NZNavid Reza Zargari

Navid Reza Zargari

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Navid Reza Zargari has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Reduced Switch Count Power Cell for Regenerative Cascaded H-Bridge (CHB) Converter

    by Doho Kang, Sarah Badawi, Zhituo Ni, Anekant Jain, Mehdi Narimani, Navid Reza Zargari, Zhongyuan Cheng

    This paper proposes a new reduced switch-count power cell for a regenerative Cascaded H-Bridge (CHB) motor drive that reduces the number of switching devices per power cell from ten switches to six switches. The proposed power cell employs a Four-Switch Three Phase Inverter (FSTPI) at the front-end and a half-bridge inverter at the output of the power cell. The new configuration introduces four challenges: cell input current unbalance, input low order harmonics, DC-link voltage capacitor balancing, and switching harmonics. This paper analyzes and addresses these issues to ensure proper operation, control, and compliance with grid connection standards. The solutions are verified through simulation studies of a 3kV CHB motor drive and experimental validation with a single power cell setup. The results show the possibility of replacing the traditional power cell with a proposed cell, effectively reducing the required number of switches from ten to six.

  • Comparison of a 10 kV SiC Current Switch With two 6.5 kV Series Connected Si SGCTs for Medium Voltage Current Source Converter Applications

    by Sneha Narasimhan, Subhashish Bhattacharya, Navid R. Zargari

    Current source converters (CSCs) find extensive applications in medium voltage (MV) motor drive systems, ranging from 100 kWs to 10 s of MWs. In conventional CSC motor drives, Symmetric Gate-Commutated Thyristors (SGCTs) serve as reverse voltage-blocking (RVB) switches, referred to as current switches (CS). However, these SGCT devices operate at relatively low switching frequencies (420-720 Hz), leading to larger passive components and reduced system efficiencies. Furthermore, these devices must be connected in series to achieve the necessary line-line voltage ratings of 4.16 kV for 4.16 kV-rated motors. The emergence of Silicon Carbide (SiC)-based devices has revolutionized CSC technology by enabling high switching frequency, reducing the size of the passives, and the need for a high device count. This paper presents a comparative study between a single 10 kV SiC CS and two series-connected 6.5 kV SGCTs for MV CSC applications with a line-to-line voltage rating of 4.16 kV. The analysis encompasses device sizing, passive component selection and sizing, and the evaluation of system losses, including converter losses and passive component losses. The results highlight the advantages of the SiC-based solution, which offers increased power density, improved waveform quality with reduced total harmonic distortion (THD), enhanced overall system efficiency, and higher thermal limits. Finally, experimental results with the 10 kV XHV-9 module are presented.


  • H-Type Five-Level Current Source Inverter

    by Zijian Wang, Qiang Wei, Navid R. Zargari

    Conventional five-level current source inverters (CSIs), suffer from current imbalance issues, necessitating complex balancing schemes. The emerging five-level CSIs, such as X-type and Γ-type CSIs, can achieve inherent current balance, thereby eliminating the need for additional balancing schemes. However, they require the use of large DC inductors, resulting in large size and weight, high cost, and low efficiency. To address this challenge, an H-type five-level CSI is proposed in this work. It retains inherent current balancing while simultaneously achieving minimized DC inductors throughout its full operating range. Its performance is validated through laboratory-scale experiments.


  • An Overview of Advancements in Multimotor Drives: Structural Diversity, Advanced Control, Specific Technical Challenges, and Solutions

    by Chao Gong, Yunwei Ryan Li, Navid R. Zargari

    Multimotor drives have become increasingly important in modern industrial applications due to their ability to provide superior performance, efficiency, and flexibility compared to single-motor systems. Hence, this article presents an overview of recent advancements in multimotor drives, focusing on three main areas: structural diversity, advanced control, and emerging challenges and solutions. First, the various structural configurations of multimotor drives are summarized, which include parallel, cascaded, and hybrid configurations. The features as well as component motors and converters of each configuration are discussed, along with the selection rules of a particular configuration for a given application. Second, from the perspective of different performance requirements, the advanced control technologies used for multimotor drives are discussed. Then, this article highlights the technical challenges associated with multimotor drives, including coordination control, mutual interference, communication, interdependent fault diagnosis, and power quality. Meanwhile, viable solutions to these challenges are summarized. Finally, a discussion of the future directions and opportunities for further research and development in the field of multimotor drives is presented. Through this article, scholars and engineers can gain a comprehensive understanding of current and future developments in multimotor drives, contributing to continued research in this field and facilitating successful integration into various applications.


  • Open Access

    A New Approach to Reduce DC-Bus Capacitance in Regenerative CHB Motor Drives

    by Ahmed Abuelnaga, Zhituo Ni, Sarah Badawi, Mehdi Narimani, Navid R. Zargari

    The cascaded H-bridge (CHB) converters with diode-front-end (DFE) structure have been widely adopted in non-regenerative high-power medium-voltage motor drives. In order to allow regenerative capability, the diode-front end (DFE) in each power cell can be replaced by an IGBT-based active-front-end (AFE) operating as a PWM rectifier. Due to the inherent instantaneous power unbalance in the AFE-based CHB power cells, the DC-bus capacitance needs to be increased to reduce DC-bus voltage ripples. To reduce the DC-bus capacitance, control degrees of freedom provided by the PWM rectifiers can be exploited to mitigate the DC-bus voltage ripples. This paper proposes a new controller for regenerative CHB converters to perform DC-bus voltage control and ripple mitigation while maintaining high dynamic performance and canceling low order harmonics at the grid side to meet the grid standards. The effectiveness of the proposed control scheme is validated experimentally on a seven-level regenerative CHB drive.


  • A New Active Front-End Control for Regenerative Cascaded H-Bridge Motor Drives With Filter- Less Interfacing Capability

    by Ahmed H. Abuelnaga, Zhituo Ni, Sarah Badawi, Mehdi Narimani, Ahmed Sayed-Ahmed, Navid R. Zargari

    This article proposes a new active-front-end (AFE) control method for regenerative cascaded H-bridge (CHB) motor drives. Conventional CHB converters have dominated the market for the medium-voltage industrial motor drives. However, conventional CHB converters cannot provide regenerative capability. To enable regeneration; diode-front-ends in power cells are replaced with insulated-gate bipolar transistor (IGBT)-based pulsewidth modulation (PWM) AFEs. Despite the appealing dynamic performance of PWM AFEs, their integration to the CHB converters is not optimal. First, they introduce more semiconductor losses due to the high-frequency switching. Second, they introduce switching harmonics that are not cancelled by phase-shifting transformers. Therefore, they require additional harmonic filtering solutions to comply with grid harmonic standards. To resolve these challenges, this article proposes a new AFE control for regenerative CHB converters based on fundamental frequency switching (FFE) to reduce switching frequency and thus power losses. The operation of FFEs at nominal and sag voltage conditions is presented, in addition to the capability of filter-less interfacing to the transformer. Finally, the performance of the proposed control is validated experimentally on a seven-level regenerative CHB drive.


  • Control of Regenerative CHB Motor Drives at Fundamental Switching Frequency

    by Zhituo Ni, Ahmed H. Abuelnaga, Sarah Badawi, Shaoyi Yuan, Yue Pan, Mehdi Narimani, Zhongyuan Cheng, Navid R. Zargari

    To handle the high-power regeneration power in coal and mine industry applications, the regenerative version of the cascaded H-bridge (CHB) drives is made possible by replacing the diode-front-end rectifier with a three-phase IGBT-based active-front-end (AFE) rectifier in each power cell. However, the IGBT switching devices introduce extra switching losses to the system that must be properly handled due to the thermal constraints in high power medium voltage drive applications. In this article, a novel fundamental switching frequency control strategy is proposed for the AFEs in the regenerative CHB drive. With the proposed control strategy, the main harmonic contents generated by the AFEs are well-reshaped at a low-order harmonics range which can be further eliminated by the existing front-end phase-shifting transformer. This allows accomplishing the meeting of the IEEE std 519-2014 at the fundamental switching frequency f sw = 60. Moreover, with the proposed switching pattern, IGBTs can be turned off at zero current and therefore it can reduce switching losses simultaneously. The feasibility of the proposed control strategy is verified by experimental results on a seven-level regenerative CHB drive, which can be extended to regenerative CHB drives with any voltage levels.


  • A New Low Switching Frequency Control of Regenerative CHB Drive With Low-Voltage Ride-Through Capability

    by Zhituo Ni, Ahmed H. Abuelnaga, Sarah Badawi, Shaoyi Yuan, Mehdi Narimani, Ahmed Sayed-Ahmed, Zhongyuan Cheng, Navid R. Zargari

    In conventional medium-voltage high-power cascaded H bridge (CHB) drive, a three-phase rectifier is adopted in each power cell to provide isolated dc bus voltage for the output H bridge. This limits the application of the conventional CHB drive where regeneration capability is desired. The regenerative CHB drive can be made possible by replacing the diode rectifier with a three-phase IGBT-based active-front-end (AFE) rectifier in each power cell. However, due to thermal constraints in the high-power medium voltage drives, the first challenge of the regenerative CHB drive is to deal with the extra switching losses introduced by the IGBT devices. Another challenge of the grid-tied regenerative CHB drive is to handle the low voltage sags in the power grid without triggering unnecessary downtime in transients. In this paper, a novel low-switching frequency control strategy is proposed for the AFEs in the regenerative CHB drive with low-voltage ride-through capability. The main harmonic contents generated by the AFEs with the proposed control strategy can be eliminated by the existing phase-shifting transformer in the CHB drives. This allows meeting with IEEE std 519-2014 requirement with a 60 Hz switching frequency to minimize the extra introduced switching losses in steady-state. Moreover, low voltage ride-through capability is integrated into the proposed control scheme with reduced current sensor count. Accompanied with videos, the experiments on a seven-level regenerative CHB drive are implemented to validate the feasibility of the proposed control scheme, which can be extended to regenerative CHB drives with any voltage levels.


  • Open Access

    Review of Reduced Switch-Count Power Cells for Regenerative Cascaded H-Bridge Motor Drives

    by Doho Kang, Sarah Badawi, Zhituo Ni, Ahmed H. Abuelnaga, Mehdi Narimani, Navid R. Zargari

    Cascaded H-Bridge (CHB) topology is one of the attractive topologies in high-power medium-voltage motor drive applications due to its modularity and scalability. Research in high power regenerative motor drives has gained significant attention with the increasing demand for efficient energy use. In a cascaded H-Bridge (CHB) converter, the regenerative capability can be introduced by replacing diode front end (DFE) with active front end (AFE) topologies. However, this results in a huge increase in the number of power semiconductors, gate drivers, and heat sink size and thus increases the overall size and cost of the regenerative CHB motor drives. To overcome the aforementioned challenges, different power cell designs have been introduced to reduce the switch count, allowing the design of more suitable-sized and more economical drives. This paper comprehensively reviews the reduced switch-count power cell designs, including single-phase and three-phase grid connections. Each reduced switch-count cell design is analyzed, and its advantages and disadvantages are studied in detail. The challenges that arise with each design and the method to address the challenges are discussed.