Karl Cammann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Karl Cammann has a total of 294 co-authors. Here are the top co-authors by number of shared publications:
C. Dumschat
Two new concepts of miniaturized reference electrodes are described. One reference electrode is based on a perchlorate sensitive sensor with solid KClO/sub4/ in a saturated solution on top of the perchlorate sensitive sensor. The other is a redox reference electrode with an protecting electrode
16 shared publicationsM. Knoll
16 shared publicationsAndreas Katerkamp
Institut für Chemo- und Biosensorik, Mendelstrasse 7, 48149 Münster, Germany
12 shared publicationsC. Sundermeier
8 shared publicationsJörg Reinbold
Westfälische Wilhelms-Universität Münster
7 shared publicationsL. Quick
7 shared publications
Latest Publications
- 2 December 2010
- Published by Elsevier in Journal of Electroanalytical Chemistry and Interfacial Electrochemistry
- Vol. 229 (1-2) , 249-263
Apparent ion-exchange current densities at valinomycin-based potassium ion-selective PVC membranes obtained with an AC-impedance method
- 2 December 2010
- Published by Elsevier in Journal of Electroanalytical Chemistry and Interfacial Electrochemistry
- Vol. 229 (1-2) , 249-263
Apparent ion-exchange current densities at valinomycin-based potassium ion-selective PVC membranes obtained with an AC-impedance method
- 1 June 2009
- Published by Elsevier in Surface Science
- Vol. 603 (10-12) , 1353-1359
Contributions to a reliable hydrogen sensor based on surface plasmon surface resonance spectroscopy
- 1 June 2009
- Published by Elsevier in Surface Science
- Vol. 603 (10-12) , 1353-1359
Contributions to a reliable hydrogen sensor based on surface plasmon surface resonance spectroscopy
- 25 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 970-972
Two New Concepts Of Miniaturized Reference Electrodes
- 25 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 970-972
Two New Concepts Of Miniaturized Reference Electrodes
- 25 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 454-457
Optimization And Stabilization Of An Ultra Sensitive Biosensor For The Determination Of Inorganic Phosphate By Enzymatic Amplification
A new, highly sensitive enzyme sensor was developed for the determination of inorganic phosphate using maltose phosphorylase, acid phosphatase, glucose oxidase and mutarotase. Maltose phosphorylase from Lactobacillus brevis was purified to 98 % by a simple FPLC-aided procedure, including anion exchange chromatography, gel filtration and hydroxyapatite chromatography. The combination of the first two enzymes generates two glucose molecules per reaction cycle and recycles one molecule of phosphate. Finally, the oxidation of glucose is catalysed by mutarotase and glucose oxidase. Thus, a detection limit of 10/sup -8/ M was obtained and the sensor response was linear in the range 0.1-1 /spl mu/M, which is relevant for the monitoring of water pollution.
- 25 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 454-457
Optimization And Stabilization Of An Ultra Sensitive Biosensor For The Determination Of Inorganic Phosphate By Enzymatic Amplification
A new, highly sensitive enzyme sensor was developed for the determination of inorganic phosphate using maltose phosphorylase, acid phosphatase, glucose oxidase and mutarotase. Maltose phosphorylase from Lactobacillus brevis was purified to 98 % by a simple FPLC-aided procedure, including anion exchange chromatography, gel filtration and hydroxyapatite chromatography. The combination of the first two enzymes generates two glucose molecules per reaction cycle and recycles one molecule of phosphate. Finally, the oxidation of glucose is catalysed by mutarotase and glucose oxidase. Thus, a detection limit of 10/sup -8/ M was obtained and the sensor response was linear in the range 0.1-1 /spl mu/M, which is relevant for the monitoring of water pollution.
- 25 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 963-965
Thin-film Ion-selective Impedimetric Microsensors: A New Dimension In Ion Detection
- 25 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 963-965
Thin-film Ion-selective Impedimetric Microsensors: A New Dimension In Ion Detection
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 470-473
Microdialysis System For Continuous Glucose Monitoring
A microdialysis system for continuous glucose monitoring has been developed. The system has been optimized for in vivo applications. All the components have been miniaturized to get a small wearable device. It consists of a small gas driven syringe pump, the microdialysis sampling stage, a specially developed silicon flow through sensor chip with the integrated sensor elements and a flow rate adjusting capillary channel system, and the electronics. The performance of the system is demonstrated by in vitro measurements taken from human serum and glucose standard solutions.
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 470-473
Microdialysis System For Continuous Glucose Monitoring
A microdialysis system for continuous glucose monitoring has been developed. The system has been optimized for in vivo applications. All the components have been miniaturized to get a small wearable device. It consists of a small gas driven syringe pump, the microdialysis sampling stage, a specially developed silicon flow through sensor chip with the integrated sensor elements and a flow rate adjusting capillary channel system, and the electronics. The performance of the system is demonstrated by in vitro measurements taken from human serum and glucose standard solutions.
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 535-537
Pseudo-homogeneous Immunosensing With Tetrathiafulvalene-based Electrodes
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 535-537
Pseudo-homogeneous Immunosensing With Tetrathiafulvalene-based Electrodes
- 19 October 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 348 (8-9) , 549-552
Chemical sensor materials based on clathrates
- 19 October 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 348 (8-9) , 549-552
Chemical sensor materials based on clathrates
- 7 July 2004
- Published by Springer Nature in European Food Research and Technology
- Vol. 219 (3) , 286-293
Differentiation of animal species in food by oligonucleotide microarray hybridization
- 7 July 2004
- Published by Springer Nature in European Food Research and Technology
- Vol. 219 (3) , 286-293
Differentiation of animal species in food by oligonucleotide microarray hybridization