Yoshiaki Adachi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yoshiaki Adachi has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Daisuke Oyama
Kanazawa Institute of Technology
18 shared publications Gen Uehara
Applied Electronics Laboratory, Kanazawa Institute of Technology
11 shared publications- Gen Uehara
Applied Electronics Laboratory, Kanazawa Institute of Technology, Kanazawa, Japan
11 shared publications - Jun Kawai
Kanazawa Institute of Technology, 3 Amaike, Kanazawa, 9201331, Japan [JP
9 shared publications Shigenori Kawabata
Department of Advanced Technology in Medicine, Institute of Science Tokyo, Tokyo, Japan
7 shared publications- Shigenori Kawabata
Department of Advanced Technology in Medicine, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan
7 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 4001105
A Coil-Embedded Beacon Pole for 3-D Localization of Surrounding Magnetic Flux Sensors
In this study, we propose a novel 3D localization method using a coil-embedded beacon pole and magnetoresistive-device-based magnetic flux sensors (MR sensors) aimed at underwater applications. The beacon pole is constructed by stacking multiple cylindrical modules, each containing three elliptic coils embedded in grooves on its side surface with mutually orthogonal plane normals. The coils are oriented at 54.74° with respect to the cylinder axis and separated by 120° in azimuth. By detecting the magnetic fields generated by the coils embedded in the pole, the magnetic sensors can determine their positions in axial, radial, and circumferential directions relative to the pole. Low-frequency (30–180 Hz) fields, which are advantageous for applications in water, are generated by the pole and can be detected by the MR sensors with a high signal-to-noise ratio. Numerical simulations indicated that, although the coils were discretely arranged at 120° intervals in azimuth, the localization performance was remained effectively axisymmetric. Uniform precision was achieved in all directions, and a localization uncertainty of approximately less than 2 mm was obtained within a 1-m-diameter region around the beacon pole. However, in practical experiments using a small-scale prototype of the beacon pole, the uncertainty was limited to better than 11 mm within a 0.6-m-diameter region, reflecting real-world measurement constraints. Real-time positioning of the magnetic sensor was successfully demonstrated achieving position updates at approximately 20 Hz.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 4001105
Open AccessA Coil-Embedded Beacon Pole for 3-D Localization of Surrounding Magnetic Flux Sensors
In this study, we propose a novel 3D localization method using a coil-embedded beacon pole and magnetoresistive-device-based magnetic flux sensors (MR sensors) aimed at underwater applications. The beacon pole is constructed by stacking multiple cylindrical modules, each containing three elliptic coils embedded in grooves on its side surface with mutually orthogonal plane normals. The coils are oriented at 54.74° with respect to the cylinder axis and separated by 120° in azimuth. By detecting the magnetic fields generated by the coils embedded in the pole, the magnetic sensors can determine their positions in axial, radial, and circumferential directions relative to the pole. Low-frequency (30–180 Hz) fields, which are advantageous for applications in water, are generated by the pole and can be detected by the MR sensors with a high signal-to-noise ratio. Numerical simulations indicated that, although the coils were discretely arranged at 120° intervals in azimuth, the localization performance was remained effectively axisymmetric. Uniform precision was achieved in all directions, and a localization uncertainty of approximately less than 2 mm was obtained within a 1-m-diameter region around the beacon pole. However, in practical experiments using a small-scale prototype of the beacon pole, the uncertainty was limited to better than 11 mm within a 0.6-m-diameter region, reflecting real-world measurement constraints. Real-time positioning of the magnetic sensor was successfully demonstrated achieving position updates at approximately 20 Hz.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 4001205
Magnetic Source Localization Based on Magnetic Dipole-Array Method for Demagnetizing Field Estimation
In this study, we address magnetic source localization under conditions where both the source and magnetic sensors are placed close to magnetic shielding material. In such environments, the magnetic field generated by the magnetic source is distorted by demagnetizing fields induced by the magnetic shielding material, leading to degradation of estimation accuracy. To address this problem, we apply the Magnetic Dipole-array Method (MDM), previously proposed to account for the influence of demagnetizing fields, to magnetic source localization. In addition, we design a cylindrical magnetic dipole array specifically for cylindrical magnetic shields, in contrast to the planar dipole array configurations for rectangular magnetic shields used in our previous studies. Experiments of magnetic source localization using coils, room-temperature magnetic sensors, and a compact cylindrical magnetic shield were conducted. The results showed that the proposed method improved the estimation accuracy, reducing the average position error from 2.7 mm to 0.59 mm compared with conventional approaches that do not account for demagnetizing fields. This study provides a fundamental investigation under controlled experimental conditions as a basis for future application of MDM to biomagnetic measurements.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 4001205
Magnetic Source Localization Based on Magnetic Dipole-Array Method for Demagnetizing Field Estimation
In this study, we address magnetic source localization under conditions where both the source and magnetic sensors are placed close to magnetic shielding material. In such environments, the magnetic field generated by the magnetic source is distorted by demagnetizing fields induced by the magnetic shielding material, leading to degradation of estimation accuracy. To address this problem, we apply the Magnetic Dipole-array Method (MDM), previously proposed to account for the influence of demagnetizing fields, to magnetic source localization. In addition, we design a cylindrical magnetic dipole array specifically for cylindrical magnetic shields, in contrast to the planar dipole array configurations for rectangular magnetic shields used in our previous studies. Experiments of magnetic source localization using coils, room-temperature magnetic sensors, and a compact cylindrical magnetic shield were conducted. The results showed that the proposed method improved the estimation accuracy, reducing the average position error from 2.7 mm to 0.59 mm compared with conventional approaches that do not account for demagnetizing fields. This study provides a fundamental investigation under controlled experimental conditions as a basis for future application of MDM to biomagnetic measurements.
- Open Access
- 14 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (22) , 41200-41208
Sensor Array Geometry Acquisition by Spherical Coil Array for OPM-Based MEG System
Precise determination of sensor array geometry is critical for accurate magnetic source localization in magnetoencephalography (MEG). This is particularly important for optically pumped atomic magnetometer (OPM)-based MEG systems, since their sensor array configuration can be flexibly modified depending on the subject’s head shape. In this study, we demonstrate, for the first time, that a spherical coil array—previously validated for SQUID-based MEG—can also be applied to OPM-based MEG systems. Using a dry-type MEG phantom equipped with 49 equivalent current dipoles (ECDs), we evaluated the sensor array geometry obtained with the spherical coil array. We compared it with that derived from the method originally implemented in the OPM-MEG system. To isolate geometry-related effects, we incorpolated two procedures: template fitting for field extraction and a recursive coordinate system transformation. These procedures minimized uncertainties not associated with the sensor array geometry in the ECD estimation. The results show that spherical coil calibration reduced the variability in the positional displacement between estimated and assumed ECDs in close (on-scalp) recordings by approximately 50%, as confirmed by 95% credible intervals. In the far mode, improvements were present but less pronounced. These findings indicate that the spherical coil array calibration enhances OPM-MEG source estimation by providing more accurate orientations and sensitivities. As a result, OPM-MEG measurements become more reliable, enabling broader applications in research and clinical settings.
- 14 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (22) , 41200-41208
Open AccessSensor Array Geometry Acquisition by Spherical Coil Array for OPM-Based MEG System
Precise determination of sensor array geometry is critical for accurate magnetic source localization in magnetoencephalography (MEG). This is particularly important for optically pumped atomic magnetometer (OPM)-based MEG systems, since their sensor array configuration can be flexibly modified depending on the subject’s head shape. In this study, we demonstrate, for the first time, that a spherical coil array—previously validated for SQUID-based MEG—can also be applied to OPM-based MEG systems. Using a dry-type MEG phantom equipped with 49 equivalent current dipoles (ECDs), we evaluated the sensor array geometry obtained with the spherical coil array. We compared it with that derived from the method originally implemented in the OPM-MEG system. To isolate geometry-related effects, we incorpolated two procedures: template fitting for field extraction and a recursive coordinate system transformation. These procedures minimized uncertainties not associated with the sensor array geometry in the ECD estimation. The results show that spherical coil calibration reduced the variability in the positional displacement between estimated and assumed ECDs in close (on-scalp) recordings by approximately 50%, as confirmed by 95% credible intervals. In the far mode, improvements were present but less pronounced. These findings indicate that the spherical coil array calibration enhances OPM-MEG source estimation by providing more accurate orientations and sensitivities. As a result, OPM-MEG measurements become more reliable, enabling broader applications in research and clinical settings.
- Open Access
- 14 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Magnetics Letters
- Vol. 16 (1949307X) , 1-5
Fast Acquisition of Sensor Array Geometry of Whole-Head Magnetoencephalograph Systems Using a Neural Network
Acquiring position, orientation, and sensitivity of magnetometers in a helmet-shaped sensor array is crucial for accurate current source reconstruction in magnetoencephalography. To determine these parameters for each magnetometer, we utilize a spherical calibration coil array. In our previous study, the position and orientation of each magnetometer were determined as the solution of an inverse problem through a numerical search that minimized the difference between the theoretical magnetic field signals from each coil and the measured signals detected by the magnetometer. In this study, we applied a deep neural network to estimate the position and orientation of each magnetometer in the helmet-shaped sensor array without solving inverse problem. A total of 223 million pairs of a given magnetometer's five parameters (x, y, z, θ, and ϕ) and the corresponding theoretical magnetic field signals from the coils were used to train the neural network. The training process required approximately 53 hours using a commercially available GPU-equipped computer. The trained neural network was then applied to acquire the sensor geometry from magnetic field data obtained during the conventional calibration procedure for a 160-channel whole-head magnetoencephalograph system using a spherical calibration coil array. The position and orientation of each magnetometer estimated by this method deviated by an average of 0.65 mm and 0.51 degree, respectively, from those obtained via the conventional inverse problem approach. The acquisition of the geometry for all 160 magnetometers required less than 8 ms. With such high-speed acquisition, this approach opens possibilities for future applications in acquiring positional information of wearable sensor arrays whose structures change in real-time.
- 14 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Magnetics Letters
- Vol. 16 (1949307X) , 1-5
Open AccessFast Acquisition of Sensor Array Geometry of Whole-Head Magnetoencephalograph Systems Using a Neural Network
Acquiring position, orientation, and sensitivity of magnetometers in a helmet-shaped sensor array is crucial for accurate current source reconstruction in magnetoencephalography. To determine these parameters for each magnetometer, we utilize a spherical calibration coil array. In our previous study, the position and orientation of each magnetometer were determined as the solution of an inverse problem through a numerical search that minimized the difference between the theoretical magnetic field signals from each coil and the measured signals detected by the magnetometer. In this study, we applied a deep neural network to estimate the position and orientation of each magnetometer in the helmet-shaped sensor array without solving inverse problem. A total of 223 million pairs of a given magnetometer's five parameters (x, y, z, θ, and ϕ) and the corresponding theoretical magnetic field signals from the coils were used to train the neural network. The training process required approximately 53 hours using a commercially available GPU-equipped computer. The trained neural network was then applied to acquire the sensor geometry from magnetic field data obtained during the conventional calibration procedure for a 160-channel whole-head magnetoencephalograph system using a spherical calibration coil array. The position and orientation of each magnetometer estimated by this method deviated by an average of 0.65 mm and 0.51 degree, respectively, from those obtained via the conventional inverse problem approach. The acquisition of the geometry for all 160 magnetometers required less than 8 ms. With such high-speed acquisition, this approach opens possibilities for future applications in acquiring positional information of wearable sensor arrays whose structures change in real-time.
- Open Access
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Fast Acquisition of Sensor Array Geometry of Whole-head Magnetoencephalograph Systems Using Neural Network
Acquiring position, orientation, and sensitivity of magnetometers in a helmet-shaped sensor array is crucial for accurate current source reconstruction in magnetoencephalography. To determine these parameters for each magnetometer, we utilize a spherical calibration coil array. In our previous study, the position and orientation of each magnetometer were determined as the solution of an inverse problem through a numerical search that minimized the difference between the theoretical magnetic field signals from each coil and the measured signals detected by the magnetometer. In this study, we applied a deep neural network to estimate the position and orientation of each magnetometer in the helmet-shaped sensor array without solving inverse problem. A total of 223 million pairs of a given magnetometer's five parameters (x, y, z, θ, and φ) and the corresponding theoretical magnetic field signals from the coils were used to train the neural network. The training process required approximately 53 hours using a commercially available GPU-equipped computer. The trained neural network was then applied to acquire the sensor geometry from magnetic field data obtained during the conventional calibration procedure for a 160-channel whole-head magnetoencephalograph system using a spherical calibration coil array. The position and orientation of each magnetometer estimated by this method deviated by an average of 0.65 mm and 0.51 degree, respectively, from those obtained via the conventional inverse problem approach. The acquisition of the geometry for all 160 magnetometers required less than 8 ms. With such high-speed acquisition, this approach opens possibilities for future applications in acquiring positional information of wearable sensor arrays whose structures change in real-time.
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessFast Acquisition of Sensor Array Geometry of Whole-head Magnetoencephalograph Systems Using Neural Network
Acquiring position, orientation, and sensitivity of magnetometers in a helmet-shaped sensor array is crucial for accurate current source reconstruction in magnetoencephalography. To determine these parameters for each magnetometer, we utilize a spherical calibration coil array. In our previous study, the position and orientation of each magnetometer were determined as the solution of an inverse problem through a numerical search that minimized the difference between the theoretical magnetic field signals from each coil and the measured signals detected by the magnetometer. In this study, we applied a deep neural network to estimate the position and orientation of each magnetometer in the helmet-shaped sensor array without solving inverse problem. A total of 223 million pairs of a given magnetometer's five parameters (x, y, z, θ, and φ) and the corresponding theoretical magnetic field signals from the coils were used to train the neural network. The training process required approximately 53 hours using a commercially available GPU-equipped computer. The trained neural network was then applied to acquire the sensor geometry from magnetic field data obtained during the conventional calibration procedure for a 160-channel whole-head magnetoencephalograph system using a spherical calibration coil array. The position and orientation of each magnetometer estimated by this method deviated by an average of 0.65 mm and 0.51 degree, respectively, from those obtained via the conventional inverse problem approach. The acquisition of the geometry for all 160 magnetometers required less than 8 ms. With such high-speed acquisition, this approach opens possibilities for future applications in acquiring positional information of wearable sensor arrays whose structures change in real-time.
- 20 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (10) , 1-6
Simultaneous Measurements of Magnetomyographic and Magnetocardiographic Signals Using SQUIDs and Relocatable Magnetoresistive-Device-Based Flux Sensors
Biomagnetic field measurement is effective for the noninvasive investigation of electrical activities in a living body. Recent advancements in room-temperature magnetic sensors, such as magnetoresistance (MR) devices, have enabled their use in detecting weak magnetic fields from the body surface, which were earlier detectable only with superconducting interference device superconducting quantum interference device (SQUID) magnetic sensors. Although magnetoresistive-device-based sensors have inferior magnetic field resolution compared to SQUID sensors, they offer high flexibility for sensor placement. In this study, a relocatable magnetoresistive-device-based sensor array was applied to detect biomagnetic signals alongside a conventional 132-ch SQUID-based sensor array for magnetoneurography to simultaneously record biomagnetic signals, such as magnetomyographic or magnetocardiographic signals. The results indicated that both sensor systems could successfully detect the significant biomagnetic signals with negligible interference between them.
- 20 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (10) , 1-6
Simultaneous Measurements of Magnetomyographic and Magnetocardiographic Signals Using SQUIDs and Relocatable Magnetoresistive-Device-Based Flux Sensors
Biomagnetic field measurement is effective for the noninvasive investigation of electrical activities in a living body. Recent advancements in room-temperature magnetic sensors, such as magnetoresistance (MR) devices, have enabled their use in detecting weak magnetic fields from the body surface, which were earlier detectable only with superconducting interference device superconducting quantum interference device (SQUID) magnetic sensors. Although magnetoresistive-device-based sensors have inferior magnetic field resolution compared to SQUID sensors, they offer high flexibility for sensor placement. In this study, a relocatable magnetoresistive-device-based sensor array was applied to detect biomagnetic signals alongside a conventional 132-ch SQUID-based sensor array for magnetoneurography to simultaneously record biomagnetic signals, such as magnetomyographic or magnetocardiographic signals. The results indicated that both sensor systems could successfully detect the significant biomagnetic signals with negligible interference between them.
- 12 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1
Errata to “A Spherical Coil Array for the Calibration of Whole-Head Magnetoencephalograph Systems”
In the above article [1], there is an error in (9). The correct equation is as below: \begin{equation*} \hat {\sigma }^{2}=\frac {\sum _{j=1}^{16} \Delta V_{j}^{2}}{16-6} =\frac {\sum _{j=1}^{16}\left ({{V_{\mathrm {cal}, j}-V_{\mathrm {meas}, j}}}\right )^{2}}{10}.\end{equation*} The above error resulted in the calculated values for uncertainty displayed in Fig. 5 and Table III being smaller by 18%. The figure and table reflecting the correct values are as follows:TABLE IIISensor Parameters With Uncertainties channelx(mm)y(mm)z(mm) $n_x$ $n_y$ $n_z$ g(nT/V)CH240.39±0.5820.72±0.56163.84±0.410.1028±0.00840.1757±0.00810.9791±0.00171.176±0.011CH28116.76±0.22-14.51±0.293.61±0.230.9929±0.0008-0.1178±0.00690.0157±0.00691.135±0.008CH55-10.63±0.32116.38±0.2122.02±0.440.0262±0.00780.9993±0.0003-0.0254±0.00031.065±0.008CH115-135.52±0.577.07±0.6278.59±0.60-0.2907±0.00280.3784±0.00960.8788±0.00271.137±0.016CH140-19.74±0.42-116.89±0.3226.20±0.56-0.0926±0.0094-0.9951±0.00110.0352±0.00141.038±0.009The values following the plus-minus signs (±) correspond to uncertainties with a coverage factor $k=1$ . Fig. 5.Fig. 5.- 12 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1
Errata to “A Spherical Coil Array for the Calibration of Whole-Head Magnetoencephalograph Systems”
In the above article [1], there is an error in (9). The correct equation is as below: \begin{equation*} \hat {\sigma }^{2}=\frac {\sum _{j=1}^{16} \Delta V_{j}^{2}}{16-6} =\frac {\sum _{j=1}^{16}\left ({{V_{\mathrm {cal}, j}-V_{\mathrm {meas}, j}}}\right )^{2}}{10}.\end{equation*} The above error resulted in the calculated values for uncertainty displayed in Fig. 5 and Table III being smaller by 18%. The figure and table reflecting the correct values are as follows:TABLE IIISensor Parameters With Uncertainties channelx(mm)y(mm)z(mm) $n_x$ $n_y$ $n_z$ g(nT/V)CH240.39±0.5820.72±0.56163.84±0.410.1028±0.00840.1757±0.00810.9791±0.00171.176±0.011CH28116.76±0.22-14.51±0.293.61±0.230.9929±0.0008-0.1178±0.00690.0157±0.00691.135±0.008CH55-10.63±0.32116.38±0.2122.02±0.440.0262±0.00780.9993±0.0003-0.0254±0.00031.065±0.008CH115-135.52±0.577.07±0.6278.59±0.60-0.2907±0.00280.3784±0.00960.8788±0.00271.137±0.016CH140-19.74±0.42-116.89±0.3226.20±0.56-0.0926±0.0094-0.9951±0.00110.0352±0.00141.038±0.009The values following the plus-minus signs (±) correspond to uncertainties with a coverage factor $k=1$ . Fig. 5.Fig. 5.- Open Access
- 16 April 2024
- Published by Frontiers Media SA in Frontiers in Medical Technology
- Vol. 6, 1351905
SQUID magnetoneurography: an old-fashioned yet new tool for noninvasive functional imaging of spinal cords and peripheral nerves
We are engaged in the development and clinical application of a neural magnetic field measurement system that utilizes biomagnetic measurements to observe the activity of the spinal cord and peripheral nerves. Unlike conventional surface potential measurements, biomagnetic measurements are not affected by the conductivity distribution within the body, making them less influenced by the anatomical structure of body tissues. Consequently, functional testing using biomagnetic measurements can achieve higher spatial resolution compared to surface potential measurements. The neural magnetic field measurement, referred to as magnetoneurography, takes advantage of these benefits to enable functional testing of the spinal cord and peripheral nerves, while maintaining high spatial resolution and noninvasiveness. Our magnetoneurograph system is based on superconducting quantum interference devices (SQUIDs) similar to the conventional biomagnetic measurement systems. Various design considerations have been incorporated into the SQUID sensor array structure and signal processing software to make it suitable for detecting neural signal propagation along spinal cord and peripheral nerve. The technical validation of this system began in 1999 with a 3-channel SQUID system. Over the course of more than 20 years, we have continued technological development through medical-engineering collaboration, and in the latest prototype released in 2020, neural function imaging of the spinal cord and peripheral nerves, which could also be applied for the diagnosis of neurological disorders, has become possible. This paper provides an overview of the technical aspects of the magnetoneurograph system, covering the measurement hardware and software perspectives for providing diagnostic information, and its applications. Additionally, we discuss the integration with a helium recondensing system, which is a key factor in reducing running costs and achieving practicality in hospitals.
- 16 April 2024
- Published by Frontiers Media SA in Frontiers in Medical Technology
- Vol. 6, 1351905
Open AccessSQUID magnetoneurography: an old-fashioned yet new tool for noninvasive functional imaging of spinal cords and peripheral nerves
We are engaged in the development and clinical application of a neural magnetic field measurement system that utilizes biomagnetic measurements to observe the activity of the spinal cord and peripheral nerves. Unlike conventional surface potential measurements, biomagnetic measurements are not affected by the conductivity distribution within the body, making them less influenced by the anatomical structure of body tissues. Consequently, functional testing using biomagnetic measurements can achieve higher spatial resolution compared to surface potential measurements. The neural magnetic field measurement, referred to as magnetoneurography, takes advantage of these benefits to enable functional testing of the spinal cord and peripheral nerves, while maintaining high spatial resolution and noninvasiveness. Our magnetoneurograph system is based on superconducting quantum interference devices (SQUIDs) similar to the conventional biomagnetic measurement systems. Various design considerations have been incorporated into the SQUID sensor array structure and signal processing software to make it suitable for detecting neural signal propagation along spinal cord and peripheral nerve. The technical validation of this system began in 1999 with a 3-channel SQUID system. Over the course of more than 20 years, we have continued technological development through medical-engineering collaboration, and in the latest prototype released in 2020, neural function imaging of the spinal cord and peripheral nerves, which could also be applied for the diagnosis of neurological disorders, has become possible. This paper provides an overview of the technical aspects of the magnetoneurograph system, covering the measurement hardware and software perspectives for providing diagnostic information, and its applications. Additionally, we discuss the integration with a helium recondensing system, which is a key factor in reducing running costs and achieving practicality in hospitals.
- Open Access
- 6 March 2024
- Published by Elsevier in Clinical Neurophysiology
- Vol. 161, 180-187
Assessing ulnar neuropathy at the elbow using magnetoneurography
- 6 March 2024
- Published by Elsevier in Clinical Neurophysiology
- Vol. 161, 180-187
Open AccessAssessing ulnar neuropathy at the elbow using magnetoneurography
- Open Access
- 13 October 2023
- Published by Elsevier in Clinical Neurophysiology
- Vol. 156, 89-97
Evaluation of electrical activity at the carpal tunnel area in response to median nerve elbow stimulation using magnetoneurography
- 13 October 2023
- Published by Elsevier in Clinical Neurophysiology
- Vol. 156, 89-97
Open AccessEvaluation of electrical activity at the carpal tunnel area in response to median nerve elbow stimulation using magnetoneurography