AKAnna Klysik

Anna Klysik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anna Klysik has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Piotr Jurowski

    Department of Ophthalmology, Medical University of Lodz, Zeromskiego 113, 90-549 Lodz, Poland

    2 shared publications
  • Agnieszka Siejka

    1 shared publication
  • Dorota Korzycka

    Department of Ophthalmology, Hospital of the Ministry of Internal Affairs and Administration, Lodz, Poland

    1 shared publication
  • Elżbieta Hrabec

    Department of Medical Enzymology, Medical University of Lodz, Lodz, Poland

    1 shared publication
  • Julia Naduk-Kik

    Department of Medical Enzymology, Medical University of Lodz, Lodz, Poland

    1 shared publication
  • Katarzyna Kaszuba-Bartkowiak

    Department of Ophthalmology, Medical University of Lodz, Zeromskiego 113, 90-549 Lodz, Poland

    1 shared publication

Latest Publications

  • Open Access

    Corneal biomechanical changes and intraocular pressure in patients with thyroid orbitopathy

    by Zofia Pniakowska, Anna Klysik, Roman Gos, Piotr Jurowski

    To determine the relevance of the objective parameters addressing the altered biomechanical properties of cornea for glaucoma monitoring in patients with mild or moderate thyroid associated orbitopathy (TAO), and in healthy individuals. Twenty-five patients with TAO (group 1) and 25 healthy adults (group 2) were included to the study. Both groups were of a similar age and the ratio women:man. For each patient, the following parameters of both eyes were measured with ocular response analyzer (ORA): corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann correlated intraocular pressure (IOPg) and corneal compensated intraocular pressure (IOPcc). In both groups participating in our study, all measurements were performed within minutes to reduce the diurnal effects. The mean age in group 1 was 56±11y and 76% were women, 24% were men. The mean age in group 2 was 64±11y and 68% were women, 32% were men. CH correlated negatively with IOPg in group 1 (r (2)=0.10, P0.05). CRF mean value in group 2 (11.51±1.72 mm Hg) was higher than in group 1 (10.85±1.45 mm Hg) (P<0.05). IOPg strongly correlated with IOPcc in both groups (group 1: r (2)=0.79, P<0.0001; group 2: r (2)=0.85, P<0.0001). There was also strong correlation between CRF and CH in both populations: group 1: (r (2)=0.58, P<0.0001), group 2: (r (2)=0.41, P<0.0001). Biomechanical parameters of cornea, as quantified by CH and CRF, and measured together with IOPcc, precisely reveal glaucoma staging in TAO and thus are reliable for diagnosing and follow-up in clinical practice.


  • Open Access

    Axial Length of the Eyeball Is Important in Secondary Dislocation of the Intraocular Lens, Capsular Bag, and Capsular Tension Ring Complex

    by Anna Klysik, Katarzyna Kaszuba-Bartkowiak, Piotr Jurowski

    Purpose. To analyze the patients with secondary dislocation of CTR and IOL within 5 years from cataract surgery, to determine predisposing factors.Methods. 16 eyes of 15 patients aged66.2±6.7(from 49 to 82) with CTR/IOL complex dislocation within 5 years from cataract surgery were compared with 26 patients aged67.1±7.2(from 53 to 85), implanted with CTR during cataract surgery to manage zonule dehiscence and did not dislocate for at least 5 years, in respect of cause, axial length and IOL power, refraction, coexistent pathology, and trauma.Results. Axial length of the eyeball was23.8±1.3(from 21 to 29) in the group of patients with CTR/IOL dislocation and20.7±1.2(from 19 to 24) in patients with no dislocation present (p=0.008). Crystalline lens dislocation was diagnosed before surgery in 13 of 16 patients with CTR/IOL complex dislocation as opposed to 7 of 26 eyes in the control group (p=0.01). Pseudoexfoliation was present in 50% and 58% in both groups, respectively. Traumatic dislocation was present in 8 patients, none of them with CTR/IOL dislocation (p=0.04).Conclusion. Longer axial length may contribute to the failure of the CTR to prevent in-the-bag IOL dislocation. Traumatic dislocation appears to be well fixed with the CTR.


  • Blood–aqueous barrier integrity in patients with Graves’ ophthalmopathy (GO), before and after rehabilitative surgery

    by A Kłysik, M Kozakiewicz

    The study was conducted to analyze aqueous flare and its correlations in patients with Graves' ophthalmopathy (GO) undergoing orbital decompression, extraocular muscle, and eyelid surgery. Prospective interventional case series. Forty-eight eyes of 27 patients (20 female and 7 male, aged 54.4 ± 5.7) undergoing surgical treatment for GO. Eighteen eyes of nine patients (aged 55.3 ± 3.6) undergoing orbital decompression. Nineteen eyes of 11 patients (aged 54.7 ± 5.6) undergoing extraocular muscle surgery and 13 eyes of 7 patients (aged 53.9 ± 4.9) undergoing eyelid surgery and control group (34 patients aged 53.9 ± 5.1). Laser flare analysis and clinical assessment were performed before surgery and at 1 day, 7 days, and 3 months following surgery. Aqueous flare was significantly higher in patients with GO (14.03 ± 8.45) before intervention than in the control group (7.89 ± 3.56) (P<0.001), and correlated with Clinical Activity Score and intraocular pressure. In the patients undergoing orbital decompression, flare increased from 17.77 ± 10.63 pc/ms to 38.32 ± 13.56 pc/ms on the first day and 41.31 ± 17.19 pc/ms on the seventh day and returned to 16.01 ± 8.58 pc/ms in 3 months. In patients undergoing extraocular muscle surgery flare increased from 13.05 ± 6.50 to 23.04 ± 11.53 pc/ms (P<0.001) on the first day and returned to 18.02 ± 14.09 pc/ms on the seventh day. Eyelid surgery did not change flare values. Orbital decompression disrupts blood-aqueous barrier (BAB). The integrity of BAB returns to preoperative status within 3 months. Extraocular muscle surgery mildly affects BAB integrity, and the effect subsides within 7 days. Eyelid surgery does not affect BAB.


    • 1 January 2014
      • Vol. 116  (2) , 89-93

    Latanoprost is effective in reducing high intraocular pressure associated with Graves' ophthalmopathy.

    by Magdalena Gumińska, Anna Kłysik, Agnieszka Siejka, Piotr Jurowski

    To assess the efficacy and tolerability of latanoprost in the treatment of glaucoma and ocular hypertension associated with Graves' ophthalmopathy. Prospective interventional case series. 28 patients (19 females and 9 males) aged from 31 to 68 (mean age 45.5 +/- 5.6), presenting with diagnosis of Graves' ophthalmopathy and intraocular pressure equal to 25.0 mmHg or more. 18 Patients presented with inflammatory stage of Graves' ophthalmopathy. 22 patients were within the first two years from the onset of symptoms of Graves' ophthalmopathy. 6 patients had exophthalmos and history of active Graves' ophthalmopathy. Intraocular pressure was measured before treatment, and at two, four and six weeks of treatment with latanoprost at 9 am. Ocular symptoms and signs were noted before and after the treatment period. The mean baseline intraocular pressure was 26.6 +/- 2.5 mmHg, ranging from 25.0 mmHg to 42 mmHg. In two weeks of treatment, the mean intraocular pressure was 18.6 +/- 2.3 mmHg (min 12.0 mmHg, max 27.0 mmHg). At 4 weeks mean intraocular pressure was 18.4 +/- 2.2 mmHg (min 11.0 mmHg, max 28.0 mmHg). At 6 weeks mean intraocular pressure was 18.7 +/- 1.9 mmHg (ranging from 11 mmHg to 25.0 mmHg). 3 patients experienced mild side effects. Latanoprost is effective and well tolerated in the treatment of increased intraocular pressure associated with Graves' ophthalmopathy.


  • Sub‐Tenon injection of 2% lidocaine prevents intra‐operative floppy iris syndrome (IFIS) in male patients taking oral α‐adrenergic antagonists

    by Anna Klysik, Dorota Korzycka

    : Purpose: To compare 2% sub‐Tenon and 1% intra‐cameral lidocaine for cataract surgery in relation to the incidence and severity of IFIS. Prospective randomized clinical study.Methods: From 81 eligible, we included 71 men aged from 59 to 90 years (mean 76.5 ± 6.8) undergoing routine cataract surgery and taking oral α‐adrenergic antagonists, for urological reasons, for more than 1 year. Following randomization 34 men, aged from 62 to 90 years (mean 77.4 ± 8.1) received sub‐Tenon injection of 2.5 ml of 2% lidocaine and the remaining 37 men aged from 59 to 89 years (mean 75.2 ± 7.2) received 1% preservative free intra‐cameral lidocaine. Outcome measures were the incidence of IFIS, severity of intra‐operative pupillary constriction and iris prolapse.Results: Intra‐operative floppy iris syndrome (IFIS) was noted in 3 of 34 patients (8.8%) receiving sub‐Tenon lidocaine and in 18 of 37 patients (48.6%) receiving intra‐cameral lidocaine (p = 0.00). Severe IFIS was observed only in 3 of 37 patients (8.1%) receiving intra‐cameral lidocaine. Pupil diameter at the end of surgery was 4.37 ± 1.07 mm in the sub‐Tenon lidocaine group and 4.02 ± 1.06 mm in the intra‐cameral lidocaine group (p = 0.00). Iris prolapse was noted in two cases in the sub‐Tenon lidocaine group and in 10 cases in the intra‐cameral lidocaine group (p = 0.00). Twenty‐five patients were receiving tamsulosin. The incidence of IFIS in tamsulosin subgroup was 76.9% (10 of 13 patients) in the intra‐cameral lidocaine group and 16.6% (2 of 12 patients) in the sub‐Tenon lidocaine group (p = 0.00).Conclusion: Sub‐Tenon lidocaine reduces significantly the incidence of IFIS in patients taking oral α‐adrenergic inhibitors as compared with intra‐cameral lidocaine.


  • Open Access

    Clinical research Intraocular matrix metalloproteinase 2 and 9 in patients with diabetes mellitus with and without diabetic retinopathy

    by Anna B. Kłysik, Julia Naduk-Kik, Zbigniew Hrabec, Roman Goś, Elżbieta Hrabec

    Introduction: We aimed to investigate activities of metalloproteinases 2 (MMP-2) and MMP-9 in aqueous humour of patients with diabetes mellitus with various stages of diabetic retinopathy. Material and methods: We included 36 samples of aqueous humour of patients suffering from diabetes...