Jérémie Dabin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jérémie Dabin has a total of 315 co-authors. Here are the top co-authors by number of shared publications:
Lara Struelens
SCK-CEN, Belgian Nuclear Research Centre, Belgium
9 shared publicationsCarlo Maccia
Centre d’Assurance de qualité des Applications Technologiques dans le domaine de la Santé (CAATS), Sèvres, France
6 shared publicationsFilip Vanhavere
Radiation Protection, Dosimetry and Calibration, Belgian Nuclear Research Centre, Mol, Flanders, BELGIUM
6 shared publications- Jad Farah
Institut de Radioprotection et de Sûreté Nucléaire (IRSN), BP17, 92262 Fontenay-aux-Roses Cedex, France
6 shared publications - Renata Kopeć
Institute of Nuclear Physics Polish Academy of Science, Radzikowskiego 152, Krakow, 31-342, POLAND
6 shared publications Aoife Gallagher
Department of Medical Physics, University Hospital Limerick, Limerick, Ireland
5 shared publications
Latest Publications
- 7 July 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (3) , 031504
Assessment of the extremity exposure during preparation and administration of 177 Lu – results of a multi-center study
Despite the increased use of 177 Lu in nuclear medicine (NM) over the last 10 years, the knowledge of the actual exposure of the extremities due to manipulation of this pharmaceutical is limited. The purpose of this study is to assess the extremity dose during the preparation and administration of 177 Lu-labelled radiopharmaceuticals in a wide range of NM practices. Workers in 10 NM centres throughout Europe wore a ring dosimeter on the base of the index finger of the non-dominant hand during preparation and/or administration of 177 Lu-labelled radiopharmaceuticals. Information on manipulated activity, tasks performed and protection measures was collected to allow sub-analyses. The median ring dose per monitoring interval was 0.16 mSv, with a maximum of 2.27 mSv in one month. The median normalised dose amounted 3.5 µ Sv GBq −1 (range 0.5–525). The highest monthly doses were found for workers involved in preparation of the pharmaceutical. The workers performing manual administrations (6.5 µ Sv GBq −1 ) showed higher normalised ring doses than those using the gravity method (3.5 µ Sv GBq −1 ) or a syringe pump (1.0 µ Sv GBq −1 ). Explanations for the wide range of normalised ring doses may be found in the different techniques applied in this study and the differences in minimum reportable doses of the dosimeters. When the data is extrapolated using a fingertip to ring dose ratio of 5, an annual fingertip dose of 1–136 mSv is found, with a median fingertip dose of 10 mSv per year. Extremity exposure during 177 Lu handling remained well below dose limits. The highest normalised doses occurred during preparation and manual administration. Overall, this investigation shows doses remain low when appropriate radiation protection measures (e.g. shielding and minimising time at short distance) are being applied.
- 7 July 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (3) , 031504
Assessment of the extremity exposure during preparation and administration of 177 Lu – results of a multi-center study
Despite the increased use of 177 Lu in nuclear medicine (NM) over the last 10 years, the knowledge of the actual exposure of the extremities due to manipulation of this pharmaceutical is limited. The purpose of this study is to assess the extremity dose during the preparation and administration of 177 Lu-labelled radiopharmaceuticals in a wide range of NM practices. Workers in 10 NM centres throughout Europe wore a ring dosimeter on the base of the index finger of the non-dominant hand during preparation and/or administration of 177 Lu-labelled radiopharmaceuticals. Information on manipulated activity, tasks performed and protection measures was collected to allow sub-analyses. The median ring dose per monitoring interval was 0.16 mSv, with a maximum of 2.27 mSv in one month. The median normalised dose amounted 3.5 µ Sv GBq −1 (range 0.5–525). The highest monthly doses were found for workers involved in preparation of the pharmaceutical. The workers performing manual administrations (6.5 µ Sv GBq −1 ) showed higher normalised ring doses than those using the gravity method (3.5 µ Sv GBq −1 ) or a syringe pump (1.0 µ Sv GBq −1 ). Explanations for the wide range of normalised ring doses may be found in the different techniques applied in this study and the differences in minimum reportable doses of the dosimeters. When the data is extrapolated using a fingertip to ring dose ratio of 5, an annual fingertip dose of 1–136 mSv is found, with a median fingertip dose of 10 mSv per year. Extremity exposure during 177 Lu handling remained well below dose limits. The highest normalised doses occurred during preparation and manual administration. Overall, this investigation shows doses remain low when appropriate radiation protection measures (e.g. shielding and minimising time at short distance) are being applied.
- Open Access
- 3 March 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (2)
HARMONIC organ dose calculation framework for cardiac fluoroscopy
The HARMONIC study (health effects of cardiac fluoroscopy and modern radiotherapy in paediatrics) aims, among other objectives, to investigate the relationship between ionising radiation and cancer incidence in children treated by cardiac fluoroscopy procedures (HARMONIC-Cardio). This requires estimation of organ doses for a large patient cohort. A framework for accurate dose calculation was developed, and used to create a software tool for rapid dose estimates. Organ doses were calculated with MCNP6.2 Monte Carlo particle transport code. Eight realistic, anthropomorphic phantoms were used representing newborn, 1, 5, 10, 15 year old and adult patients. Only male phantoms were used for patients younger than 15; male and female for older patients). A large range of technical parameters was covered in the simulations, including 11 primary beam angles and seven secondary angles, four levels of beam filtration, three tube voltages and three field sizes. The absorbed dose was computed for 32 organs and tissues. The calculated organ doses were normalised to the air kerma-area product (PKA), a common modality-specific dose index, resulting in PKA-to-organ-dose conversion coefficients. These coefficients were extended by interpolation. Organ dose conversion coefficients were calculated for 22,176 exposure configurations and interpolated to a total of 2,667,600. The coefficients for 15 organs of interest for radiation protection and effective dose were embedded in HARMONIC-CardioDose: a software tool that enables users to estimate organ doses for virtually any exposure scenario within the simulation range. The program is in the form of a Python script or an executable file, and uses a simple Excel document for inputting technical parameters necessary for calculations. HARMONIC-CardioDose is a validated software tool for rapid estimate of organ doses for paediatric and adult patients undergoing interventional cardiology procedures. The tool is freely available to the medical and research community for supporting patient dosimetry
- 3 March 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (2)
Open AccessHARMONIC organ dose calculation framework for cardiac fluoroscopy
The HARMONIC study (health effects of cardiac fluoroscopy and modern radiotherapy in paediatrics) aims, among other objectives, to investigate the relationship between ionising radiation and cancer incidence in children treated by cardiac fluoroscopy procedures (HARMONIC-Cardio). This requires estimation of organ doses for a large patient cohort. A framework for accurate dose calculation was developed, and used to create a software tool for rapid dose estimates. Organ doses were calculated with MCNP6.2 Monte Carlo particle transport code. Eight realistic, anthropomorphic phantoms were used representing newborn, 1, 5, 10, 15 year old and adult patients. Only male phantoms were used for patients younger than 15; male and female for older patients). A large range of technical parameters was covered in the simulations, including 11 primary beam angles and seven secondary angles, four levels of beam filtration, three tube voltages and three field sizes. The absorbed dose was computed for 32 organs and tissues. The calculated organ doses were normalised to the air kerma-area product (PKA), a common modality-specific dose index, resulting in PKA-to-organ-dose conversion coefficients. These coefficients were extended by interpolation. Organ dose conversion coefficients were calculated for 22,176 exposure configurations and interpolated to a total of 2,667,600. The coefficients for 15 organs of interest for radiation protection and effective dose were embedded in HARMONIC-CardioDose: a software tool that enables users to estimate organ doses for virtually any exposure scenario within the simulation range. The program is in the form of a Python script or an executable file, and uses a simple Excel document for inputting technical parameters necessary for calculations. HARMONIC-CardioDose is a validated software tool for rapid estimate of organ doses for paediatric and adult patients undergoing interventional cardiology procedures. The tool is freely available to the medical and research community for supporting patient dosimetry
- 1 December 2025
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 45 (4) , 041519
Interactive posture program: a software platform for using the realistic anthropomorphic flexible phantom family in computational dosimetry applications
Boundary-representation (B-Rep) computational phantoms (CPs) offer high flexibility and anatomical accuracy, making them valuable tools in dosimetry and medical imaging simulations. However, their complexity and the need for expertise in graphic modelling limit their accessibility and adoption. Moreover, most Monte Carlo (MC) particle transport codes lack native support for B-Rep geometries, requiring complex and non-automated conversion to compatible formats, further complicating their use. To address these challenges, we developed the interactive posture program (IPP), a software platform to ease the use of B-Rep phantoms. The IPP features a real-time three-dimensional (3D) graphical interface, allowing users to easily create individualised phantoms and realistic exposure scenarios. Currently, the IPP includes three flexible phantoms—Adult Male, Adult Female, and 1-year-old Female—from the realistic anthropomorphic flexible (RAF) family, which can be extensively customised using integrated morphing tools to simulate diverse anatomical variations. Additionally, the IPP provides a comprehensive library of predefined exposure scenarios and advanced geometry creation tools, which allow the creation of accurate and individualised simulations. Finally, the IPP automatically generates simulation input files compatible with the most widely used MC transport codes, significantly simplifying the use of B-Rep phantoms within dosimetry and imaging simulations.
- 1 December 2025
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 45 (4) , 041519
Interactive posture program: a software platform for using the realistic anthropomorphic flexible phantom family in computational dosimetry applications
Boundary-representation (B-Rep) computational phantoms (CPs) offer high flexibility and anatomical accuracy, making them valuable tools in dosimetry and medical imaging simulations. However, their complexity and the need for expertise in graphic modelling limit their accessibility and adoption. Moreover, most Monte Carlo (MC) particle transport codes lack native support for B-Rep geometries, requiring complex and non-automated conversion to compatible formats, further complicating their use. To address these challenges, we developed the interactive posture program (IPP), a software platform to ease the use of B-Rep phantoms. The IPP features a real-time three-dimensional (3D) graphical interface, allowing users to easily create individualised phantoms and realistic exposure scenarios. Currently, the IPP includes three flexible phantoms—Adult Male, Adult Female, and 1-year-old Female—from the realistic anthropomorphic flexible (RAF) family, which can be extensively customised using integrated morphing tools to simulate diverse anatomical variations. Additionally, the IPP provides a comprehensive library of predefined exposure scenarios and advanced geometry creation tools, which allow the creation of accurate and individualised simulations. Finally, the IPP automatically generates simulation input files compatible with the most widely used MC transport codes, significantly simplifying the use of B-Rep phantoms within dosimetry and imaging simulations.
- Open Access
- 27 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105077
Monte Carlo study of the eye lens exposure of medical staff administering Sc-47 and Cu-67 labelled radiopharmaceuticals
- 27 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105077
Open AccessMonte Carlo study of the eye lens exposure of medical staff administering Sc-47 and Cu-67 labelled radiopharmaceuticals
- Top Cited PapersOpen Access
- 11 April 2025
- Published by Springer Nature in Nature Medicine
- Vol. 31 (7) , 2452
Author Correction: Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults
- 11 April 2025
- Published by Springer Nature in Nature Medicine
- Vol. 31 (7) , 2452
Top Cited PapersOpen AccessAuthor Correction: Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults
- Open Access
- 1 December 2024
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 44 (4) , 041513
Doses from ionising radiation in paediatric cardiac catheterisations in Norway 1975–2021
Paediatric patients with congenital heart disease often undergo cardiac catheterisation procedures and are exposed to considerable ionising radiation early in life. This study aimed to develop a method for estimating the dose area product (P KA) from paediatric cardiac catheterisation procedures (1975–1989) at a national centre for paediatric cardiology and to evaluate trends in P KA and exposure parameters until 2021. Data from 2200 catheterisation procedures on 1685 patients (1975–1989) and 4184 procedures on 2139 patients (2000–2021) under 18 years of age were retrospectively collected. P KA values were missing for 1975–1989 but available from 2000 onward. The missing P KA was estimated from air kerma and beam area, based on exposure records and input from clinicians working at that time. P KA trends were analysed over time and age. There was a 71% reduction in median P KA from the period 1975–1989 (median 6.63 Gy cm2) to 2011–2021 (1.91 Gy cm2). The P KA increases significantly (p = 0.0001) with patient age, which was associated with body weight. Approximately 80% of the total P KA was from cine acquisition in 1975–1989, while 20% was from fluoroscopy. The P KA estimate during 1975–1989 was considerably impacted by the assumptions of missing parameters such as tube filtration, focus-to-heart distance, beam area, and number of cine series. The decreasing trend in P KA values was attributed to advancements in both technologies and clinical practices. The high contribution of cine acquisition to the total dose during 1975–1989 was due to factors such as a high frame rate, multiple acquisitions, and high tube current. The estimated P KA values for the period 1975–1989 are of importance for the dose reconstruction and risk assessments in the EU epidemiology project Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics(HARMONIC).
- 1 December 2024
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 44 (4) , 041513
Open AccessDoses from ionising radiation in paediatric cardiac catheterisations in Norway 1975–2021
Paediatric patients with congenital heart disease often undergo cardiac catheterisation procedures and are exposed to considerable ionising radiation early in life. This study aimed to develop a method for estimating the dose area product (P KA) from paediatric cardiac catheterisation procedures (1975–1989) at a national centre for paediatric cardiology and to evaluate trends in P KA and exposure parameters until 2021. Data from 2200 catheterisation procedures on 1685 patients (1975–1989) and 4184 procedures on 2139 patients (2000–2021) under 18 years of age were retrospectively collected. P KA values were missing for 1975–1989 but available from 2000 onward. The missing P KA was estimated from air kerma and beam area, based on exposure records and input from clinicians working at that time. P KA trends were analysed over time and age. There was a 71% reduction in median P KA from the period 1975–1989 (median 6.63 Gy cm2) to 2011–2021 (1.91 Gy cm2). The P KA increases significantly (p = 0.0001) with patient age, which was associated with body weight. Approximately 80% of the total P KA was from cine acquisition in 1975–1989, while 20% was from fluoroscopy. The P KA estimate during 1975–1989 was considerably impacted by the assumptions of missing parameters such as tube filtration, focus-to-heart distance, beam area, and number of cine series. The decreasing trend in P KA values was attributed to advancements in both technologies and clinical practices. The high contribution of cine acquisition to the total dose during 1975–1989 was due to factors such as a high frame rate, multiple acquisitions, and high tube current. The estimated P KA values for the period 1975–1989 are of importance for the dose reconstruction and risk assessments in the EU epidemiology project Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics(HARMONIC).
- Top Cited PapersOpen Access
- 9 November 2023
- Published by Springer Nature in Nature Medicine
- Vol. 29 (12) , 3111-3119
Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults
Over one million European children undergo computed tomography (CT) scans annually. Although moderate- to high-dose ionizing radiation exposure is an established risk factor for hematological malignancies, risks at CT examination dose levels remain uncertain. Here we followed up a multinational cohort (EPI-CT) of 948,174 individuals who underwent CT examinations before age 22 years in nine European countries. Radiation doses to the active bone marrow were estimated on the basis of body part scanned, patient characteristics, time period and inferred CT technical parameters. We found an association between cumulative dose and risk of all hematological malignancies, with an excess relative risk of 1.96 (95% confidence interval 1.10 to 3.12) per 100 mGy (790 cases). Similar estimates were obtained for lymphoid and myeloid malignancies. Results suggest that for every 10,000 children examined today (mean dose 8 mGy), 1–2 persons are expected to develop a hematological malignancy attributable to radiation exposure in the subsequent 12 years. Our results strengthen the body of evidence of increased cancer risk at low radiation doses and highlight the need for continued justification of pediatric CT examinations and optimization of doses.
- 9 November 2023
- Published by Springer Nature in Nature Medicine
- Vol. 29 (12) , 3111-3119
Top Cited PapersOpen AccessRisk of hematological malignancies from CT radiation exposure in children, adolescents and young adults
Over one million European children undergo computed tomography (CT) scans annually. Although moderate- to high-dose ionizing radiation exposure is an established risk factor for hematological malignancies, risks at CT examination dose levels remain uncertain. Here we followed up a multinational cohort (EPI-CT) of 948,174 individuals who underwent CT examinations before age 22 years in nine European countries. Radiation doses to the active bone marrow were estimated on the basis of body part scanned, patient characteristics, time period and inferred CT technical parameters. We found an association between cumulative dose and risk of all hematological malignancies, with an excess relative risk of 1.96 (95% confidence interval 1.10 to 3.12) per 100 mGy (790 cases). Similar estimates were obtained for lymphoid and myeloid malignancies. Results suggest that for every 10,000 children examined today (mean dose 8 mGy), 1–2 persons are expected to develop a hematological malignancy attributable to radiation exposure in the subsequent 12 years. Our results strengthen the body of evidence of increased cancer risk at low radiation doses and highlight the need for continued justification of pediatric CT examinations and optimization of doses.
- 8 November 2023
- Published by Elsevier in Physica Medica
- Vol. 115, 102761
THE EURADOS EXPERIENCE ON EXTREMITY EXPOSURE OF WORKERS IN NUCLEAR MEDICINE
- 8 November 2023
- Published by Elsevier in Physica Medica
- Vol. 115, 102761
THE EURADOS EXPERIENCE ON EXTREMITY EXPOSURE OF WORKERS IN NUCLEAR MEDICINE
- 17 February 2023
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 43 (1) , 011513
Impact of the implementation of the new radiation quantities recommended by ICRU/ICRP for practical use in interventional radiology: a Monte Carlo study
The International Commission on Radiation Units and Measurements (ICRU) proposed a new set of operational quantities for radiation protection for external radiation in its Report Committee 26 (ICRU 95). The new proposal aims to improve the coherence between the operational quantities and the definitions of the protection quantities in the recommendations of the International Commission on Radiological Protection set out in 2007 (Ann. ICRP 37). It is expected that this change in operational quantities will impact current dosimeter designs. Although for many photon energies, the conversion coefficients from physical field quantities to the new operational quantities will change relatively little, for radiation fields with low energy photon components, such as medical x-ray applications, there will be a significant decrease in the values of the conversion coefficients. This means that the numerical values of the new operational quantities will be much lower for the same radiation field. These values will be closer to the effective dose, but this change can still cause confusion for medical staff. It is important to examine the effect of the new set of dose conversion coefficients on the personal dose in realistic radiation fields. We performed a study to assess the effect of changing the definition of the operational quantity, personal dose equivalent ( H p ), in realistic radiation fields in interventional radiology (IR) workplaces. The x-ray tube kilovoltage peak (kVp) in IR ranges between 60 and 120 kV. The medical staff is exposed to the scattered photons which have a wide range of energies depending on the beam configuration and the patient size. The objective of this study is to ‘quantitatively’ estimate the impact of implementing the new ICRU quantities of Report 95 in IR radiation fields using Monte Carlo simulations. Simulations of 560 different configurations in IR were performed using MCNPX to calculate fluence binned per energy and angle of incidence. H p and H p ( 10 ) were then calculated for each configuration using dose conversion coefficients from fluence given by ICRU Reports 95 and 57, respectively. The results show that the mean of the ratio, H p ( 10 ) / H p , is 1.6 for all simulated scenarios. This reduction will correct the current overestimation of the effective dose and should result in better compliance with the dose limits in IR. However, it may also have negative consequences on the safety culture among the medical staff. Special care will be needed when interpreting these lower doses.
- 17 February 2023
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 43 (1) , 011513
Impact of the implementation of the new radiation quantities recommended by ICRU/ICRP for practical use in interventional radiology: a Monte Carlo study
The International Commission on Radiation Units and Measurements (ICRU) proposed a new set of operational quantities for radiation protection for external radiation in its Report Committee 26 (ICRU 95). The new proposal aims to improve the coherence between the operational quantities and the definitions of the protection quantities in the recommendations of the International Commission on Radiological Protection set out in 2007 (Ann. ICRP 37). It is expected that this change in operational quantities will impact current dosimeter designs. Although for many photon energies, the conversion coefficients from physical field quantities to the new operational quantities will change relatively little, for radiation fields with low energy photon components, such as medical x-ray applications, there will be a significant decrease in the values of the conversion coefficients. This means that the numerical values of the new operational quantities will be much lower for the same radiation field. These values will be closer to the effective dose, but this change can still cause confusion for medical staff. It is important to examine the effect of the new set of dose conversion coefficients on the personal dose in realistic radiation fields. We performed a study to assess the effect of changing the definition of the operational quantity, personal dose equivalent ( H p ), in realistic radiation fields in interventional radiology (IR) workplaces. The x-ray tube kilovoltage peak (kVp) in IR ranges between 60 and 120 kV. The medical staff is exposed to the scattered photons which have a wide range of energies depending on the beam configuration and the patient size. The objective of this study is to ‘quantitatively’ estimate the impact of implementing the new ICRU quantities of Report 95 in IR radiation fields using Monte Carlo simulations. Simulations of 560 different configurations in IR were performed using MCNPX to calculate fluence binned per energy and angle of incidence. H p and H p ( 10 ) were then calculated for each configuration using dose conversion coefficients from fluence given by ICRU Reports 95 and 57, respectively. The results show that the mean of the ratio, H p ( 10 ) / H p , is 1.6 for all simulated scenarios. This reduction will correct the current overestimation of the effective dose and should result in better compliance with the dose limits in IR. However, it may also have negative consequences on the safety culture among the medical staff. Special care will be needed when interpreting these lower doses.
- Open Access
- 11 February 2023
- Published by Elsevier in Physica Medica
- Vol. 107, 102543
Effectiveness of staff radiation protection devices for interventional cardiology procedures
- 11 February 2023
- Published by Elsevier in Physica Medica
- Vol. 107, 102543
Open AccessEffectiveness of staff radiation protection devices for interventional cardiology procedures