Howard Clyde Wikle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Howard Clyde Wikle has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Bryan A. Chin
10 shared publicationsShin Horikawa
Auburn University
8 shared publicationsDong-Joo Kim
Materials Research and Education Center, Auburn University, Auburn, AL, USA
6 shared publicationsYating Chai
6 shared publicationsB.A. Chin
5 shared publications- Bryan A. Chin
Material Research & Education Center, Auburn University
5 shared publications
Latest Publications
- 25 October 2017
- Published by The Electrochemical Society in ECS Transactions
- Vol. 80 (10) , 1579-1583
Effects of Surface-Scanning Detector Position on the Response of a Wireless Magnetoelastic Biosensor
This paper investigates the measurement accuracy of a wireless magnetoelastic (ME) biosensor for direct pathogen detection on solid surfaces. The experiments were conducted on the surface of a polyethylene (PE) plate as a model study. An ME biosensor (1mm × 0.2 mm × 30 μm) was placed on the PE surface, and a surface-scanning detector was positioned in the proximity of the sensor for wireless resonant frequency measurement. The detector position was accurately controlled by using a motorized three-axis translation system. The results showed that the resonant frequency variations of the sensor were 125 to +150 Hz for X and Y detector displacements of ± 600 μm and Z displacements of +100 to +500 μm. These resonant frequency variations were small compared to the sensor's initial resonant frequency (< 0.007% of 2.2 MHz initial resonant frequency) measured at the detector home position, indicating high accuracy of the measurement.
- 25 October 2017
- Published by The Electrochemical Society in ECS Transactions
- Vol. 80 (10) , 1579-1583
Effects of Surface-Scanning Detector Position on the Response of a Wireless Magnetoelastic Biosensor
This paper investigates the measurement accuracy of a wireless magnetoelastic (ME) biosensor for direct pathogen detection on solid surfaces. The experiments were conducted on the surface of a polyethylene (PE) plate as a model study. An ME biosensor (1mm × 0.2 mm × 30 μm) was placed on the PE surface, and a surface-scanning detector was positioned in the proximity of the sensor for wireless resonant frequency measurement. The detector position was accurately controlled by using a motorized three-axis translation system. The results showed that the resonant frequency variations of the sensor were 125 to +150 Hz for X and Y detector displacements of ± 600 μm and Z displacements of +100 to +500 μm. These resonant frequency variations were small compared to the sensor's initial resonant frequency (< 0.007% of 2.2 MHz initial resonant frequency) measured at the detector home position, indicating high accuracy of the measurement.
- Open Access
Detection of Salmonella Typhimurium on Spinach Using Phage-Based Magnetoelastic Biosensors
Phage-based magnetoelastic (ME) biosensors have been studied as an in-situ, real-time, wireless, direct detection method of foodborne pathogens in recent years. This paper investigates an ME biosensor method for the detection of Salmonella Typhimurium on fresh spinach leaves. A procedure to obtain a concentrated suspension of Salmonella from contaminated spinach leaves is described that is based on methods outlined in the U.S. FDA Bacteriological Analytical Manual for the detection of Salmonella on leafy green vegetables. The effects of an alternative pre-enrichment broth (LB broth vs. lactose broth), incubation time on the detection performance and negative control were investigated. In addition, different blocking agents (BSA, Casein, and Superblock) were evaluated to minimize the effect of nonspecific binding. None of the blocking agents was found to be superior to the others, or even better than none. Unblocked ME biosensors were placed directly in a concentrated suspension and allowed to bind with Salmonella cells for 30 min before measuring the resonant frequency using a surface-scanning coil detector. It was found that 7 h incubation at 37 °C in LB broth was necessary to detect an initial spike of 100 cfu/25 g S. Typhimurium on spinach leaves with a confidence level of difference greater than 95% (p < 0.05). Thus, the ME biosensor method, on both partly and fully detection, was demonstrated to be a robust and competitive method for foodborne pathogens on fresh products.
Open AccessDetection of Salmonella Typhimurium on Spinach Using Phage-Based Magnetoelastic Biosensors
Phage-based magnetoelastic (ME) biosensors have been studied as an in-situ, real-time, wireless, direct detection method of foodborne pathogens in recent years. This paper investigates an ME biosensor method for the detection of Salmonella Typhimurium on fresh spinach leaves. A procedure to obtain a concentrated suspension of Salmonella from contaminated spinach leaves is described that is based on methods outlined in the U.S. FDA Bacteriological Analytical Manual for the detection of Salmonella on leafy green vegetables. The effects of an alternative pre-enrichment broth (LB broth vs. lactose broth), incubation time on the detection performance and negative control were investigated. In addition, different blocking agents (BSA, Casein, and Superblock) were evaluated to minimize the effect of nonspecific binding. None of the blocking agents was found to be superior to the others, or even better than none. Unblocked ME biosensors were placed directly in a concentrated suspension and allowed to bind with Salmonella cells for 30 min before measuring the resonant frequency using a surface-scanning coil detector. It was found that 7 h incubation at 37 °C in LB broth was necessary to detect an initial spike of 100 cfu/25 g S. Typhimurium on spinach leaves with a confidence level of difference greater than 95% (p < 0.05). Thus, the ME biosensor method, on both partly and fully detection, was demonstrated to be a robust and competitive method for foodborne pathogens on fresh products.
- 1 January 2014
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 205, 143-149
A pulsed wave excitation system to characterize micron-scale magnetoelastic biosensors
- 1 January 2014
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 205, 143-149
A pulsed wave excitation system to characterize micron-scale magnetoelastic biosensors
- 1 December 2013
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 50, 311-317
A surface-scanning coil detector for real-time, in-situ detection of bacteria on fresh food surfaces
- 1 December 2013
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 50, 311-317
A surface-scanning coil detector for real-time, in-situ detection of bacteria on fresh food surfaces
- 21 October 2013
- Published by AIP Publishing in Applied Physics Letters
- Vol. 103 (17) , 173510
Surface-scanning coil detectors for magnetoelastic biosensors: A comparison of planar-spiral and solenoid coils
This research introduces a planar spiral coil as a surface-scanning detector for magnetoelastic biosensors, which have been used to detect bacteria directly on food surfaces. The planar coil was compared with the previously investigated solenoid coil, in terms of the magnetic flux change, signal amplitude, and detection distance. Both theoretical calculations and experimental results demonstrated that the planar coil detector yields a dramatically improved signal amplitude and greater detection distance. In addition, simultaneous measurement of multiple biosensors on surfaces was demonstrated. This planar coil is therefore anticipated to facilitate the detection of bacteria on surfaces using magnetoelastic biosensors.
- 21 October 2013
- Published by AIP Publishing in Applied Physics Letters
- Vol. 103 (17) , 173510
Surface-scanning coil detectors for magnetoelastic biosensors: A comparison of planar-spiral and solenoid coils
This research introduces a planar spiral coil as a surface-scanning detector for magnetoelastic biosensors, which have been used to detect bacteria directly on food surfaces. The planar coil was compared with the previously investigated solenoid coil, in terms of the magnetic flux change, signal amplitude, and detection distance. Both theoretical calculations and experimental results demonstrated that the planar coil detector yields a dramatically improved signal amplitude and greater detection distance. In addition, simultaneous measurement of multiple biosensors on surfaces was demonstrated. This planar coil is therefore anticipated to facilitate the detection of bacteria on surfaces using magnetoelastic biosensors.
- 11 September 2013
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 114 (10) , 104504
Design of a surface-scanning coil detector for direct bacteria detection on food surfaces using a magnetoelastic biosensor
The real-time, in-situ bacteria detection on food surfaces was achieved by using a magnetoelastic biosensor combined with a surface-scanning coil detector. This paper focuses on the coil design for signal optimization. The coil was used to excite the sensor's vibration and detect its resonant frequency signal. The vibrating sensor creates a magnetic flux change around the coil, which then produces a mutual inductance. In order to enhance the signal amplitude, a theory of the sensor's mutual inductance with the measurement coil is proposed. Both theoretical calculations and experimental data showed that the working length of the coil has a significant effect on the signal amplitude. For a 1 mm-long sensor, a coil with a working length of 1.3 mm showed the best signal amplitude. The real-time detection of Salmonella bacteria on a fresh food surface was demonstrated using this new technology.
- 11 September 2013
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 114 (10) , 104504
Design of a surface-scanning coil detector for direct bacteria detection on food surfaces using a magnetoelastic biosensor
The real-time, in-situ bacteria detection on food surfaces was achieved by using a magnetoelastic biosensor combined with a surface-scanning coil detector. This paper focuses on the coil design for signal optimization. The coil was used to excite the sensor's vibration and detect its resonant frequency signal. The vibrating sensor creates a magnetic flux change around the coil, which then produces a mutual inductance. In order to enhance the signal amplitude, a theory of the sensor's mutual inductance with the measurement coil is proposed. Both theoretical calculations and experimental data showed that the working length of the coil has a significant effect on the signal amplitude. For a 1 mm-long sensor, a coil with a working length of 1.3 mm showed the best signal amplitude. The real-time detection of Salmonella bacteria on a fresh food surface was demonstrated using this new technology.
- 29 May 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8721, 87210B
A new wireless detection device for thein-situidentification ofSalmonellaTyphimurium
This paper presents a new device and method for the in-situ detection of Salmonella Typhimurium on tomato surfaces. This real-time in-situ detection was accomplished with phage-based magnetoelastic (ME) biosensors on fresh food surfaces. The E2 phage from a landscape phage library serves as the bio-recognition element that has the capability of binding specifically with S. Typhimurium. This mass-sensitive ME biosensor is wirelessly actuated into mechanical resonance by an externally applied time-varying magnetic field. When the biosensor binds with S. Typhimurium, the mass of the sensor increases, resulting in a decrease in the sensor's resonant frequency. Until now, ME sensors had to be collected from the tomato surface where they are exposed to S. Typhimurium and inserted into a measurement coil for the detection of the bacterium. In contrast, the newly designed test device allows the whole detection process to take place directly on the tomato. Changes in resonant frequency over time due to the accumulation of S. Typhimurium on the sensor were measured and are presented. Real-time in-situ detection of 20 minutes was achieved. In addition, this new methodology effectively decreases the measurement error and enables the simultaneous detection of multiple pathogens.
- 29 May 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8721, 87210B
A new wireless detection device for thein-situidentification ofSalmonellaTyphimurium
This paper presents a new device and method for the in-situ detection of Salmonella Typhimurium on tomato surfaces. This real-time in-situ detection was accomplished with phage-based magnetoelastic (ME) biosensors on fresh food surfaces. The E2 phage from a landscape phage library serves as the bio-recognition element that has the capability of binding specifically with S. Typhimurium. This mass-sensitive ME biosensor is wirelessly actuated into mechanical resonance by an externally applied time-varying magnetic field. When the biosensor binds with S. Typhimurium, the mass of the sensor increases, resulting in a decrease in the sensor's resonant frequency. Until now, ME sensors had to be collected from the tomato surface where they are exposed to S. Typhimurium and inserted into a measurement coil for the detection of the bacterium. In contrast, the newly designed test device allows the whole detection process to take place directly on the tomato. Changes in resonant frequency over time due to the accumulation of S. Typhimurium on the sensor were measured and are presented. Real-time in-situ detection of 20 minutes was achieved. In addition, this new methodology effectively decreases the measurement error and enables the simultaneous detection of multiple pathogens.
- 15 March 2013
- Published by The Electrochemical Society in ECS Transactions
- Vol. 50 (12) , 53-59
Bio-Inspired Autonomous Sentinel System for Screening Invasive Pathogens
This paper presents the results of a preliminary investigation to develop a bio-inspired autonomous pathogen screening system that mimics the function of natural immune systems, such as white blood cells. This screening system is comprised of multiple magnetoelastic (ME) biosentinels. The sentinels are composed of a wireless magnetoelastic resonator immobilized with a bio-probe layer that captures specific target pathogens. The biosentinels are actuated, monitored, and controlled wirelessly by external magnetic fields. The autonomous sentinel system is envisioned to have the capability of seeking out invasive pathogens in liquid environments, detecting and capturing them. In the paper, the proof-in-principal of the concept of autonomous sentinels is demonstrated by comparing the response of the sentinels in dynamic and static Salmonella analytes.
- 15 March 2013
- Published by The Electrochemical Society in ECS Transactions
- Vol. 50 (12) , 53-59
Bio-Inspired Autonomous Sentinel System for Screening Invasive Pathogens
This paper presents the results of a preliminary investigation to develop a bio-inspired autonomous pathogen screening system that mimics the function of natural immune systems, such as white blood cells. This screening system is comprised of multiple magnetoelastic (ME) biosentinels. The sentinels are composed of a wireless magnetoelastic resonator immobilized with a bio-probe layer that captures specific target pathogens. The biosentinels are actuated, monitored, and controlled wirelessly by external magnetic fields. The autonomous sentinel system is envisioned to have the capability of seeking out invasive pathogens in liquid environments, detecting and capturing them. In the paper, the proof-in-principal of the concept of autonomous sentinels is demonstrated by comparing the response of the sentinels in dynamic and static Salmonella analytes.
- 1 January 2013
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 176, 1134-1140
Evaluation of phage-based magnetoelastic biosensors for direct detection of Salmonella Typhimurium on spinach leaves
- 1 January 2013
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 176, 1134-1140
Evaluation of phage-based magnetoelastic biosensors for direct detection of Salmonella Typhimurium on spinach leaves
- 1 January 2013
- Published by Springer Nature in Communications in Computer and Information Science
- p. 68-79
Pathogen Detection Using Magnetoelastic Biosentinels
- 1 January 2013
- Published by Springer Nature in Communications in Computer and Information Science
- p. 68-79
Pathogen Detection Using Magnetoelastic Biosentinels