GTGill Rafael Tsouri

Gill Rafael Tsouri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gill Rafael Tsouri has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Monitoring Pulse Rate in the Background Using Front Facing Cameras of Mobile Devices

    by Celal Savur, Ruslan Dautov, Kamil Bukum, Xiaojuan Xia, Jean-Philippe Couderc, Gill R. Tsouri

    We propose a novel framework to passively monitor pulse rate during the time spent by users on their personal mobile devices. Our framework is based on passively capturing the user's pulse signal using the front-facing camera. Signal capture is performed in the background, while the user is interacting with the device as he/she normally would, e.g., watch movies, read emails, text, and play games. The framework does not require subject participation with the monitoring procedure, thereby addressing the well-known problem of low adherence with such procedures. We investigate various techniques to suppress the impact of spontaneous user motion and fluctuations in ambient light conditions expected in non-participatory environments. Techniques include traditional signal processing, machine learning classifiers, and deep learning methods. Our performance evaluation is based on a clinical study encompassing 113 patients with a history of atrial fibrillation (Afib) who are passively monitored at home using a tablet for a period of two weeks. Our results show that the proposed framework accurately monitors pulse rate, thereby providing a gateway for long-term monitoring without relying on subject participation or the use of a dedicated wearable device.


  • Non-Contact Human Workload Assessment for Adaptive Intelligent Systems

    by Deep Saran Masanam, Gill Rafael Tsouri, Jamison Heard

    Heart rate and heart rate variability are important sensor modalities for estimating workload. Estimating workload with contact-based physiological sensors has been researched, however there is a need to estimate workload using non-contact physiological sensors with camera advancements. This study offers a novel approach to this research statement with a comparison between contact and non-contact sensors for workload estimation. Hybrid deep learning architecture has been developed based on data from the Bio-Harness as a contact sensor and data from the VPG as a non-contact sensor. This research can be extended to a variety of applications for adaptive intelligent systems that rely on human-state information. Reliable non-contact monitoring support seamless operations uninhibited by wearable sensors attached to the body.

  • Dynamic Off-Body Rician Channel Modeling for Indoor Wireless Body Area Networks

    by Ruslan I. Dautov, Gill R. Tsouri

    Wireless off-body channel is commonly treated as a traditional communication system assuming large and small scale fading to be independent. In this work, we challenge this approach and experimentally show that in a typical WBAN environment of a single room, this assumption is not accurate. We propose an off-body channel model where path loss and multipath fading are entirely determined by Rician distribution and linked through a stochastic Rician factor K. Treating K as a random variable, whose density is determined by the scenario under consideration, allows our model to naturally address different types of body motion along with correlated shadowing. By means of simulation supported by experiments, we show that our model is able to accurately describe probability densities of instantaneous received power in various static and dynamic settings. In addition, we demonstrate that the proposed approach can predict the off-body diversity gains due to correlated antenna reception when selection combining scheme is applied.


  • Effects of Passive Negative Correlation Attack on Sensors Utilizing Physical Key Extraction in Indoor Wireless Body Area Networks

    by Ruslan Dautov, Gill R. Tsouri

    Due to unique properties of Wireless Body Area Networks (WBANs), a strategically position eavesdropper can achieve a channel with negative correlation. This letter demonstrates that negative correlation can be exploited and poses a significant threat for sensors utilizing key extraction techniques that rely on the physical layer and make use of channel state information. In particular, we show that a commonly used method to improve key agreement between legitimate parties such as moving average, boosts the confidence of the negatively correlated attacker by 23%. We also show that the quantizer parameters need to be selected carefully to avoid information leak. Interestingly, our results indicate that such an attacker can be located much farther from the legitimate party and gain more information compared to an adversary that is located closer but does not experience negative correlation.


  • On the Benefits of Creeping Wave Antennas in Reducing Interference Between Neighboring Wireless Body Area Networks

    by Gill R. Tsouri, Stephanie R. Zambito, Jayanti Venkataraman

    We consider the on-body, off-body, and body-to-body channels in wireless body area networks utilizing creeping wave antennas. Experimental setups are used to gather measurements in the 2.4 GHz band with body area networks operating in an office environment. Data packets providing received signal strength indicators are used to assess the performance of the creeping wave antenna in reducing interference at a neighboring on-body access point while supporting reliable on-body communications. Results demonstrate that creeping wave antennas provide reliable on-body communications while significantly reducing inter-network interference; the inter-network interference is shown to be 10 dB weaker than the on-body signal. In addition, the inter-network interference when both networks utilize creeping wave antennas is shown to be 3 dB weaker than the interference when monopole antennas are used.


  • Open Access

    Respiration rate estimation from channel state information in wireless body area networks

    by G.R. Tsouri, O. Maimon

    Respiration rate is an important measure for assessing a patient's health and is typically measured using obtrusive devices. A non‐obtrusive method of estimating respiration rate by taking advantage of data packets being sent from sensor nodes in a wireless body area network is proposed and investigated. In contradistinction to other methods, the proposed method does not require dedicated hardware and does not impose overheads on transmission power and throughput. Instead, it makes use of data packets already being sent to support some other physiological monitoring applications such as cardiac, temperature or motion monitoring. The method is demonstrated on a single subject and results are presented from a study including 40 measurements taken from eight subjects. The mean estimation error in the study was 0.58 breaths per minute. The proposed method can be used to augment wireless body monitoring applications with important respiration rate measurements without imposing overheads on the compact sensor nodes.


  • Open Access

    On Increasing Network Lifetime in Body Area Networks Using Global Routing with Energy Consumption Balancing

    by Gill R. Tsouri, Alvaro Prieto, Nikhil Argade

    Global routing protocols in wireless body area networks are considered. Global routing is augmented with a novel link cost function designed to balance energy consumption across the network. The result is a substantial increase in network lifetime at the expense of a marginal increase in energy per bit. Network maintenance requirements are reduced as well, since balancing energy consumption means all batteries need to be serviced at the same time and less frequently. The proposed routing protocol is evaluated using a hardware experimental setup comprising multiple nodes and an access point. The setup is used to assess network architectures, including an on-body access point and an off-body access point with varying number of antennas. Real-time experiments are conducted in indoor environments to assess performance gains. In addition, the setup is used to record channel attenuation data which are then processed in extensive computer simulations providing insight on the effect of protocol parameters on performance. Results demonstrate efficient balancing of energy consumption across all nodes, an average increase of up to 40% in network lifetime corresponding to a modest average increase of 0.4 dB in energy per bit, and a cutoff effect on required transmission power to achieve reliable connectivity.


  • Open Access

    Constrained independent component analysis approach to nonobtrusive pulse rate measurements

    by Gill R. Tsouri, Survi Kyal, Sohail Dianat, Lalit K. Mestha

    Nonobtrusive pulse rate measurement using a webcam is considered. We demonstrate how state-of-the-art algorithms based on independent component analysis suffer from a sorting problem which hinders their performance, and propose a novel algorithm based on constrained independent component analysis to improve performance. We present how the proposed algorithm extracts a photoplethysmography signal and resolves the sorting problem. In addition, we perform a comparative study between the proposed algorithm and state-of-the-art algorithms over 45 video streams using a finger probe oxymeter for reference measurements. The proposed algorithm provides improved accuracy: the root mean square error is decreased from 20.6 and 9.5 beats per minute (bpm) for existing algorithms to 3.5 bpm for the proposed algorithm. An error of 3.5 bpm is within the inaccuracy expected from the reference measurements. This implies that the proposed algorithm provided performance of equal accuracy to the finger probe oximeter.