Priyanka Madhushri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Priyanka Madhushri has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Emil Jovanov
University of Alabama in Huntsville
6 shared publications - Aleksandar Milenkovic
The University of Alabama in Huntsville, Huntsville, AL, USA
4 shared publications - Vinod Kushvaha
Indian Institute of Technology Jammu
4 shared publications - Armen Dzhagaryan
Electrical and Computer Engineering Department, The University of Alabama in Huntsville, Huntsville, AL and U.S.A., --- Select a Country --
2 shared publications Insha Wani
Research Scholar, Dept. of Civil Engineering, Indian Institute of Technology, Jammu 181221, India
2 shared publicationsAanchna Sharma
Research Scholar, Dept. of Civil Engineering, Indian Institute of Technology, Jammu 181221, India
1 shared publication
Latest Publications
- 2 August 2022
- Published by Springer Nature
- p. 79-93
Dynamic Fracture Toughness Prediction of Fiber/Epoxy Composites Using K-Nearest Neighbor (KNN) Method
- 2 August 2022
- Published by Springer Nature
- p. 79-93
Dynamic Fracture Toughness Prediction of Fiber/Epoxy Composites Using K-Nearest Neighbor (KNN) Method
- 1 October 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Hazardous, Toxic, and Radioactive Waste
- Vol. 24 (4) , 04020048
Effect of pH, Volatile Content, and Pyrolysis Conditions on Surface Area and O/C and H/C Ratios of Biochar: Towards Understanding Performance of Biochar Using Simplified Approach
The objective of this study was to predict biochar properties [surface area and oxygen-to-carbon (O/C) and hydrogen-to-carbon (H/C) ratios] from pyrolysis conditions, volatile matter content, and pH using the k-nearest neighbor (KNN) algorithm. Such predictions were made for different types of biochar, derived from various sources, namely rice husks, rice straw, applewood chips, and oakwood. The relative significance of each parameter affecting the Brunauer–Emmett–Teller (BET) surface area, O/C ratio, and H/C ratio was reported. The BET surface area increased with an increase in temperature or pH but decreased with an increase in the volatile matter content. A relationship was identified between H/C ratio, biochar yield, volatile matter content, pH, temperature, and adsorption. According to the results obtained, volatile matter content was found to be the most significant parameter affecting H/C ratio, followed by temperature, adsorption, pH, and biochar yield but in the case of O/C ratio and surface area, adsorption was found to have the highest significance of all the parameters. Overall, this study is useful to estimate the performance of biochar (surface area, stability, and bonding ability). This will further help certain users (farmers, engineers, and soil and water remediation scientists) to refine the list of biochars suitable for their purpose without going through laborious and cost-intensive process of determining surface area and O/C and H/C ratios.
- 1 October 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Hazardous, Toxic, and Radioactive Waste
- Vol. 24 (4) , 04020048
Effect of pH, Volatile Content, and Pyrolysis Conditions on Surface Area and O/C and H/C Ratios of Biochar: Towards Understanding Performance of Biochar Using Simplified Approach
The objective of this study was to predict biochar properties [surface area and oxygen-to-carbon (O/C) and hydrogen-to-carbon (H/C) ratios] from pyrolysis conditions, volatile matter content, and pH using the k-nearest neighbor (KNN) algorithm. Such predictions were made for different types of biochar, derived from various sources, namely rice husks, rice straw, applewood chips, and oakwood. The relative significance of each parameter affecting the Brunauer–Emmett–Teller (BET) surface area, O/C ratio, and H/C ratio was reported. The BET surface area increased with an increase in temperature or pH but decreased with an increase in the volatile matter content. A relationship was identified between H/C ratio, biochar yield, volatile matter content, pH, temperature, and adsorption. According to the results obtained, volatile matter content was found to be the most significant parameter affecting H/C ratio, followed by temperature, adsorption, pH, and biochar yield but in the case of O/C ratio and surface area, adsorption was found to have the highest significance of all the parameters. Overall, this study is useful to estimate the performance of biochar (surface area, stability, and bonding ability). This will further help certain users (farmers, engineers, and soil and water remediation scientists) to refine the list of biochars suitable for their purpose without going through laborious and cost-intensive process of determining surface area and O/C and H/C ratios.
- 1 January 2020
- Published by IGI Global Scientific Publishing
- p. 1178-1192
Long-Term Synchronization of Hybrid Sensors Networks
This article presents synchronization of a hybrid distributed sensor network with wired and wireless sensors. Authors present an implementation of a sleep monitoring system as a hybrid sensor network that combines wireless inertial sensors controlled by a custom smartphone application as an extension of the polysomnographic (PSG) monitor to improve user's comfort. The authors developed an original method of synchronization of wireless sensor data with the PSG records using an auxiliary audio synchronization signal generated by the smartphone. The timestamps on the smartphone are synchronized with the timestamps from inertial sensors, and time of generated synchronization pulses recorded by the PSG. The individual data streams were synchronized using the Dynamic Time Warping (DTW) mechanism. Authors present the system organization and the results of analysis of the whole night monitoring, including the analysis of channel reliability and clock drift. Clock drift has been reduced from 10-30 seconds to 5.1± 3 milliseconds which is with an improved accuracy as compare to existing methods.
- 1 January 2020
- Published by IGI Global Scientific Publishing
- p. 1178-1192
Long-Term Synchronization of Hybrid Sensors Networks
This article presents synchronization of a hybrid distributed sensor network with wired and wireless sensors. Authors present an implementation of a sleep monitoring system as a hybrid sensor network that combines wireless inertial sensors controlled by a custom smartphone application as an extension of the polysomnographic (PSG) monitor to improve user's comfort. The authors developed an original method of synchronization of wireless sensor data with the PSG records using an auxiliary audio synchronization signal generated by the smartphone. The timestamps on the smartphone are synchronized with the timestamps from inertial sensors, and time of generated synchronization pulses recorded by the PSG. The individual data streams were synchronized using the Dynamic Time Warping (DTW) mechanism. Authors present the system organization and the results of analysis of the whole night monitoring, including the analysis of channel reliability and clock drift. Clock drift has been reduced from 10-30 seconds to 5.1± 3 milliseconds which is with an improved accuracy as compare to existing methods.
- 25 November 2019
- Published by Springer Nature in Acta Geophysica
- Vol. 68 (1) , 207-217
Mechanism of biochar soil pore–gas–water interaction: gas properties of biochar-amended sandy soil at different degrees of compaction using KNN modeling
- 25 November 2019
- Published by Springer Nature in Acta Geophysica
- Vol. 68 (1) , 207-217
Mechanism of biochar soil pore–gas–water interaction: gas properties of biochar-amended sandy soil at different degrees of compaction using KNN modeling
- 1 September 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (11) , 115342
Dynamic fracture toughness index: a new integrated methodology for mode-I fracture behaviour of polymer composite under impact loading
In the current work, a new term called dynamic fracture toughness index (KI index) for mode-I (crack opening mode) configuration is presented. This index is useful in determining the dynamic fracture toughness under different strain-rate conditions. (KI index) is evolved based on dimensional analysis of the parameters that govern high strain-rate impact loading conditions and offers an integrated methodology to characterize dynamic fracture behaviour which is validated for particulate polymer composites (PPCs). The validity of the developed methodology is corroborated with the dynamic fracture experimental data for varying volume fraction of glass fibers and as well as predicting the dynamic fracture toughness with limited number of experiments.
- 1 September 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (11) , 115342
Dynamic fracture toughness index: a new integrated methodology for mode-I fracture behaviour of polymer composite under impact loading
In the current work, a new term called dynamic fracture toughness index (KI index) for mode-I (crack opening mode) configuration is presented. This index is useful in determining the dynamic fracture toughness under different strain-rate conditions. (KI index) is evolved based on dimensional analysis of the parameters that govern high strain-rate impact loading conditions and offers an integrated methodology to characterize dynamic fracture behaviour which is validated for particulate polymer composites (PPCs). The validity of the developed methodology is corroborated with the dynamic fracture experimental data for varying volume fraction of glass fibers and as well as predicting the dynamic fracture toughness with limited number of experiments.
- 1 July 2018
- Published by IGI Global Scientific Publishing in International Journal of Embedded and Real-Time Communication Systems
- Vol. 9 (2) , 32-46
Long-Term Synchronization of Hybrid Sensors Networks
This article presents synchronization of a hybrid distributed sensor network with wired and wireless sensors. Authors present an implementation of a sleep monitoring system as a hybrid sensor network that combines wireless inertial sensors controlled by a custom smartphone application as an extension of the polysomnographic (PSG) monitor to improve user's comfort. The authors developed an original method of synchronization of wireless sensor data with the PSG records using an auxiliary audio synchronization signal generated by the smartphone. The timestamps on the smartphone are synchronized with the timestamps from inertial sensors, and time of generated synchronization pulses recorded by the PSG. The individual data streams were synchronized using the Dynamic Time Warping (DTW) mechanism. Authors present the system organization and the results of analysis of the whole night monitoring, including the analysis of channel reliability and clock drift. Clock drift has been reduced from 10-30 seconds to 5.1± 3 milliseconds which is with an improved accuracy as compare to existing methods.
- 1 July 2018
- Published by IGI Global Scientific Publishing in International Journal of Embedded and Real-Time Communication Systems
- Vol. 9 (2) , 32-46
Long-Term Synchronization of Hybrid Sensors Networks
This article presents synchronization of a hybrid distributed sensor network with wired and wireless sensors. Authors present an implementation of a sleep monitoring system as a hybrid sensor network that combines wireless inertial sensors controlled by a custom smartphone application as an extension of the polysomnographic (PSG) monitor to improve user's comfort. The authors developed an original method of synchronization of wireless sensor data with the PSG records using an auxiliary audio synchronization signal generated by the smartphone. The timestamps on the smartphone are synchronized with the timestamps from inertial sensors, and time of generated synchronization pulses recorded by the PSG. The individual data streams were synchronized using the Dynamic Time Warping (DTW) mechanism. Authors present the system organization and the results of analysis of the whole night monitoring, including the analysis of channel reliability and clock drift. Clock drift has been reduced from 10-30 seconds to 5.1± 3 milliseconds which is with an improved accuracy as compare to existing methods.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2017 (1557170X) , 2398-2401
A model based analysis of optimality of sit-to-stand transition
Objective assessment of mobility and effectiveness of interventions remains an open issue. Timed Up and Go (TUG) and 30 Second Chair Stand (30SCS) tests are routinely used in assessing mobility of subjects, but they provide a single parameter. Instrumenting subjects with wearable sensors enables a detailed mobility assessment. Specifically, we argue that instrumented sit-to-stand (S2ST) posture transitions during the TUG and 30SCS tests can be used to assess the strength and balance of subjects. In this paper we develop a personalized three-segment model that quantifies torques/forces on the body and assesses optimality of each sit-to-stand transition. To characterize a S2ST transition we calculate action defined as an integral of mechanical energy over time. The theoretical optimal transition time can thus be determined for each person by finding the minimum action necessary for a S2ST transition. Our model assesses action during the S2ST transition using inputs from smartphone's inertial sensors, and calculates optimum S2ST transition time for a given body composition of a subject. Our experimental evaluation shows that healthy young subjects have posture transition times close to the optimal transition time generated by the model. We hypothesize that the optimality of posture transition provides an objective and potentially more accurate estimation of the mobility. We tested the model by evaluating optimum action and optimum S2ST transition time for 10 geriatric patients undergoing a mobility improvement program by comparing their performance with the optimum performance generated by the model. This paper presents the model and possible use of the results to assess long-term changes in mobility of users.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2017 (1557170X) , 2398-2401
A model based analysis of optimality of sit-to-stand transition
Objective assessment of mobility and effectiveness of interventions remains an open issue. Timed Up and Go (TUG) and 30 Second Chair Stand (30SCS) tests are routinely used in assessing mobility of subjects, but they provide a single parameter. Instrumenting subjects with wearable sensors enables a detailed mobility assessment. Specifically, we argue that instrumented sit-to-stand (S2ST) posture transitions during the TUG and 30SCS tests can be used to assess the strength and balance of subjects. In this paper we develop a personalized three-segment model that quantifies torques/forces on the body and assesses optimality of each sit-to-stand transition. To characterize a S2ST transition we calculate action defined as an integral of mechanical energy over time. The theoretical optimal transition time can thus be determined for each person by finding the minimum action necessary for a S2ST transition. Our model assesses action during the S2ST transition using inputs from smartphone's inertial sensors, and calculates optimum S2ST transition time for a given body composition of a subject. Our experimental evaluation shows that healthy young subjects have posture transition times close to the optimal transition time generated by the model. We hypothesize that the optimality of posture transition provides an objective and potentially more accurate estimation of the mobility. We tested the model by evaluating optimum action and optimum S2ST transition time for 10 geriatric patients undergoing a mobility improvement program by comparing their performance with the optimum performance generated by the model. This paper presents the model and possible use of the results to assess long-term changes in mobility of users.
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 3117-3120
A Smartphone Application Suite for Assessing Mobility
Modern smartphones integrate a growing number of inertial and environmental sensors that can enable the development of new mobile health applications. In this paper we introduce a suite of smartphone applications for assessing mobility in elderly population. The suite currently includes applications that automate and quantify the following standardized medical tests for assessing mobility: Timed-Up-and-Go (TUG), 30 Seconds Chair Stand Test (30SCS), and a 4-stage Balance Test (4SBT). For each smartphone application we describe its functionality and a list of parameters extracted by processing signals from smartphone's inertial sensors. The paper shows the results from studies conducted on geriatric patients for TUG tests and from studies conducted in the laboratory on healthy subjects for 30SCS and 4SBT tests.
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 3117-3120
A Smartphone Application Suite for Assessing Mobility
Modern smartphones integrate a growing number of inertial and environmental sensors that can enable the development of new mobile health applications. In this paper we introduce a suite of smartphone applications for assessing mobility in elderly population. The suite currently includes applications that automate and quantify the following standardized medical tests for assessing mobility: Timed-Up-and-Go (TUG), 30 Seconds Chair Stand Test (30SCS), and a 4-stage Balance Test (4SBT). For each smartphone application we describe its functionality and a list of parameters extracted by processing signals from smartphone's inertial sensors. The paper shows the results from studies conducted on geriatric patients for TUG tests and from studies conducted in the laboratory on healthy subjects for 30SCS and 4SBT tests.
- Open Access
- 18 July 2016
- Published by MDPI AG in Information
- Vol. 7 (3) , 47
An mHealth Tool Suite for Mobility Assessment
The assessment of mobility and functional impairments in the elderly is important for early detection and prevention of fall conditions. Falls create serious threats to health by causing disabling fractures that reduce independence in the elderly. Moreover, they exert heavy economic burdens on society due to high treatment costs. Modern smartphones enable the development of innovative mobile health (mHealth) applications by integrating a growing number of inertial and environmental sensors along with the ever-increasing data processing and communication capabilities. Mobility assessment is one of the promising mHealth application domains. In this paper, we introduce a suite of smartphone applications for assessing mobility in the elderly population. The suite currently includes smartphone applications that automate and quantify the following standardized medical tests for assessing mobility: Timed Up and Go (TUG), 30-Second Chair Stand Test (30SCS), and 4-Stage Balance Test (4SBT). For each application, we describe its functionality and a list of parameters extracted by processing signals from smartphone’s inertial sensors. The paper shows the results from studies conducted on geriatric patients for TUG tests and from experiments conducted in the laboratory on healthy subjects for 30SCS and 4SBT tests.
- 18 July 2016
- Published by MDPI AG in Information
- Vol. 7 (3) , 47
Open AccessAn mHealth Tool Suite for Mobility Assessment
The assessment of mobility and functional impairments in the elderly is important for early detection and prevention of fall conditions. Falls create serious threats to health by causing disabling fractures that reduce independence in the elderly. Moreover, they exert heavy economic burdens on society due to high treatment costs. Modern smartphones enable the development of innovative mobile health (mHealth) applications by integrating a growing number of inertial and environmental sensors along with the ever-increasing data processing and communication capabilities. Mobility assessment is one of the promising mHealth application domains. In this paper, we introduce a suite of smartphone applications for assessing mobility in the elderly population. The suite currently includes smartphone applications that automate and quantify the following standardized medical tests for assessing mobility: Timed Up and Go (TUG), 30-Second Chair Stand Test (30SCS), and 4-Stage Balance Test (4SBT). For each application, we describe its functionality and a list of parameters extracted by processing signals from smartphone’s inertial sensors. The paper shows the results from studies conducted on geriatric patients for TUG tests and from experiments conducted in the laboratory on healthy subjects for 30SCS and 4SBT tests.