Thomas Töppel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas Töppel has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Robert Kühne
2 shared publicationsSebastian Schettler
2 shared publicationsWelf-Guntram Drossel
2 shared publicationsAlexander Raßloff
1 shared publicationAndré Till Zeuner
1 shared publication- Christian Rotsch
Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany
1 shared publication
Latest Publications
- Open Access
- 10 March 2026
- Published by Elsevier in International Journal of Fatigue
- Vol. 209
Computed tomography based investigation of critical defects and fatigue failure analysis of very high cycle fatigued Ti-6Al-4V produced by laser powder bed fusion
- 10 March 2026
- Published by Elsevier in International Journal of Fatigue
- Vol. 209
Open AccessComputed tomography based investigation of critical defects and fatigue failure analysis of very high cycle fatigued Ti-6Al-4V produced by laser powder bed fusion
- 31 January 2018
- Published by Springer Nature in JOM
- Vol. 70 (3) , 321-327
Structural Integration of Sensors/Actuators by Laser Beam Melting for Tailored Smart Components
- 31 January 2018
- Published by Springer Nature in JOM
- Vol. 70 (3) , 321-327
Structural Integration of Sensors/Actuators by Laser Beam Melting for Tailored Smart Components
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s232-s236
Network session 3: Therapy of diseases of the musculoskeletal system
The sampling of brain tissue in veterinary medicine usually underlies a freehand performance without exact localization. The aim of the project was the accuracy evaluation of a 3D-printed subject specific system for brain biopsy in dogs. At the beginning of the procedure, three small bone screws were fixed (bilateral and occipital/frontal) to the dog skull. Subsequently, three MR-markers filled with contrast agent were adapted and MRI scans performed (layer-thickness 1.0 mm). Within the MR images the coordinates of the target and entry point are determined by the surgeon. For evaluation an additional pre-CT (layer-thickness 0.7 mm) was realized. After image recording the MR-markers were removed. Due to a self-made algorithm a patient individual template was constructed. The final biopsy device made of ABS M30 was produced by a 3D printer (FDM).To perform the biopsy the device was connected with the already embedded bone screws. Through a guidance track the skull was minimally invasive accessed at the intended location. Controlled by a depth stop the biopsy needle could be exactly moved in a desired direction up to the target point. A further post-CT (thickness 0.7 mm) with inserted needle was performed to determine the final position of the biopsy needle tip. For receiving information about the difference between preoperative planned and achieved tip position the pre-CT was matched with the post-CT. Therefor 10 dog cadavers (n=20 target points) were applied. The results showed an accuracy of 0.58 mm ± 0.34 mm (ranging from 0.09 mm to 1.17 mm) between the preoperative planned and the achieved needle position. A patient specific 3D-printed biopsy system based on MR images was developed which enables a high precise brain biopsy. Moreover, the system matches up to current costly diagnosis techniques of image-guided neurosurgery and robot systems. Prospectively, it shall be transferred to human medicine
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s232-s236
Network session 3: Therapy of diseases of the musculoskeletal system
The sampling of brain tissue in veterinary medicine usually underlies a freehand performance without exact localization. The aim of the project was the accuracy evaluation of a 3D-printed subject specific system for brain biopsy in dogs. At the beginning of the procedure, three small bone screws were fixed (bilateral and occipital/frontal) to the dog skull. Subsequently, three MR-markers filled with contrast agent were adapted and MRI scans performed (layer-thickness 1.0 mm). Within the MR images the coordinates of the target and entry point are determined by the surgeon. For evaluation an additional pre-CT (layer-thickness 0.7 mm) was realized. After image recording the MR-markers were removed. Due to a self-made algorithm a patient individual template was constructed. The final biopsy device made of ABS M30 was produced by a 3D printer (FDM).To perform the biopsy the device was connected with the already embedded bone screws. Through a guidance track the skull was minimally invasive accessed at the intended location. Controlled by a depth stop the biopsy needle could be exactly moved in a desired direction up to the target point. A further post-CT (thickness 0.7 mm) with inserted needle was performed to determine the final position of the biopsy needle tip. For receiving information about the difference between preoperative planned and achieved tip position the pre-CT was matched with the post-CT. Therefor 10 dog cadavers (n=20 target points) were applied. The results showed an accuracy of 0.58 mm ± 0.34 mm (ranging from 0.09 mm to 1.17 mm) between the preoperative planned and the achieved needle position. A patient specific 3D-printed biopsy system based on MR images was developed which enables a high precise brain biopsy. Moreover, the system matches up to current costly diagnosis techniques of image-guided neurosurgery and robot systems. Prospectively, it shall be transferred to human medicine