Kristina D. Simmons
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kristina D. Simmons has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Rachel Rapaport Kelz
Hospital of the University of Pennsylvania
3 shared publications - Gašper Tkačik
Institute of Science and Technology Austria, AT-3400 Klosterneuburg, Austria
2 shared publications - Giorgos Constantine Karakousis
University of Pennsylvania 16 Philadelphia, PA
2 shared publications Jan Homann
Department of Physics, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
2 shared publications- Lindsay E. Kuo
Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
2 shared publications - Philip Nelson
University of Pennsylvania
2 shared publications
Latest Publications
- 1 March 2017
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 265 (3) , 514-520
Variation in the Utilization of Minimally Invasive Surgical Operations
The goal of this study was to examine regional variation in use of minimally invasive surgical (MIS) operations. Regional variation exists in performance of surgical operations. Variation in the use of MIS has not been studied. Five operations that are performed open or MIS were selected: cholecystectomy, appendectomy, colectomy, antireflux, and bariatric. A 3-state database from 2008 to 2011 was used; states were divided into hospital service areas (HSAs). For each operation, the percentage of MIS operations was calculated. HSAs with less than 50% or more than 150% of the MIS average were considered outliers. Population demographics, geography, and hospital and physician presence were compared between HSAs. Rates of performance by patient disease and the presence of MIS surgeons were also investigated. MIS cholecystectomy was performed with low variation; MIS appendectomy, antireflux, and bariatric operations with medium variation; and MIS colectomy with high variation. With the exception of MIS colectomy, there were no differences in the patient demographics, geography, or disease types treated with an MIS approach between HSAs with low-, non-, or high utilization of MIS. There is no correlation between the number of MIS surgeons and the percentage of procedures performed MIS. Variation in utilization of MIS exists and differs by operation. Patient demographics, patient disease, and the ability to access care are associated only with variation in use of MIS for colectomy. For all other operations studied, these factors do not explain variation in MIS use. Further investigation is warranted to identify and eliminate causes of variation.
- 1 March 2017
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 265 (3) , 514-520
Variation in the Utilization of Minimally Invasive Surgical Operations
The goal of this study was to examine regional variation in use of minimally invasive surgical (MIS) operations. Regional variation exists in performance of surgical operations. Variation in the use of MIS has not been studied. Five operations that are performed open or MIS were selected: cholecystectomy, appendectomy, colectomy, antireflux, and bariatric. A 3-state database from 2008 to 2011 was used; states were divided into hospital service areas (HSAs). For each operation, the percentage of MIS operations was calculated. HSAs with less than 50% or more than 150% of the MIS average were considered outliers. Population demographics, geography, and hospital and physician presence were compared between HSAs. Rates of performance by patient disease and the presence of MIS surgeons were also investigated. MIS cholecystectomy was performed with low variation; MIS appendectomy, antireflux, and bariatric operations with medium variation; and MIS colectomy with high variation. With the exception of MIS colectomy, there were no differences in the patient demographics, geography, or disease types treated with an MIS approach between HSAs with low-, non-, or high utilization of MIS. There is no correlation between the number of MIS surgeons and the percentage of procedures performed MIS. Variation in utilization of MIS exists and differs by operation. Patient demographics, patient disease, and the ability to access care are associated only with variation in use of MIS for colectomy. For all other operations studied, these factors do not explain variation in MIS use. Further investigation is warranted to identify and eliminate causes of variation.
- 29 March 2016
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 23 (8) , 2571-2576
Racial Disparities in Initial Presentation of Benign Thyroid Disease for Resection
Racial disparities exist in thyroidectomy outcomes. One contributing factor may be the disease state upon presentation to a surgeon. Minorities with thyroid cancer present at a later disease stage and with larger tumors. This relationship has not been examined for benign thyroid disease. We sought to examine the association between race, referral patterns, and disease severity for benign thyroid conditions. We analyzed all patients receiving a thyroidectomy for benign disease in our institutional endocrine surgery registry. Patient demographics, disease history, disease severity, and postoperative outcomes were investigated. Univariate analysis compared black and white patients. Multivariable linear regression examined the relationship between race and time to surgical referral. Of the 1189 patients studied, the majority (86.0 %) were white. Black and white patients differed in median income and reason for referral. When compared with white patients, black patients more commonly presented with compressive symptoms (black: 45.0 % vs. white: 21.2 %, p < .01) and dysphagia (19.0 % vs. 10.1 %, p < .01), and after a longer disease duration [black: median 0 years (interquartile ratio, IQR, 0-5) vs. white: 0 years (IQR, 0-2)]. Blacks also had larger glands than white [median 71 grams (IQR, 33.5-155.3) vs. 24.3 grams (IQR, 15.0-50.2)]. With the exception of reintubation rate, there were no differences in postoperative outcomes. Black patients with benign thyroid conditions have a longer time to surgical referral and present for surgical evaluation with more severe disease than white patients. Identification of these disparities is the first step in eliminating differences in patient care.
- 29 March 2016
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 23 (8) , 2571-2576
Racial Disparities in Initial Presentation of Benign Thyroid Disease for Resection
Racial disparities exist in thyroidectomy outcomes. One contributing factor may be the disease state upon presentation to a surgeon. Minorities with thyroid cancer present at a later disease stage and with larger tumors. This relationship has not been examined for benign thyroid disease. We sought to examine the association between race, referral patterns, and disease severity for benign thyroid conditions. We analyzed all patients receiving a thyroidectomy for benign disease in our institutional endocrine surgery registry. Patient demographics, disease history, disease severity, and postoperative outcomes were investigated. Univariate analysis compared black and white patients. Multivariable linear regression examined the relationship between race and time to surgical referral. Of the 1189 patients studied, the majority (86.0 %) were white. Black and white patients differed in median income and reason for referral. When compared with white patients, black patients more commonly presented with compressive symptoms (black: 45.0 % vs. white: 21.2 %, p < .01) and dysphagia (19.0 % vs. 10.1 %, p < .01), and after a longer disease duration [black: median 0 years (interquartile ratio, IQR, 0-5) vs. white: 0 years (IQR, 0-2)]. Blacks also had larger glands than white [median 71 grams (IQR, 33.5-155.3) vs. 24.3 grams (IQR, 15.0-50.2)]. With the exception of reintubation rate, there were no differences in postoperative outcomes. Black patients with benign thyroid conditions have a longer time to surgical referral and present for surgical evaluation with more severe disease than white patients. Identification of these disparities is the first step in eliminating differences in patient care.
- 1 April 2015
- Published by Elsevier in Journal of Critical Care
- Vol. 30 (2) , 310-314
A risk prediction model for mortality in the moribund general surgical patient
- 1 April 2015
- Published by Elsevier in Journal of Critical Care
- Vol. 30 (2) , 310-314
A risk prediction model for mortality in the moribund general surgical patient
- Open Access
The rise in metastasectomy across cancer types over the past decade
BACKGROUND: Although studies of metastasectomy have been limited primarily to institutional experiences, reports of favorable long‐term outcomes have generated increasing interest. In the current study, the authors attempted to define the national practice patterns in metastasectomy for 4 common malignancies with varying responsiveness to systemic therapy.METHODS: The National (Nationwide) Inpatient Sample was used to estimate the national incidence of metastasectomy for colorectal cancer, lung cancer, breast cancer, and melanoma from 2000 through 2011. Incidence‐adjusted rates were determined for liver, lung, brain, small bowel, and adrenal metastasectomies. The average annual percentage change (AAPC) in metastasectomy by cancer type was calculated using joinpoint regression.RESULTS: Colorectal cancer was the most common indication for metastasectomy (87,407 cases; 95% confidence interval [95% CI], 86,307‐88,507 cases) followed by lung cancer (58,245 cases; 95% CI, 57,453‐59,036 cases), breast cancer (26,271 cases; 95% CI, 25,672‐26,870 cases), and melanoma (20,298 cases; 95% CI, 19,897‐20,699 cases). Metastasectomy increased significantly for all cancer types over the study period: colorectal cancer (AAPC, 6.83; 95% CI, 5.7‐7.9), lung cancer (AAPC, 5.8; 95% CI, 5.1‐6.4), breast cancer (AAPC, 5.5; 95% CI, 3.7‐7.3), and melanoma (AAPC, 4.03; 95% CI, 2.1‐6.0). Despite an increasing number of comorbidities in patients undergoing metastasectomy (P<.05 for each cancer type), inpatient mortality rates after metastasectomy fell for all cancer types, most significantly for colorectal (AAPC, −5.49; 95% CI, −8.2 to −2.7) and lung (AAPC, −6.2; 95% CI, −11.7 to −0.3) cancers. The increasing performance of metastasectomy was largely driven by high‐volume institutions, in which patients had a lower mean number of comorbidities (P<.01 for all cancer types) and lower inpatient mortality (P<.01 for all cancers except melanoma).CONCLUSIONS: From 2000 through 2011, the performance of metastasectomy increased substantially across common cancer types, notwithstanding various advances in systemic therapies. Metastasectomy was performed more safely, despite increasing patient comorbidity. High‐volume institutions appeared to drive practice patterns. Cancer 2015;121:747–757. © 2014 American Cancer Society.
Open AccessThe rise in metastasectomy across cancer types over the past decade
BACKGROUND: Although studies of metastasectomy have been limited primarily to institutional experiences, reports of favorable long‐term outcomes have generated increasing interest. In the current study, the authors attempted to define the national practice patterns in metastasectomy for 4 common malignancies with varying responsiveness to systemic therapy.METHODS: The National (Nationwide) Inpatient Sample was used to estimate the national incidence of metastasectomy for colorectal cancer, lung cancer, breast cancer, and melanoma from 2000 through 2011. Incidence‐adjusted rates were determined for liver, lung, brain, small bowel, and adrenal metastasectomies. The average annual percentage change (AAPC) in metastasectomy by cancer type was calculated using joinpoint regression.RESULTS: Colorectal cancer was the most common indication for metastasectomy (87,407 cases; 95% confidence interval [95% CI], 86,307‐88,507 cases) followed by lung cancer (58,245 cases; 95% CI, 57,453‐59,036 cases), breast cancer (26,271 cases; 95% CI, 25,672‐26,870 cases), and melanoma (20,298 cases; 95% CI, 19,897‐20,699 cases). Metastasectomy increased significantly for all cancer types over the study period: colorectal cancer (AAPC, 6.83; 95% CI, 5.7‐7.9), lung cancer (AAPC, 5.8; 95% CI, 5.1‐6.4), breast cancer (AAPC, 5.5; 95% CI, 3.7‐7.3), and melanoma (AAPC, 4.03; 95% CI, 2.1‐6.0). Despite an increasing number of comorbidities in patients undergoing metastasectomy (P<.05 for each cancer type), inpatient mortality rates after metastasectomy fell for all cancer types, most significantly for colorectal (AAPC, −5.49; 95% CI, −8.2 to −2.7) and lung (AAPC, −6.2; 95% CI, −11.7 to −0.3) cancers. The increasing performance of metastasectomy was largely driven by high‐volume institutions, in which patients had a lower mean number of comorbidities (P<.01 for all cancer types) and lower inpatient mortality (P<.01 for all cancers except melanoma).CONCLUSIONS: From 2000 through 2011, the performance of metastasectomy increased substantially across common cancer types, notwithstanding various advances in systemic therapies. Metastasectomy was performed more safely, despite increasing patient comorbidity. High‐volume institutions appeared to drive practice patterns. Cancer 2015;121:747–757. © 2014 American Cancer Society.
- Open Access
- 5 December 2013
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 9 (12) , e1003344
Transformation of Stimulus Correlations by the Retina
Redundancies and correlations in the responses of sensory neurons may seem to waste neural resources, but they can also carry cues about structured stimuli and may help the brain to correct for response errors. To investigate the effect of stimulus structure on redundancy in retina, we measured simultaneous responses from populations of retinal ganglion cells presented with natural and artificial stimuli that varied greatly in correlation structure; these stimuli and recordings are publicly available online. Responding to spatio-temporally structured stimuli such as natural movies, pairs of ganglion cells were modestly more correlated than in response to white noise checkerboards, but they were much less correlated than predicted by a non-adapting functional model of retinal response. Meanwhile, responding to stimuli with purely spatial correlations, pairs of ganglion cells showed increased correlations consistent with a static, non-adapting receptive field and nonlinearity. We found that in response to spatio-temporally correlated stimuli, ganglion cells had faster temporal kernels and tended to have stronger surrounds. These properties of individual cells, along with gain changes that opposed changes in effective contrast at the ganglion cell input, largely explained the pattern of pairwise correlations across stimuli where receptive field measurements were possible. An influential theory of early sensory processing argues that sensory circuits should conserve scarce resources in their outputs by reducing correlations present in their inputs. Measuring simultaneous responses from large numbers of retinal ganglion cells responding to widely different classes of visual stimuli, we find that output correlations increase when we present stimuli with spatial, but not temporal, correlations. On the other hand, we find evidence that retina adjusts to spatio-temporal structure so that retinal output correlations change less than input correlations would predict. Changes in the receptive field properties of individual cells, along with gain changes, largely explain this relative constancy of correlations over the population.
- 5 December 2013
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 9 (12) , e1003344
Open AccessTransformation of Stimulus Correlations by the Retina
Redundancies and correlations in the responses of sensory neurons may seem to waste neural resources, but they can also carry cues about structured stimuli and may help the brain to correct for response errors. To investigate the effect of stimulus structure on redundancy in retina, we measured simultaneous responses from populations of retinal ganglion cells presented with natural and artificial stimuli that varied greatly in correlation structure; these stimuli and recordings are publicly available online. Responding to spatio-temporally structured stimuli such as natural movies, pairs of ganglion cells were modestly more correlated than in response to white noise checkerboards, but they were much less correlated than predicted by a non-adapting functional model of retinal response. Meanwhile, responding to stimuli with purely spatial correlations, pairs of ganglion cells showed increased correlations consistent with a static, non-adapting receptive field and nonlinearity. We found that in response to spatio-temporally correlated stimuli, ganglion cells had faster temporal kernels and tended to have stronger surrounds. These properties of individual cells, along with gain changes that opposed changes in effective contrast at the ganglion cell input, largely explained the pattern of pairwise correlations across stimuli where receptive field measurements were possible. An influential theory of early sensory processing argues that sensory circuits should conserve scarce resources in their outputs by reducing correlations present in their inputs. Measuring simultaneous responses from large numbers of retinal ganglion cells responding to widely different classes of visual stimuli, we find that output correlations increase when we present stimuli with spatial, but not temporal, correlations. On the other hand, we find evidence that retina adjusts to spatio-temporal structure so that retinal output correlations change less than input correlations would predict. Changes in the receptive field properties of individual cells, along with gain changes, largely explain this relative constancy of correlations over the population.
- Open Access
- 20 July 2011
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 6 (7) , e19884
Fast, Scalable, Bayesian Spike Identification for Multi-Electrode Arrays
We present an algorithm to identify individual neural spikes observed on high-density multi-electrode arrays (MEAs). Our method can distinguish large numbers of distinct neural units, even when spikes overlap, and accounts for intrinsic variability of spikes from each unit. As MEAs grow larger, it is important to find spike-identification methods that are scalable, that is, the computational cost of spike fitting should scale well with the number of units observed. Our algorithm accomplishes this goal, and is fast, because it exploits the spatial locality of each unit and the basic biophysics of extracellular signal propagation. Human interaction plays a key role in our method; but effort is minimized and streamlined via a graphical interface. We illustrate our method on data from guinea pig retinal ganglion cells and document its performance on simulated data consisting of spikes added to experimentally measured background noise. We present several tests demonstrating that the algorithm is highly accurate: it exhibits low error rates on fits to synthetic data, low refractory violation rates, good receptive field coverage, and consistency across users.
- 20 July 2011
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 6 (7) , e19884
Open AccessFast, Scalable, Bayesian Spike Identification for Multi-Electrode Arrays
We present an algorithm to identify individual neural spikes observed on high-density multi-electrode arrays (MEAs). Our method can distinguish large numbers of distinct neural units, even when spikes overlap, and accounts for intrinsic variability of spikes from each unit. As MEAs grow larger, it is important to find spike-identification methods that are scalable, that is, the computational cost of spike fitting should scale well with the number of units observed. Our algorithm accomplishes this goal, and is fast, because it exploits the spatial locality of each unit and the basic biophysics of extracellular signal propagation. Human interaction plays a key role in our method; but effort is minimized and streamlined via a graphical interface. We illustrate our method on data from guinea pig retinal ganglion cells and document its performance on simulated data consisting of spikes added to experimentally measured background noise. We present several tests demonstrating that the algorithm is highly accurate: it exhibits low error rates on fits to synthetic data, low refractory violation rates, good receptive field coverage, and consistency across users.