Marco Esposito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Marco Esposito has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Nassir Navab
Chair for Computer Aided Medical Procedures, Technische Universität München, Germany
11 shared publicationsBenjamin Frisch
Computer Aided Medical Procedures, Technische Universität München, Boltzmannstr. 3, 85748, Garching, Germany
8 shared publicationsBenjamin Busam
4 shared publicationsChristoph Hennersperger
Computer Aided Medical Procedures, Technische Universität München, Boltzmannstr. 3, 85748, Garching, Germany
3 shared publicationsJulia Rackerseder
Computer Aided Medical Procedures (CAMP), Technische Universität München, Munich, Germany
3 shared publicationsBenoit Diotte
Technische Univ. München
2 shared publications
Latest Publications
- Top Cited Papers
- 14 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (7) , 7064-7075
Autonomous Robotic Screening of Tubular Structures Based Only on Real-Time Ultrasound Imaging Feedback
Ultrasound (US) imaging is widely employed for diagnosis and staging of vascular diseases, mainly due to its high availability and the fact it does not emit ionizing radiation. However, high interoperator variability limits the repeatability of US image acquisition. To address this challenge, we propose an end-to-end workflow for automatic robotic US screening of tubular structures using only real-time US imaging feedback. First, a U-Net was trained for real-time segmentation of vascular structure from cross-sectional US images. Then, we represented the detected vascular structure as a 3-D point cloud, which was used to estimate the centerline of the target structure and its local radius by solving a constrained nonlinear optimization problem. Iterating the previous processes, the US probe was automatically aligned to the normal direction of the target structure, while the object was constantly maintained in the center of the US view. The real-time segmentation result was evaluated both on a phantom and in vivo on brachial arteries of volunteers. In addition, the whole process was validated using both simulation and physical phantoms. The mean absolute orientation, centering, and radius error ($\pm$ SD) on a gel phantom were$\text{3.7}\pm \text{1.6}^{\circ }$ ,$0.2\pm \text{0.2}\,\text{mm}$ and$0.8\pm \text{0.4}\,\text{mm}$ , respectively. The results indicate that the method can automatically screen tubular structures with an optimal probe orientation (i.e., normal to the vessel) and accurately estimate the radius of the target structure.- 14 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (7) , 7064-7075
Top Cited PapersAutonomous Robotic Screening of Tubular Structures Based Only on Real-Time Ultrasound Imaging Feedback
Ultrasound (US) imaging is widely employed for diagnosis and staging of vascular diseases, mainly due to its high availability and the fact it does not emit ionizing radiation. However, high interoperator variability limits the repeatability of US image acquisition. To address this challenge, we propose an end-to-end workflow for automatic robotic US screening of tubular structures using only real-time US imaging feedback. First, a U-Net was trained for real-time segmentation of vascular structure from cross-sectional US images. Then, we represented the detected vascular structure as a 3-D point cloud, which was used to estimate the centerline of the target structure and its local radius by solving a constrained nonlinear optimization problem. Iterating the previous processes, the US probe was automatically aligned to the normal direction of the target structure, while the object was constantly maintained in the center of the US view. The real-time segmentation result was evaluated both on a phantom and in vivo on brachial arteries of volunteers. In addition, the whole process was validated using both simulation and physical phantoms. The mean absolute orientation, centering, and radius error ($\pm$ SD) on a gel phantom were$\text{3.7}\pm \text{1.6}^{\circ }$ ,$0.2\pm \text{0.2}\,\text{mm}$ and$0.8\pm \text{0.4}\,\text{mm}$ , respectively. The results indicate that the method can automatically screen tubular structures with an optimal probe orientation (i.e., normal to the vessel) and accurately estimate the radius of the target structure. - 11 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (10) , 2245-2258
Total Variation Regularization of Pose Signals With an Application to 3D Freehand Ultrasound
Three-dimensional freehand imaging techniques are gaining wider adoption due to their ?exibility and cost ef?ciency. Typical examples for such a combination of a tracking system with an imaging device are freehand SPECT or freehand 3D ultrasound. However, the quality of the resulting image data is heavily dependent on the skill of the human operator and on the level of noise of the tracking data. The latter aspect can introduce blur or strong artifacts, which can signi?cantly hamper the interpretation of image data. Unfortunately, the most commonly used tracking systems to date, i.e. optical and electromagnetic, present a trade-off between invading the surgeon’s workspace (due to line-of-sight requirements) and higher levels of noise and sensitivity due to the interference of surrounding metallic objects. In this work, we propose a novel approach for total variation regularization of data from tracking systems (which we term pose signals) based on a variational formulation in the manifold of Euclidean transformations. The performance of the proposed approach was evaluated using synthetic data as well as real ultrasound sweeps executed on both a Lego phantom and human anatomy, showing signi?cant improvement in terms of tracking data quality and compounded ultrasound images. Source code can be found at https://github.com/IFL-CAMP/pose_regularization.
- 11 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (10) , 2245-2258
Total Variation Regularization of Pose Signals With an Application to 3D Freehand Ultrasound
Three-dimensional freehand imaging techniques are gaining wider adoption due to their ?exibility and cost ef?ciency. Typical examples for such a combination of a tracking system with an imaging device are freehand SPECT or freehand 3D ultrasound. However, the quality of the resulting image data is heavily dependent on the skill of the human operator and on the level of noise of the tracking data. The latter aspect can introduce blur or strong artifacts, which can signi?cantly hamper the interpretation of image data. Unfortunately, the most commonly used tracking systems to date, i.e. optical and electromagnetic, present a trade-off between invading the surgeon’s workspace (due to line-of-sight requirements) and higher levels of noise and sensitivity due to the interference of surrounding metallic objects. In this work, we propose a novel approach for total variation regularization of data from tracking systems (which we term pose signals) based on a variational formulation in the manifold of Euclidean transformations. The performance of the proposed approach was evaluated using synthetic data as well as real ultrasound sweeps executed on both a Lego phantom and human anatomy, showing signi?cant improvement in terms of tracking data quality and compounded ultrasound images. Source code can be found at https://github.com/IFL-CAMP/pose_regularization.
- 13 September 2018
- Published by Springer Nature
- p. 667-674
CFCM: Segmentation via Coarse to Fine Context Memory
- 13 September 2018
- Published by Springer Nature
- p. 667-674
CFCM: Segmentation via Coarse to Fine Context Memory
- 24 February 2017
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 12 (9) , 1607-1619
3D ultrasound registration-based visual servoing for neurosurgical navigation
Purpose We present a fully image-based visual servoing framework for neurosurgical navigation and needle guidance. The proposed servo-control scheme allows for compensation of target anatomy movements, maintaining high navigational accuracy over time, and automatic needle guide alignment for accurate manual insertions. Method Our system comprises a motorized 3D ultrasound (US) transducer mounted on a robotic arm and equipped with a needle guide. It continuously registers US sweeps in real time with a pre-interventional plan based on CT or MR images and annotations. While a visual control law maintains anatomy visibility and alignment of the needle guide, a force controller is employed for acoustic coupling and tissue pressure. We validate the servoing capabilities of our method on a geometric gel phantom and real human anatomy, and the needle targeting accuracy using CT images on a lumbar spine gel phantom under neurosurgery conditions. Results Despite the varying resolution of the acquired 3D sweeps, we achieved direction-independent positioning errors of \(0.35\pm 0.19\) mm and \(0.61^\circ \pm 0.45^\circ \), respectively. Our method is capable of compensating movements of around 25 mm/s and works reliably on human anatomy with errors of \(1.45\pm 0.78\) mm. In all four manual insertions by an expert surgeon, a needle could be successfully inserted into the facet joint, with an estimated targeting accuracy of \(1.33\pm 0.33\) mm, superior to the gold standard. Conclusion The experiments demonstrated the feasibility of robotic ultrasound-based navigation and needle guidance for neurosurgical applications such as lumbar spine injections.- 24 February 2017
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 12 (9) , 1607-1619
3D ultrasound registration-based visual servoing for neurosurgical navigation
Purpose We present a fully image-based visual servoing framework for neurosurgical navigation and needle guidance. The proposed servo-control scheme allows for compensation of target anatomy movements, maintaining high navigational accuracy over time, and automatic needle guide alignment for accurate manual insertions. Method Our system comprises a motorized 3D ultrasound (US) transducer mounted on a robotic arm and equipped with a needle guide. It continuously registers US sweeps in real time with a pre-interventional plan based on CT or MR images and annotations. While a visual control law maintains anatomy visibility and alignment of the needle guide, a force controller is employed for acoustic coupling and tissue pressure. We validate the servoing capabilities of our method on a geometric gel phantom and real human anatomy, and the needle targeting accuracy using CT images on a lumbar spine gel phantom under neurosurgery conditions. Results Despite the varying resolution of the acquired 3D sweeps, we achieved direction-independent positioning errors of \(0.35\pm 0.19\) mm and \(0.61^\circ \pm 0.45^\circ \), respectively. Our method is capable of compensating movements of around 25 mm/s and works reliably on human anatomy with errors of \(1.45\pm 0.78\) mm. In all four manual insertions by an expert surgeon, a needle could be successfully inserted into the facet joint, with an estimated targeting accuracy of \(1.33\pm 0.33\) mm, superior to the gold standard. Conclusion The experiments demonstrated the feasibility of robotic ultrasound-based navigation and needle guidance for neurosurgical applications such as lumbar spine injections.- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 508-513
Automatic force-compliant robotic ultrasound screening of abdominal aortic aneurysms
Ultrasound (US) imaging is commonly employed for the diagnosis and staging of abdominal aortic aneurysms (AAA), mainly due to its non-invasiveness and high availability. High inter-operator variability and a lack of repeatability of current US image acquisition impair the implementation of extensive screening programs for affected patient populations. However, this opens the way to a possible automation of the procedure, and recent works have exploited the use of robotic platforms for US applications, both in diagnostic and interventional scenarios. In this work, we propose a system for autonomous robotic US acquisitions aimed at the quantitative assessment of patients' vessel diameter for abdominal aortic aneurysm screening. Using a probabilistic measure of the US quality, we introduce an automatic estimation of the optimal pressure to be applied during the acquisition, and an online optimization of the out-of-plane rotation of the US probe to maximize the visibility of the aorta. We evaluate our method on healthy volunteers and compare the results to manual acquisitions performed by a clinical expert, demonstrating the feasibility of the presented system for AAA screening.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 508-513
Automatic force-compliant robotic ultrasound screening of abdominal aortic aneurysms
Ultrasound (US) imaging is commonly employed for the diagnosis and staging of abdominal aortic aneurysms (AAA), mainly due to its non-invasiveness and high availability. High inter-operator variability and a lack of repeatability of current US image acquisition impair the implementation of extensive screening programs for affected patient populations. However, this opens the way to a possible automation of the procedure, and recent works have exploited the use of robotic platforms for US applications, both in diagnostic and interventional scenarios. In this work, we propose a system for autonomous robotic US acquisitions aimed at the quantitative assessment of patients' vessel diameter for abdominal aortic aneurysm screening. Using a probabilistic measure of the US quality, we introduce an automatic estimation of the optimal pressure to be applied during the acquisition, and an online optimization of the out-of-plane rotation of the US probe to maximize the visibility of the aorta. We evaluate our method on healthy volunteers and compare the results to manual acquisitions performed by a clinical expert, demonstrating the feasibility of the presented system for AAA screening.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 629-638
Quaternionic Upsampling: Hyperspherical Techniques for 6 DoF Pose Tracking
Fast real-time tracking is an integral component of modern 3D computer vision pipelines. Despite their advantages in accuracy and reliability, optical trackers suffer from limited acquisition rates depending either on intrinsic sensor capabilities or physical limitations such as exposure time. Moreover, data transmission and image processing produce latency in the pose stream. We introduce quaternionic upsampling to overcome these problems. The technique models the pose parameters as points on multidimensional hyperspheres in (dual) quaternion space. In order to upsample the pose stream, we present several methods to sample points on geodesics and piecewise continuous curves on these manifolds and compare them regarding accuracy and computation efficiency. With the unified approach of quaternionic upsampling, both interpolation and extrapolation in pose space can be done by continuous linear variation of only one sampling parameter. Since the method can be implemented rather efficiently, pose rates of over 4 kHz and future pose predictions with an accuracy of 128 μm and 0.5° are possible in real-time. The method does not depend on a special tracking algorithm and can thus be used for any arbitrary 3 DoF or 6 DoF rotation or pose tracking system.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 629-638
Quaternionic Upsampling: Hyperspherical Techniques for 6 DoF Pose Tracking
Fast real-time tracking is an integral component of modern 3D computer vision pipelines. Despite their advantages in accuracy and reliability, optical trackers suffer from limited acquisition rates depending either on intrinsic sensor capabilities or physical limitations such as exposure time. Moreover, data transmission and image processing produce latency in the pose stream. We introduce quaternionic upsampling to overcome these problems. The technique models the pose parameters as points on multidimensional hyperspheres in (dual) quaternion space. In order to upsample the pose stream, we present several methods to sample points on geodesics and piecewise continuous curves on these manifolds and compare them regarding accuracy and computation efficiency. With the unified approach of quaternionic upsampling, both interpolation and extrapolation in pose space can be done by continuous linear variation of only one sampling parameter. Since the method can be implemented rather efficiently, pose rates of over 4 kHz and future pose predictions with an accuracy of 128 μm and 0.5° are possible in real-time. The method does not depend on a special tracking algorithm and can thus be used for any arbitrary 3 DoF or 6 DoF rotation or pose tracking system.
- 9 August 2016
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (9) , 1561-1571
Multimodal US–gamma imaging using collaborative robotics for cancer staging biopsies
The staging of female breast cancer requires detailed information about the level of cancer spread through the lymphatic system. Common practice to obtain this information for patients with early-stage cancer is sentinel lymph node (SLN) biopsy, where LNs are radioactively identified for surgical removal and subsequent histological analysis. Punch needle biopsy is a less invasive approach but suffers from the lack of combined anatomical and nuclear information. We present and evaluate a system that introduces live collaborative robotic 2D gamma imaging in addition to live 2D ultrasound to identify SLNs in the surrounding anatomy. The system consists of a robotic arm equipped with both a gamma camera and a stereoscopic tracking system that monitors the position of an ultrasound probe operated by the physician. The arm cooperatively places the gamma camera parallel to the ultrasound imaging plane to provide live multimodal visualization and guidance. We validate the system by evaluating the target registration errors between fused nuclear and US image data in a phantom consisting of two spheres, one of which is filled with radioactivity. Medical experts perform punch biopsies on agar–gelatine phantoms with complex configurations of hot and cold lesions to provide a qualitative and quantitative evaluation of the system. The average point registration error for the overlay is \(1.12 \pm 0.57\) mm. The time of the entire procedure was reduced by 36 %, with 80v of the biopsies being successful. The users’ feedback was very positive, and the system was deemed to be very intuitive, with handling similar to classic US-guided needle biopsy. We present and evaluate the first medical collaborative robotic imaging system. Feedback from potential users for SLN punch needle biopsy is encouraging. Ongoing work investigates the clinical feasibility with more complex and realistic phantoms.- 9 August 2016
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (9) , 1561-1571
Multimodal US–gamma imaging using collaborative robotics for cancer staging biopsies
The staging of female breast cancer requires detailed information about the level of cancer spread through the lymphatic system. Common practice to obtain this information for patients with early-stage cancer is sentinel lymph node (SLN) biopsy, where LNs are radioactively identified for surgical removal and subsequent histological analysis. Punch needle biopsy is a less invasive approach but suffers from the lack of combined anatomical and nuclear information. We present and evaluate a system that introduces live collaborative robotic 2D gamma imaging in addition to live 2D ultrasound to identify SLNs in the surrounding anatomy. The system consists of a robotic arm equipped with both a gamma camera and a stereoscopic tracking system that monitors the position of an ultrasound probe operated by the physician. The arm cooperatively places the gamma camera parallel to the ultrasound imaging plane to provide live multimodal visualization and guidance. We validate the system by evaluating the target registration errors between fused nuclear and US image data in a phantom consisting of two spheres, one of which is filled with radioactivity. Medical experts perform punch biopsies on agar–gelatine phantoms with complex configurations of hot and cold lesions to provide a qualitative and quantitative evaluation of the system. The average point registration error for the overlay is \(1.12 \pm 0.57\) mm. The time of the entire procedure was reduced by 36 %, with 80v of the biopsies being successful. The users’ feedback was very positive, and the system was deemed to be very intuitive, with handling similar to classic US-guided needle biopsy. We present and evaluate the first medical collaborative robotic imaging system. Feedback from potential users for SLN punch needle biopsy is encouraging. Ongoing work investigates the clinical feasibility with more complex and realistic phantoms.- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 945-950
Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation
While intraoperative imaging is commonly used to guide surgical interventions, automatic robotic support for image-guided navigation has not yet been established in clinical routine. In this paper, we propose a novel visual servoing framework that combines, for the first time, full image-based 3D ultrasound registration with a real-time servo-control scheme. Paired with multi-modal fusion to a pre-interventional plan such as an annotated needle insertion path, it thus allows tracking a target anatomy, continuously updating the plan as the target moves, and keeping a needle guide aligned for accurate manual insertion. The presented system includes a motorized 3D ultrasound transducer mounted on a force-controlled robot and a GPU-based image processing toolkit. The tracking accuracy of our framework is validated on a geometric agar/gelatin phantom using a second robot, achieving positioning errors of on average 0.42-0.44 mm. With compounding and registration runtimes of up to total around 550 ms, real-time performance comes into reach. We also present initial results on a spine phantom, demonstrating the feasibility of our system for lumbar spine injections.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 945-950
Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation
While intraoperative imaging is commonly used to guide surgical interventions, automatic robotic support for image-guided navigation has not yet been established in clinical routine. In this paper, we propose a novel visual servoing framework that combines, for the first time, full image-based 3D ultrasound registration with a real-time servo-control scheme. Paired with multi-modal fusion to a pre-interventional plan such as an annotated needle insertion path, it thus allows tracking a target anatomy, continuously updating the plan as the target moves, and keeping a needle guide aligned for accurate manual insertion. The presented system includes a motorized 3D ultrasound transducer mounted on a force-controlled robot and a GPU-based image processing toolkit. The tracking accuracy of our framework is validated on a geometric agar/gelatin phantom using a second robot, achieving positioning errors of on average 0.42-0.44 mm. With compounding and registration runtimes of up to total around 550 ms, real-time performance comes into reach. We also present initial results on a spine phantom, demonstrating the feasibility of our system for lumbar spine injections.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 519-527
A Stereo Vision Approach for Cooperative Robotic Movement Therapy
Movement therapy is an integrating part of stroke rehabilitation. The positive influence of intensive, repetitive motion training and the importance of active patient participation trigger the development of cooperative robotic assistants. We suggest a device for the re-education of upper limb movements in hemiparetic patients where a light-weight robotic arm that supports the deficient arm is equipped with a stereoscopic camera system. It follows the movements of the healthy arm that wears a sleeve equipped with flat round reflective markers detected by the cameras. We introduce an advanced robust and real-time algorithm to provide the tracking information. It performs a sparse marker based point cloud registration based on subpixel precision contour fits to enable high accuracy pose estimates while being capable of online model adjustments. The update rate of the tracking is 9 ms and the precision of the system is measured to be 0.5 mm. Tests with healthy subjects show that the system is able to accurately reproduce the movement of the healthy arm on an impaired arm.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 519-527
A Stereo Vision Approach for Cooperative Robotic Movement Therapy
Movement therapy is an integrating part of stroke rehabilitation. The positive influence of intensive, repetitive motion training and the importance of active patient participation trigger the development of cooperative robotic assistants. We suggest a device for the re-education of upper limb movements in hemiparetic patients where a light-weight robotic arm that supports the deficient arm is equipped with a stereoscopic camera system. It follows the movements of the healthy arm that wears a sleeve equipped with flat round reflective markers detected by the cameras. We introduce an advanced robust and real-time algorithm to provide the tracking information. It performs a sparse marker based point cloud registration based on subpixel precision contour fits to enable high accuracy pose estimates while being capable of online model adjustments. The update rate of the tracking is 9 ms and the precision of the system is measured to be 0.5 mm. Tests with healthy subjects show that the system is able to accurately reproduce the movement of the healthy arm on an impaired arm.
- 20 November 2015
- Published by Springer Nature
- p. 611-618
Cooperative Robotic Gamma Imaging: Enhancing US-guided Needle Biopsy
- 20 November 2015
- Published by Springer Nature
- p. 611-618
Cooperative Robotic Gamma Imaging: Enhancing US-guided Needle Biopsy