TSTsutomu Sugaya

Tsutomu Sugaya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tsutomu Sugaya has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Impact of electrode distance, axial position, and energization time on cauterization of root canal isthmuses using high-frequency current

    by Ahmed Saud Alkuwaykibi, Tsutomu Sugaya, Mohammed Katib Alruwaili, Naoki Takahashi

    This in vitro proof-of-concept study evaluated how the isthmus gap width, distance between electrodes, and duration of high-frequency electrical current application affect surface morphological changes of simulated isthmus inner surfaces. Simulated isthmus models were prepared using bovine dentin blocks immersed in Plank-Rychlo solution to create organic layers. Isthmus gap widths of 0.1, 0.2, and 0.3 mm were created. Two root canals were prepared at distances of 2 mm or 5 mm, creating six groups (n = 10 each). Root canals were filled with NaOCl, and #35 K-files served as electrodes. A high-frequency current (225 V, 520 kHz) was applied for 5 or 10 s. The demineralized surface morphology (decalcified surface) prior to HFC application served as the baseline reference for evaluating cauterization outcomes. Isthmus surfaces were analyzed using scanning electron microscopy and energy dispersive X-ray spectroscopy. High-frequency current application produced surface morphological changes consistent with cauterization, including exposure of dentinal tubules. Fisher's exact test showed significant differences in cauterization rates, since Group 1 showed less organic residue than Groups 4 and 5 (p < 0.05). In Groups 3 and 4, 10-s application significantly decreased organic material compared to 5-s application (p < 0.001). Ordinal logistic regression analysis confirmed that electrode distance (OR = 0.854, p < 0.0001), axial position (OR = 0.444, p < 0.0001), and energization time (OR = 3.276, p < 0.0001) were significant predictors, whereas gap width was not (p = 0.542). Coronal regions showed significantly higher cauterization rates than apical regions (91.6% [466/509] vs 68.2% [347/509]). Within the limitations of this in vitro proof-of-concept study, electrode distance, axial position, and energization time significantly influenced surface morphological outcomes. Extending energization time from 5 to 10 s increased the odds of achieving higher-grade surface morphological changes by 3.3-fold. Gap width did not significantly affect the outcome. Electrode distance, axial position, and energization time are critical parameters for high-frequency cauterization of simulated root canal isthmuses. These proof-of-concept findings may inform future investigations into the clinical application of this technique for areas inaccessible to conventional instrumentation.

  • Water-resistant antibacterial properties of a graphene oxide/cetylpyridinium chloride complex formed on medical gauze fibers

    by Yukimi Kanemoto, Hirofumi Miyaji, Erika Nishida, Asako Hamamoto, Tsutomu Sugaya, Syun Gohda, Hironobu Ono


  • Open Access

    Antibacterial coating of tooth surface with ion-releasing pre-reacted glass-ionomer (S-PRG) nanofillers

    by Kayoko Mayumi, Hirofumi Miyaji, Saori Miyata, Erika Nishida, Tomokazu Furihata, Yukimi Kanemoto, Tsutomu Sugaya, Kanako Shitomi, Tsukasa Akasaka


  • Open Access

    Preparation of micro/nanopatterned gelatins crosslinked with genipin for biocompatible dental implants

    by Reika Makita, Tsukasa Akasaka, Seiichi Tamagawa, Yasuhiro Yoshida, Saori Miyata, Hirofumi Miyaji, Tsutomu Sugaya

    Background: Collagen is a basic component of the periodontium and plays an important role in the function of the periodontal unit. Therefore, coating with collagen/gelatin has been applied to enable dental implants to positively interact with peri-implant tissues. Although the micro/nanoscale topography is an important property of the surface of dental implants, smaller collagen/gelatin surface patterns have not been sufficiently developed. Furthermore, only few reports on the behavior of cells on gelatin surfaces with different patterns and sizes exist. In this study, we developed micro/nanometer-scaled gelatin surfaces using genipin crosslinking, with the aim of understanding the use of patterning in surface modification of dental implants.Results: Grooves, holes, and pillars, with widths or diameters of 2 µm, 1 µm, or 500 nm were fabricated using a combination of molding and genipin crosslinking of gelatin. The stability of the different gelatin patterns could be controlled by the degree of genipin crosslinking. The gelatin patterns at 20 mM concentration of genipin and 41% crosslinking maintained a stable, patterned shape for at least 14 days in a cell culture medium. A cell morphology study showed that the cells on groves were aligned along the direction of the grooves. In contrast, the cells on pillars and holes exhibited randomly elongated filopodia. The vinculin spots of the cells were observed on the top of ridges and pillars or the upper surface of holes. The results of a cell attachment assay showed that the number of surface-attached cells increased with increasing patterning of the gelatin surface. Unlike the cell attachment assay, the results of a cell proliferation assay showed that Saos-2 cells prefer grooves with diameters of approximately 2 µm and 1 µm and pillars with diameters of 1 µm and heights of 500 nm. The number of cells on pillars with heights of 2 µm was larger than those of the other gelatin surface patterns tested.Conclusion: These data support that a detailed design of the gelatin surface pattern can control both cell attachment and proliferation of Saos-2 cells. Thus, gelatin surfaces patterned using genipin crosslinking are now an available option for biocompatible material patterning.


  • Open Access

    Bone Perforation and Placement of Collagen Sponge Facilitate Bone Augmentation

    by Shinji Shimoji, Hirofumi Miyaji, Tsutomu Sugaya, Hifumi Tsuji, Tetsunari Hongo, Megumi Nakatsuka, Khurshid Uz Zaman, Masamitsu Kawanami

    Background: Bone perforation may induce bone marrow cell migration into a collagen sponge onlay implant. This study investigated the efficacy of bone perforation and collagen sponge onlay placement with regard to new bone formation.Methods: One hundred sixty femurs of 80 Wistar male rats were used in four groups: bone perforation and sponge (PS) group: after perforating the femur, fibrillar and heat‐denatured collagen (FC‐HAC) sponges were placed on the femur; sponge (S) group: a FC‐HAC sponge was placed directly on the femur without bone perforation; perforation (P) group: femur perforation without collagen sponge placement; and control (C) group: neither bone perforation nor sponge placement was used. Histologic and histomorphometric analyses were performed after the surgery.Results: Numerous osteoblastic and fibroblastic cells were seen during the early repopulation in and at the periphery of the sponge in the PS group. These cells were seen only at the periphery of the sponge in the S group. In the PS group, angiogenesis was noted frequently, and it exhibited significantly greater new bone area compared to the other groups at days 14 and 28.Conclusion: The use of the FC‐HAC sponge on the bone perforation area seemed to promote bone augmentation by possibly acting as a scaffold for the bone marrow cells as well as maintaining the space that is necessary for bone growth to occur.


  • Open Access

    Durability of Adhesion between 4-META/MMA-TBB Resin and Cementum

    by Yuko Tanaka, Tsutomu Sugaya, Masamitsu Kawanami

    4-META/MMA-TBB resin has shown good biocompatibility and remarkable adhesion to dentin. It seems to be suitable for use in periodontal tissues for retrograde root sealing and treatment of vertically fractured roots. For an adhesive resin to be useful clinically, it must bond not only to the dentin but also to the cementum. The purpose of this study was to evaluate the long-term adhesion durability of 4-META/MMA-TBB resin to cementum kept in water at 37 degrees C. Bovine root cementum and dentin surfaces were treated with 10-3 solution before 4-META/MMA-TBB resin was applied on treated surfaces. The micro-tensile bond strength (microTBS) decreased during the first two months; dye leakage value increased during the first four months and stabilized thereafter. No significant differences in adhesion durability were recognized between the dentin and cementum.