John M. Begovich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
John M. Begovich has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
W. G. Sisson
Chemical Technology Division Oak Ridge National Laboratory Oak Ridge, TN 37830
2 shared publicationsWarren G. Sisson
CHEMICAL TECHNOLOGY DIVISION OAK RIDGE NATIONAL LABORATORY , P. O. BOX X, OAK RIDGE , TENNESSEE , 37830
2 shared publicationsA.D. Ryon
1 shared publicationA.L. Lotts
1 shared publicationAllen D. Ryon
1 shared publicationAna Claudia Raffo-Caiado
ORNL
1 shared publication
Latest Publications
- 1 November 2009
- Published by Office of Scientific and Technical Information (OSTI)
Model of a Generic Natural Uranium Conversion Plant ? Suggested Measures to Strengthen International Safeguards
This is the final report that closed a joint collaboration effort between DOE and the National Nuclear Energy Commission of Brazil (CNEN). In 2005, DOE and CNEN started a collaborative effort to evaluate measures that can strengthen the effectiveness of international safeguards at a natural uranium conversion plant (NUCP). The work was performed by DOE s Oak Ridge National Laboratory and CNEN. A generic model of a NUCP was developed and typical processing steps were defined. Advanced instrumentation and techniques for verification purposes were identified and investigated. The scope of the work was triggered by the International Atomic Energy Agency s 2003 revised policy concerning the starting point of safeguards at uranium conversion facilities. Prior to this policy only the final products of the uranium conversion plant were considered to be of composition and purity suitable for use in the nuclear fuel cycle and therefore, subject to the IAEA safeguards control. DOE and CNEN have explored options for implementing the IAEA policy, although Brazil understands that the new policy established by the IAEA is beyond the framework of the Quadripartite Agreement of which it is one of the parties, together with Argentina, the Brazilian-Argentine Agency for Accounting and Control ofmore » Nuclear Materials (ABACC) and the IAEA. Two technical papers on this subject were published at the 2005 and 2008 INMM Annual Meetings.« less
- 1 November 2009
- Published by Office of Scientific and Technical Information (OSTI)
Model of a Generic Natural Uranium Conversion Plant ? Suggested Measures to Strengthen International Safeguards
This is the final report that closed a joint collaboration effort between DOE and the National Nuclear Energy Commission of Brazil (CNEN). In 2005, DOE and CNEN started a collaborative effort to evaluate measures that can strengthen the effectiveness of international safeguards at a natural uranium conversion plant (NUCP). The work was performed by DOE s Oak Ridge National Laboratory and CNEN. A generic model of a NUCP was developed and typical processing steps were defined. Advanced instrumentation and techniques for verification purposes were identified and investigated. The scope of the work was triggered by the International Atomic Energy Agency s 2003 revised policy concerning the starting point of safeguards at uranium conversion facilities. Prior to this policy only the final products of the uranium conversion plant were considered to be of composition and purity suitable for use in the nuclear fuel cycle and therefore, subject to the IAEA safeguards control. DOE and CNEN have explored options for implementing the IAEA policy, although Brazil understands that the new policy established by the IAEA is beyond the framework of the Quadripartite Agreement of which it is one of the parties, together with Argentina, the Brazilian-Argentine Agency for Accounting and Control ofmore » Nuclear Materials (ABACC) and the IAEA. Two technical papers on this subject were published at the 2005 and 2008 INMM Annual Meetings.« less
- 15 October 1992
- Published by Office of Scientific and Technical Information (OSTI)
HFIR spent fuel management alternatives
The High Flux Isotope Reactor (HFIR) at Martin Marietta Energy Systems' Oak Ridge National Laboratory (ORNL) has been unable to ship its spent fuel to Savannah River Site (SRS) for reprocessing since 1985. The HFIR storage pools are expected to fill up in the February 1994 to February 1995 time frame. If a management altemative to existing HFIR pool storage is not identified and implemented before the HFIR pools are full, the HFIR will be forced to shut down. This study investigated several alternatives for managing the HFIR spent fuel, attempting to identify options that could be implemented before the HFIR pools are full. The options investigated were: installing a dedicated dry cask storage facility at ORNL, increasing HFIR pool storage capacity by clearing the HFIR pools of debris and either close-packing or stacking the spent fuel elements, storing the spent fuel at another ORNL pool, storing the spent fuel in one or more hot cells at ORNL, and shipping the spent fuel offsite for reprocessing or storage elsewhere.
- 15 October 1992
- Published by Office of Scientific and Technical Information (OSTI)
HFIR spent fuel management alternatives
The High Flux Isotope Reactor (HFIR) at Martin Marietta Energy Systems' Oak Ridge National Laboratory (ORNL) has been unable to ship its spent fuel to Savannah River Site (SRS) for reprocessing since 1985. The HFIR storage pools are expected to fill up in the February 1994 to February 1995 time frame. If a management altemative to existing HFIR pool storage is not identified and implemented before the HFIR pools are full, the HFIR will be forced to shut down. This study investigated several alternatives for managing the HFIR spent fuel, attempting to identify options that could be implemented before the HFIR pools are full. The options investigated were: installing a dedicated dry cask storage facility at ORNL, increasing HFIR pool storage capacity by clearing the HFIR pools of debris and either close-packing or stacking the spent fuel elements, storing the spent fuel at another ORNL pool, storing the spent fuel in one or more hot cells at ORNL, and shipping the spent fuel offsite for reprocessing or storage elsewhere.
- 1 March 1991
- Published by Office of Scientific and Technical Information (OSTI)
Treatment studies at the Process Waste Treatment Plant at Oak Ridge National Laboratory
Precipitation and ion-exchange methods are being developed to decontaminate Oak Ridge National Laboratory process wastewaters containing small amounts of {sup 90}Sr and {sup 137}Cs while minimizing waste generation. Many potential processes have been examined in laboratory-scale screening tests. Based on these data, five process flowsheets were developed and are being evaluated under pilot- and full-scale operating conditions. Improvements in the existing treatment system based on this study have resulted in a 66 vol % reduction in waste generation. 19 refs., 26 figs., 45 tabs.
- 1 March 1991
- Published by Office of Scientific and Technical Information (OSTI)
Treatment studies at the Process Waste Treatment Plant at Oak Ridge National Laboratory
Precipitation and ion-exchange methods are being developed to decontaminate Oak Ridge National Laboratory process wastewaters containing small amounts of {sup 90}Sr and {sup 137}Cs while minimizing waste generation. Many potential processes have been examined in laboratory-scale screening tests. Based on these data, five process flowsheets were developed and are being evaluated under pilot- and full-scale operating conditions. Improvements in the existing treatment system based on this study have resulted in a 66 vol % reduction in waste generation. 19 refs., 26 figs., 45 tabs.
- 1 September 1984
- Published by Wiley in AIChE Journal
- Vol. 30 (5) , 705-710
A rotating annular chromatograph for continuous separations
Preparative, multicomponent liquid chromatographic separations have been achieved by using a slowly rotating annular sorbent bed with fixed multiple feed points and fixed product withdrawal locations. The cation exchange separation of copper, nickel, and two cobalt complexes has been extensively used to study the effects of rotation rate, eluent rate, bed loading, and column size on separation performance. Experimental results have been compared with three theoretical models: plate theory, an analytical solution which incorporates multicomponent Langmuir isotherms, and an extension of the analytical solution to include dispersion effects.
- 1 September 1984
- Published by Wiley in AIChE Journal
- Vol. 30 (5) , 705-710
A rotating annular chromatograph for continuous separations
Preparative, multicomponent liquid chromatographic separations have been achieved by using a slowly rotating annular sorbent bed with fixed multiple feed points and fixed product withdrawal locations. The cation exchange separation of copper, nickel, and two cobalt complexes has been extensively used to study the effects of rotation rate, eluent rate, bed loading, and column size on separation performance. Experimental results have been compared with three theoretical models: plate theory, an analytical solution which incorporates multicomponent Langmuir isotherms, and an extension of the analytical solution to include dispersion effects.
- 1 September 1983
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 18 (12-13) , 1167-1191
A High-Capacity Pressurized Continuous Chromatograph
Multicomponent liquid chromatographic separations have been achieved by using a slowly rotating annular bed of sorbent material. The feed material is continuously introduced at a stationary point at the top of the bed, and eluent is allowed to flow everywhere else around the annulus. The rotation of the sorbent bed causes the separated components to appear as helical bands, each of which has a characteristic, stationary exit point; hence the separation process is truly continuous. The concept has been developed primarily on a 279-mm-diam by 0.6-m-long device with a 12.7-mm-wide annulus. The effects of annulus width and diameter have been studied using the same device with annulus widths up to 114.3 mm. With this largest width, approximately 96% of the area available within the outer cylinder is devoted to the rotating sorbent bed. Further annulus-width studies have been pursued on units with 89- and 445-mm diameters. These geometric extensions to the basic concept allow extremely large capacity increases with minimal loss in separation and no increase in chromatograph diameter. The effects associated with increased feed concentration have also been studied. In this effort as well as in the annulus-width program, the separation of copper, nickel, and cobalt components from a carbonate solution was studied in detail. The nickel and cobalt components are found in the leach liquor of the Caron process for recovering nickel and cobalt from laterite ores. Nominally 50-μm-diam Dowex 50W-X8 cation exchange resin was used
- 1 September 1983
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 18 (12-13) , 1167-1191
A High-Capacity Pressurized Continuous Chromatograph
Multicomponent liquid chromatographic separations have been achieved by using a slowly rotating annular bed of sorbent material. The feed material is continuously introduced at a stationary point at the top of the bed, and eluent is allowed to flow everywhere else around the annulus. The rotation of the sorbent bed causes the separated components to appear as helical bands, each of which has a characteristic, stationary exit point; hence the separation process is truly continuous. The concept has been developed primarily on a 279-mm-diam by 0.6-m-long device with a 12.7-mm-wide annulus. The effects of annulus width and diameter have been studied using the same device with annulus widths up to 114.3 mm. With this largest width, approximately 96% of the area available within the outer cylinder is devoted to the rotating sorbent bed. Further annulus-width studies have been pursued on units with 89- and 445-mm diameters. These geometric extensions to the basic concept allow extremely large capacity increases with minimal loss in separation and no increase in chromatograph diameter. The effects associated with increased feed concentration have also been studied. In this effort as well as in the annulus-width program, the separation of copper, nickel, and cobalt components from a carbonate solution was studied in detail. The nickel and cobalt components are found in the leach liquor of the Caron process for recovering nickel and cobalt from laterite ores. Nominally 50-μm-diam Dowex 50W-X8 cation exchange resin was used
- 1 March 1983
- Published by Elsevier in Hydrometallurgy
- Vol. 10 (1) , 11-20
Continuous ion exchange separation of zirconium and hafnium using an annular chromatograph
- 1 March 1983
- Published by Elsevier in Hydrometallurgy
- Vol. 10 (1) , 11-20
Continuous ion exchange separation of zirconium and hafnium using an annular chromatograph
- 31 August 1982
- Published by Elsevier in Resources and Conservation
- Vol. 9, 219-229
A rotating annular chromatograph for continuous metal separations and recovery
- 31 August 1982
- Published by Elsevier in Resources and Conservation
- Vol. 9, 219-229
A rotating annular chromatograph for continuous metal separations and recovery
- 1 December 1980
- Published by Office of Scientific and Technical Information (OSTI)
Mathematical model for multicomponent separations on the continuous annular chromatograph
A model for multicomponent separations on ion exchange columns has been adapted for use in studying the performance of the continuous annular chromatograph. The model accurately predicts solute peak positions in the column effluent and qualitatively predicts trends in solute effluent resolution as a function of increasing bandwidth of the solute feed pulse. The major virtues of the model are its simplicity in terms of the calculations involved and the fact that it incorporates the nonlinear solute-resin binding isotherms common in many ion exchange separations. Because dispersion effects are not accounted for in the model, discrepancies exist between the shapes of the effluent peaks predicted by the model and those determined experimentally.
- 1 December 1980
- Published by Office of Scientific and Technical Information (OSTI)
Mathematical model for multicomponent separations on the continuous annular chromatograph
A model for multicomponent separations on ion exchange columns has been adapted for use in studying the performance of the continuous annular chromatograph. The model accurately predicts solute peak positions in the column effluent and qualitatively predicts trends in solute effluent resolution as a function of increasing bandwidth of the solute feed pulse. The major virtues of the model are its simplicity in terms of the calculations involved and the fact that it incorporates the nonlinear solute-resin binding isotherms common in many ion exchange separations. Because dispersion effects are not accounted for in the model, discrepancies exist between the shapes of the effluent peaks predicted by the model and those determined experimentally.
- 1 September 1980
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Product Research and Development
- Vol. 19 (3) , 459-467
Chemical Flowsheet Conditions for Preparing Urania Spheres by Internal Gelation
- 1 September 1980
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Product Research and Development
- Vol. 19 (3) , 459-467
Chemical Flowsheet Conditions for Preparing Urania Spheres by Internal Gelation
- 1 April 1980
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 15 (3) , 655-678
Pressurized Continuous Chromatography
A pressurized continuous annular chromatograph has been developed for preparative separations. This device utilizes a slowly rotating annular bed of sorbent material, fixed multiple feed points, and fixed withdrawal locations. Most of our investigations have been performed with a 28-cm-diam column, but a larger model is being designed and constructed. The separation of copper, nickel, and cobalt components from a carbonate solution has been studied in detail. This solution simulates the leach liquor from the Caron process for recovering nickel and cobalt from laterite ores. Use of continuous gradient elution has been demonstrated. Recent studies have investigated several separations, including that of zirconium and hafnium (necessary for the production of zirconium for use in nuclear reactors), on a preparative scale. This system, because of its continuous feed and product withdrawal, its adaptability to large-scale operations, and its ability to separate many components, is expected to make chromatography a more competitive process in the industrial sector.
- 1 April 1980
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 15 (3) , 655-678
Pressurized Continuous Chromatography
A pressurized continuous annular chromatograph has been developed for preparative separations. This device utilizes a slowly rotating annular bed of sorbent material, fixed multiple feed points, and fixed withdrawal locations. Most of our investigations have been performed with a 28-cm-diam column, but a larger model is being designed and constructed. The separation of copper, nickel, and cobalt components from a carbonate solution has been studied in detail. This solution simulates the leach liquor from the Caron process for recovering nickel and cobalt from laterite ores. Use of continuous gradient elution has been demonstrated. Recent studies have investigated several separations, including that of zirconium and hafnium (necessary for the production of zirconium for use in nuclear reactors), on a preparative scale. This system, because of its continuous feed and product withdrawal, its adaptability to large-scale operations, and its ability to separate many components, is expected to make chromatography a more competitive process in the industrial sector.