- Vol. 16 (7) , 250
Open AccessValidity and Internal Consistency of a Rubric for Cervical Collar Placement in Nursing Students
Background/Objectives: The assessment of clinical competencies in nursing education requires valid and reliable instruments, especially for essential procedures such as the placement of a cervical collar in the care of polytrauma patients. The objective of this study was to analyse the psychometric properties of a rubric designed to assess the placement of cervical collars in nursing students in a low-fidelity clinical simulation environment. Methods: A quasi-experimental, cross-sectional study was conducted with 186 undergraduate nursing students, organised into 61 groups, over three academic years (2021–2024). An eight-item rubric was applied, with a four-level Likert scale (1–4). Interrater reliability was analysed using Cohen’s Kappa index (0.418–0.796), internal consistency using Cronbach’s alpha (alpha = 0.753), and the internal structure of the instrument using exploratory factor analysis, applying Varimax orthogonal rotation. Results: Inter-rater reliability showed values ranging from moderate to substantial, with greater agreement observed in items related to the selection of the collar and the position of the medical team, and moderate agreement in those related to technical manoeuvres and immobilisation. The rubric showed adequate overall internal consistency (α = 0.76), with good to very good consistency values in six of the eight items. Exploratory factor analysis identified a two-dimensional structure with a dominant procedural factor (four items) and a second factor associated with clinical judgement (four items). Conclusions: The validated rubric has adequate levels of reliability and internal consistency for evaluating the placement of cervical collars by nursing students. Its application can promote more objective and structured evaluation processes in clinical simulation for nursing students, contributing to the development of essential skills in the care of polytrauma patients.
- Open Access
- 8 April 2026
- Published by MDPI AG in Preprints.org
Validity and Internal Consistency of a Rubric for Cervical Collar Placement in Nursing Students
Background/Objectives: The assessment of clinical competencies in nursing education requires valid and reliable instruments, especially for essential procedures such as the placement of a cervical collar in the care of polytrauma patients. The objective of this study was to analyze the psychometric properties of a rubric designed to assess the placement of cervical collars in nursing students in a low-fidelity clinical simulation environment. Methods: A quasi-experimental, cross-sectional study was conducted with 186 undergraduate nursing students, organized into 62 groups, over three academic years (2021–2024). An 8-item rubric was applied, with a 4-level Likert scale (1–4). Interrater reliability was analyzed using Cohen’s Kappa index, internal consistency using Cronbach’s alpha, and the internal structure of the instrument using exploratory factor analysis, applying Varimax orthogonal rotation. Results: Inter-rater reliability showed values ranging from moderate to substantial, with greater agreement observed in items related to the selection of the collar and the position of the medical team, and moderate agreement in those related to technical maneuvers and immobilization. The rubric showed adequate overall internal consistency (α = 0.76), with good to very good consistency values in 6 of the 8 items. Exploratory factor analysis identified a two-dimensional structure with a dominant procedural factor (4 items) and a second factor associated with clinical judgment (4 items). Conclusions: The validated rubric has adequate levels of reliability and internal consistency for evaluating the placement of cervical collars by nursing students. Its application can promote more objective and structured evaluation processes in clinical simulation for nursing students, contributing to the development of essential skills in the care of polytrauma patients.
- 8 April 2026
- Published by MDPI AG in Preprints.org
Open AccessValidity and Internal Consistency of a Rubric for Cervical Collar Placement in Nursing Students
Background/Objectives: The assessment of clinical competencies in nursing education requires valid and reliable instruments, especially for essential procedures such as the placement of a cervical collar in the care of polytrauma patients. The objective of this study was to analyze the psychometric properties of a rubric designed to assess the placement of cervical collars in nursing students in a low-fidelity clinical simulation environment. Methods: A quasi-experimental, cross-sectional study was conducted with 186 undergraduate nursing students, organized into 62 groups, over three academic years (2021–2024). An 8-item rubric was applied, with a 4-level Likert scale (1–4). Interrater reliability was analyzed using Cohen’s Kappa index, internal consistency using Cronbach’s alpha, and the internal structure of the instrument using exploratory factor analysis, applying Varimax orthogonal rotation. Results: Inter-rater reliability showed values ranging from moderate to substantial, with greater agreement observed in items related to the selection of the collar and the position of the medical team, and moderate agreement in those related to technical maneuvers and immobilization. The rubric showed adequate overall internal consistency (α = 0.76), with good to very good consistency values in 6 of the 8 items. Exploratory factor analysis identified a two-dimensional structure with a dominant procedural factor (4 items) and a second factor associated with clinical judgment (4 items). Conclusions: The validated rubric has adequate levels of reliability and internal consistency for evaluating the placement of cervical collars by nursing students. Its application can promote more objective and structured evaluation processes in clinical simulation for nursing students, contributing to the development of essential skills in the care of polytrauma patients.
- Open Access
- 16 February 2026
- Published by Elsevier in Food Bioscience
- Vol. 78
Propolis modulates microbial communities and enhances safety in Chorizo de León: A metataxonomic study
- 16 February 2026
- Published by Elsevier in Food Bioscience
- Vol. 78
Open AccessPropolis modulates microbial communities and enhances safety in Chorizo de León: A metataxonomic study
- Open Access
- 13 November 2025
- Published by Elsevier in SSRN Electronic Journal
Propolis modulates microbial communities and enhances safety in Chorizo de León: A metataxonomic study
- 13 November 2025
- Published by Elsevier in SSRN Electronic Journal
Open AccessPropolis modulates microbial communities and enhances safety in Chorizo de León: A metataxonomic study
- Open Access
- 12 April 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (4) , 245
Trends and Challenges of SPR Aptasensors in Viral Diagnostics: A Systematic Review and Meta-Analysis
Surface plasmon resonance (SPR) aptasensors benefit from the SPR phenomenon in measuring aptamer interactions with specific targets. Integrating aptamers into SPR detection enables extensive applications in clinical analysis. Specifically, virus aptasensing platforms are highly desirable to face the ongoing challenges of virus outbreaks. This study systematically reviews the latest advances in SPR aptasensors for virus detection according to PRISMA guidelines. The literature search recovered 322 original articles from the Scopus (n = 152), Web of Science (n = 83), and PubMed (n = 87) databases. The selected articles (29) deal with the binding events between the aptamers immobilized on the sensor surface and their target molecule: virus proteins or intact viruses according to different SPR configurations. The methodological quality of each study was assessed using QUADAS-2, and a meta-analysis was conducted with the CochReview Manager (RevMan) Edition7.12.0 Data were analyzed, focusing on the types of viruses, the virus target, and the reference method. The pooled sensitivity was 1.89 (95%, CI 1.29, 2.78, I2 = 49%). The analysis of different types of plasmonic sensors showed the best diagnostic results with the least heterogeneity for SPR conventional configurations: 3.23 (95% CI [1.80, 5.79]; I2 = 0%, p = 0.65). These findings show that even though plasmonic biosensors effectively analyze viruses through aptamer approaches, there are still big challenges to using them regularly for diagnostics. Practical considerations for measuring label-free interactions revealed functional capabilities, technological boundaries, and future outlooks of SPR virus aptasensing.
- 12 April 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (4) , 245
Open AccessTrends and Challenges of SPR Aptasensors in Viral Diagnostics: A Systematic Review and Meta-Analysis
Surface plasmon resonance (SPR) aptasensors benefit from the SPR phenomenon in measuring aptamer interactions with specific targets. Integrating aptamers into SPR detection enables extensive applications in clinical analysis. Specifically, virus aptasensing platforms are highly desirable to face the ongoing challenges of virus outbreaks. This study systematically reviews the latest advances in SPR aptasensors for virus detection according to PRISMA guidelines. The literature search recovered 322 original articles from the Scopus (n = 152), Web of Science (n = 83), and PubMed (n = 87) databases. The selected articles (29) deal with the binding events between the aptamers immobilized on the sensor surface and their target molecule: virus proteins or intact viruses according to different SPR configurations. The methodological quality of each study was assessed using QUADAS-2, and a meta-analysis was conducted with the CochReview Manager (RevMan) Edition7.12.0 Data were analyzed, focusing on the types of viruses, the virus target, and the reference method. The pooled sensitivity was 1.89 (95%, CI 1.29, 2.78, I2 = 49%). The analysis of different types of plasmonic sensors showed the best diagnostic results with the least heterogeneity for SPR conventional configurations: 3.23 (95% CI [1.80, 5.79]; I2 = 0%, p = 0.65). These findings show that even though plasmonic biosensors effectively analyze viruses through aptamer approaches, there are still big challenges to using them regularly for diagnostics. Practical considerations for measuring label-free interactions revealed functional capabilities, technological boundaries, and future outlooks of SPR virus aptasensing.
- Open Access
- 2 April 2025
- Published by Elsevier in Journal of Molecular Biology
- Vol. 437 (12) , 169117
Adaptive SELEX Strategies Against HCV Core Protein Lead to the Same Aptamer
- 2 April 2025
- Published by Elsevier in Journal of Molecular Biology
- Vol. 437 (12) , 169117
Open AccessAdaptive SELEX Strategies Against HCV Core Protein Lead to the Same Aptamer
- Open Access
- 13 March 2025
- Published by MDPI AG in Preprints.org
Trends and Challenges of SPR Aptasensors in Viral Diagnostics: A Systematic Review and Meta-Analysis
Surface Plasmon Resonance (SPR) aptasensors benefit from the SPR phenomenon in measuring aptamer interactions with specific targets. Integrating aptamers into SPR detection enables extensive applications in clinical analysis. Specifically, virus design aptasensing platforms are highly desirable to face the ongoing challenges of virus outbreaks. This study systematically reviews the latest advances in SPR aptasensors for virus detection according to PRISMA guidelines. The literature search recovered 322 original articles from the Scopus (n = 152), Web of Science (n = 83), and PubMed (n = 87) databases. The selected articles (29) deal with the binding events between the aptamers immobilized on the sensor surface and their target molecule: virus proteins or intact viruses according to different SPR configurations. The methodological quality of each study was assessed using QUADAS-2, and a meta-analysis was conducted with the Cochrane RevMan software. Data were analyzed focusing on the types of viruses, the virus target, and the reference method. The pooled sensitivity was 1.89 (95%, CI 1.29, 2.78, I2 = 49%). The analysis of different types of plasmonic sensors showed the best diagnostic results with the least heterogeneity for SPR conventional configurations: 3.23 (95% CI [1.80, 5.79]; I2 = 0%, p = 0.65). These findings show that even though plasmonic biosensors effectively analyze viruses through aptamer approaches, there are still big challenges to using them regularly for diagnostics. Practical considerations for measuring label-free interactions revealed functional capabilities, technological boundaries, and future outlooks of SPR virus aptasensing.
- 13 March 2025
- Published by MDPI AG in Preprints.org
Open AccessTrends and Challenges of SPR Aptasensors in Viral Diagnostics: A Systematic Review and Meta-Analysis
Surface Plasmon Resonance (SPR) aptasensors benefit from the SPR phenomenon in measuring aptamer interactions with specific targets. Integrating aptamers into SPR detection enables extensive applications in clinical analysis. Specifically, virus design aptasensing platforms are highly desirable to face the ongoing challenges of virus outbreaks. This study systematically reviews the latest advances in SPR aptasensors for virus detection according to PRISMA guidelines. The literature search recovered 322 original articles from the Scopus (n = 152), Web of Science (n = 83), and PubMed (n = 87) databases. The selected articles (29) deal with the binding events between the aptamers immobilized on the sensor surface and their target molecule: virus proteins or intact viruses according to different SPR configurations. The methodological quality of each study was assessed using QUADAS-2, and a meta-analysis was conducted with the Cochrane RevMan software. Data were analyzed focusing on the types of viruses, the virus target, and the reference method. The pooled sensitivity was 1.89 (95%, CI 1.29, 2.78, I2 = 49%). The analysis of different types of plasmonic sensors showed the best diagnostic results with the least heterogeneity for SPR conventional configurations: 3.23 (95% CI [1.80, 5.79]; I2 = 0%, p = 0.65). These findings show that even though plasmonic biosensors effectively analyze viruses through aptamer approaches, there are still big challenges to using them regularly for diagnostics. Practical considerations for measuring label-free interactions revealed functional capabilities, technological boundaries, and future outlooks of SPR virus aptasensing.
- Open Access
- 20 November 2024
- Published by Elsevier in Sensing and Bio-Sensing Research
- Vol. 46
Overcoming challenges in plasmonic biosensors deployment for clinical and biomedical applications: A systematic review and meta-analysis
- 20 November 2024
- Published by Elsevier in Sensing and Bio-Sensing Research
- Vol. 46
Open AccessOvercoming challenges in plasmonic biosensors deployment for clinical and biomedical applications: A systematic review and meta-analysis
- Open Access
- 30 April 2024
- Published by MDPI AG in Microorganisms
- Vol. 12 (5) , 914
Exploring Propolis as a Sustainable Bio-Preservative Agent to Control Foodborne Pathogens in Vacuum-Packed Cooked Ham
The search for natural food additives makes propolis an exciting alternative due to its known antimicrobial activity. This work aims to investigate propolis’ behavior as a nitrite substitute ingredient in cooked ham (a ready-to-eat product) when confronted with pathogenic microorganisms of food interest. The microbial evolution of Listeria monocytogenes, Staphylococcus aureus, Bacillus cereus, and Clostridium sporogenes inoculated at known doses was examined in different batches of cooked ham. The design of a challenge test according to their shelf life (45 days), pH values, and water activity allowed the determination of the mesophilic aerobic flora, psychotropic, and acid lactic bacteria viability. The test was completed with an organoleptic analysis of the samples, considering possible alterations in color and texture. The cooked ham formulation containing propolis instead of nitrites limited the potential growth (δ < 0.5 log10) of all the inoculated microorganisms until day 45, except for L. monocytogenes, which in turn exhibited a bacteriostatic effect between day 7 and 30 of the storage time. The sensory analysis revealed the consumer’s acceptance of cooked ham batches including propolis as a natural additive. These findings suggest the functionality of propolis as a promising alternative to artificial preservatives for ensuring food safety and reducing the proliferation risk of foodborne pathogens in ready-to-eat products.
- 30 April 2024
- Published by MDPI AG in Microorganisms
- Vol. 12 (5) , 914
Open AccessExploring Propolis as a Sustainable Bio-Preservative Agent to Control Foodborne Pathogens in Vacuum-Packed Cooked Ham
The search for natural food additives makes propolis an exciting alternative due to its known antimicrobial activity. This work aims to investigate propolis’ behavior as a nitrite substitute ingredient in cooked ham (a ready-to-eat product) when confronted with pathogenic microorganisms of food interest. The microbial evolution of Listeria monocytogenes, Staphylococcus aureus, Bacillus cereus, and Clostridium sporogenes inoculated at known doses was examined in different batches of cooked ham. The design of a challenge test according to their shelf life (45 days), pH values, and water activity allowed the determination of the mesophilic aerobic flora, psychotropic, and acid lactic bacteria viability. The test was completed with an organoleptic analysis of the samples, considering possible alterations in color and texture. The cooked ham formulation containing propolis instead of nitrites limited the potential growth (δ < 0.5 log10) of all the inoculated microorganisms until day 45, except for L. monocytogenes, which in turn exhibited a bacteriostatic effect between day 7 and 30 of the storage time. The sensory analysis revealed the consumer’s acceptance of cooked ham batches including propolis as a natural additive. These findings suggest the functionality of propolis as a promising alternative to artificial preservatives for ensuring food safety and reducing the proliferation risk of foodborne pathogens in ready-to-eat products.
- Open Access
- 3 February 2024
- Published by Elsevier in Nurse Education in Practice
- Vol. 76, 103911
Exploring eye-tracking data as an indicator of situational awareness in nursing students during a cardiorespiratory arrest simulation
- 3 February 2024
- Published by Elsevier in Nurse Education in Practice
- Vol. 76, 103911
Open AccessExploring eye-tracking data as an indicator of situational awareness in nursing students during a cardiorespiratory arrest simulation