Johannes Weitenberg
Research Subjects
Johannes Weitenberg has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Akira Ozawa
Max-Planck-Institut für Quantenoptik MPQ
7 shared publications - Fabian Schmid
ETH Zurich
6 shared publications - Thomas Udem
Max-Planck-Institut für Quantenoptik, Garching, Germany
6 shared publications - Jorge Moreno
Max-Planck-Institut für Quantenoptik MPQ
4 shared publications Theodor W. Hänsch
Max-Planck-Institut für Quantenoptik, Garching, Germany
4 shared publications- Vitaly Wirthl
Max Planck Institute of Quantum Optics
4 shared publications
Latest Publications
- 5 June 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (12) , 21846
Focal length of the thermal lens for unequal diameters of the heating and probing beams
We present a way to assign a focal length to a thermal lens that explicitly separates the material heating from the resulting lensing effect, enabling accurate modeling in the common scenarios of unequal heating (pump) and probing (signal) beam diameters, and a single astigmatic beam. The utility of this expression is demonstrated by applying it in two exemplary situations, representing these scenarios. In both cases, we find improved agreement of predicted beam parameters with experimental data when our formula is applied instead of the commonly used expression. We can accurately predict the output beam parameter of a solid-state laser resonator containing a thermal lens, while the conventional expression produces worse predictions than neglecting the thermal effect entirely in several configurations of our system. We describe our model and its limits in detail, offering a practical tool for the design of high–power lasers.
- 5 June 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (12) , 21846
Focal length of the thermal lens for unequal diameters of the heating and probing beams
We present a way to assign a focal length to a thermal lens that explicitly separates the material heating from the resulting lensing effect, enabling accurate modeling in the common scenarios of unequal heating (pump) and probing (signal) beam diameters, and a single astigmatic beam. The utility of this expression is demonstrated by applying it in two exemplary situations, representing these scenarios. In both cases, we find improved agreement of predicted beam parameters with experimental data when our formula is applied instead of the commonly used expression. We can accurately predict the output beam parameter of a solid-state laser resonator containing a thermal lens, while the conventional expression produces worse predictions than neglecting the thermal effect entirely in several configurations of our system. We describe our model and its limits in detail, offering a practical tool for the design of high–power lasers.
- Open Access
- 2 September 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 112 (3)
Towards trapping of hydrogen atoms for computable optical clock applications
Because of its simple structure, the hydrogen atom is often used as a testbed for quantum electrodynamics. Spectroscopy of trapped atomic samples can greatly improve the accuracy of these tests. Trapping atomic hydrogen in an optical dipole trap or an optical lattice has never been achieved. Only trapping in magnetic fields that lead to large Zeeman shifts has been demonstrated. Standard techniques of atomic physics are difficult to apply to atomic hydrogen. The small mass of the atom and the large photon energy of the 1-2 cooling transition significantly complicate Doppler cooling. This proposal introduces a photon recoil-assisted loading scheme that uses these properties to our advantage to load atomic hydrogen into an optical dipole trap without laser cooling. The magic wavelength (515 nm) for the 1-2 clock transition (1.3-Hz natural linewidth) is easily accessible with current laser technology. Since the 1-2 clock transition can be driven Doppler free, we do not require a very low temperature. Besides improving spectroscopy for fundamental science, such a system can also be used as a “computable” atomic clock that may one day justify the redefinition of the SI second in terms of the Rydberg constant.
- 2 September 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 112 (3)
Open AccessTowards trapping of hydrogen atoms for computable optical clock applications
Because of its simple structure, the hydrogen atom is often used as a testbed for quantum electrodynamics. Spectroscopy of trapped atomic samples can greatly improve the accuracy of these tests. Trapping atomic hydrogen in an optical dipole trap or an optical lattice has never been achieved. Only trapping in magnetic fields that lead to large Zeeman shifts has been demonstrated. Standard techniques of atomic physics are difficult to apply to atomic hydrogen. The small mass of the atom and the large photon energy of the 1-2 cooling transition significantly complicate Doppler cooling. This proposal introduces a photon recoil-assisted loading scheme that uses these properties to our advantage to load atomic hydrogen into an optical dipole trap without laser cooling. The magic wavelength (515 nm) for the 1-2 clock transition (1.3-Hz natural linewidth) is easily accessible with current laser technology. Since the 1-2 clock transition can be driven Doppler free, we do not require a very low temperature. Besides improving spectroscopy for fundamental science, such a system can also be used as a “computable” atomic clock that may one day justify the redefinition of the SI second in terms of the Rydberg constant.
- Open Access
- 21 April 2025
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 7 (2)
Noncollinear enhancement resonator with intrinsic pulse synchronization and alignment employing wedge mirrors
A noncollinear resonator with two beams circulating and intersecting in the focus allows resonator-assisted high-harmonic generation of high-power femtosecond pulses with efficient geometrical output coupling. However, the synchronization of the two pulses and alignment of the two beams is a challenge. We describe a resonator design employing wedge mirrors which avoids the need for separate mirrors for the two circulating beams, providing intrinsic synchronization and alignment. Transverse shifting of the wedge mirrors allows fine tuning the relative phase of the pulses, i.e., the interference pattern in the focus. We present the design of two noncollinear resonators at MPQ and at Fraunhofer ILT as well as the results of thorough characterization measurements on a noncollinear resonator with a low-power cw beam, demonstrating its versatility. We also include cylindrical mirrors into the resonator to adjust the ellipticity of the focus, which allows reducing cumulative plasma effects. Ellipticities ɛ > 3 are reached without compromising the resonator enhancement of >50. The MPQ resonator has been designed for an EUV frequency comb at 60.8 nm to perform high-precision spectroscopy on the 1 s − 2 s two-photon transition in H e + ions for a test of quantum electrodynamics. The ILT resonator has been designed in the framework of developing a VUV frequency comb at around 148 nm envisaged as driver for the low-lying isomeric nuclear transition in Th 229 (the so-called thorium isomer) as the presently only candidate for an ultra-high-precision nuclear frequency standard (“nuclear clock”).
- 21 April 2025
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 7 (2)
Open AccessNoncollinear enhancement resonator with intrinsic pulse synchronization and alignment employing wedge mirrors
A noncollinear resonator with two beams circulating and intersecting in the focus allows resonator-assisted high-harmonic generation of high-power femtosecond pulses with efficient geometrical output coupling. However, the synchronization of the two pulses and alignment of the two beams is a challenge. We describe a resonator design employing wedge mirrors which avoids the need for separate mirrors for the two circulating beams, providing intrinsic synchronization and alignment. Transverse shifting of the wedge mirrors allows fine tuning the relative phase of the pulses, i.e., the interference pattern in the focus. We present the design of two noncollinear resonators at MPQ and at Fraunhofer ILT as well as the results of thorough characterization measurements on a noncollinear resonator with a low-power cw beam, demonstrating its versatility. We also include cylindrical mirrors into the resonator to adjust the ellipticity of the focus, which allows reducing cumulative plasma effects. Ellipticities ɛ > 3 are reached without compromising the resonator enhancement of >50. The MPQ resonator has been designed for an EUV frequency comb at 60.8 nm to perform high-precision spectroscopy on the 1 s − 2 s two-photon transition in H e + ions for a test of quantum electrodynamics. The ILT resonator has been designed in the framework of developing a VUV frequency comb at around 148 nm envisaged as driver for the low-lying isomeric nuclear transition in Th 229 (the so-called thorium isomer) as the presently only candidate for an ultra-high-precision nuclear frequency standard (“nuclear clock”).
- 7 October 2024
- Published by Optica Publishing Group in Optical Materials Express
- Vol. 14 (11) , 2527-2541
Astigmatic thermal lensing due to surface bulging in Yb:KYW laser crystals
One of the sources of thermal lensing in crystals is surface bulging that results from an inhomogeneous temperature distribution. We investigate a thermal lens caused by surface bulging in an end-pumped Yb:KYW crystal, which serves as a gain medium in lasers and optical amplifiers. The surface profile of the pumped crystal is measured using a Fizeau-type interferometer and compared with a numerical simulation using a finite element method. The study reveals that due to anisotropic thermal expansion, the surface shape of the Yb:KYW crystal is anisotropic and the profile of the expansion is transversely displaced with respect to the pump beam profile which generates the temperature distribution. The observed surface bulging gives rise to aberrations and deflection of the transmitted beam. It was found that the surface bulging introduces astigmatism that is significantly larger than previously estimated [ Appl. Opt. 56, 3857 (2017)10.1364/AO.56.003857 ]. Our results allow the evaluation of the bulging contribution with improved accuracy. We show that these effects can be significant in certain designs of amplifiers and lasers.
- 7 October 2024
- Published by Optica Publishing Group in Optical Materials Express
- Vol. 14 (11) , 2527-2541
Astigmatic thermal lensing due to surface bulging in Yb:KYW laser crystals
One of the sources of thermal lensing in crystals is surface bulging that results from an inhomogeneous temperature distribution. We investigate a thermal lens caused by surface bulging in an end-pumped Yb:KYW crystal, which serves as a gain medium in lasers and optical amplifiers. The surface profile of the pumped crystal is measured using a Fizeau-type interferometer and compared with a numerical simulation using a finite element method. The study reveals that due to anisotropic thermal expansion, the surface shape of the Yb:KYW crystal is anisotropic and the profile of the expansion is transversely displaced with respect to the pump beam profile which generates the temperature distribution. The observed surface bulging gives rise to aberrations and deflection of the transmitted beam. It was found that the surface bulging introduces astigmatism that is significantly larger than previously estimated [ Appl. Opt. 56, 3857 (2017)10.1364/AO.56.003857 ]. Our results allow the evaluation of the bulging contribution with improved accuracy. We show that these effects can be significant in certain designs of amplifiers and lasers.
- Open Access
- 1 February 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (2)
An ultra-stable high-power optical frequency comb
Optical frequency combs are typically generated in the near-infrared wavelength range, where many mode-locked lasers operate. Nonlinear frequency conversion can then be used to extend optical frequency metrology to other spectral regions, such as the extreme ultraviolet (XUV). High-power frequency combs at the fundamental wavelength can efficiently drive nonlinear frequency conversions. Low phase noise is an important requirement because the frequency conversion process not only multiplies the carrier frequency but also the phase fluctuations. In this work, we have developed a low-noise frequency comb centered at 1030 nm with an average power of 230 W, a temporal pulse duration of 59 fs, and a peak power of 32 MW. One of the modes of the seed laser is phase-locked to a continuous wave reference laser stabilized to an ultra-stable high-finesse cavity. The residual integrated phase noise from 10 Hz to 10 MHz is 41 mrad, which is sufficiently low to address narrow transitions with kHz-level linewidths after the frequency conversion to XUV wavelengths.
- 1 February 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (2)
Open AccessAn ultra-stable high-power optical frequency comb
Optical frequency combs are typically generated in the near-infrared wavelength range, where many mode-locked lasers operate. Nonlinear frequency conversion can then be used to extend optical frequency metrology to other spectral regions, such as the extreme ultraviolet (XUV). High-power frequency combs at the fundamental wavelength can efficiently drive nonlinear frequency conversions. Low phase noise is an important requirement because the frequency conversion process not only multiplies the carrier frequency but also the phase fluctuations. In this work, we have developed a low-noise frequency comb centered at 1030 nm with an average power of 230 W, a temporal pulse duration of 59 fs, and a peak power of 32 MW. One of the modes of the seed laser is phase-locked to a continuous wave reference laser stabilized to an ultra-stable high-finesse cavity. The residual integrated phase noise from 10 Hz to 10 MHz is 41 mrad, which is sufficiently low to address narrow transitions with kHz-level linewidths after the frequency conversion to XUV wavelengths.
- 3 January 2024
- Published by Optica Publishing Group in Optica
- Vol. 11 (1) , 1-9
Low-repetition-rate optical frequency comb
Reducing the pulse repetition rate of an optical frequency comb increases the pulse energy for a given average power. This enhances the efficiency of nonlinear frequency conversion and it facilitates extending the accessible wavelength range, for example, into the extreme ultraviolet (XUV). The resulting spectrally dense frequency comb can still be used for precision spectroscopy of narrow atomic or molecular transitions. In this paper, we demonstrate a low-noise infrared frequency comb with a repetition rate as low as 40 kHz using a Yb:KYW mode-locked laser, pulse picking, and subsequent amplification. The frequency comb structure is confirmed by generating a beat note with a continuous wave reference laser. A comb mode is actively stabilized to the reference laser, and the integrated rms phase noise from 20 Hz to 20 kHz is measured to be 195 mrad.
- 3 January 2024
- Published by Optica Publishing Group in Optica
- Vol. 11 (1) , 1-9
Low-repetition-rate optical frequency comb
Reducing the pulse repetition rate of an optical frequency comb increases the pulse energy for a given average power. This enhances the efficiency of nonlinear frequency conversion and it facilitates extending the accessible wavelength range, for example, into the extreme ultraviolet (XUV). The resulting spectrally dense frequency comb can still be used for precision spectroscopy of narrow atomic or molecular transitions. In this paper, we demonstrate a low-noise infrared frequency comb with a repetition rate as low as 40 kHz using a Yb:KYW mode-locked laser, pulse picking, and subsequent amplification. The frequency comb structure is confirmed by generating a beat note with a continuous wave reference laser. A comb mode is actively stabilized to the reference laser, and the integrated rms phase noise from 20 Hz to 20 kHz is measured to be 195 mrad.
- Open Access
- 24 April 2023
- Published by Springer Nature in The European Physical Journal D
- Vol. 77 (4) , 1-13
Toward XUV frequency comb spectroscopy of the 1 S–2 S transition in $\hbox {He}^+$The energy levels of hydrogen-like atoms and ions are accurately described by bound-state quantum electrodynamics (QED). $$\hbox {He}^{+}$$ ions have a doubly charged nucleus, which enhances the higher-order QED contributions and makes them interesting for precise tests of QED. Systematic effects that currently dominate the uncertainty in hydrogen spectroscopy, such as the second-order Doppler shift and time-of-flight broadening, are largely suppressed by performing spectroscopy on trapped and cooled $$\hbox {He}^{+}$$ ions. Measuring a transition in $$\hbox {He}^{+}$$ will extend the test of QED beyond the long-studied hydrogen. In this article, we describe our progress toward precision spectroscopy of the 1 S–2 S two-photon transition in $$\hbox {He}^{+}$$ . The transition can be excited by radiation at a wavelength of 60.8 nm generated by a high-power infrared frequency comb using high-order harmonic generation (HHG). The $$\hbox {He}^{+}$$ ions are trapped in a Paul trap and sympathetically cooled with laser-cooled $$\hbox {Be}^{+}$$ ions. Our recently developed signal detection scheme based on secular-scan spectrometry is capable of detecting $$\hbox {He}^{+}$$ excitation with single-event sensitivity. Graphic- 24 April 2023
- Published by Springer Nature in The European Physical Journal D
- Vol. 77 (4) , 1-13
Open AccessToward XUV frequency comb spectroscopy of the 1 S–2 S transition in $\hbox {He}^+$The energy levels of hydrogen-like atoms and ions are accurately described by bound-state quantum electrodynamics (QED). $$\hbox {He}^{+}$$ ions have a doubly charged nucleus, which enhances the higher-order QED contributions and makes them interesting for precise tests of QED. Systematic effects that currently dominate the uncertainty in hydrogen spectroscopy, such as the second-order Doppler shift and time-of-flight broadening, are largely suppressed by performing spectroscopy on trapped and cooled $$\hbox {He}^{+}$$ ions. Measuring a transition in $$\hbox {He}^{+}$$ will extend the test of QED beyond the long-studied hydrogen. In this article, we describe our progress toward precision spectroscopy of the 1 S–2 S two-photon transition in $$\hbox {He}^{+}$$ . The transition can be excited by radiation at a wavelength of 60.8 nm generated by a high-power infrared frequency comb using high-order harmonic generation (HHG). The $$\hbox {He}^{+}$$ ions are trapped in a Paul trap and sympathetically cooled with laser-cooled $$\hbox {Be}^{+}$$ ions. Our recently developed signal detection scheme based on secular-scan spectrometry is capable of detecting $$\hbox {He}^{+}$$ excitation with single-event sensitivity. Graphic - Open Access
- 4 October 2022
- Published by American Physical Society (APS) in Physical Review A
- Vol. 106 (4) , L041101
Number-resolved detection of dark ions in Coulomb crystals
While it is straightforward to count laser-cooled trapped ions by fluorescence imaging, detecting the number of dark ions embedded and sympathetically cooled in a mixed ion crystal is more challenging. We demonstrate a method to track the number of dark ions in real time with single-particle sensitivity. This is achieved by observing discrete steps in the amount of fluorescence emitted from the coolant ions while exciting secular motional resonances of dark ions. By counting the number of fluorescence steps, we can identify the number of dark ions without calibration and without relying on any physical model of the motional excitation. We demonstrate the scheme by detecting and ions embedded in a ion Coulomb crystal in a linear radio-frequency trap. Our method allows observing the generation and destruction of individual ions simultaneously for different types of ions. Besides high-resolution spectroscopy of dark ions, another application is the detection of chemical reactions in real time with single-particle sensitivity. This is demonstrated in this Letter.- 4 October 2022
- Published by American Physical Society (APS) in Physical Review A
- Vol. 106 (4) , L041101
Open AccessNumber-resolved detection of dark ions in Coulomb crystals
While it is straightforward to count laser-cooled trapped ions by fluorescence imaging, detecting the number of dark ions embedded and sympathetically cooled in a mixed ion crystal is more challenging. We demonstrate a method to track the number of dark ions in real time with single-particle sensitivity. This is achieved by observing discrete steps in the amount of fluorescence emitted from the coolant ions while exciting secular motional resonances of dark ions. By counting the number of fluorescence steps, we can identify the number of dark ions without calibration and without relying on any physical model of the motional excitation. We demonstrate the scheme by detecting and ions embedded in a ion Coulomb crystal in a linear radio-frequency trap. Our method allows observing the generation and destruction of individual ions simultaneously for different types of ions. Besides high-resolution spectroscopy of dark ions, another application is the detection of chemical reactions in real time with single-particle sensitivity. This is demonstrated in this Letter. - 17 February 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (5) , 7340-7341
Improved active fiber-based retroreflector with intensity stabilization and a polarization monitor for the near UV: erratum
In Sec. 6 (polarization monitor) of our recent publication [ Opt. Express 29(5), 7024 (2021)10.1364/OE.417455 ], we assumed a small value of δ. This is however incorrect. The correct approximation for small β leads to the updated Eqs. (10)–(11), resulting in a corrected Fig. 12.
- 17 February 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (5) , 7340-7341
Improved active fiber-based retroreflector with intensity stabilization and a polarization monitor for the near UV: erratum
In Sec. 6 (polarization monitor) of our recent publication [ Opt. Express 29(5), 7024 (2021)10.1364/OE.417455 ], we assumed a small value of δ. This is however incorrect. The correct approximation for small β leads to the updated Eqs. (10)–(11), resulting in a corrected Fig. 12.
- Top Cited PapersOpen Access
- 15 April 2021
- Published by IOP Publishing in Quantum Science and Technology
- Vol. 6 (3) , 034002
Nuclear clocks for testing fundamental physics
The low-energy, long-lived isomer in 229Th, first studied in the 1970s as an exotic feature in nuclear physics, continues to inspire a multidisciplinary community of physicists. It has stimulated innovative ideas and studies that expand the understanding of atomic and nuclear structure of heavy elements and of the interaction of nuclei with bound electrons and coherent light. Using the nuclear resonance frequency, determined by the strong and electromagnetic interactions inside the nucleus, it is possible to build a highly precise nuclear clock that will be fundamentally different from all other atomic clocks based on resonant frequencies of the electron shell. The nuclear clock will open opportunities for highly sensitive tests of fundamental principles of physics, particularly in searches for violations of Einstein’s equivalence principle and for new particles and interactions beyond the standard model. It has been proposed to use the nuclear clock to search for variations of the electromagnetic and strong coupling constants and for dark matter searches. The 229Th nuclear optical clock still represents a major challenge in view of the tremendous gap of nearly 17 orders of magnitude between the present uncertainty in the nuclear transition frequency (about 0.2 eV, corresponding to ∼48 THz) and the natural linewidth (in the mHz range). Significant experimental progress has been achieved in recent years, which will be briefly reviewed. Moreover, a research strategy will be outlined to consolidate our present knowledge about essential 229mTh properties, to determine the nuclear transition frequency with laser spectroscopic precision, realize different types of nuclear clocks and apply them in precision frequency comparisons with optical atomic clocks to test fundamental physics. Two avenues will be discussed: laser-cooled trapped 229Th ions that allow experiments with complete control on the nucleus–electron interaction and minimal systematic frequency shifts, and Th-doped solids enabling experiments at high particle number and in different electronic environments.
- 15 April 2021
- Published by IOP Publishing in Quantum Science and Technology
- Vol. 6 (3) , 034002
Top Cited PapersOpen AccessNuclear clocks for testing fundamental physics
The low-energy, long-lived isomer in 229Th, first studied in the 1970s as an exotic feature in nuclear physics, continues to inspire a multidisciplinary community of physicists. It has stimulated innovative ideas and studies that expand the understanding of atomic and nuclear structure of heavy elements and of the interaction of nuclei with bound electrons and coherent light. Using the nuclear resonance frequency, determined by the strong and electromagnetic interactions inside the nucleus, it is possible to build a highly precise nuclear clock that will be fundamentally different from all other atomic clocks based on resonant frequencies of the electron shell. The nuclear clock will open opportunities for highly sensitive tests of fundamental principles of physics, particularly in searches for violations of Einstein’s equivalence principle and for new particles and interactions beyond the standard model. It has been proposed to use the nuclear clock to search for variations of the electromagnetic and strong coupling constants and for dark matter searches. The 229Th nuclear optical clock still represents a major challenge in view of the tremendous gap of nearly 17 orders of magnitude between the present uncertainty in the nuclear transition frequency (about 0.2 eV, corresponding to ∼48 THz) and the natural linewidth (in the mHz range). Significant experimental progress has been achieved in recent years, which will be briefly reviewed. Moreover, a research strategy will be outlined to consolidate our present knowledge about essential 229mTh properties, to determine the nuclear transition frequency with laser spectroscopic precision, realize different types of nuclear clocks and apply them in precision frequency comparisons with optical atomic clocks to test fundamental physics. Two avenues will be discussed: laser-cooled trapped 229Th ions that allow experiments with complete control on the nucleus–electron interaction and minimal systematic frequency shifts, and Th-doped solids enabling experiments at high particle number and in different electronic environments.