Francisco Rodríguez-Méndez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Francisco Rodríguez-Méndez has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bruno Chinè-Polito
Technological Institute of Costa Rica
4 shared publications - Marcela Meneses-Guzmán
Technological Institute of Costa Rica
4 shared publications - Melissa Alpízar-Arce
Technological Institute of Costa Rica
1 shared publication Moises Morera-Alfaro
Instituto Tecnológico de Costa Rica, Costa Rica
1 shared publication- Roberto Pereira-Arroyo
Department of Electronics Engineering, Instituto Tecnologico de Costa Rica, Cartago, Costa Rica
1 shared publication
Latest Publications
- Open Access
- 2 July 2026
- Published by Springer Nature
- p. 358-368
Statistical Characterization of an Aluminium Foam Using Compression Tests
- 2 July 2026
- Published by Springer Nature
- p. 358-368
Open AccessStatistical Characterization of an Aluminium Foam Using Compression Tests
- Open Access
- 30 May 2025
- Published by Instituto Tecnologico de Costa Rica in Investiga.TEC
- Vol. 18 (53) , 20-28
Desarrollo de un intercambiador de calor compacto con esponjas metálicas
Este artículo describe un trabajo de investigación desarrollado para evaluar experimentalmente un intercambiador de calor compacto fabricado mediante impresión 3D, en el cual se introducen esponjas metálicas de cobre para mejorar la superficie de intercambio térmico. Se han estudiado diversas condiciones de trabajo y configuraciones del dispositivo y los resultados experimentales han permitido obtener información para mejorar el sistema de intercambio de energía.
- 30 May 2025
- Published by Instituto Tecnologico de Costa Rica in Investiga.TEC
- Vol. 18 (53) , 20-28
Open AccessDesarrollo de un intercambiador de calor compacto con esponjas metálicas
Este artículo describe un trabajo de investigación desarrollado para evaluar experimentalmente un intercambiador de calor compacto fabricado mediante impresión 3D, en el cual se introducen esponjas metálicas de cobre para mejorar la superficie de intercambio térmico. Se han estudiado diversas condiciones de trabajo y configuraciones del dispositivo y los resultados experimentales han permitido obtener información para mejorar el sistema de intercambio de energía.
- Open Access
- 3 August 2023
- Published by Springer Nature
- p. 84-90
Thermo-mechanical Stress Modeling of La(Fe,Co,Si)13 Thin Films Deposited on Porous Structures
The thermo-mechanical behavior of a La(Fe,Co,Si)13 thin film deposited on a porous aluminum structure with a uniform geometry has been studied. Computational simulation techniques have been applied to the magnetocaloric material to model the thin film as a material with visco-plastic properties for thermal cycling at room temperature. The values obtained for stress, equivalent strain and cycles necessary for the material failure show a significant improvement in the mechanical stability and fatigue resistance of the metallic porous structure with the La(Fe,Co,Si)13 thin film, when compared to a model with the same geometry, but made entirely of La(Fe,Co,Si)13. These encouraging results prove the potential that this approach may have in the design and manufacture of magnetocaloric materials for magnetic refrigeration applications.
- 3 August 2023
- Published by Springer Nature
- p. 84-90
Open AccessThermo-mechanical Stress Modeling of La(Fe,Co,Si)13 Thin Films Deposited on Porous Structures
The thermo-mechanical behavior of a La(Fe,Co,Si)13 thin film deposited on a porous aluminum structure with a uniform geometry has been studied. Computational simulation techniques have been applied to the magnetocaloric material to model the thin film as a material with visco-plastic properties for thermal cycling at room temperature. The values obtained for stress, equivalent strain and cycles necessary for the material failure show a significant improvement in the mechanical stability and fatigue resistance of the metallic porous structure with the La(Fe,Co,Si)13 thin film, when compared to a model with the same geometry, but made entirely of La(Fe,Co,Si)13. These encouraging results prove the potential that this approach may have in the design and manufacture of magnetocaloric materials for magnetic refrigeration applications.
- Open Access
- 26 July 2019
- Published by Instituto Tecnologico de Costa Rica in Revista Tecnología en Marcha
- Vol. 32 (3) , 87-98
Desarrollo de un sistema automatizado de escaneo por radiación gamma
Las técnicas de medición por ensayos no destructivos han demostrado ser una poderosa herramienta en el estudio y caracterización de materiales. Este trabajo presenta el desarrollo de un sistema automatizado para la medición de la atenuación de radiación gamma en los materiales. Primero, se describe el proceso de diseño de los elementos electromecánicos y el sistema de control automático, seguido de su implementación. Los resultados muestran la capacidad y precisión mecánica obtenidas para el sistema desarrollado. En particular la resolución del motor y capacidad de recorrido del robot son respectivamente de 8 µm para el movimiento horizontal con un movimiento de hasta 54 cm bidireccional y 4 µm para el movimiento vertical con un movimiento de hasta 57 cm bidireccional. Además, el sistema permite una rotación de las muestras con un recorrido de 360° unidireccional. Se comprueba estadísticamente la sensibilidad del sistema para detectar cambios locales en el espesor del material, evaluando los periodos de muestreo para obtener una medición con precisión. Se determina el error relativo de las mediciones, analizando posibles causas y soluciones.
- 26 July 2019
- Published by Instituto Tecnologico de Costa Rica in Revista Tecnología en Marcha
- Vol. 32 (3) , 87-98
Open AccessDesarrollo de un sistema automatizado de escaneo por radiación gamma
Las técnicas de medición por ensayos no destructivos han demostrado ser una poderosa herramienta en el estudio y caracterización de materiales. Este trabajo presenta el desarrollo de un sistema automatizado para la medición de la atenuación de radiación gamma en los materiales. Primero, se describe el proceso de diseño de los elementos electromecánicos y el sistema de control automático, seguido de su implementación. Los resultados muestran la capacidad y precisión mecánica obtenidas para el sistema desarrollado. En particular la resolución del motor y capacidad de recorrido del robot son respectivamente de 8 µm para el movimiento horizontal con un movimiento de hasta 54 cm bidireccional y 4 µm para el movimiento vertical con un movimiento de hasta 57 cm bidireccional. Además, el sistema permite una rotación de las muestras con un recorrido de 360° unidireccional. Se comprueba estadísticamente la sensibilidad del sistema para detectar cambios locales en el espesor del material, evaluando los periodos de muestreo para obtener una medición con precisión. Se determina el error relativo de las mediciones, analizando posibles causas y soluciones.