Ke Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ke Han has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
Tao Zhang
Shanghai Jiao Tong University
17 shared publicationsKarl Giboni
Shanghai Jiao Tong University
16 shared publicationsLi Zhao
Shanghai Jiao Tong University
16 shared publications- Yu Gang Ma
Fudan University
16 shared publications S. J. Freedman
Department of Physics, University of California, Berkeley, USA
15 shared publicationsT. Wise
Department of Physics, Yale University, New Haven, USA
15 shared publications
Latest Publications
- Open Access
- 8 June 2026
- Published by Elsevier in Physics Letters B
- Vol. 879
Sensitivity of neutrinoless double beta decays from a combined analysis of ground and excited states
- 8 June 2026
- Published by Elsevier in Physics Letters B
- Vol. 879
Open AccessSensitivity of neutrinoless double beta decays from a combined analysis of ground and excited states
- 4 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (6) , 2511-2519
Performance Study and Circuit Simulation for R12699-406-M4 Photomultiplier Tube Base
The next-generation liquid xenon experiments like PandaX-xT target an energy range from sub-keV to multi-MeV to address the requirement of multiple physics searches. The Hamamatsu R12699-406-M4 photomultiplier tubes (PMTs) were developed and selected as photon sensors for PandaX-xT. Their voltage-divider base is optimized for a broad dynamic range, from single-photoelectron (SPE) sensitivity to 30 nC collected charge (matching the 2.458 MeV Q-value of 136Xe neutrinoless double beta decay (NLDBD)). Using a dedicated test bench, we characterize the saturation and suppression responses of R12699-406-M4 PMTs with this base design. Based on measured PMT-base responses, we develop a circuit simulation model that accurately reproduces the physical mechanisms underlying these effects with key parameters tuned via experimental data. The combined simulation and bench-test approach guides base design and optimization, enabling improved detector dynamic range and supporting future saturation and suppression correction studies in data analysis.
- 4 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (6) , 2511-2519
Performance Study and Circuit Simulation for R12699-406-M4 Photomultiplier Tube Base
The next-generation liquid xenon experiments like PandaX-xT target an energy range from sub-keV to multi-MeV to address the requirement of multiple physics searches. The Hamamatsu R12699-406-M4 photomultiplier tubes (PMTs) were developed and selected as photon sensors for PandaX-xT. Their voltage-divider base is optimized for a broad dynamic range, from single-photoelectron (SPE) sensitivity to 30 nC collected charge (matching the 2.458 MeV Q-value of 136Xe neutrinoless double beta decay (NLDBD)). Using a dedicated test bench, we characterize the saturation and suppression responses of R12699-406-M4 PMTs with this base design. Based on measured PMT-base responses, we develop a circuit simulation model that accurately reproduces the physical mechanisms underlying these effects with key parameters tuned via experimental data. The combined simulation and bench-test approach guides base design and optimization, enabling improved detector dynamic range and supporting future saturation and suppression correction studies in data analysis.
- 26 January 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (1)
Precise measurement of Po 216 half-life with exact parent-daughter pairing in PandaX-4T
- 26 January 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (1)
Precise measurement of Po 216 half-life with exact parent-daughter pairing in PandaX-4T
- Open Access
Precision measurement and modelling of the threshold-free 210Pb β spectrum
Beta decay is a fundamental process that governs nuclear stability and serves as a sensitive probe of the weak interaction and possible physics beyond the Standard Model of particle physics. However, precise measurements of complete $β$ decay spectra, particularly at low energies, remain experimentally and theoretically challenging. Here we report a high-precision, threshold-free measurement of the full $β$ decay spectrum of 210Pb to excited states of 210Bi, using a transition-edge sensor (TES)-based micro-calorimeter. This approach enables the detection of $β$ particle energies from 0 keV up to their endpoint by coincidence summing with subsequent de-excitation energy, thereby eliminating reconstruction artifacts near zero energy that have traditionally limited low-energy spectral accuracy. To our knowledge, this is the first complete, high-precision $β$ decay spectrum from 0 keV. The data resolve theoretical uncertainties associated with the atomic quantum exchange (AQE) effect. An accompanying ab initio theoretical framework, incorporating atomic, leptonic, and nuclear components, predicts a statistically significant (7.2 {$σ$}) enhancement in $β$ emission probability near zero energy, in agreement with the measurement and in contrast to models that omit AQE corrections. These results provide a new benchmark for $β$ decay theory at low energies, deepen our understanding of the weak interaction, and establish a critical foundation for searches for new physics, including dark matter interactions and precision studies of neutrinos.Open AccessPrecision measurement and modelling of the threshold-free 210Pb β spectrum
Beta decay is a fundamental process that governs nuclear stability and serves as a sensitive probe of the weak interaction and possible physics beyond the Standard Model of particle physics. However, precise measurements of complete $β$ decay spectra, particularly at low energies, remain experimentally and theoretically challenging. Here we report a high-precision, threshold-free measurement of the full $β$ decay spectrum of 210Pb to excited states of 210Bi, using a transition-edge sensor (TES)-based micro-calorimeter. This approach enables the detection of $β$ particle energies from 0 keV up to their endpoint by coincidence summing with subsequent de-excitation energy, thereby eliminating reconstruction artifacts near zero energy that have traditionally limited low-energy spectral accuracy. To our knowledge, this is the first complete, high-precision $β$ decay spectrum from 0 keV. The data resolve theoretical uncertainties associated with the atomic quantum exchange (AQE) effect. An accompanying ab initio theoretical framework, incorporating atomic, leptonic, and nuclear components, predicts a statistically significant (7.2 {$σ$}) enhancement in $β$ emission probability near zero energy, in agreement with the measurement and in contrast to models that omit AQE corrections. These results provide a new benchmark for $β$ decay theory at low energies, deepen our understanding of the weak interaction, and establish a critical foundation for searches for new physics, including dark matter interactions and precision studies of neutrinos. - Open Access
Precise Measurement of $^{216}$Po Half-life with Exact Parent-daughter Pairing in PandaX-4T
We report a precise measurement of $^{216}\rm Po$ half-life using the PandaX-4T liquid xenon time projection chamber (TPC). $^{220}\rm Rn $, emanating from a $^{228}\rm Th $ calibration source, is injected to the detector and undergoes successive $α$ decays, first to $^{216}\rm Po$ and then to $^{212}\rm Pb$. PandaX-4T detector measures the 5-dimensional (5D) information of each decay, including time, energy, and 3-dimensional positions. Therefore, we can identify the $^{220}\rm Rn $ and $^{216}\rm Po$ decay events and pair them exactly to extract the lifetime of each $^{216}\rm Po$. With a large data set and high-precision $^{220}\rm $Rn-$^{216}\rm $Po pairing technique, we measure the $^{216}\rm Po$ half-life to be $143.7\pm0.5$ ms, which is the most precise result to date and agrees with previously published values. The leading precision of this measurement demonstrates the power of 5D calorimeter and the potential of exact parent-daughter pairing in the xenon TPC.Open AccessPrecise Measurement of $^{216}$Po Half-life with Exact Parent-daughter Pairing in PandaX-4T
We report a precise measurement of $^{216}\rm Po$ half-life using the PandaX-4T liquid xenon time projection chamber (TPC). $^{220}\rm Rn $, emanating from a $^{228}\rm Th $ calibration source, is injected to the detector and undergoes successive $α$ decays, first to $^{216}\rm Po$ and then to $^{212}\rm Pb$. PandaX-4T detector measures the 5-dimensional (5D) information of each decay, including time, energy, and 3-dimensional positions. Therefore, we can identify the $^{220}\rm Rn $ and $^{216}\rm Po$ decay events and pair them exactly to extract the lifetime of each $^{216}\rm Po$. With a large data set and high-precision $^{220}\rm $Rn-$^{216}\rm $Po pairing technique, we measure the $^{216}\rm Po$ half-life to be $143.7\pm0.5$ ms, which is the most precise result to date and agrees with previously published values. The leading precision of this measurement demonstrates the power of 5D calorimeter and the potential of exact parent-daughter pairing in the xenon TPC. - Open Access
- 14 May 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (5) , 1-19
Measurement of two-neutrino double electron capture half-life of 124Xe with PandaX-4T
Detailed studies of two-neutrino double electron capture (2νDEC) is a crucial step towards searching for the neutrinoless mode to explore the Majorana nature of neutrinos. We have measured precisely the half-life of the 2νDEC process in 124Xe, utilizing a total exposure of 1.73 tonne year from the commissioning run and the first science run of the PandaX-4T experiment. A time-dependent background model in the $$ \mathcal{O} $$ (10 keV) energy is constructed for the first time in PandaX-4T data. With an unbinned maximum likelihood fit, we determine the half-life of the 2νDEC process to be (1.03 ± 0.15stat ± 0.08sys) × 1022 yr. Furthermore, we have evaluated the capture fraction for both electrons captured from the K shell (KK) to be (65 ± 5)%, which aligns with the 124Xe nuclear model calculations within 1.8 σ.- 14 May 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (5) , 1-19
Open AccessMeasurement of two-neutrino double electron capture half-life of 124Xe with PandaX-4T
Detailed studies of two-neutrino double electron capture (2νDEC) is a crucial step towards searching for the neutrinoless mode to explore the Majorana nature of neutrinos. We have measured precisely the half-life of the 2νDEC process in 124Xe, utilizing a total exposure of 1.73 tonne year from the commissioning run and the first science run of the PandaX-4T experiment. A time-dependent background model in the $$ \mathcal{O} $$ (10 keV) energy is constructed for the first time in PandaX-4T data. With an unbinned maximum likelihood fit, we determine the half-life of the 2νDEC process to be (1.03 ± 0.15stat ± 0.08sys) × 1022 yr. Furthermore, we have evaluated the capture fraction for both electrons captured from the K shell (KK) to be (65 ± 5)%, which aligns with the 124Xe nuclear model calculations within 1.8 σ. - 13 March 2025
- Published by Elsevier in Science Bulletin
- Vol. 70 (11) , 1779-1785
Searching for neutrinoless double-beta decay of 136 Xe with PandaX-4T
- 13 March 2025
- Published by Elsevier in Science Bulletin
- Vol. 70 (11) , 1779-1785
Searching for neutrinoless double-beta decay of 136 Xe with PandaX-4T
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (5) , 1800-1809
Characterization of a Gaseous Time Projection Chamber With an Internal ³⁷Ar Source
We report on a novel calibration method of gaseous detectors using an internal 37Ar source. The 37Ar is a fast-decaying and low-energy calibration source that provides a mono-energetic peak of 2.82 keV. A gaseous 37Ar source is injected and uniformly distributed in a Micromegas-based gaseous time projection chamber (TPC). Key performance parameters of the detector, such as electron transmission, gain, energy resolution, gain uniformity, and drift field evolution, are effectively and quickly calibrated. The gain uniformity, related to the homogeneity of the avalanche gap of Micromegas, is calibrated quickly thanks to the event-by-event position reconstruction and quasi-point energy deposition of 37Ar. The energy resolution is improved with the obtained gain uniformity map. The most noticeable improvement in energy resolution, from 44.9% to 35.4%, is observed at a working pressure of 7 bar. The internal calibration source is also used to characterize the dependence of the detector’s electric field distortion on the drift field.
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (5) , 1800-1809
Characterization of a Gaseous Time Projection Chamber With an Internal ³⁷Ar Source
We report on a novel calibration method of gaseous detectors using an internal 37Ar source. The 37Ar is a fast-decaying and low-energy calibration source that provides a mono-energetic peak of 2.82 keV. A gaseous 37Ar source is injected and uniformly distributed in a Micromegas-based gaseous time projection chamber (TPC). Key performance parameters of the detector, such as electron transmission, gain, energy resolution, gain uniformity, and drift field evolution, are effectively and quickly calibrated. The gain uniformity, related to the homogeneity of the avalanche gap of Micromegas, is calibrated quickly thanks to the event-by-event position reconstruction and quasi-point energy deposition of 37Ar. The energy resolution is improved with the obtained gain uniformity map. The most noticeable improvement in energy resolution, from 44.9% to 35.4%, is observed at a working pressure of 7 bar. The internal calibration source is also used to characterize the dependence of the detector’s electric field distortion on the drift field.
- Open Access
- 29 January 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (4) , 041001
Exploring New Physics with PandaX-4T Low Energy Electronic Recoil Data
New particles beyond the standard model of particle physics, such as axions, can be effectively searched through their interactions with electrons. We use the large liquid xenon detector PandaX-4T to search for novel electronic recoil signals induced by solar axions, neutrinos with anomalous magnetic moment, axionlike particles, dark photons, and light fermionic dark matter. A detailed background model is established using the latest datasets with 1.54 ton yr exposure. No significant excess above the background has been observed, and we have obtained competitive constraints for axion couplings, neutrino magnetic moment, and fermionic dark matter interactions.
- 29 January 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (4) , 041001
Open AccessExploring New Physics with PandaX-4T Low Energy Electronic Recoil Data
New particles beyond the standard model of particle physics, such as axions, can be effectively searched through their interactions with electrons. We use the large liquid xenon detector PandaX-4T to search for novel electronic recoil signals induced by solar axions, neutrinos with anomalous magnetic moment, axionlike particles, dark photons, and light fermionic dark matter. A detailed background model is established using the latest datasets with 1.54 ton yr exposure. No significant excess above the background has been observed, and we have obtained competitive constraints for axion couplings, neutrino magnetic moment, and fermionic dark matter interactions.