Dirk Schädler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dirk Schädler has a total of 281 co-authors. Here are the top co-authors by number of shared publications:
- Inéz Frerichs
University Hospital Schleswig-Holstein
31 shared publications Norbert Weiler
Department of Anesthesiology and Intensive Care Medicine University Medical Center Schleswig‐Holstein Campus Kiel Kiel Germany
21 shared publications- Tobias Becher
Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
18 shared publications Gunnar Elke
Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
8 shared publicationsGünther Zick
Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Arnold-Heller-Straße 3, Haus 12, 24105, Kiel, Germany
8 shared publicationsJens Scholz
University Medical Center Schleswig-Holstein
7 shared publications
Latest Publications
- Open Access
- 21 July 2026
- Published by Springer Nature in Research Square
Predicting global and regional respiratory response in ARDS patients through individualized physics-based computational lung models: A prospective clinical pilot study
Background Lung-protective ventilation is essential in the management of acute respiratory distress syndrome (ARDS), but current approaches are limited by the heterogeneity of lung pathology and a lack of individualized strategies. Patient-specific computational models may overcome these limitations by providing predictive and physiologically interpretable insights into global and regional lung behavior. Methods Ten mechanically ventilated patients with ARDS were evaluated in a monocentric prospective pilot study. A predefined study protocol included ventilatory maneuvers with systematic changes in ventilator mode, tidal volume, positive end-expiratory pressure (PEEP), and driving pressure. For each patient, a personalized, regionally resolved physics-based computational lung model was generated and calibrated to reproduce the individual respiratory system mechanics. Model predictions of tidal volume, airway and transpulmonary pressures, end-expiratory lung volume (EELV), and electrical impedance tomography (EIT)-derived regional ventilation distribution were simulated for different PEEP levels and evaluated against clinically assessed reference values. Model predictions were compared to clinical data using Pearson correlation coefficients (r), root mean square error (RMSE), and Bland–Altman analyses. Results A strong agreement was observed between simulated and clinical data for tidal volumes (r = 0.925, p < 0.001, RMSE = 0.053 l) and driving pressures (r = 0.940, p < 0.001, RMSE = 1.328 mbar) across all PEEP levels. At initial PEEP level, we found a high image correlation (r > 0.8) was found between measured and simulated regional ventilation in five of seven patients where EIT data were available. Conclusions This pilot study demonstrates the capability of the individualized, regionally resolved physics-based computational lung model to reproduce patient-specific respiratory mechanics and key features of regional ventilation patterns in ARDS. The strong agreement between simulated and measured data supports the potential of this approach to estimate the physiological response to ventilator adjustments and lays the groundwork for future studies integrating computational modeling into clinical decision-making. Trial registration: Registered at the German Clinical Trials Register (DRKS00017151, https://drks.de/search/en/trial/DRKS00017151) at 12th April 2019
- 21 July 2026
- Published by Springer Nature in Research Square
Open AccessPredicting global and regional respiratory response in ARDS patients through individualized physics-based computational lung models: A prospective clinical pilot study
Background Lung-protective ventilation is essential in the management of acute respiratory distress syndrome (ARDS), but current approaches are limited by the heterogeneity of lung pathology and a lack of individualized strategies. Patient-specific computational models may overcome these limitations by providing predictive and physiologically interpretable insights into global and regional lung behavior. Methods Ten mechanically ventilated patients with ARDS were evaluated in a monocentric prospective pilot study. A predefined study protocol included ventilatory maneuvers with systematic changes in ventilator mode, tidal volume, positive end-expiratory pressure (PEEP), and driving pressure. For each patient, a personalized, regionally resolved physics-based computational lung model was generated and calibrated to reproduce the individual respiratory system mechanics. Model predictions of tidal volume, airway and transpulmonary pressures, end-expiratory lung volume (EELV), and electrical impedance tomography (EIT)-derived regional ventilation distribution were simulated for different PEEP levels and evaluated against clinically assessed reference values. Model predictions were compared to clinical data using Pearson correlation coefficients (r), root mean square error (RMSE), and Bland–Altman analyses. Results A strong agreement was observed between simulated and clinical data for tidal volumes (r = 0.925, p < 0.001, RMSE = 0.053 l) and driving pressures (r = 0.940, p < 0.001, RMSE = 1.328 mbar) across all PEEP levels. At initial PEEP level, we found a high image correlation (r > 0.8) was found between measured and simulated regional ventilation in five of seven patients where EIT data were available. Conclusions This pilot study demonstrates the capability of the individualized, regionally resolved physics-based computational lung model to reproduce patient-specific respiratory mechanics and key features of regional ventilation patterns in ARDS. The strong agreement between simulated and measured data supports the potential of this approach to estimate the physiological response to ventilator adjustments and lays the groundwork for future studies integrating computational modeling into clinical decision-making. Trial registration: Registered at the German Clinical Trials Register (DRKS00017151, https://drks.de/search/en/trial/DRKS00017151) at 12th April 2019
- Open Access
- 19 March 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 280, 109329
Patient-ventilator interaction—Development of a mathematical model of the respiratory center
- 19 March 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 280, 109329
Open AccessPatient-ventilator interaction—Development of a mathematical model of the respiratory center
- Top Cited Papers
- 1 November 2025
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 211 (11) , 2169-2179
Increased Driving Pressure During Assisted Ventilation for Hypoxemic Respiratory Failure Is Associated with Lower ICU Survival: The ICEBERG Study
Rationale: Driving pressure (ΔP) is a marker of severity and a possible target for lung protection during controlled ventilation, but its value during assisted ventilation is unknown. Inspiratory holds provide an estimate of ΔP that is quasi-static. Expiratory holds provide an estimate of the inspiratory effort, which is useful to estimate the transpulmonary dynamic ΔP. Objectives: To assess the correlation between ΔPs measured during assisted ventilation and ICU outcomes. Methods: Multicenter prospective observational study. Patients with acute hypoxemic respiratory failure were enrolled within 48 hours of triggering the ventilator. Respiratory mechanics were measured daily, and the variables of interest were averaged over the first 3 days of partial assistance. ICU outcomes were collected until Day 90. Measurements and Main Results: A total of 298 patients from 16 centers were enrolled. Vt, peak airway pressure, positive end-expiratory pressure, and inspiratory effort during the first 3 days of assisted ventilation did not differ between survivors and nonsurvivors. Quasi-static ΔP and transpulmonary dynamic ΔP were higher in nonsurvivors than in survivors (13 [IQR, 11–14] vs. 11 [9–13] cm H2O [P < 0.001]; and 19 [16–23] vs. 16 [13–18] cm H2O [P < 0.001], respectively), whereas compliance normalized to predicted body weight was lower (0.65 [0.54–0.84] vs. 0.79 [0.64–0.97] mL/cm H2O/kg; P < 0.001). Multivariable analysis confirmed the association with outcomes. During the study days, static ΔP significantly diverged between survivors and nonsurvivors. Conclusions: During assisted ventilation, ΔP and normalized compliance are associated with ICU outcome, despite some overlap. Although our study does not allow an estimation of whether ΔP is a marker of severity or a cause of lung injury, it highlights the potential value of monitoring and targeting it during spontaneous assisted breathing.
- 1 November 2025
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 211 (11) , 2169-2179
Top Cited PapersIncreased Driving Pressure During Assisted Ventilation for Hypoxemic Respiratory Failure Is Associated with Lower ICU Survival: The ICEBERG Study
Rationale: Driving pressure (ΔP) is a marker of severity and a possible target for lung protection during controlled ventilation, but its value during assisted ventilation is unknown. Inspiratory holds provide an estimate of ΔP that is quasi-static. Expiratory holds provide an estimate of the inspiratory effort, which is useful to estimate the transpulmonary dynamic ΔP. Objectives: To assess the correlation between ΔPs measured during assisted ventilation and ICU outcomes. Methods: Multicenter prospective observational study. Patients with acute hypoxemic respiratory failure were enrolled within 48 hours of triggering the ventilator. Respiratory mechanics were measured daily, and the variables of interest were averaged over the first 3 days of partial assistance. ICU outcomes were collected until Day 90. Measurements and Main Results: A total of 298 patients from 16 centers were enrolled. Vt, peak airway pressure, positive end-expiratory pressure, and inspiratory effort during the first 3 days of assisted ventilation did not differ between survivors and nonsurvivors. Quasi-static ΔP and transpulmonary dynamic ΔP were higher in nonsurvivors than in survivors (13 [IQR, 11–14] vs. 11 [9–13] cm H2O [P < 0.001]; and 19 [16–23] vs. 16 [13–18] cm H2O [P < 0.001], respectively), whereas compliance normalized to predicted body weight was lower (0.65 [0.54–0.84] vs. 0.79 [0.64–0.97] mL/cm H2O/kg; P < 0.001). Multivariable analysis confirmed the association with outcomes. During the study days, static ΔP significantly diverged between survivors and nonsurvivors. Conclusions: During assisted ventilation, ΔP and normalized compliance are associated with ICU outcome, despite some overlap. Although our study does not allow an estimation of whether ΔP is a marker of severity or a cause of lung injury, it highlights the potential value of monitoring and targeting it during spontaneous assisted breathing.
- 1 October 2025
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 139 (4) , 1029-1049
Patient-specific prediction of regional lung mechanics in patients with ARDS with physics-based models: a validation study
This study presents the first systematic validation of physics-based, patient-specific computational lung models for mechanically ventilated patients. By comparing model-predicted regional ventilation with bedside electrical impedance tomography, we demonstrate the ability of our computational approach to predict regional lung mechanics and patient-specific phenomena. Embedded within a computational pipeline fast enough for clinical workflows, this marks a significant step toward truly personalized, model-informed ventilation management in the ICU.
- 1 October 2025
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 139 (4) , 1029-1049
Patient-specific prediction of regional lung mechanics in patients with ARDS with physics-based models: a validation study
This study presents the first systematic validation of physics-based, patient-specific computational lung models for mechanically ventilated patients. By comparing model-predicted regional ventilation with bedside electrical impedance tomography, we demonstrate the ability of our computational approach to predict regional lung mechanics and patient-specific phenomena. Embedded within a computational pipeline fast enough for clinical workflows, this marks a significant step toward truly personalized, model-informed ventilation management in the ICU.
- Open Access
- 26 September 2025
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 27, e77077
Computer-Interpretable Quality Indicators for Intensive Care Medicine: Development and Validation Study
Background: Quality indicators (QIs) can help assess intensive care quality, identify potential for improvement, and ultimately enhance patient outcomes. Therefore, the German Interdisciplinary Association of Critical Care and Emergency Medicine (DIVI) has developed QIs for intensive care medicine. However, variability in how these are technically implemented across health care facilities currently limits their comparability. Objective: The aim of the study is to develop unambiguous computer-interpretable representations of the DIVI QIs for intensive care medicine using Fast Healthcare Interoperability Resources (FHIR) and to establish a replicable process for translating narrative QIs into standardized digital formats. Methods: We first decomposed the narrative DIVI intensive care medicine QIs into two sets of semantic concepts that characterize (1) the targeted patient population and (2) the care aspect specified by each indicator. We mapped the concepts to international vocabularies, defining a supplementary code system for concepts not appropriately represented in existing vocabularies. The decomposed and semantically mapped QIs were then implemented in FHIR using an implementation guide we previously developed to represent clinical practice guideline recommendations. As the translation process holds risks of inducing logical and semantic deviations, the final FHIR representations were back-translated into a narrative form and reviewed with clinical experts, including the authors of the original QIs. The decomposition and semantic mapping were iteratively adjusted based on the experts’ feedback until the results accurately reflected the original intent of the QIs. Results: The 10 DIVI QIs were decomposed into 31 separately measurable indicators, including 9 structural indicators, 17 process indicators, and 5 outcome indicators. All process and outcome indicators were successfully specified as computer-interpretable representations in FHIR. In total, 58 unique medical concepts were used, of which 52 (90%) could be mapped to concepts from international vocabularies. The remaining 6 concepts—mostly intensive care unit–specific scores or roles—were defined in a supplementary code system. Nested Boolean logic and temporal conditions were fully supported using standard FHIR mechanisms. After iterative adjustments, the final representations were approved as accurate representations of the DIVI QIs by the clinical expert panel. Conclusions: Our work demonstrates that the structured process developed here enables the unambiguous, computer-interpretable representation of QIs for intensive care. These representations can be used in automated quality management systems to standardize quality assessments across health care facilities. Our newly defined structured process can serve as a blueprint for similar efforts in other specialties. The here-developed computer-interpretable QIs are openly available for reuse and ongoing maintenance. Future work will focus on piloting these indicators in real-world clinical systems and extending the framework to include structural indicators.
- 26 September 2025
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 27, e77077
Open AccessComputer-Interpretable Quality Indicators for Intensive Care Medicine: Development and Validation Study
Background: Quality indicators (QIs) can help assess intensive care quality, identify potential for improvement, and ultimately enhance patient outcomes. Therefore, the German Interdisciplinary Association of Critical Care and Emergency Medicine (DIVI) has developed QIs for intensive care medicine. However, variability in how these are technically implemented across health care facilities currently limits their comparability. Objective: The aim of the study is to develop unambiguous computer-interpretable representations of the DIVI QIs for intensive care medicine using Fast Healthcare Interoperability Resources (FHIR) and to establish a replicable process for translating narrative QIs into standardized digital formats. Methods: We first decomposed the narrative DIVI intensive care medicine QIs into two sets of semantic concepts that characterize (1) the targeted patient population and (2) the care aspect specified by each indicator. We mapped the concepts to international vocabularies, defining a supplementary code system for concepts not appropriately represented in existing vocabularies. The decomposed and semantically mapped QIs were then implemented in FHIR using an implementation guide we previously developed to represent clinical practice guideline recommendations. As the translation process holds risks of inducing logical and semantic deviations, the final FHIR representations were back-translated into a narrative form and reviewed with clinical experts, including the authors of the original QIs. The decomposition and semantic mapping were iteratively adjusted based on the experts’ feedback until the results accurately reflected the original intent of the QIs. Results: The 10 DIVI QIs were decomposed into 31 separately measurable indicators, including 9 structural indicators, 17 process indicators, and 5 outcome indicators. All process and outcome indicators were successfully specified as computer-interpretable representations in FHIR. In total, 58 unique medical concepts were used, of which 52 (90%) could be mapped to concepts from international vocabularies. The remaining 6 concepts—mostly intensive care unit–specific scores or roles—were defined in a supplementary code system. Nested Boolean logic and temporal conditions were fully supported using standard FHIR mechanisms. After iterative adjustments, the final representations were approved as accurate representations of the DIVI QIs by the clinical expert panel. Conclusions: Our work demonstrates that the structured process developed here enables the unambiguous, computer-interpretable representation of QIs for intensive care. These representations can be used in automated quality management systems to standardize quality assessments across health care facilities. Our newly defined structured process can serve as a blueprint for similar efforts in other specialties. The here-developed computer-interpretable QIs are openly available for reuse and ongoing maintenance. Future work will focus on piloting these indicators in real-world clinical systems and extending the framework to include structural indicators.
- Open Access
- 23 June 2025
- Published by Wiley in Anaesthesia
- Vol. 80 (11) , 1322-1332
Adjustment of positive end‐expiratory pressure based on body mass index during general anaesthesia: a randomised controlled trial*
Summary: Introduction: Lung‐protective ventilation is essential for preventing postoperative pulmonary complications. While maintaining a low driving pressure and optimising PEEP is of importance, the ideal strategy remains contentious. This study evaluated whether adjusting PEEP based on BMI, compared with standard PEEP, could reduce driving pressure and peri‐operative loss of lung aeration.Methods: We conducted a randomised controlled, patient‐blinded, single‐centre superiority trial with two parallel groups. Adult patients undergoing surgery with general anaesthesia who required tracheal intubation were assigned randomly to either standardised PEEP (PEEP = 5 cmH2O; group PEEP‐5) or PEEP set according to BMI (PEEP = BMI/3 cmH2O; group PEEP‐BMI/3). Patients' lungs were ventilated using a volume‐controlled mode with tidal volumes of 7 ml.kg‐1 predicted body weight. Lung aeration scores were assessed using ultrasound pre‐ and postoperatively.Results: Sixty patients were enrolled and allocated randomly. Adjustment of PEEP according to BMI/3 was associated with a significantly lower driving pressure, with a median (IQR [range]) of 8.9 (7.1–10.4 [5.2–14.9]) cmH2O in group PEEP‐5 and 7.9 (7.2–8.5 [5.9–14.1]) cmH2O in group PEEP‐BMI/3 (p = 0.027) and higher mean (SD) respiratory system compliance (group PEEP‐5, 0.83 (0.20) ml cmH2O‐1 kg‐1 predicted body weight vs. group PEEP‐BMI/3, 0.95 (0.17) ml cmH2O‐1 kg‐1 predicted body weight; p = 0.020). Lung ultrasound revealed a reduced postoperative loss of lung aeration in patients allocated to the BMI/3 group. Patients allocated to the BMI‐adjusted group required less supplemental oxygen, had less newly developed atelectasis and had higher oxygen saturations upon arrival in the post‐anaesthesia care unit.Discussion: In patients without major pulmonary disease who were undergoing non‐cardiothoracic surgeries with tracheal intubation, adjusting PEEP based on a calculation of BMI/3 improved lung mechanics and reduced postoperative loss of lung aeration. This approach provides a straightforward and pragmatic method for individualising PEEP in patients undergoing general anaesthesia.
- 23 June 2025
- Published by Wiley in Anaesthesia
- Vol. 80 (11) , 1322-1332
Open AccessAdjustment of positive end‐expiratory pressure based on body mass index during general anaesthesia: a randomised controlled trial*
Summary: Introduction: Lung‐protective ventilation is essential for preventing postoperative pulmonary complications. While maintaining a low driving pressure and optimising PEEP is of importance, the ideal strategy remains contentious. This study evaluated whether adjusting PEEP based on BMI, compared with standard PEEP, could reduce driving pressure and peri‐operative loss of lung aeration.Methods: We conducted a randomised controlled, patient‐blinded, single‐centre superiority trial with two parallel groups. Adult patients undergoing surgery with general anaesthesia who required tracheal intubation were assigned randomly to either standardised PEEP (PEEP = 5 cmH2O; group PEEP‐5) or PEEP set according to BMI (PEEP = BMI/3 cmH2O; group PEEP‐BMI/3). Patients' lungs were ventilated using a volume‐controlled mode with tidal volumes of 7 ml.kg‐1 predicted body weight. Lung aeration scores were assessed using ultrasound pre‐ and postoperatively.Results: Sixty patients were enrolled and allocated randomly. Adjustment of PEEP according to BMI/3 was associated with a significantly lower driving pressure, with a median (IQR [range]) of 8.9 (7.1–10.4 [5.2–14.9]) cmH2O in group PEEP‐5 and 7.9 (7.2–8.5 [5.9–14.1]) cmH2O in group PEEP‐BMI/3 (p = 0.027) and higher mean (SD) respiratory system compliance (group PEEP‐5, 0.83 (0.20) ml cmH2O‐1 kg‐1 predicted body weight vs. group PEEP‐BMI/3, 0.95 (0.17) ml cmH2O‐1 kg‐1 predicted body weight; p = 0.020). Lung ultrasound revealed a reduced postoperative loss of lung aeration in patients allocated to the BMI/3 group. Patients allocated to the BMI‐adjusted group required less supplemental oxygen, had less newly developed atelectasis and had higher oxygen saturations upon arrival in the post‐anaesthesia care unit.Discussion: In patients without major pulmonary disease who were undergoing non‐cardiothoracic surgeries with tracheal intubation, adjusting PEEP based on a calculation of BMI/3 improved lung mechanics and reduced postoperative loss of lung aeration. This approach provides a straightforward and pragmatic method for individualising PEEP in patients undergoing general anaesthesia.
- Open Access
- 7 May 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Computer-Interpretable Quality Indicators for Intensive Care Medicine: Development and Validation Study (Preprint)
BACKGROUND Quality indicators (QIs) can help assess intensive care quality, identify potential for improvement, and ultimately enhance patient outcomes. Therefore, the German Interdisciplinary Association of Critical Care and Emergency Medicine (DIVI) has developed QIs for intensive care medicine. However, variability in how these are technically implemented across health care facilities currently limits their comparability. OBJECTIVE The aim of the study is to develop unambiguous computer-interpretable representations of the DIVI QIs for intensive care medicine using Fast Healthcare Interoperability Resources (FHIR) and to establish a replicable process for translating narrative QIs into standardized digital formats. METHODS We first decomposed the narrative DIVI intensive care medicine QIs into two sets of semantic concepts that characterize (1) the targeted patient population and (2) the care aspect specified by each indicator. We mapped the concepts to international vocabularies, defining a supplementary code system for concepts not appropriately represented in existing vocabularies. The decomposed and semantically mapped QIs were then implemented in FHIR using an implementation guide we previously developed to represent clinical practice guideline recommendations. As the translation process holds risks of inducing logical and semantic deviations, the final FHIR representations were back-translated into a narrative form and reviewed with clinical experts, including the authors of the original QIs. The decomposition and semantic mapping were iteratively adjusted based on the experts’ feedback until the results accurately reflected the original intent of the QIs. RESULTS The 10 DIVI QIs were decomposed into 31 separately measurable indicators, including 9 structural indicators, 17 process indicators, and 5 outcome indicators. All process and outcome indicators were successfully specified as computer-interpretable representations in FHIR. In total, 58 unique medical concepts were used, of which 52 (90%) could be mapped to concepts from international vocabularies. The remaining 6 concepts—mostly intensive care unit–specific scores or roles—were defined in a supplementary code system. Nested Boolean logic and temporal conditions were fully supported using standard FHIR mechanisms. After iterative adjustments, the final representations were approved as accurate representations of the DIVI QIs by the clinical expert panel. CONCLUSIONS Our work demonstrates that the structured process developed here enables the unambiguous, computer-interpretable representation of QIs for intensive care. These representations can be used in automated quality management systems to standardize quality assessments across health care facilities. Our newly defined structured process can serve as a blueprint for similar efforts in other specialties. The here-developed computer-interpretable QIs are openly available for reuse and ongoing maintenance. Future work will focus on piloting these indicators in real-world clinical systems and extending the framework to include structural indicators.
- 7 May 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessComputer-Interpretable Quality Indicators for Intensive Care Medicine: Development and Validation Study (Preprint)
BACKGROUND Quality indicators (QIs) can help assess intensive care quality, identify potential for improvement, and ultimately enhance patient outcomes. Therefore, the German Interdisciplinary Association of Critical Care and Emergency Medicine (DIVI) has developed QIs for intensive care medicine. However, variability in how these are technically implemented across health care facilities currently limits their comparability. OBJECTIVE The aim of the study is to develop unambiguous computer-interpretable representations of the DIVI QIs for intensive care medicine using Fast Healthcare Interoperability Resources (FHIR) and to establish a replicable process for translating narrative QIs into standardized digital formats. METHODS We first decomposed the narrative DIVI intensive care medicine QIs into two sets of semantic concepts that characterize (1) the targeted patient population and (2) the care aspect specified by each indicator. We mapped the concepts to international vocabularies, defining a supplementary code system for concepts not appropriately represented in existing vocabularies. The decomposed and semantically mapped QIs were then implemented in FHIR using an implementation guide we previously developed to represent clinical practice guideline recommendations. As the translation process holds risks of inducing logical and semantic deviations, the final FHIR representations were back-translated into a narrative form and reviewed with clinical experts, including the authors of the original QIs. The decomposition and semantic mapping were iteratively adjusted based on the experts’ feedback until the results accurately reflected the original intent of the QIs. RESULTS The 10 DIVI QIs were decomposed into 31 separately measurable indicators, including 9 structural indicators, 17 process indicators, and 5 outcome indicators. All process and outcome indicators were successfully specified as computer-interpretable representations in FHIR. In total, 58 unique medical concepts were used, of which 52 (90%) could be mapped to concepts from international vocabularies. The remaining 6 concepts—mostly intensive care unit–specific scores or roles—were defined in a supplementary code system. Nested Boolean logic and temporal conditions were fully supported using standard FHIR mechanisms. After iterative adjustments, the final representations were approved as accurate representations of the DIVI QIs by the clinical expert panel. CONCLUSIONS Our work demonstrates that the structured process developed here enables the unambiguous, computer-interpretable representation of QIs for intensive care. These representations can be used in automated quality management systems to standardize quality assessments across health care facilities. Our newly defined structured process can serve as a blueprint for similar efforts in other specialties. The here-developed computer-interpretable QIs are openly available for reuse and ongoing maintenance. Future work will focus on piloting these indicators in real-world clinical systems and extending the framework to include structural indicators.
- Open Access
- 1 July 2024
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (7) , 075005
Sex differences in chest electrical impedance tomography findings
Objective. Electrical impedance tomography (EIT) has been used to determine regional lung ventilation distribution in humans for decades, however, the effect of biological sex on the findings has hardly ever been examined. The aim of our study was to determine if the spatial distribution of ventilation assessed by EIT during quiet breathing was influenced by biological sex. Approach. 219 adults with no known acute or chronic lung disease were examined in sitting position with the EIT electrodes placed around the lower chest (6th intercostal space). EIT data were recorded at 33 images/s during quiet breathing for 60 s. Regional tidal impedance variation was calculated in all EIT image pixels and the spatial distribution of the values was determined using the established EIT measures of centre of ventilation in ventrodorsal (CoVvd) and right-to-left direction (CoVrl), the dorsal and right fraction of ventilation, and ventilation defect score. Main results. After exclusion of one subject due to insufficient electrode contact, 218 data sets were analysed (120 men, 98 women) (age: 53 ± 18 vs 50 ± 16 yr (p = 0.2607), body mass index: 26.4 ± 4.0 vs 26.4 ± 6.6 kg m−2 (p = 0.9158), mean ± SD). Highly significant differences in ventilation distribution were identified between men and women between the right and left chest sides (CoVrl: 47.0 ± 2.9 vs 48.8 ± 3.3% of chest diameter (p < 0.0001), right fraction of ventilation: 0.573 ± 0.067 vs 0.539 ± 0.071 (p = 0.0004)) and less significant in the ventrodorsal direction (CoVvd: 55.6 ± 4.2 vs 54.5 ± 3.6% of chest diameter (p = 0.0364), dorsal fraction of ventilation: 0.650 ± 0.121 vs 0.625 ± 0.104 (p = 0.1155)). Ventilation defect score higher than one was found in 42.5% of men but only in 16.6% of women. Significance. Biological sex needs to be considered when EIT findings acquired in upright subjects in a rather caudal examination plane are interpreted. Sex differences in chest anatomy and thoracoabdominal mechanics may explain the results.
- 1 July 2024
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (7) , 075005
Open AccessSex differences in chest electrical impedance tomography findings
Objective. Electrical impedance tomography (EIT) has been used to determine regional lung ventilation distribution in humans for decades, however, the effect of biological sex on the findings has hardly ever been examined. The aim of our study was to determine if the spatial distribution of ventilation assessed by EIT during quiet breathing was influenced by biological sex. Approach. 219 adults with no known acute or chronic lung disease were examined in sitting position with the EIT electrodes placed around the lower chest (6th intercostal space). EIT data were recorded at 33 images/s during quiet breathing for 60 s. Regional tidal impedance variation was calculated in all EIT image pixels and the spatial distribution of the values was determined using the established EIT measures of centre of ventilation in ventrodorsal (CoVvd) and right-to-left direction (CoVrl), the dorsal and right fraction of ventilation, and ventilation defect score. Main results. After exclusion of one subject due to insufficient electrode contact, 218 data sets were analysed (120 men, 98 women) (age: 53 ± 18 vs 50 ± 16 yr (p = 0.2607), body mass index: 26.4 ± 4.0 vs 26.4 ± 6.6 kg m−2 (p = 0.9158), mean ± SD). Highly significant differences in ventilation distribution were identified between men and women between the right and left chest sides (CoVrl: 47.0 ± 2.9 vs 48.8 ± 3.3% of chest diameter (p < 0.0001), right fraction of ventilation: 0.573 ± 0.067 vs 0.539 ± 0.071 (p = 0.0004)) and less significant in the ventrodorsal direction (CoVvd: 55.6 ± 4.2 vs 54.5 ± 3.6% of chest diameter (p = 0.0364), dorsal fraction of ventilation: 0.650 ± 0.121 vs 0.625 ± 0.104 (p = 0.1155)). Ventilation defect score higher than one was found in 42.5% of men but only in 16.6% of women. Significance. Biological sex needs to be considered when EIT findings acquired in upright subjects in a rather caudal examination plane are interpreted. Sex differences in chest anatomy and thoracoabdominal mechanics may explain the results.
- Open Access
- 26 April 2024
- Published by Springer Nature in Trials
- Vol. 25 (1) , 1-11
Adjustment of positive end-expiratory pressure to body mass index during mechanical ventilation in general anesthesia: BodyVent, a randomized controlled trial
Background: In patients requiring general anesthesia, lung-protective ventilation can prevent postoperative pulmonary complications, which are associated with higher morbidity, mortality, and prolonged hospital stay. Application of positive end-expiratory pressure (PEEP) is one component of lung-protective ventilation. The correct strategy for setting adequate PEEP, however, remains controversial. PEEP settings that lead to a lower pressure difference between end-inspiratory plateau pressure and end-expiratory pressure (“driving pressure,” ΔP) may reduce the risk of postoperative pulmonary complications. Preliminary data suggests that the PEEP required to prevent both end-inspiratory overdistension and end-expiratory alveolar collapse, thereby reducing ΔP, correlates positively with the body mass index (BMI) of patients, with PEEP values corresponding to approximately 1/3 of patient’s respective BMI. Thus, we hypothesize that adjusting PEEP according to patient BMI reduces ΔP and may result in less postoperative pulmonary complications. Methods: Patients undergoing general anesthesia and endotracheal intubation with volume-controlled ventilation with a tidal volume of 7 ml per kg predicted body weight will be randomized and assigned to either an intervention group with PEEP adjusted according to BMI or a control group with a standardized PEEP of 5 mbar. Pre- and postoperatively, lung ultrasound will be performed to determine the lung aeration score, and hemodynamic and respiratory vital signs will be recorded for subsequent evaluation. The primary outcome is the difference in ΔP as a surrogate parameter for lung-protective ventilation. Secondary outcomes include change in lung aeration score, intraoperative occurrence of hemodynamic and respiratory events, oxygen requirements and postoperative pulmonary complications. Discussion: The study results will show whether an intraoperative ventilation strategy with PEEP adjustment based on BMI has the potential of reducing the risk for postoperative pulmonary complications as an easy-to-implement intervention that does not require lengthy ventilator maneuvers nor additional equipment. Trial registration: German Clinical Trials Register (DRKS), DRKS00031336. Registered 21st February 2023. Trial status: The study protocol was approved by the ethics committee of the Christian-Albrechts-Universität Kiel, Germany, on 1st February 2023. Recruitment began in March 2023 and is expected to end in September 2023.
- 26 April 2024
- Published by Springer Nature in Trials
- Vol. 25 (1) , 1-11
Open AccessAdjustment of positive end-expiratory pressure to body mass index during mechanical ventilation in general anesthesia: BodyVent, a randomized controlled trial
Background: In patients requiring general anesthesia, lung-protective ventilation can prevent postoperative pulmonary complications, which are associated with higher morbidity, mortality, and prolonged hospital stay. Application of positive end-expiratory pressure (PEEP) is one component of lung-protective ventilation. The correct strategy for setting adequate PEEP, however, remains controversial. PEEP settings that lead to a lower pressure difference between end-inspiratory plateau pressure and end-expiratory pressure (“driving pressure,” ΔP) may reduce the risk of postoperative pulmonary complications. Preliminary data suggests that the PEEP required to prevent both end-inspiratory overdistension and end-expiratory alveolar collapse, thereby reducing ΔP, correlates positively with the body mass index (BMI) of patients, with PEEP values corresponding to approximately 1/3 of patient’s respective BMI. Thus, we hypothesize that adjusting PEEP according to patient BMI reduces ΔP and may result in less postoperative pulmonary complications. Methods: Patients undergoing general anesthesia and endotracheal intubation with volume-controlled ventilation with a tidal volume of 7 ml per kg predicted body weight will be randomized and assigned to either an intervention group with PEEP adjusted according to BMI or a control group with a standardized PEEP of 5 mbar. Pre- and postoperatively, lung ultrasound will be performed to determine the lung aeration score, and hemodynamic and respiratory vital signs will be recorded for subsequent evaluation. The primary outcome is the difference in ΔP as a surrogate parameter for lung-protective ventilation. Secondary outcomes include change in lung aeration score, intraoperative occurrence of hemodynamic and respiratory events, oxygen requirements and postoperative pulmonary complications. Discussion: The study results will show whether an intraoperative ventilation strategy with PEEP adjustment based on BMI has the potential of reducing the risk for postoperative pulmonary complications as an easy-to-implement intervention that does not require lengthy ventilator maneuvers nor additional equipment. Trial registration: German Clinical Trials Register (DRKS), DRKS00031336. Registered 21st February 2023. Trial status: The study protocol was approved by the ethics committee of the Christian-Albrechts-Universität Kiel, Germany, on 1st February 2023. Recruitment began in March 2023 and is expected to end in September 2023.
- 1 January 2024
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (1) , 015001
Distribution of regional lung function in upright healthy subjects determined by electrical impedance tomography in two chest examination planes
Objective . The variation in pulmonary gas content induced by ventilation is not uniformly distributed in the lungs. The aim of our study was to characterize the differences in spatial distribution of ventilation in two transverse sections of the chest using electrical impedance tomography (EIT). Approach . Twenty adult never-smokers, 10 women and 10 men (mean age ± SD, 31 ± 9 years), were examined in a sitting position with the EIT electrodes placed consecutively in a caudal (6th intercostal space) and a cranial (4th intercostal space) chest location. EIT data were acquired during quiet breathing, slow and forced full expiration manoeuvres. Impedance variations representing tidal volume ( V T ), vital capacity (VC), forced expiratory volume in 1 s (FEV 1 ) and forced vital capacity (FVC) were calculated at the level of individual image pixels and their spatial distribution was determined using the following EIT measures: the centres of ventilation in ventrodorsal (CoV vd ) and right-to-left direction (CoV rl ), the dorsal and right fractions of ventilation, the coefficient of variation (CV) and the global inhomogeneity (GI) index. Main results . The sums of pixel ventilation-related impedance variations reproduced reliably the volumetric dissimilarities among V T , VC, FEV 1 and FVC, with no significant differences noted between the two examination planes. Significant differences in ventilation distribution were found between the planes during tidal breathing and slow full expiration, mainly regarding the ventrodorsal direction, with higher values of CoV vd and dorsal fraction of ventilation in the caudal plane ( p < 0.01). No significant differences in the spatial distribution of FEV 1 and FVC were detected between the examination planes. Significance . The spatial distribution of ventilation differed between the two examination planes only during the relaxed (quiet breathing and slow VC manoeuvre) but not during the forced ventilation. This effect is attributable to the differences in thoracoabdominal mechanics between these types of ventilation.
- 1 January 2024
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (1) , 015001
Distribution of regional lung function in upright healthy subjects determined by electrical impedance tomography in two chest examination planes
Objective . The variation in pulmonary gas content induced by ventilation is not uniformly distributed in the lungs. The aim of our study was to characterize the differences in spatial distribution of ventilation in two transverse sections of the chest using electrical impedance tomography (EIT). Approach . Twenty adult never-smokers, 10 women and 10 men (mean age ± SD, 31 ± 9 years), were examined in a sitting position with the EIT electrodes placed consecutively in a caudal (6th intercostal space) and a cranial (4th intercostal space) chest location. EIT data were acquired during quiet breathing, slow and forced full expiration manoeuvres. Impedance variations representing tidal volume ( V T ), vital capacity (VC), forced expiratory volume in 1 s (FEV 1 ) and forced vital capacity (FVC) were calculated at the level of individual image pixels and their spatial distribution was determined using the following EIT measures: the centres of ventilation in ventrodorsal (CoV vd ) and right-to-left direction (CoV rl ), the dorsal and right fractions of ventilation, the coefficient of variation (CV) and the global inhomogeneity (GI) index. Main results . The sums of pixel ventilation-related impedance variations reproduced reliably the volumetric dissimilarities among V T , VC, FEV 1 and FVC, with no significant differences noted between the two examination planes. Significant differences in ventilation distribution were found between the planes during tidal breathing and slow full expiration, mainly regarding the ventrodorsal direction, with higher values of CoV vd and dorsal fraction of ventilation in the caudal plane ( p < 0.01). No significant differences in the spatial distribution of FEV 1 and FVC were detected between the examination planes. Significance . The spatial distribution of ventilation differed between the two examination planes only during the relaxed (quiet breathing and slow VC manoeuvre) but not during the forced ventilation. This effect is attributable to the differences in thoracoabdominal mechanics between these types of ventilation.