Richard Walker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Richard Walker has a total of 151 co-authors. Here are the top co-authors by number of shared publications:
- Robert K. Henderson
The University of Edinburgh
18 shared publications David Stoppa
Fondazione Bruno Kessler (Italy)
13 shared publications- David Day-Uei Li
University of Strathclyde
10 shared publications Justin Richardson
Institute for Integrated Micro and Nano Systems, School of Engineering, University of Edinburgh, Edinburgh, UK
9 shared publications- Nikola Krstajić
Institute for Integrated Micro and Nano Systems, School of Engineering, University of Edinburgh, Edinburgh, UK
9 shared publications Edoardo Charbon
Ecole Polytechnique Federale de Lausanne (Switzerland)
8 shared publications
Latest Publications
- Open Access
- 4 May 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (10) , 11103-11123
Time-resolved spectroscopy at 19,000 lines per second using a CMOS SPAD line array enables advanced biophotonics applications
A SPAD-based line sensor fabricated in 130 nm CMOS technology capable of acquiring time-resolved fluorescence spectra (TRFS) in 8.3 milliseconds is presented. To the best of our knowledge, this is the fastest time correlated single photon counting (TCSPC) TRFS acquisition reported to date. The line sensor is an upgrade to our prior work and incorporates: i) parallelized interface from sensor to surrounding circuitry enabling high line rate to the PC (19,000 lines/s) and ii) novel time-gating architecture where detected photons in the OFF region are rejected digitally after the output stage of the SPAD. The time-gating architecture was chosen to avoid electrical transients on the SPAD high voltage supplies when gating is achieved by excess bias modulation. The time-gate has an adjustable location and time window width allowing the user to focus on time-events of interest. On-chip integrated center-of-mass (CMM) calculations provide efficient acquisition of photon arrivals and direct lifetime estimation of fluorescence decays. Furthermore, any of the SPC, TCSPC and on-chip CMM modes can be used in conjunction with the time-gating. The higher readout rate and versatile architecture greatly empower the user and will allow widespread applications across many techniques and disciplines. Here we focused on 3 examples of TRFS and time-gated Raman spectroscopy: i) kinetics of chlorophyll A fluorescence from an intact leaf; ii) kinetics of a thrombin biosensor FRET probe from quenched to fluorescence states; iii) ex vivo mouse lung tissue autofluorescence TRFS; iv) time-gated Raman spectroscopy of toluene at 3056 cm−1 peak. To the best of our knowledge, we detect spectrally for the first time the fast rise in fluorescence lifetime of chlorophyll A in a measurement over single fluorescent transient.
- 4 May 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (10) , 11103-11123
Open AccessTime-resolved spectroscopy at 19,000 lines per second using a CMOS SPAD line array enables advanced biophotonics applications
A SPAD-based line sensor fabricated in 130 nm CMOS technology capable of acquiring time-resolved fluorescence spectra (TRFS) in 8.3 milliseconds is presented. To the best of our knowledge, this is the fastest time correlated single photon counting (TCSPC) TRFS acquisition reported to date. The line sensor is an upgrade to our prior work and incorporates: i) parallelized interface from sensor to surrounding circuitry enabling high line rate to the PC (19,000 lines/s) and ii) novel time-gating architecture where detected photons in the OFF region are rejected digitally after the output stage of the SPAD. The time-gating architecture was chosen to avoid electrical transients on the SPAD high voltage supplies when gating is achieved by excess bias modulation. The time-gate has an adjustable location and time window width allowing the user to focus on time-events of interest. On-chip integrated center-of-mass (CMM) calculations provide efficient acquisition of photon arrivals and direct lifetime estimation of fluorescence decays. Furthermore, any of the SPC, TCSPC and on-chip CMM modes can be used in conjunction with the time-gating. The higher readout rate and versatile architecture greatly empower the user and will allow widespread applications across many techniques and disciplines. Here we focused on 3 examples of TRFS and time-gated Raman spectroscopy: i) kinetics of chlorophyll A fluorescence from an intact leaf; ii) kinetics of a thrombin biosensor FRET probe from quenched to fluorescence states; iii) ex vivo mouse lung tissue autofluorescence TRFS; iv) time-gated Raman spectroscopy of toluene at 3056 cm−1 peak. To the best of our knowledge, we detect spectrally for the first time the fast rise in fluorescence lifetime of chlorophyll A in a measurement over single fluorescent transient.
- Open Access
- 25 January 2017
- Published by Springer Nature in Nature Communications
- Vol. 8 (1) , 14080
Multiplexed single-mode wavelength-to-time mapping of multimode light
When an optical pulse propagates along an optical fibre, different wavelengths travel at different group velocities. As a result, wavelength information is converted into arrival-time information, a process known as wavelength-to-time mapping. This phenomenon is most cleanly observed using a single-mode fibre transmission line, where spatial mode dispersion is not present, but the use of such fibres restricts possible applications. Here we demonstrate that photonic lanterns based on tapered single-mode multicore fibres provide an efficient way to couple multimode light to an array of single-photon avalanche detectors, each of which has its own time-to-digital converter for time-correlated single-photon counting. Exploiting this capability, we demonstrate the multiplexed single-mode wavelength-to-time mapping of multimode light using a multicore fibre photonic lantern with 121 single-mode cores, coupled to 121 detectors on a 32 × 32 detector array. This work paves the way to efficient multimode wavelength-to-time mapping systems with the spectral performance of single-mode systems.
- 25 January 2017
- Published by Springer Nature in Nature Communications
- Vol. 8 (1) , 14080
Open AccessMultiplexed single-mode wavelength-to-time mapping of multimode light
When an optical pulse propagates along an optical fibre, different wavelengths travel at different group velocities. As a result, wavelength information is converted into arrival-time information, a process known as wavelength-to-time mapping. This phenomenon is most cleanly observed using a single-mode fibre transmission line, where spatial mode dispersion is not present, but the use of such fibres restricts possible applications. Here we demonstrate that photonic lanterns based on tapered single-mode multicore fibres provide an efficient way to couple multimode light to an array of single-photon avalanche detectors, each of which has its own time-to-digital converter for time-correlated single-photon counting. Exploiting this capability, we demonstrate the multiplexed single-mode wavelength-to-time mapping of multimode light using a multicore fibre photonic lantern with 121 single-mode cores, coupled to 121 detectors on a 32 × 32 detector array. This work paves the way to efficient multimode wavelength-to-time mapping systems with the spectral performance of single-mode systems.
- Open Access
- 21 March 2016
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (7) , 6899-6915
New high-speed centre of mass method incorporating background subtraction for accurate determination of fluorescence lifetime
We demonstrate an implementation of a centre-of-mass method (CMM) incorporating background subtraction for use in multifocal fluorescence lifetime imaging microscopy to accurately determine fluorescence lifetime in live cell imaging using the Megaframe camera. The inclusion of background subtraction solves one of the major issues associated with centre-of-mass approaches, namely the sensitivity of the algorithm to background signal. The algorithm, which is predominantly implemented in hardware, provides real-time lifetime output and allows the user to effectively condense large amounts of photon data. Instead of requiring the transfer of thousands of photon arrival times, the lifetime is simply represented by one value which allows the system to collect data up to limit of pulse pile-up without any limitations on data transfer rates. In order to evaluate the performance of this new CMM algorithm with existing techniques (i.e. rapid lifetime determination and Levenburg-Marquardt), we imaged live MCF-7 human breast carcinoma cells transiently transfected with FRET standards. We show that, it offers significant advantages in terms of lifetime accuracy and insensitivity to variability in dark count rate (DCR) between Megaframe camera pixels. Unlike other algorithms no prior knowledge of the expected lifetime is required to perform lifetime determination. The ability of this technique to provide real-time lifetime readout makes it extremely useful for a number of applications.
- 21 March 2016
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (7) , 6899-6915
Open AccessNew high-speed centre of mass method incorporating background subtraction for accurate determination of fluorescence lifetime
We demonstrate an implementation of a centre-of-mass method (CMM) incorporating background subtraction for use in multifocal fluorescence lifetime imaging microscopy to accurately determine fluorescence lifetime in live cell imaging using the Megaframe camera. The inclusion of background subtraction solves one of the major issues associated with centre-of-mass approaches, namely the sensitivity of the algorithm to background signal. The algorithm, which is predominantly implemented in hardware, provides real-time lifetime output and allows the user to effectively condense large amounts of photon data. Instead of requiring the transfer of thousands of photon arrival times, the lifetime is simply represented by one value which allows the system to collect data up to limit of pulse pile-up without any limitations on data transfer rates. In order to evaluate the performance of this new CMM algorithm with existing techniques (i.e. rapid lifetime determination and Levenburg-Marquardt), we imaged live MCF-7 human breast carcinoma cells transiently transfected with FRET standards. We show that, it offers significant advantages in terms of lifetime accuracy and insensitivity to variability in dark count rate (DCR) between Megaframe camera pixels. Unlike other algorithms no prior knowledge of the expected lifetime is required to perform lifetime determination. The ability of this technique to provide real-time lifetime readout makes it extremely useful for a number of applications.
- 11 September 2015
- Published by Optica Publishing Group in Optics Letters
- Vol. 40 (18) , 4305-4308
05 billion events per second time correlated single photon counting using CMOS SPAD arrays
We present a digital architecture for fast acquisition of time correlated single photon counting (TCSPC) events from a complementary metal oxide semiconductor (CMOS) single photon avalanche detector (SPAD) array (Megaframe) to the computer memory. Custom firmware was written to transmit event codes from 1024-TCSPC-enabled pixels for fast transfer of TCSPC events. Our 1024-channel TCSPC system is capable of acquiring up to TCSPC events per second with 16 histogram bins spanning a 14 ns width. Other options include TCSPC events per second with 256 histogram bins spanning either a 14 or 56 ns time window. We present a wide-field fluorescence microscopy setup demonstrating fast fluorescence lifetime data acquisition. To the best of our knowledge, this is the fastest direct TCSPC transfer from a single photon counting device to the computer to date.- 11 September 2015
- Published by Optica Publishing Group in Optics Letters
- Vol. 40 (18) , 4305-4308
05 billion events per second time correlated single photon counting using CMOS SPAD arrays
We present a digital architecture for fast acquisition of time correlated single photon counting (TCSPC) events from a complementary metal oxide semiconductor (CMOS) single photon avalanche detector (SPAD) array (Megaframe) to the computer memory. Custom firmware was written to transmit event codes from 1024-TCSPC-enabled pixels for fast transfer of TCSPC events. Our 1024-channel TCSPC system is capable of acquiring up to TCSPC events per second with 16 histogram bins spanning a 14 ns width. Other options include TCSPC events per second with 256 histogram bins spanning either a 14 or 56 ns time window. We present a wide-field fluorescence microscopy setup demonstrating fast fluorescence lifetime data acquisition. To the best of our knowledge, this is the fastest direct TCSPC transfer from a single photon counting device to the computer to date.- 14 October 2014
- Published by Optica Publishing Group in Optics Letters
- Vol. 39 (20) , 6013-6016
Time-resolved multifocal multiphoton microscope for high speed FRET imaging in vivo
Imaging the spatiotemporal interaction of proteins in vivo is essential to understanding the complexities of biological systems. The highest accuracy monitoring of protein–protein interactions is achieved using Förster resonance energy transfer (FRET) measured by fluorescence lifetime imaging, with measurements taking minutes to acquire a single frame, limiting their use in dynamic live cell systems. We present a diffraction limited, massively parallel, time-resolved multifocal multiphoton microscope capable of producing fluorescence lifetime images with 55 ps time-resolution, giving improvements in acquisition speed of a factor of 64. We present demonstrations with FRET imaging in a model cell system and demonstrate in vivo FLIM using a GTPase biosensor in the zebrafish embryo.
- 14 October 2014
- Published by Optica Publishing Group in Optics Letters
- Vol. 39 (20) , 6013-6016
Time-resolved multifocal multiphoton microscope for high speed FRET imaging in vivo
Imaging the spatiotemporal interaction of proteins in vivo is essential to understanding the complexities of biological systems. The highest accuracy monitoring of protein–protein interactions is achieved using Förster resonance energy transfer (FRET) measured by fluorescence lifetime imaging, with measurements taking minutes to acquire a single frame, limiting their use in dynamic live cell systems. We present a diffraction limited, massively parallel, time-resolved multifocal multiphoton microscope capable of producing fluorescence lifetime images with 55 ps time-resolution, giving improvements in acquisition speed of a factor of 64. We present demonstrations with FRET imaging in a model cell system and demonstrate in vivo FLIM using a GTPase biosensor in the zebrafish embryo.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 143-146
A 256 × 8 SPAD line sensor for time resolved fluorescence and raman sensing
A 256 × 8 single photon avalanche diode (SPAD) time-resolved single photon counting (TCPSC) line sensor enables both fluorescence and Raman spectroscopy in a single device. The 23.78μm pitch, 46.8% fill-factor SPAD array is implemented in a 0.13μm CMOS image sensor process. Integrating time to digital converters (TDCs) implement on-chip mono-exponential fluorescence lifetime pre-calculation allowing timing of 65k photons/pixel at 500s -1 line rate at 40ps resolution using centre-of-mass method (CMM). TCSPC histograms may also be generated with 320ps bin resolution for multi-exponential analysis.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 143-146
A 256 × 8 SPAD line sensor for time resolved fluorescence and raman sensing
A 256 × 8 single photon avalanche diode (SPAD) time-resolved single photon counting (TCPSC) line sensor enables both fluorescence and Raman spectroscopy in a single device. The 23.78μm pitch, 46.8% fill-factor SPAD array is implemented in a 0.13μm CMOS image sensor process. Integrating time to digital converters (TDCs) implement on-chip mono-exponential fluorescence lifetime pre-calculation allowing timing of 65k photons/pixel at 500s -1 line rate at 40ps resolution using centre-of-mass method (CMM). TCSPC histograms may also be generated with 320ps bin resolution for multi-exponential analysis.
- 8 May 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9129, 912913-912913-11
SPADnet: a fully digital, scalable, and networked photonic component for time-of-flight PET applications
- 8 May 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9129, 912913-912913-11
SPADnet: a fully digital, scalable, and networked photonic component for time-of-flight PET applications
- Open Access
- 1 January 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 734, 122-126
SPADnet: Embedded coincidence in a smart sensor network for PET applications
- 1 January 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 734, 122-126
Open AccessSPADnet: Embedded coincidence in a smart sensor network for PET applications
- 1 December 2013
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 8 (12) , C12026
First characterization of the SPADnet sensor: a digital silicon photomultiplier for PET applications
Silicon Photomultipliers have the ability to replace photomultiplier tubes when used as light sensors in scintillation gamma-ray detectors. Their timing properties, compactness, and magnetic field compatibility make them interesting for use in Time-of-Flight Magnetic Resonance Imaging compatible Positron Emission Tomography. In this paper, we present a new fully digital Single Photon Avalanche Diode (SPAD) based detector fabricated in CMOS image sensor technology. It contains 16x8 pixels with a pitch of 610x571.2 μm2. The Dark Count Rate and the Photon Detection Probability of each SPAD has been measured and the homogeneity of these parameters in the entire 92000 SPAD array is shown. The sensor has been optically coupled to a single LYSO needle and a LYSO array. The scintillator crystal was irradiated with several gamma sources and the resulting images and energy spectra are presented.
- 1 December 2013
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 8 (12) , C12026
First characterization of the SPADnet sensor: a digital silicon photomultiplier for PET applications
Silicon Photomultipliers have the ability to replace photomultiplier tubes when used as light sensors in scintillation gamma-ray detectors. Their timing properties, compactness, and magnetic field compatibility make them interesting for use in Time-of-Flight Magnetic Resonance Imaging compatible Positron Emission Tomography. In this paper, we present a new fully digital Single Photon Avalanche Diode (SPAD) based detector fabricated in CMOS image sensor technology. It contains 16x8 pixels with a pitch of 610x571.2 μm2. The Dark Count Rate and the Photon Detection Probability of each SPAD has been measured and the homogeneity of these parameters in the entire 92000 SPAD array is shown. The sensor has been optically coupled to a single LYSO needle and a LYSO array. The scintillator crystal was irradiated with several gamma sources and the resulting images and energy spectra are presented.
- Open Access
- 21 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 49 (1) , 301-314
A Fully Digital 8$\,\times\,$16 SiPM Array for PET Applications With Per-Pixel TDCs and Real-Time Energy Output
An 8 × 16 pixel array based on CMOS small-area silicon photomultipliers (mini-SiPMs) detectors for PET applications is reported. Each pixel is 570 × 610 μm2 in size and contains four digital mini-SiPMs, for a total of 720 SPADs, resulting in a full chip fill-factor of 35.7%. For each gamma detection, the pixel provides the total detected energy and a timestamp, obtained through two 7-b counters and two 12-b 64-ps TDCs. An adder tree overlaid on top of the pixel array sums the sensor total counts at up to 100 Msamples/s, which are then used for detecting the asynchronous gamma events on-chip, while also being output in real-time. Characterization of gamma detection performance with an 3 × 3 × 5 mm3 LYSO scintillator at 20°C is reported, showing a 511-keV gamma energy resolution of 10.9% and a coincidence timing resolution of 399 ps.
- 21 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 49 (1) , 301-314
Open AccessA Fully Digital 8$\,\times\,$16 SiPM Array for PET Applications With Per-Pixel TDCs and Real-Time Energy Output
An 8 × 16 pixel array based on CMOS small-area silicon photomultipliers (mini-SiPMs) detectors for PET applications is reported. Each pixel is 570 × 610 μm2 in size and contains four digital mini-SiPMs, for a total of 720 SPADs, resulting in a full chip fill-factor of 35.7%. For each gamma detection, the pixel provides the total detected energy and a timestamp, obtained through two 7-b counters and two 12-b 64-ps TDCs. An adder tree overlaid on top of the pixel array sums the sensor total counts at up to 100 Msamples/s, which are then used for detecting the asynchronous gamma events on-chip, while also being output in real-time. Characterization of gamma detection performance with an 3 × 3 × 5 mm3 LYSO scintillator at 20°C is reported, showing a 511-keV gamma energy resolution of 10.9% and a coincidence timing resolution of 399 ps.