Tamara Braunschmid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tamara Braunschmid has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Alexandra Graf
Medical University of Vienna
2 shared publications - Anton Stift
Division of General Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
2 shared publications Bernhard Dauser
Department of Surgery, St. John of God Hospital, Vienna, Austria
2 shared publications- Jagdeep Singh Bhangu
Department of General Surgery, Medical University of Vienna, Austria; Department of Surgery, Klinik Floridsdorf, Wiener Gesundheitsverbund, Austria
2 shared publications Martina Mittlböck
Center for Medical Statistics, Informatics, and Intelligent Systems, Medical University of Vienna, Vienna, Austria
2 shared publicationsStefan Riss
Department of General Surgery, Medical University of Vienna, Austria
2 shared publications
Latest Publications
- Open Access
- 3 November 2023
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 110 (2) , 884-890
Prevalence and long-term implications of preoperative anemia in patients undergoing elective general surgery: a retrospective cohort study at a university hospital
Objective: The aim of this retrospective study was to assess the prevalence of anaemia in a cohort of patients undergoing elective general surgery at a university hospital. Furthermore, the authors investigated the influence of anaemia on short-term and long-term postoperative outcome. Background: Awareness of the negative impact of preoperative anaemia on perioperative morbidity and mortality is rising. Anaemia is a potentially modifiable factor, and its therapy might improve patient outcome in elective surgery. Nevertheless, patients with preoperative anaemia frequently undergo elective surgery without receiving adequate preoperative treatment. Methods: In this single-centre cohort study, the authors analyzed 6908 adult patients who underwent elective general surgery. Patients undergoing day-clinic surgery were excluded. In all patients, preoperative haemoglobin concentration and haematocrit was available. Results: Of all patients analyzed, 32.9% were anaemic (21.0% mild, 11.8% moderate, 1.1% severe). Median time to last follow-up was 5.2 years. During the whole study period, 27.1% of patients died (1.2% died during the hospital stay); median time to death was 1.3 years. Patients with preoperative anaemia had significantly higher mortality rates (PPP<0.001). Conclusion: This retrospective single-centre analysis confirmed that preoperative anaemia is common, and is a significant risk factor for unfavourable postoperative outcome. As anaemia is a modifiable risk factor, the implementation of a patient blood management concept is crucial to reduce detrimental postoperative events associated with anaemia.
- 3 November 2023
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 110 (2) , 884-890
Open AccessPrevalence and long-term implications of preoperative anemia in patients undergoing elective general surgery: a retrospective cohort study at a university hospital
Objective: The aim of this retrospective study was to assess the prevalence of anaemia in a cohort of patients undergoing elective general surgery at a university hospital. Furthermore, the authors investigated the influence of anaemia on short-term and long-term postoperative outcome. Background: Awareness of the negative impact of preoperative anaemia on perioperative morbidity and mortality is rising. Anaemia is a potentially modifiable factor, and its therapy might improve patient outcome in elective surgery. Nevertheless, patients with preoperative anaemia frequently undergo elective surgery without receiving adequate preoperative treatment. Methods: In this single-centre cohort study, the authors analyzed 6908 adult patients who underwent elective general surgery. Patients undergoing day-clinic surgery were excluded. In all patients, preoperative haemoglobin concentration and haematocrit was available. Results: Of all patients analyzed, 32.9% were anaemic (21.0% mild, 11.8% moderate, 1.1% severe). Median time to last follow-up was 5.2 years. During the whole study period, 27.1% of patients died (1.2% died during the hospital stay); median time to death was 1.3 years. Patients with preoperative anaemia had significantly higher mortality rates (PPP<0.001). Conclusion: This retrospective single-centre analysis confirmed that preoperative anaemia is common, and is a significant risk factor for unfavourable postoperative outcome. As anaemia is a modifiable risk factor, the implementation of a patient blood management concept is crucial to reduce detrimental postoperative events associated with anaemia.
- 15 August 2018
- Published by Wiley in Annals of the New York Academy of Sciences
- Vol. 1434 (1) , 46-53
TP53 is not a prognostic marker—clinical consequences of a generally disregarded fact
Technological progress within the last 15–20 years has significantly increased our knowledge about the molecular basis of cancer development, tumor progression, and treatment response. As a consequence, a vast number of biomarkers have been proposed, but only a small fraction of them have found their way into clinical use. The aim of this paper is to describe the specific demands a clinically relevant biomarker should meet and how biomarkers can be tested stepwise. We name this procedure the “triple‐R principle”: robustness, reproducibility, and relevance. The usefulness of this principle is illustrated with the marker TP53. Since it is mutated in a broad spectrum of cancer entities, TP53 can be considered a very promising marker. Thus, TP53 has been studied in detail but there is still no explicit consensus about its clinical value. By considering our own experience and reviewing the literature, we demonstrate that a major problem of current biomarker research is disregard of whether the biomarker is prognostic or predictive. As an example, it is demonstrated that TP53 is not a prognostic marker, but rather a purely predictive marker, and that disregard of this fact has made this otherwise strong biomarker appear as not being clinically useful so far.
- 15 August 2018
- Published by Wiley in Annals of the New York Academy of Sciences
- Vol. 1434 (1) , 46-53
TP53 is not a prognostic marker—clinical consequences of a generally disregarded fact
Technological progress within the last 15–20 years has significantly increased our knowledge about the molecular basis of cancer development, tumor progression, and treatment response. As a consequence, a vast number of biomarkers have been proposed, but only a small fraction of them have found their way into clinical use. The aim of this paper is to describe the specific demands a clinically relevant biomarker should meet and how biomarkers can be tested stepwise. We name this procedure the “triple‐R principle”: robustness, reproducibility, and relevance. The usefulness of this principle is illustrated with the marker TP53. Since it is mutated in a broad spectrum of cancer entities, TP53 can be considered a very promising marker. Thus, TP53 has been studied in detail but there is still no explicit consensus about its clinical value. By considering our own experience and reviewing the literature, we demonstrate that a major problem of current biomarker research is disregard of whether the biomarker is prognostic or predictive. As an example, it is demonstrated that TP53 is not a prognostic marker, but rather a purely predictive marker, and that disregard of this fact has made this otherwise strong biomarker appear as not being clinically useful so far.
- 1 December 2017
- Published by Elsevier in Surgical Oncology
- Vol. 26 (4) , 395-401
Circulating cell-free DNA in plasma of colorectal cancer patients - A potential biomarker for tumor burden
- 1 December 2017
- Published by Elsevier in Surgical Oncology
- Vol. 26 (4) , 395-401
Circulating cell-free DNA in plasma of colorectal cancer patients - A potential biomarker for tumor burden
- Open Access
- 20 June 2017
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (12) , 5318-5326
Influence of multiple stapler firings used for rectal division on colorectal anastomotic leak rate
Background Anastomotic leakage following colorectal resection remains one of the most significant complications with relevant morbidity and mortality. There is evidence that a higher number of stapler firings for rectal division can affect the leak rate in double stapling anastomosis. However, there are no data concerning compression anastomosis. We present our institutional experience addressing this issue. Design This is a retrospective review of a prospective institutional database of patients undergoing colonic and rectal resection for benign and malignant indications between January 2008 and December 2014 at the surgical department of the St. John of God Hospital, Vienna. Inclusion criteria were rectal division with linear stapling devices and construction of anastomosis to the rectal stump using a circular stapler or compression device. Results Three hundred eighty two (196 female; 51.3%) patients were included. Mean age was 65.8 years (range: 18–95) Indications for the operation included diverticular disease (44.8%), colorectal carcinoma (51.6%), inflammatory bowel disease (1.8%), and adenoma (1.8%). A laparoscopic approach was employed in 334 cases (87.4%); in 170 patients (44.9%), a compression anastomosis was created. One, two, and three or more stapler cartridges were used for rectal division in 58.4, 33.5, and 8.1%, respectively. Male gender, neoadjuvant therapy, rectal cancer as an underlying disease, laparoscopic surgical approach, and duration of operation longer than 200 min are leading causes for the usage of more than one stapler cartridge. Overall leak rate was 4.7% (18/382). The only factor associated with the occurrence of leakage was the use of three or more stapler cartridges for the closure of the rectal stump (p = 0.002). Conclusion Our data support that multiple stapler firings for rectal division following colorectal resection has a major impact on anastomotic leak rate. Especially in laparoscopic surgery efforts should be made to minimize the number of stapler cartridges used.
- 20 June 2017
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (12) , 5318-5326
Open AccessInfluence of multiple stapler firings used for rectal division on colorectal anastomotic leak rate
Background Anastomotic leakage following colorectal resection remains one of the most significant complications with relevant morbidity and mortality. There is evidence that a higher number of stapler firings for rectal division can affect the leak rate in double stapling anastomosis. However, there are no data concerning compression anastomosis. We present our institutional experience addressing this issue. Design This is a retrospective review of a prospective institutional database of patients undergoing colonic and rectal resection for benign and malignant indications between January 2008 and December 2014 at the surgical department of the St. John of God Hospital, Vienna. Inclusion criteria were rectal division with linear stapling devices and construction of anastomosis to the rectal stump using a circular stapler or compression device. Results Three hundred eighty two (196 female; 51.3%) patients were included. Mean age was 65.8 years (range: 18–95) Indications for the operation included diverticular disease (44.8%), colorectal carcinoma (51.6%), inflammatory bowel disease (1.8%), and adenoma (1.8%). A laparoscopic approach was employed in 334 cases (87.4%); in 170 patients (44.9%), a compression anastomosis was created. One, two, and three or more stapler cartridges were used for rectal division in 58.4, 33.5, and 8.1%, respectively. Male gender, neoadjuvant therapy, rectal cancer as an underlying disease, laparoscopic surgical approach, and duration of operation longer than 200 min are leading causes for the usage of more than one stapler cartridge. Overall leak rate was 4.7% (18/382). The only factor associated with the occurrence of leakage was the use of three or more stapler cartridges for the closure of the rectal stump (p = 0.002). Conclusion Our data support that multiple stapler firings for rectal division following colorectal resection has a major impact on anastomotic leak rate. Especially in laparoscopic surgery efforts should be made to minimize the number of stapler cartridges used.
- Open Access
- 16 September 2016
- Published by Impact Journals, LLC in Oncotarget
- Vol. 7 (45) , 73800-73816
Epithelial splicing regulatory protein 1 and 2 paralogues correlate with splice signatures and favorable outcome in human colorectal cancer
Epithelial splicing regulatory protein 1 and 2 paralogues correlate with splice signatures and favorable outcome in human colorectal cancer
- 16 September 2016
- Published by Impact Journals, LLC in Oncotarget
- Vol. 7 (45) , 73800-73816
Open AccessEpithelial splicing regulatory protein 1 and 2 paralogues correlate with splice signatures and favorable outcome in human colorectal cancer
Epithelial splicing regulatory protein 1 and 2 paralogues correlate with splice signatures and favorable outcome in human colorectal cancer
- 1 July 2015
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 19, 42-45
Constipation is not associated with diverticular disease – Analysis of 976 patients
In the light of controversial data in the literature, the present study was designed to evaluate potential associations between colonic diverticular disease, constipation and quality of life. We prospectively enrolled 976 consecutive patients, who participated in the nationwide colorectal cancer screening program in four medical centers between 2008 and 2009. All patients underwent full colonoscopy and completed a standardized questionnaire. The severity of constipation was assessed by the validated Wexner constipation score. Quality of Life (QOL) was evaluated by the SF-12 health score. The median age was 62 years (range 22-90) and the male to female ratio was 1:1. Colonic diverticular disease was found in 290 participants (30%). Age, body mass index and diabetes mellitus were significantly associated with the presence of diverticular disease (p < 0.0001, p = 0.0007 and p = 0.0178). The median constipation score in patients with diverticular disease was 3 (range 0-18), and comparable to patients without diverticula (p = 0.1073). The physical component summary of the SF-12 was significantly reduced in patients with diverticular disease (p = 0.0038). This large population based study revealed no association between colonic diverticular disease and constipation. Notably, the presence of diverticular disease significantly impacts quality of life.
- 1 July 2015
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 19, 42-45
Constipation is not associated with diverticular disease – Analysis of 976 patients
In the light of controversial data in the literature, the present study was designed to evaluate potential associations between colonic diverticular disease, constipation and quality of life. We prospectively enrolled 976 consecutive patients, who participated in the nationwide colorectal cancer screening program in four medical centers between 2008 and 2009. All patients underwent full colonoscopy and completed a standardized questionnaire. The severity of constipation was assessed by the validated Wexner constipation score. Quality of Life (QOL) was evaluated by the SF-12 health score. The median age was 62 years (range 22-90) and the male to female ratio was 1:1. Colonic diverticular disease was found in 290 participants (30%). Age, body mass index and diabetes mellitus were significantly associated with the presence of diverticular disease (p < 0.0001, p = 0.0007 and p = 0.0178). The median constipation score in patients with diverticular disease was 3 (range 0-18), and comparable to patients without diverticula (p = 0.1073). The physical component summary of the SF-12 was significantly reduced in patients with diverticular disease (p = 0.0038). This large population based study revealed no association between colonic diverticular disease and constipation. Notably, the presence of diverticular disease significantly impacts quality of life.
- 15 August 2013
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 398 (7) , 957-964
Anastomotic leakage after low anterior resection for rectal cancer: comparison of stapled versus compression anastomosis
Surgical technique and perioperative management in rectal cancer surgery have been substantially improved and standardized during the last decades. However, anastomotic leakage following low anterior resection still is a significant problem. Based on animal experimental data of improved healing of compression anastomosis, we hypothesized that a compression anastomotic device might improve healing rates of the highest-risk anastomoses. All low anterior resections for rectal cancer performed or directly supervised by the senior author between January 2004 and June 2012 were analyzed. Only patients with a stapled or compression anastomosis located within 6 cm from the anal verge were included. Until December 2008, circular staplers were employed, while since January 2009, a novel compression anastomotic device was used for rectal reconstruction exclusively. Out of 197 patients operated for rectal cancer, a total of 96 (34 females, 35.4 %) fulfilled inclusion criteria. Fifty-eight (60.4 %) were reconstructed with circular staplers and 38 (39.6 %) using a compression anastomotic device. Significantly, more laparoscopic procedures were recorded in the compression anastomosis group, but distribution of gender, age, body mass index, American Society of Anaesthesiologists score, rate of preoperative radiotherapy, tumor staging, or stoma diversion rate were similar. Anastomotic leakage was observed in seven cases (7/58, 12.1 %) in the stapled and twice (2/38, 5.3 %) in the compression anastomosis group (p = 0.26). In this series, rectal reconstruction following low anterior resection using a novel compression anastomotic device was safe and (at least) equally effective compared to traditional circular staplers concerning leak rate.
- 15 August 2013
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 398 (7) , 957-964
Anastomotic leakage after low anterior resection for rectal cancer: comparison of stapled versus compression anastomosis
Surgical technique and perioperative management in rectal cancer surgery have been substantially improved and standardized during the last decades. However, anastomotic leakage following low anterior resection still is a significant problem. Based on animal experimental data of improved healing of compression anastomosis, we hypothesized that a compression anastomotic device might improve healing rates of the highest-risk anastomoses. All low anterior resections for rectal cancer performed or directly supervised by the senior author between January 2004 and June 2012 were analyzed. Only patients with a stapled or compression anastomosis located within 6 cm from the anal verge were included. Until December 2008, circular staplers were employed, while since January 2009, a novel compression anastomotic device was used for rectal reconstruction exclusively. Out of 197 patients operated for rectal cancer, a total of 96 (34 females, 35.4 %) fulfilled inclusion criteria. Fifty-eight (60.4 %) were reconstructed with circular staplers and 38 (39.6 %) using a compression anastomotic device. Significantly, more laparoscopic procedures were recorded in the compression anastomosis group, but distribution of gender, age, body mass index, American Society of Anaesthesiologists score, rate of preoperative radiotherapy, tumor staging, or stoma diversion rate were similar. Anastomotic leakage was observed in seven cases (7/58, 12.1 %) in the stapled and twice (2/38, 5.3 %) in the compression anastomosis group (p = 0.26). In this series, rectal reconstruction following low anterior resection using a novel compression anastomotic device was safe and (at least) equally effective compared to traditional circular staplers concerning leak rate.