Hao Jan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hao Jan Liu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Hao Zhu
Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, USA
6 shared publications Wei Shi
Department of Electrical & Computer Engineering, Boston University, 8 Saint Mary’s Street, Boston, MA 02215, USA
2 shared publications- Chia-Chi Chu
National Tsing Hua University
1 shared publication - Kyeon Hur
School of Electrical and Electronic Engineering, Yonsei University, Seoul, South Korea
1 shared publication - Kyungsung An
School of Electrical and Electronic Engineering, Yonsei University, Seoul 120-149, Korea
1 shared publication - Lin-Yu Lu1 shared publication
Latest Publications
- 21 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 10 (6) , 6502-6515
Intrusion Detection in Distributed Frequency Control of Isolated Microgrids
- 21 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 10 (6) , 6502-6515
Intrusion Detection in Distributed Frequency Control of Isolated Microgrids
- 24 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 10 (3) , 2416-2427
Hybrid Voltage Control in Distribution Networks Under Limited Communication Rates
Voltage regulation in distribution networks is challenged by increasing penetration of distributed energy resources (DERs). Thanks to advancement in power electronics, DERs can be leveraged to regulate the grid voltage by quickly changing their reactive power outputs. This paper develops a hybrid voltage control (HVC) strategy that can seamlessly integrate both local and distributed designs to effectively coordinate the network-wide DERs. By minimizing a special voltage mismatch objective, we achieve the proposed HVC design by adopting partial primal-dual (PPD) gradient updates that can allow for a distributed and online implementation. The proposed HVC design improves over existing distributed approaches by reliably integrating local voltage feedback. As a result, it can dynamically adapt to varying system operating conditions while being fully cognizant of the instantaneous availability of communication links. Under the worst-case scenario of total link outages, the proposed design naturally boils down to a surrogate local control implementation. Numerical tests on realistic feeder cases have been made to corroborate our analytical results and demonstrate the algorithmic performance.
- 24 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 10 (3) , 2416-2427
Hybrid Voltage Control in Distribution Networks Under Limited Communication Rates
Voltage regulation in distribution networks is challenged by increasing penetration of distributed energy resources (DERs). Thanks to advancement in power electronics, DERs can be leveraged to regulate the grid voltage by quickly changing their reactive power outputs. This paper develops a hybrid voltage control (HVC) strategy that can seamlessly integrate both local and distributed designs to effectively coordinate the network-wide DERs. By minimizing a special voltage mismatch objective, we achieve the proposed HVC design by adopting partial primal-dual (PPD) gradient updates that can allow for a distributed and online implementation. The proposed HVC design improves over existing distributed approaches by reliably integrating local voltage feedback. As a result, it can dynamically adapt to varying system operating conditions while being fully cognizant of the instantaneous availability of communication links. Under the worst-case scenario of total link outages, the proposed design naturally boils down to a surrogate local control implementation. Numerical tests on realistic feeder cases have been made to corroborate our analytical results and demonstrate the algorithmic performance.
- 11 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (6) , 6106-6117
Distributed Voltage Control in Distribution Networks: Online and Robust Implementations
Voltage regulation in distribution networks is increasingly challenged by the penetration of distributed energy resources (DERs). This paper develops a distributed voltage control (DVC) scheme to achieve the globally optimal settings of reactive power provided by DERs' power electronic interfaces. Based on unbalanced network flow modeling, the alternating direction method of multipliers algorithm is used to develop the proposed distributed design. To simplify the communication network, the power flow coupling is linearized to involve only neighboring buses. Interestingly, this linear approximation model enjoys a satisfactory performance and allows to exchange information only between neighboring buses. The DVC design is further improved for online implementations that can efficiently adapt to time-varying operating conditions. Last, to cope with cyber resource constraints, we slightly change the DVC design using a “freezing strategy” for unavailable variables due to link failures with guaranteed convergence. Numerical simulations using realistic multi-phase feeders and daily generation/load time-series have validated our analytical results and demonstrated the performance improved by the proposed DVC designs.
- 11 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (6) , 6106-6117
Distributed Voltage Control in Distribution Networks: Online and Robust Implementations
Voltage regulation in distribution networks is increasingly challenged by the penetration of distributed energy resources (DERs). This paper develops a distributed voltage control (DVC) scheme to achieve the globally optimal settings of reactive power provided by DERs' power electronic interfaces. Based on unbalanced network flow modeling, the alternating direction method of multipliers algorithm is used to develop the proposed distributed design. To simplify the communication network, the power flow coupling is linearized to involve only neighboring buses. Interestingly, this linear approximation model enjoys a satisfactory performance and allows to exchange information only between neighboring buses. The DVC design is further improved for online implementations that can efficiently adapt to time-varying operating conditions. Last, to cope with cyber resource constraints, we slightly change the DVC design using a “freezing strategy” for unavailable variables due to link failures with guaranteed convergence. Numerical simulations using realistic multi-phase feeders and daily generation/load time-series have validated our analytical results and demonstrated the performance improved by the proposed DVC designs.
- Open Access
Evaluation of Conservation Voltage Reduction with Analytic Hierarchy Process: A Decision Support Framework in Grid Operations Planning
This paper presents a systematic framework to evaluate the performance of conservation voltage reduction (CVR) by determining suitable substations for CVR in operations planning. Existing CVR planning practice generally only focuses on the energy saving aspect without taking other underlying attributes into account, i.e., network topology and reduced voltage effects on other substations. To secure the desired operating reserve and avoid any adverse impacts, these attributes should be considered for implementing CVR more effectively. This research develops a practical decision-making framework based on the analytic hierarchy process (AHP) to quantify several of the aforementioned attributes. Candidate substations for CVR deployment are prioritized such that performances are compared in terms of power transfer distribution factor (PTDF), voltage sensitivity factor (VSF), and CVR factor. In addition, to meet a specified reserve requirement, an integer programming approach is adopted to select potential substations for CVR implementations. Case studies for a Korean electric power system under diverse operating conditions are performed to demonstrate the effectiveness of the proposed method.
Open AccessEvaluation of Conservation Voltage Reduction with Analytic Hierarchy Process: A Decision Support Framework in Grid Operations Planning
This paper presents a systematic framework to evaluate the performance of conservation voltage reduction (CVR) by determining suitable substations for CVR in operations planning. Existing CVR planning practice generally only focuses on the energy saving aspect without taking other underlying attributes into account, i.e., network topology and reduced voltage effects on other substations. To secure the desired operating reserve and avoid any adverse impacts, these attributes should be considered for implementing CVR more effectively. This research develops a practical decision-making framework based on the analytic hierarchy process (AHP) to quantify several of the aforementioned attributes. Candidate substations for CVR deployment are prioritized such that performances are compared in terms of power transfer distribution factor (PTDF), voltage sensitivity factor (VSF), and CVR factor. In addition, to meet a specified reserve requirement, an integer programming approach is adopted to select potential substations for CVR implementations. Case studies for a Korean electric power system under diverse operating conditions are performed to demonstrate the effectiveness of the proposed method.
- Open Access
Decentralized Dynamic Optimization for Power Network Voltage Control
Voltage control in power distribution networks has been greatly challenged by the increasing penetration of volatile and intermittent devices. These devices can also provide limited reactive power resources that can be used to regulate the network-wide voltage. A decentralized voltage control strategy can be designed by minimizing a quadratic voltage mismatch error objective using gradient-projection (GP) updates. Coupled with the power network flow, the local voltage can provide the instantaneous gradient information. This paper aims to analyze the performance of this decentralized GP-based voltage control design under two dynamic scenarios: i) the nodes perform the decentralized update in an asynchronous fashion, and ii) the network operating condition is time-varying. For the asynchronous voltage control, we improve the existing convergence condition by recognizing that the voltage based gradient is always up-to-date. By modeling the network dynamics using an autoregressive process and considering time-varying resource constraints, we provide an error bound in tracking the instantaneous optimal solution to the quadratic error objective. This result can be extended to more general \textit{constrained dynamic optimization} problems with smooth strongly convex objective functions under stochastic processes that have bounded iterative changes. Extensive numerical tests have been performed to demonstrate and validate our analytical results for realistic power networks.
Open AccessDecentralized Dynamic Optimization for Power Network Voltage Control
Voltage control in power distribution networks has been greatly challenged by the increasing penetration of volatile and intermittent devices. These devices can also provide limited reactive power resources that can be used to regulate the network-wide voltage. A decentralized voltage control strategy can be designed by minimizing a quadratic voltage mismatch error objective using gradient-projection (GP) updates. Coupled with the power network flow, the local voltage can provide the instantaneous gradient information. This paper aims to analyze the performance of this decentralized GP-based voltage control design under two dynamic scenarios: i) the nodes perform the decentralized update in an asynchronous fashion, and ii) the network operating condition is time-varying. For the asynchronous voltage control, we improve the existing convergence condition by recognizing that the voltage based gradient is always up-to-date. By modeling the network dynamics using an autoregressive process and considering time-varying resource constraints, we provide an error bound in tracking the instantaneous optimal solution to the quadratic error objective. This result can be extended to more general \textit{constrained dynamic optimization} problems with smooth strongly convex objective functions under stochastic processes that have bounded iterative changes. Extensive numerical tests have been performed to demonstrate and validate our analytical results for realistic power networks.
- Open Access
Fast Local Voltage Control under Limited Reactive Power: Optimality and Stability Analysis
High penetration of distributed energy resources presents several challenges and opportunities for voltage regulation in power distribution systems. A local reactive power (VAR) control framework will be developed that can fast respond to voltage mismatch and address the robustness issues of (de-)centralized approaches against communication delays and noises. Using local bus voltage measurements, the proposed gradient-projection based schemes explicitly account for the VAR limit of every bus, and are proven convergent to a surrogate centralized problem with proper parameter choices. This optimality result quantifies the capability of local VAR control without requiring any real-time communications. The proposed framework and analysis generalize earlier results on the droop VAR control design, which may suffer from under-utilization of VAR resources in order to ensure stability. Numerical tests have demonstrated the validity of our analytical results and the effectiveness of proposed approaches implemented on realistic three-phase systems.
Open AccessFast Local Voltage Control under Limited Reactive Power: Optimality and Stability Analysis
High penetration of distributed energy resources presents several challenges and opportunities for voltage regulation in power distribution systems. A local reactive power (VAR) control framework will be developed that can fast respond to voltage mismatch and address the robustness issues of (de-)centralized approaches against communication delays and noises. Using local bus voltage measurements, the proposed gradient-projection based schemes explicitly account for the VAR limit of every bus, and are proven convergent to a surrogate centralized problem with proper parameter choices. This optimality result quantifies the capability of local VAR control without requiring any real-time communications. The proposed framework and analysis generalize earlier results on the droop VAR control design, which may suffer from under-utilization of VAR resources in order to ensure stability. Numerical tests have demonstrated the validity of our analytical results and the effectiveness of proposed approaches implemented on realistic three-phase systems.