Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohammed Iqbal has a total of 94 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Assessing Retinal Function Alterations Due to Digital Device Use: A Study of Computer Vision Syndrome in Medical Students

    by Mohammed Iqbal, Bishoy Fahim, Sandra Emad, Shaimaa Fadel, Noha SalahEldeen, Fathy Gad, Somya Zein, Mervat Elgharieb

    Digital devices, mainly smartphone with its time-consuming applications and 24/7 internet connection, are accused of the being the main cause of severe distraction and excessive disruptions with fragmentation of everyday life that adversely interrupts the adults and youth lifestyles, health, education and social or family relationships. The medical students underwent objective ophthalmic examination to confirm or exclude CVS diagnosis based on Iqbal’s four major criteria for accurate CVS diagnosis. Screen-induced foveal dysfunction (SFD) has been recorded using the multifocal electroretinogram to prove the retinal function alterations due to excessive digital device use. Based on our outcomes, we have defined the term screen-induced foveal dysfunction (SFD) as “the multifocal electroretinogram reduced foveal responses below standard normal ranges that are mostly temporary, reversible and usually associated with reduced visual acuities and performances in computer vision syndrome positive-cases”. SFD is characterized by temporary impermanent reduced foveal responses that associates reduced visual acuities and performances in CVS positive-cases. Strict reduction or cessation of exposure to digital screens and/or electronic devices that contains light emitting diodes (LEDs) for 4 weeks results in spontaneous resolution of cone adaptation/saturation thus eventually the retina regains its normal foveal functions and responses with normal visual acuities and performances. Iqbal’s instructions are helpful in reducing the medical students’ screen-time to reverse the SFD thus improving the foveal responses in CVS positive-cases. It is recommended that the screen-time not exceed 3 hours daily to avoid the visual impacts and sequelae of the digital environment.


  • Open Access

    Thyroid gland dysfunction and keratoconus

    by Omar M Said, Mohammed Iqbal, Ahmed El-Massry, Mervat Elshabrawy Elgharieb, Mohamed Mady, Ahmed M Sharawy, Khaled Abdelaziz

    Background: The association between keratoconus and thyroid gland dysfunction (TGD) remains controversial. We aimed to determine the frequency of keratoconus among patients with laboratory-confirmed, treatment-naive TGD compared with that of age- and sex-matched healthy controls. Moreover, we investigated the potential relationship between TGD and corneal topographic and tomographic parameters. Methods: This multicenter, cross-sectional study recruited individuals with treatment-naive, laboratory-confirmed TGD and sex- and age-matched healthy controls. Demographic and ophthalmic data of all participants were recorded. All participants underwent comprehensive ocular examinations and corneal tomography. Patterns of symmetric bowtie, asymmetric bowtie, asymmetric bowtie/superior steep, asymmetric bowtie/inferior steep, or asymmetric bowtie pattern with a skewed radial axis were documented if present. Furthermore, the maximum simulated keratometry value (Kmax), corneal thinnest thickness (CTT), and back elevation (BE) values were recorded. We measured the serum concentrations of thyroid-stimulating hormone (TSH) and thyroid hormones (free thyroxine [FT4] and free tri-iodothyronine [FT3]) using an immunoassay method. Results: We included 200 eyes of 200 individuals with TGD and 200 eyes of 200 healthy age- and sex-matched controls, with female predominance in both groups. The mean FT4 concentration was significantly higher and the TSH concentration was significantly lower in the TGD group than in the control group (both P < 0.0001), whereas the FT3 level was comparable between groups (P > 0.05). In the TGD group, the frequencies of hyperthyroidism and hypothyroidism were 190 (95%) and 10 (5%), respectively. We found significantly lower mean CTT, higher Kmax, and greater BE values with a significantly higher frequency of abnormal topographic patterns among eyes in the TGD group than in controls (all P < 0.05). The frequency of eyes with keratoconus was significantly higher in the TGD (7.5%) group than in the control (0.5%) group (P < 0.0001). Except for a statistically significant correlation of Kmax (r = - 0.23, P < 0.05) and CTT (r = + 0.15, P < 0.05) with TSH level in the TGD group, no significant correlation was found between corneal characteristics and thyroid profile in either group (all P > 0.05). Conclusions: We observed a higher frequency of keratoconus, with female predominance, in the TGD group. TGD was associated with significant changes in certain corneal topographic and tomographic parameters. Compared with healthy controls, individuals with TGD demonstrated increased Kmax and BE values with more corneal thinning, highlighting the potential association between keratoconus and TGD. However, further large-scale longitudinal studies are essential to confirm our findings.


  • Open Access

    Visual, ocular surface, and extraocular diagnostic criteria for determining the prevalence of computer vision syndrome: a cross-sectional smart-survey-based study

    by Mohammed Iqbal, Ahmed Elmassry, Mervat Elgharieb, Omar Said, Ahmed Saeed, Tamer Ibrahim, Ahmed Kotb, Mahmoud Abdelhalim, Samir Shoughy, Akram Elgazzar, et al.

    Background: The American Optometric Association defines computer vision syndrome (CVS), also known as digital eye strain, as “a group of eye- and vision-related problems that result from prolonged computer, tablet, e-reader and cell phone use”. We aimed to create a well-structured, valid, and reliable questionnaire to determine the prevalence of CVS, and to analyze the visual, ocular surface, and extraocular sequelae of CVS using a novel and smart self-assessment questionnaire. Methods: This multicenter, observational, cross-sectional, descriptive, survey-based, online study included 6853 complete online responses of medical students from 15 universities. All participants responded to the updated, online, fourth version of the CVS questionnaire (CVS-F4), which has high validity and reliability. CVS was diagnosed according to five basic diagnostic criteria (5DC) derived from the CVS-F4. Respondents who fulfilled the 5DC were considered CVS cases. The 5DC were then converted into a novel five-question self-assessment questionnaire designated as the CVS-Smart. Results: Of 10000 invited medical students, 8006 responded to the CVS-F4 survey (80% response rate), while 6853 of the 8006 respondents provided complete online responses (85.6% completion rate). The overall CVS prevalence was 58.78% (n = 4028) among the study respondents; CVS prevalence was higher among women (65.87%) than among men (48.06%). Within the CVS group, the most common visual, ocular surface, and extraocular complaints were eye strain, dry eye, and neck/shoulder/back pain in 74.50% (n = 3001), 58.27% (n = 2347), and 80.52% (n = 3244) of CVS cases, respectively. Notably, 75.92% (3058/4028) of CVS cases were involved in the Mandated Computer System Use Program. Multivariate logistic regression analysis revealed that the two most statistically significant diagnostic criteria of the 5DC were greater than or equal to 2 symptoms/attacks per month over the last 12 months (odds ratio [OR] = 204177.2; P <0.0001) and symptoms/attacks associated with screen use (OR = 16047.34; P <0.0001). The CVS-Smart demonstrated a Cronbach’s alpha reliability coefficient of 0.860, Guttman split-half coefficient of 0.805, with perfect content and construct validity. A CVS-Smart score of 7–10 points indicated the presence of CVS. Conclusions: The visual, ocular surface, and extraocular diagnostic criteria for CVS constituted the basic components of CVS-Smart. CVS-Smart is a novel, valid, reliable, subjective instrument for determining CVS diagnosis and prevalence and may provide a tool for rapid periodic assessment and prognostication. Individuals with positive CVS-Smart results should consider modifying their lifestyles and screen styles and seeking the help of ophthalmologists and/or optometrists. Higher institutional authorities should consider revising the Mandated Computer System Use Program to avoid the long-term consequences of CVS among university students. Further research must compare CVS-Smart with other available metrics for CVS, such as the CVS questionnaire, to determine its test-retest reliability and to justify its widespread use.


  • Open Access

    Outcomes of the Q value-based nomogram in managing pediatric versus adult keratoconus: a prospective interventional study

    by Mohammed Iqbal, Abdallah Hammour, Ahmed Elsayed, Ahmed Gad

    Background: Keratoconus (KCN) is an ectatic disorder of the cornea characterized by stromal weakness and apical protrusion of the cornea, and is associated with a gradual and painless reduction in visual acuity. KCN in pediatric patients has certain important characteristics, such as a progressive and aggressive nature. We aimed to analyze the visual, refractive, and topographic outcomes of implanting a single 210° arc-length Keraring segment according to a novel, objective, Q value-based nomogram (Q-N) for the treatment of pediatric versus adult KCN. Methods: This prospective, multicenter, non-randomized, open-label trial included 47 eyes of 47 patients who were allocated to one of two groups. The adult group included 33 eyes of patients greater than or equal to 18 years of age, whereas the pediatric group included 14 eyes of patients aged 14 – 17 years. All patients underwent femtosecond laser-assisted implantation of a single 210° arc-length Keraring segment according to the Q-N and were followed up for 6 months. All eyes underwent visual acuity measurement, cycloplegic refraction, and corneal topography at baseline and 6 months after surgery. Results: The study groups were comparable in terms of sex proportions and KCN grades (both P > 0.05). The adult group exhibited significant postoperative improvements in mean uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), sphere, cylinder, spherical equivalent (SE), and Kmax (all P < 0.001) with a mean change of -0.56 logarithm of the minimal angle of resolution (logMAR), - 0.40 logMAR, 3.07 diopters (D), 0.70 D, 3.42 D, and - 5.26 D, respectively. The pediatric group exhibited significant postoperative improvements in mean UDVA, CDVA, sphere, SE, and Kmax (all P < 0.05) with a mean change of - 0.62 logMAR, - 0.34 logMAR, 3.18 D, 3.67 D, and - 5.37 D, respectively. There were no significant differences between the groups in terms of the mean change in visual, refractive, and topographic variables (all P > 0.05). No postoperative complications were observed in either group. Conclusions: Use of the objective Q-N was efficient in the treatment of pediatric KCN, with postoperative improvements in the mean visual, refractive, and topographic parameters, comparable to outcomes in adult keratoconus. Q-N achieved good corneal remodeling with subsequent improvements in visual, refractive, and topographic outcomes in both adult and pediatric patients with keratoconus. To verify our preliminary findings, we recommend further multicenter randomized clinical trials using the Q-N nomogram in a larger sample of pediatric patients with KCN as an adjunct treatment before or after CXL.


  • Letter to the editor regarding “TFOS Lifestyle: Impact of the digital environment on the ocular surface”

    by Mohammed Iqbal, Ahmed Elmassry, Mervat Elgharieb, Hosam Elzembely, Omar Said


  • Analysis of the outcomes of three different cross‐linking protocols for treatment of paediatric keratoconus: A multicentre randomized controlled trial

    by Mohammed Iqbal, Ahmed Gad, Ahmed Kotb, Mahmoud Abdelhalim

    Purpose: To analyse long‐term outcomes of standard cross‐linking (SCXL), accelerated cross‐linking (ACXL) and transepithelial cross‐linking (TCXL) in the treatment of progressive paediatric keratoconus regarding stability, safety and efficacy.Methods: This prospective multicentre randomized controlled trial included 97 eyes of 97 paediatric patients with stages I–III ABCD keratoconus grading system, who were randomized into three groups; SCXL group (control group, n = 32; 3 mW/cm2 × 30 min/5.4 J/cm2), ACXL (n = 33; 18 mW/cm2 × 5 min/5.4 J/cm2) and TCXL (n = 32; 18 mW/cm2 × 5 min/5.4 J/cm2). Subjective refraction, uncorrected and corrected visual acuity, keratometry and pachymetry measurements using corneal topography were recorded preoperatively and 1, 2 and 3 years postoperatively.Results: SCXL group exhibited significant successive improvements in the mean visual, refractive and keratometric parameters throughout the entire postoperative 3 years while ACXL group exhibited significant improvements in visual and keratometric parameters in the first postoperative year that remained stable in second and third postoperative years. TCXL group exhibited significant progressive deterioration in all mean parameters compared to SCXL and ACXL (p < 0.0001). Both SCXL and ACXL revealed final 100% success rate with good stability while TCXL revealed final 22% failure rate with keratoconus progression (p < 0.0001).Conclusion: SCXL and ACXL were comparable in halting keratoconus progression and achieved good stability and safety; however, SCXL was more efficient than ACXL as it yielded greater significant postoperative mean visual, refractive and keratometric improvements achieving smoother corneal remodelling. Both SCXL and ACXL were much superior to TCXL. SCXL is the best CXL treatment option for paediatric keratoconus while ACXL is a good and effective alternative.


  • Open Access

    Analysis of the Outcomes of the Screen-Time Reduction in Computer Vision Syndrome: A Cohort Comparative Study [Response to Letter]

    by Mohammed Iqbal, Ahmed Gad

    Response to Letter in regards to Analysis of the Outcomes of the Screen-Time Reduction in Computer Vision Syndrome: A Cohort Comparative Study [Letter]


  • Open Access

    Analysis of the Outcomes of the Screen-Time Reduction in Computer Vision Syndrome: A Cohort Comparative Study

    by Mohammed Iqbal, Ashraf Soliman, Ola Ibrahim, Ahmed Gad

    Purpose: To analyze the outcomes of screen-time reduction on the foveal responses that associates computer vision syndrome (CVS) using multifocal electroretinogram (mfERG) examination. Methods: This prospective multicenter cohort comparative study included 49 eyes of 49 medical students divided into two groups. Group A (control group) included 25 eyes with no CVS diagnosis while group B (CVS group) included 24 eyes with CVS diagnosis. All students responded to the valid and reliable CVS-Form 3 (CVS-F3) questionnaire and underwent complete ophthalmic and mfERG examinations twice at the time recruitment in the study and four weeks after strict reduction of the daily screen-hours to ≤ 1 screen-hour daily to document associated foveal responses. Results: We documented statistically significant reduction in foveal responses in CVS versus control groups in mean mfERG Rings 1, 2, and 5 with Quadrants 1, 2, and 4 (P=< 0.0001, 0.0001, 0.0003, 0.001, 0.002, and 0.006, respectively). Following the screen-time reduction, the second mfERG examination revealed significant post-reduction improvements in foveal responses in CVS group particularly in mean mfERG Rings 1, 2, 3, and 5 with Quadrants 1 and 4 (P=< 0.0001, < 0.0001, 0.0005, 0.02, < 0.0001, and 0.04, respectively). Conclusion: This study documented the screen-induced foveal dysfunction that associates CVS using mfERG examination, which revealed remarkable significant improvements in foveal responses in the 4 weeks following strict screen-time reduction. These improvements were also associated with corresponding improvements in the visual performances. We suggest that the potential screen-induced foveal dysfunction outcomes might be reversible with strict screen-time reduction. We also recommend that educational institutional policies should limit online education-hours and redesign the mandated computer system use program to guard against visual sequelae of CVS. Clinical Trials Registration: ClinicalTrials.gov (ID: NCT04405648).