ZFZecong Fang

Zecong Fang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zecong Fang has a total of 68 co-authors. Here are the top co-authors by number of shared publications:

  • Tingrui Pan

    Suzhou Institute for Advanced Research, University of Science and Technology of China, Suzhou 215123, China

    9 shared publications
  • Junyi Chen

    Department of Ophthalmology and Visual Science, Eye and ENT Hospital, Shanghai Medical College Fudan University Shanghai China

    3 shared publications
  • Cheemeng Tan

    Department of Biomedical Engineering, University of California, Davis, Davis, USA

    2 shared publications
  • Jie Xu

    Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL 60607

    2 shared publications
  • Kexin Lin

    Center for Intelligent Medical Equipment and Devices (iMED), Institute for Innovative Medical Devices University of Science and Technology of China Hefei China

    2 shared publications
  • Sen Li

    Bionic Sensing and Intelligence Center (BSIC), Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology Chinese Academy of Sciences Shenzhen China

    2 shared publications

Latest Publications

  • Alignment-free solvent-enabled automatic packaging for thermoplastic microfluidics

    by Xiang Pan, Zecong Fang, Pin Lv, Tingrui Pan

    As the demands in function versatility, integration density and mass manufacturability grow, multilayer thermoplastic microfluidic devices with sophisticated structures have rapidly gained interests. Yet, great challenges persist in packaging process, namely alignment and sealing of the multiple layers, since the current schemes are typically labour-intensive and lack of automation. Herein, we introduce alignment-free solvent-enabled automatic packaging (ASAP), a novel packaging methodology that combines alignment and bonding in a single automated step. The ASAP technology applies a specialized solvent to form a liquid bridge and induce capillary action for self-alignment while promoting bonding through polymer entanglement. For the first time, the use of the solvent-based liquid bridge has combined the previously independent alignment and bonding processes into one step for thermoplastic microfluidics, as demonstrated by theoretical modelling and proof-of-concept experimentation with PMMA (the substrate) and toluene (the matching solvent). Alignment accuracy better than 1.0 μm and bonding strength greater than 7.87 MPa have been achieved in a fully automated manner. Leveraging ASAP, a 3D-structured digital flowmeter has been successfully assembled, which eliminates the otherwise tedious alignment and bonding processes. The proposed ASAP technology simplifies the packaging of multilayer thermoplastic microfluidic devices, showing great potential in numerous emerging thermoplastic microfluidics-based applications.

  • Back Cover, Volume 3, Number 2, April 2024

    by Yuyang Wang, Zecong Fang, Sen Li, Kexin Lin, Zhifeng Zhang, Junyi Chen, Tingrui Pan

  • Open Access

    Droplet Laplace valve‐enabled glaucoma implant for intraocular pressure management

    by Yuyang Wang, Zecong Fang, Sen Li, Kexin Lin, Zhifeng Zhang, Junyi Chen, Tingrui Pan

    Glaucoma, the leading cause of irreversible blindness worldwide, is closely linked to aqueous overaccumulation and elevated intraocular pressure (IOP). For refractory glaucoma, aqueous shunts with valves are commonly implanted for effective aqueous drainage control and IOP stabilization. However, existing valved glaucoma implants have the disadvantages of inconsistent valve opening/closing pressures, poor long‐term repeatability due to their reliance on moving parts, and complex architectures and fabrication processes. Here, we propose a novel valving concept, the droplet Laplace valve (DLV), a three‐dimensional printable moving‐parts‐free microvalve with customizable and consistent threshold valving pressures. The DLV uses a flow discretization unit governed by capillarity, comprising a droplet‐forming nozzle, and a separated reservoir to digitize continuous flow into quantifiable droplets. Unlike the classic one‐time‐use Laplace valves, the DLV's unique design allows for its reusability. The opening pressure is adjustable by varying the nozzle size, like the classic Laplace valves (following the Young–Laplace equation), while the closing pressure can be modified by tuning the separation distance and the reservoir size. Various DLVs with customizable opening pressures from 5 to 11 mmHg have been demonstrated, with opening/closing pressure differences suppressed down to <0.5 mmHg (<0.15 mmHg under the best conditions). Thanks to its moving‐parts‐free nature and digitized flow properties, the DLV shows a highly repeatable valving performance ( 0.99). Preliminary ex vivo validation in an enucleated porcine eye confirms the DLV's efficiency in aqueous shunting and prompt IOP stabilization. The DLV technology holds great promise in glaucoma implants for IOP management and various microsystems for flow control.


  • Microfluidics in the eye: a review of glaucoma implants from an engineering perspective

    by Zecong Fang, Shuzhen Bi, J. David Brown, Junyi Chen, Tingrui Pan

    Glaucoma is a progressive optic neuropathy in the eye, which is a leading cause of irreversible blindness worldwide and currently affects over 70 million individuals. Clinically, intraocular pressure (IOP) reduction is the only proven treatment to halt the progression of glaucoma. Microfluidic devices such as glaucoma drainage devices (GDDs) and minimally invasive glaucoma surgery (MIGS) devices are routinely used by ophthalmologists to manage elevated IOP, by creating an artificial pathway for the over-accumulated aqueous humor (AH) in a glaucomatous eye, when the natural pathways are severely blocked. Herein, a detailed modelling and analysis of both the natural microfluidic pathways of the AH in the eye and artificial microfluidic pathways formed additionally by the various glaucoma implants are conducted to provide an insight into the causes of the IOP abnormality and the improvement schemes of current implant designs. The mechanisms of representative glaucoma implants have been critically reviewed from the perspective of microfluidics, and we have categorized the current implants into four groups according to the targeted drainage sites of the AH, namely Schlemm's canal, suprachoroidal space, subconjunctival space, and ocular surface. In addition, we propose to divide the development and evolution of glaucoma implant designs into three technological waves, which include microtube (1st), microvalve (2nd) and microsystem (3rd). With the emerging trends of minimal invasiveness and artificial intelligence in the development of medical implants, we envision that a comprehensive glaucoma treatment microsystem is on the horizon, which is featured with active and wireless control of IOP, real-time continuous monitoring of IOP and aqueous rate, etc. The current review could potentially cast light on the unmatched needs, challenges, and future directions of the microfluidic structural and functional designs of glaucoma implants, which would enable an enhanced safety profile, reduced complications, increased efficacy of lowering IOP and reduced IOP fluctuations, closed-loop and on-demand control of IOP, etc.


  • Open Access

    High-Throughput Experimentation Using Cell-Free Protein Synthesis Systems

    by Conary Meyer, Chuqing Zhou, Zecong Fang, Marjorie L. Longo, Tingrui Pan, Cheemeng Tan

    Cell-free protein synthesis can enable the combinatorial screening of many different components and concentrations. However, manual pipetting methods are unfit to handle many cell-free reactions. Here, we describe a microfluidic method that can generate hundreds of unique submicroliter scale reactions. The method is coupled with a high yield cell-free system that can be applied for broad protein screening assays. Key words High throughput Cell-free protein synthesis Droplet printing Automation Protein screening Microfluidic adaptive printing Low-volume liquid handling


  • Open Access

    AmbuBox: A Fast-Deployable Low-Cost Ventilator for COVID-19 Emergent Care

    by Zecong Fang, Andrew I. Li, Hongcheng Wang, Ruoyu Zhang, Xiyan Mai, Tingrui Pan


  • Digital droplet infusion

    by Zecong Fang, Andrew I. Li, Hong Liu, Tingrui Pan

    Infusion pumps have been widely used in clinical settings for the administration of medications and fluids. We present the digital droplet infusion (DDI) device, a low-cost, high-precision digital infusion system, utilizing a microfluidic discretization unit to convert continuous flow into precisely delivered droplet aliquots and a valving unit to control the duration and frequency of flow discretization. The DDI device relies on a distinct capillarity-dominated process of coalescence and pinch-off of droplets for flow digitization, which is monitored by a pair of conductive electrodes located before and after the junction. The digital feedback-controlled flow rate can be employed to adjust a solenoid valve for refined infusion management. With this unique digital microfluidic approach, the DDI technology enables a simple yet powerful infusion system with an ultrahigh resolution of digital droplet transfer volume, as small as 57 nL, which is three orders of magnitude lower than that of clinical standard infusion pumps, as well as a wide range of digitally adjustable infusion rates ranging from 0.1 mL h−1 to 10 mL h−1, in addition to an array of programmable infusion profiles and safety features. Its modular design enables fast assembly using only off-the-shelf and 3D-printed components. Overall, benefiting from its simple device architecture and excellent infusion performance, the DDI technology has great potential to become the next-generation clinical standard for drug delivery with its high precision and ultimate portability at a low cost.


  • Digital microfluidic meter-on-chip

    by Zecong Fang, Yi Ding, Zhichao Zhang, Fei Wang, Zuankai Wang, Hao Wang, Tingrui Pan

    The accurate monitoring and control of liquid flow at low flow rates have become increasingly important in contemporary biomedical research and industrial monitoring. Inspired by the drop-counting principle implemented in a clinical gravity drip, we propose a novel microfluidic flowmetry technology for polydimethylsiloxane (PDMS)-based conventional microfluidic devices, known as a microfluidic digital meter-on-chip (DMC), to achieve on-chip and localized microflow measurements with ultrahigh precision and a wide tunable range. The DMC technology primarily relies on capillarity, unlike a gravity drip, to induce a characteristic interfacial droplet pinch-off process, from which digital microflowmetry devices can discretize continuous flow into countable transferred liquid units with consistent quantifiable volumes. Enabled by the passive discretization principle and optical transparency, the DMC device requires no external energy input or bulky control equipment, and a non-contact wireless optical detection scheme using a smartphone can be conveniently used as a readout module. Moreover, the DMC technology achieves an ultrahigh flow-to-frequency sensitivity (6.59 Hz (μL min−1)−1) and resolution (droplet transfer volume down to 2.5 nL, nearly two orders of magnitude smaller than in previously reported work, resulting in ultralow flow rates of 1 μL min−1). In addition, the flow rate measurement range covers up to 80 μL min−1 and down to at least 150 nL min−1 (over 100 times lower than reported similar digital flowmetry on the same time scale) using the current device configuration. Benefiting from its simple device architecture and adaptability, the versatile DMC technology can be seamlessly integrated with various microfluidic and nanofluidic devices for drug delivery and biochemical analysis, serving as a promising technology platform for next-generation highly demanding microflow measurements.


  • Microfluidic cap-to-dispense (μCD): a universal microfluidic–robotic interface for automated pipette-free high-precision liquid handling

    by Jingjing Wang, Ka Deng, Chuqing Zhou, Zecong Fang, Conary Meyer, Kaustubh Umesh-Anjali Deshpande, Zhihao Li, Xianqiang Mi, Qian Luo, Bruce D. Hammock, et al.

    A novel microfluidic–robotic interface that is able to achieve automatic on-demand volume distribution ranging from nanoliter to microliter is introduced.


  • Digital flow rate sensor based on isovolumetric droplet discretization effect by a three-supersurface structure

    by Xuan Li, Yuxin Mao, Zhicheng Zhu, Yinghui Zhang, Zecong Fang, Dong Wu, Hang Ding, Tingrui Pan, Baoqing Li, Jiaru Chu