CMCarolin Meyer

Carolin Meyer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carolin Meyer has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Endoscopic Facet Joint Denervation on the Lumbar Spine: A Retrospective Analysis

    by Franziska Wallscheid, Maximilian Manthey, Jerome Olsen, Stavros Oikonomidis, Carolin Meyer, Peer Eysel, Lars Löhrer, Jan Bredow

    Study Design: This single-center retrospective study analyzed patients with chronic low back pain (CLBP) who underwent endoscopic facet joint denervation (EFJD) between April 2018 and May 2019.Purpose: This study was designed to investigate the effectiveness of EFJD in treating CLBP.Overview of Literature: CLBP is a challenging burden to healthcare systems worldwide. As up to 45% of cases originate from the lumbar facet joints, sufficient therapy strategies must be developed. EFJD offers a precise depiction of the dorsal medial ramus and the facet joint capsule.Methods: In this study, 64 patients who underwent EFJD were included. The main outcome of interest was patients’ Visual Analog Scale (VAS) pain score, which was recorded at 3-time points (i.e., before operation and 6 weeks and 12 months after surgery).Results: EFJD effectively reduced the VAS pain scores by 58% in the short term (6 weeks) and 38% in the long term (12 months). Patients with isolated facet joint osteoarthritis benefited more (p <0.001).Conclusions: EFJD is a good treatment alternative for CLBP originating from the facet joints, particularly in patients with isolated facet joint osteoarthritis. Moreover, this method can address not only the dorsal medial ramus but also the surrounding tissue (e.g., facet joint capsule, facet joint effusion, and osteophytes) as the origin of CLBP.


  • Open Access

    Bisphenol A-Related Effects on Bone Morphology and Biomechanical Properties in an Animal Model

    by Tobias Prasse, Ioannis Stratos, Anja Niehoff, Hildegard Christ, Vincent Heck, Carolin Meyer, Thomas Mittlmeier

    Bisphenol A (BPA), which is contained in numerous plastic products, is known to act as an endocrine-disruptive, toxic, and carcinogenic chemical. This experimental series sought to determine the influence of BPA exposure on the femoral bone architecture and biomechanical properties of male and female Wistar rats. BPA was applied subcutaneously by using osmotic pumps. After 12 weeks, the bones were analyzed by micro-computed tomography (micro-CT) and a three-point bending test. Comparing the female low- and high-dose groups, a significantly greater marrow area (p = 0.047) was identified in the group exposed to a higher BPA concentration. In addition, the trabecular number tended to be higher in the female high-dose group when compared to the low-dose group (p > 0.05). The area moment of inertia also tended to be higher in the male high-dose group when compared to the male low-dose group (p > 0.05). Considering our results, BPA-related effects on the bone morphology in female Wistar rats are osteoanabolic after high-dose exposure, while, in male rats, a tendency toward negative effects on the bone morphology in terms of a reduced cross-sectional cortical area and total area could be demonstrated.


  • Open Access

    Does the Current State of Evidence Justify the Broad Use of Cross-Links in Dorsal Instrumentation? A Systematic Review

    by Vincent J. Heck, Stavros Oikonomidis, Tobias Prasse, Carolin Meyer, Max J. Scheyerer, Wolfgang A. Wetsch, Peer Eysel, Jan Bredow

    Cross-links increase the stability of screw-rod systems in biomechanical testing. The aim of this systemic review was to find evidence pertaining to the additional benefit of the implantation of cross-links in clinical practice in regard to different spinal diseases. Therefore, a systematic literature analysis of two online databases was performed according to the PRISMA statement. Inclusion criteria were prospective and retrospective studies investigating the use of cross-links in dorsal instrumentation. Biomechanical studies and case series were excluded. A total of seven retrospective studies remained for final full-text evaluation. In total, two studies each address the use of cross-links in adolescent idiopathic scoliosis, neuromuscular scoliosis or atlantoaxial fusion, one study in congenital scoliosis. In atlantoaxial fusion the additional use of cross-links may provide earlier bony fusion. In surgical treatment for pediatric scoliosis the additional use of cross-links does not provide additional benefit. Radiological outcome and complication rate did not differ in between groups. No study addressed the use of cross-links in short- or long-segment fusion due to degenerative or traumatic disorders of the spine. There is a deficiency in published literature towards the impact of cross-links in spinal surgery. The current clinical evidence data do not confirm the biomechanical advantages of cross-links in clinical practice. Further studies are needed to warrant the use of cross-links in the future.

  • Open Access

    Early Spinal Injury Stabilization in Multiple-Injured Patients: Do All Patients Benefit?

    by Philipp Kobbe, Patrick Krug, Hagen Andruszkow, Miguel Pishnamaz, Martijn Hofman, Klemens Horst, Carolin Meyer, Max Joseph Scheyerer, Christoph Faymonville, Gregor Stein, et al.

    Background: Thoracolumbar spine fractures in multiple-injured patients are a common injury pattern. The appropriate timing for the surgical stabilization of vertebral fractures is still controversial. The purpose of this study was to analyse the impact of the timing of spinal surgery in multiple-injured patients both in general and in respect to spinal injury severity. Methods: A retrospective analysis of multiple-injured patients with an associated spinal trauma within the thoracic or lumbar spine (injury severity score (ISS) >16, age >16 years) was performed from January 2012 to December 2016 in two Level I trauma centres. Demographic data, circumstances of the accident, and ISS, as well as time to spinal surgery were documented. The evaluated outcome parameters were length of stay in the intensive care unit (ICU) (iLOS) and length of stay (LOS) in the hospital, duration of mechanical ventilation, onset of sepsis, and multiple organ dysfunction syndrome (MODS), as well as mortality. Statistical analysis was performed using SPSS. Results: A total of 113 multiple-injured patients with spinal stabilization and a complete dataset were included in the study. Of these, 71 multiple-injured patients (63%) presented with an AOSpine A-type spinal injury, whereas 42 (37%) had an AOSpine B-/C-type spinal injury. Forty-nine multiple-injured patients (43.4%) were surgically treated for their spinal injury within 24 h after trauma, and showed a significantly reduced length of stay in the ICU (7.31 vs. 14.56 days; p < 0.001) and hospital stay (23.85 vs. 33.95 days; p = 0.048), as well as a significantly reduced prevalence of sepsis compared to those surgically treated later than 24 h (3 vs. 7; p = 0.023). These adverse effects were even more pronounced in the case where cutoffs were increased to either 72 h or 96 h. Independent risk factors for a delay in spinal surgery were a higher ISS (p = 0.036), a thoracic spine injury (p = 0.001), an AOSpine A-type spinal injury (p = 0.048), and an intact neurological status (p < 0.001). In multiple-injured patients with AOSpine A-type spinal injuries, an increased time to spinal surgery was only an independent risk factor for an increased LOS; however, in multiple-injured patients with B-/C-type spinal injuries, an increased time to spinal surgery was an independent risk factor for increased iLOS, LOS, and the development of sepsis. Conclusion: Our data support the concept of early spinal stabilization in multiple-injured patients with AOSpine B-/C-type injuries, especially of the thoracic spine. However, in multiple-injured patients with AOSpine A-type injuries, the beneficial impact of early spinal stabilization has been overemphasized in former studies, and the benefit should be weighed out against the risk of patients’ deterioration during early spinal stabilization.


  • Impact of lumbar pedicle screw positioning on screw stability - A biomechanical investigation

    by David Grevenstein, Max J. Scheyerer, Carolin Meyer, Jan Borggrefe, Michael Hackl, Stavros Oikonomidis, Peer Eysel, Andreas Prescher, Kilian Wegmann


  • The sacral screw placement depending on morphological and anatomical peculiarities

    by Carolin Meyer, Peter Pfannebecker, Jan Siewe, David Grevenstein, Jan Bredow, Peer Eysel, Max Joseph Scheyerer

    Various pathologies of the lumbosacral junction require fusion of the L5/S1 segment. However, pseudarthroses, which often come along with sacral screw loosening, are problematic. The aim of the present investigation was to elaborate the morphological features of the L5/S1 segment to define a so-called “safe zone” for bi- or tricortical screw placement without risking a damage of the iliac vessels.


  • Myelon Stent – a New Technical Procedure to Protect the Spinal Cord Against Tumour Compression

    by Peer Eysel, Christoph Baltin, Carolin Meyer

    A 59-year-old woman with breast cancer who had undergone chemotherapy, three surgical interventions at the thoracic spine, and radiation since 2012, suffered from progressive ataxia caused by a single relapse metastasis resulting in spinal stenosis at thoracic level 6. Therefore, excessive tumour debulking was performed at thoracic levels 4 to 7 and a fully covered, self-expandable stent was placed around the spinal cord at these levels in order to create a mechanical barrier and to prevent the spinal cord from compression by the tumour. Neuromonitoring was performed before, during, and after surgical procedure. Clinically and electrophysiologically, ataxia appeared improved after intervention. Radiologically, no tumour growth was found at thoracic levels 4 to 7 after the intervention.

  • First results of multicortical screw anchoring compared with conventional bicortical screw placement in the sacrum: A biomechanical investigation of a new screw design

    by David Grevenstein, Carolin Meyer, Kilian Wegmann, Michael Hackl, Jan Bredow, Peer Eysel, Andreas Prescher, Max J. Scheyerer


  • Open Access

    Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement

    by Carolin Meyer, Kerstin van Gaalen, Tim Leschinger, Max J. Scheyerer, Wolfram F. Neiss, Manfred Staat, Lars P. Müller, Kilian Wegmann

    If conservative treatment of osteoporotic vertebral compression fractures fails, vertebro- or kyphoplasty is indicated. Usually, polymethylmethacrylate cement (PMMA) is applied coming along with many disadvantageous features. Aluminum-free glass-polyalkenoate cement (GPC) appears to be a benefit alternative material. This study aimed at comparing the mean stress values in human vertebrae after kyphoplasty with PMMA and GPC (IlluminOss™) at hand of a finite element analysis. Three models were created performing kyphoplasty using PMMA or IlluminOss™, respectively, at two native, human lumbar vertebrae (L4) while one remains intact. Finite element analysis was performed using CT-scans of every vertebra. Moreover the PMMA-treated vertebra was used as a model as analyses were executed using material data of PMMA and of GPC. The unimpaired, spongious bone showed potentials of 0.25 MPa maximally. After augmentation stress levels showed fivefold increase, rising from externally to internally, revealing stress peaks at the ventral border of the spinal canal. At central areas of cement 1 MPa is measured in both types of cement. Around these central areas the von Mises stress decreased about 25-50% (0.5-0.75 MPa). If workload of 500 N was applied, the stress appeared to be more centralized at the IlluminOss™-model, similar to the unimpaired. Considering the endplates the GPC model also closely resembles the unimpaired. Comparing the PMMA-treated vertebral body and the GPC-simulation, there is an obvious difference. While the PMMA-treated model showed a central stress peak of 5 MPa, the GPC-simulation of the same vertebral body presents lower stress of 1.2-2.5 MPa. Finite element analysis showed that IlluminOss™ (GPC), used in kyphoplasty of vertebral bodies, creates lower level stress and strain compared to standardly used PMMA, leading to lower stress concentrations on the cranial and caudal vertebral surface especially. GPC appears to own advantageous biological and clinical relevant features.


  • Open Access

    Traumatic Atlantoaxial and Fracture-Related Dislocation

    by Carolin Meyer, Peer Eysel, Gregor Stein

    Traumatic atlantoaxial dislocation due to ligamentous and combined osseous injuries rarely occurs in adults. There are only few cases published in the literature. In this level 4 study, a cohort of nine consecutive patients suffering from traumatic atlantoaxial dislocation has been analyzed regarding morphology of injury, trauma mechanism, and outcome since 2007. Three types of those injuries have been found regarding direction of dislocation indicating the underlying ligamentous injuries as well as the accompanying grade of instability. Firstly, there was rotatory dislocation, if the alar ligaments were injured. Secondly, there occurred horizontal dislocation, when transverse atlantal ligament was damaged additionally. Thirdly, excessive ligamentous injury led to distraction of the atlantoaxial complex resulting in dissociation of the atlas against the axis. Additionally fractures of the atlas as well as of the odontoid process (type II or III according to Anderson/D’Alonzo) were diagnosed frequently. Atlantoaxial dislocation injuries, especially distraction injuries, offer a high risk for accompanied neurovascular disorders deserving reduction followed by surgical fixation. Only rotatory injuries leading to ligamentous damage solitarily can safely be successfully treated conservatively. Understanding of the injuries’ morphology is essential, in order to set the correct diagnosis and to implicate the most advantageous treatment regime.