RMRichard McKinley

Richard McKinley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Richard McKinley has a total of 758 co-authors. Here are the top co-authors by number of shared publications:

  • Roland Wiest

    University Institute of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital

    24 shared publications
  • Roland Wiest

    Support Center for Advanced Neuroimaging (SCAN), University Institute of Diagnostic and Interventional Neuroradiology, University Hospital Bern, Switzerland

    12 shared publications
  • Mauricio Reyes

    ARTORG Centre for Biomedical Engineering Research, University of Bern, Bern, Switzerland

    11 shared publications
  • Raphael Meier

    Support Center for Advanced Neuroimaging, University Institute of Diagnostic and Interventional Neuroradiology, University Hospital Bern, Inselspital, University of Bern, Bern, Switzerland

    8 shared publications
  • Franca Wagner

    Support Center for Advanced Neuroimaging, University Institute for Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, Bern, Switzerland

    7 shared publications
  • Mauricio Reyes

    University of Bern

    7 shared publications

Latest Publications

  • Open Access

    Mitigating the Impact of MR Sequence Parameters: Increasing the Robustness of DL‐Based Cortical Thickness Estimates

    by Timo Blattner, David Romascano, Richard McKinley, Michael Rebsamen, Anke Salmen, Maximilian Pistor, Robert Hoepner, Roland Wiest, Piotr Radojewski, Christian Rummel, et al.

    Cortical thickness measurements from MRI are increasingly used as biomarkers for neurodegenerative disease progression. However, variations in MRI acquisition parameters, such as inversion time (TI) and repetition time (TR), which are common in clinical settings, can compromise the reliability and sensitivity of these measurements. We fine-tuned a deep-learning-based segmentation tool (DL+DiReCT) to reduce its dependence to image contrast variations by training it on simulated MPRAGE images derived from quantitative relaxation maps. Fine-tuning markedly reduced contrast sensitivity, with the Pearson correlation coefficient decreasing from − 0.644 $$ -0.644 $$ to 0.094 $$ 0.094 $$ . Evaluation on a synthetic atrophy dataset demonstrated that our model accurately replicated atrophy trends with minimal underestimation, outperforming FreeSurfer and SynthSeg. When applied to a dataset of relapsing–remitting multiple sclerosis (RRMS) patients, the fine-tuned model showed a substantial reduction in contrast sensitivity and maintained stable performance after controlling for covariates such as age, sex, field strength, and Expanded Disability Status Scale (EDSS) score. Overall, the proposed approach achieves robust contrast invariance without sacrificing sensitivity to cortical atrophy, offering a practical improvement for longitudinal and multi-center clinical studies.

  • Open Access

    Brain tissue polarimetry under simulated intraoperative conditions: Effects of edema and temperature

    by Éléa Gros, Ardit Sakiri, Stefano Moriconi, Arnas Jankauskas, David Hasler, Théotim Lucas, Richard McKinley, Theoni Maragkou, Tatiana Novikova, Philippe Schucht, et al.

    In neurosurgical oncology, maximizing tumor resection while preserving neurological function remains a critical challenge, particularly in glioma surgery where tumor borders are difficult to distinguish intraoperatively. Polarimetry-based imaging has emerged as a promising technique for visualizing white matter fiber tracts and differentiating healthy from neoplastic brain tissue. This study evaluates whether brain edema and temperature variations influence polarimetric parameters, potentially introducing noise and complicating intraoperative imaging. To model edema, fresh ex vivo calf brain samples were immersed in distilled water. Polarimetric parameters including depolarization, linear retardance, and the azimuth of the optical axis, were measured at multiple time points over three hours and a half using a wide-field imaging Mueller polarimetric setup. Results show that water absorption affects all polarimetric parameters and complicates fiber tract visualization. We also investigated whether temperature changes influenced polarimetric markers, but found no significant effect. These findings demonstrate that brain edema might alter polarimetric markers and act as a confounding factor in intraoperative imaging, potentially affecting tumor border visualization. The in vivo impact of brain edema remains unclear, and further studies are needed to refine polarimetric imaging for surgical guidance in glioma resection.

  • Discriminating Distal Ischemic Stroke from Seizure-Induced Stroke Mimics Using Dynamic Susceptibility Contrast MRI

    by Marijn Borghouts, Richard McKinley, Manuel Köstner, Josien Pluim, Roland Wiest, Ruisheng Su

  • Top Cited Papers
    Open Access

    Towards fair decentralized benchmarking of healthcare AI algorithms with the Federated Tumor Segmentation (FeTS) challenge

    by Maximilian Zenk, Ujjwal Baid, Sarthak Pati, Akis Linardos, Brandon Edwards, Micah Sheller, Patrick Foley, Alejandro Aristizabal, David Zimmerer, Alexey Gruzdev, et al.

    Computational competitions are the standard for benchmarking medical image analysis algorithms, but they typically use small curated test datasets acquired at a few centers, leaving a gap to the reality of diverse multicentric patient data. To this end, the Federated Tumor Segmentation (FeTS) Challenge represents the paradigm for real-world algorithmic performance evaluation. The FeTS challenge is a competition to benchmark (i) federated learning aggregation algorithms and (ii) state-of-the-art segmentation algorithms, across multiple international sites. Weight aggregation and client selection techniques were compared using a multicentric brain tumor dataset in realistic federated learning simulations, yielding benefits for adaptive weight aggregation, and efficiency gains through client sampling. Quantitative performance evaluation of state-of-the-art segmentation algorithms on data distributed internationally across 32 institutions yielded good generalization on average, albeit the worst-case performance revealed data-specific modes of failure. Similar multi-site setups can help validate the real-world utility of healthcare AI algorithms in the future.


  • Open Access

    Diffusion Imaging Protocol Heterogeneity Biases Ischemic Core Volume, Location, and Clinical Associations in Acute Stroke

    by Jonathan Rafael-Patiño, Elda Fischi-Gomez, Antoine Madrona, Veronica Ravano, Bénédicte Maréchal, Tobias Kober, Silvia Pistocchi, Alexander Salerno, Guillaume Saliou, Patrik Michel, et al.

    BACKGROUND: Diffusion-weighted magnetic resonance imaging is essential for diagnosing ischemic stroke and identifying targets for emergency revascularization. Apparent diffusion coefficient (ADC) maps derived from diffusion-weighted magnetic resonance imaging are commonly used to locate the infarct core, but they are not strictly quantitative and can vary across platforms and sites due to technical factors. This retrospective study was conducted to examine how differences in ADC map generation, resulting from varied protocols across platforms and sites, affect the determination of infarct core size, location, and related clinical outcomes in acute stroke. METHODS: In this retrospective study, 726 patients with acute anterior circulation stroke from a cohort of 1210 unique visits to the Lausanne University Hospital between May 2018 and January 2021 were selected, excluding patients with poor quality imaging or no magnetic resonance imaging or clinical information available. Diffusion-weighted magnetic resonance imaging data were used to generate ADC maps as they would appear from different protocols: 2 simulated with low- and medium-angular resolution (4 and 12 diffusion gradient directions) and 1 with high-angular resolution (20 directions). Using DEFUSE criteria and image postprocessing, ischemic cores were localized; core volume, location, and associations to the National Institutes of Health Stroke Scale and modified Rankin Scale scores were compared between the 2 imaging sequences. RESULTS: Significant differences were observed in the ADC distribution within white matter, particularly in the kurtosis and skewness, with the segmented infarct core volume being higher in protocols with reduced angular resolution compared with the 20-directions data (7.63 mL versus 3.78 mL). The volumetric differences persisted after correcting for age, sex, and type of intervention. Infarcted voxel’s locations varied significantly between the 2 protocols. This variability affected associations between infarct core volume and clinical scores, with lower associations observed for 4-direction data compared with 20-direction data for the National Institutes of Health Stroke Scale at admission and after 24 hours, and modified Rankin Scale after 3 months, further confirmed by multivariate regression. CONCLUSIONS: Imaging protocol heterogeneity leads to significant changes in the ADC distribution, ischemic core location, size, and association with clinical scores. Work is needed in standardizing imaging protocols to improve the reliability of ADC as an imaging biomarker in stroke management protocols to improve the reliability of ADC as an imaging biomarker in stroke management.


  • Open Access

    Physically Consistent Image Augmentation for Deep Learning in Mueller Matrix Polarimetry

    by Christopher Hahne, Omar Rodríguez-Núñez, Éléa Gros, Théotim Lucas, Ekkehard Hewer, Tatiana Novikova, Theoni Maragkou, Philippe Schucht, Richard McKinley

    Mueller matrix polarimetry captures essential information about polarized light interactions with a sample, presenting unique challenges for data augmentation in deep learning due to its distinct structure. While augmentations are an effective and affordable way to enhance dataset diversity and reduce overfitting, standard transformations like rotations and flips do not preserve the polarization properties in Mueller matrix images. To this end, we introduce a versatile simulation framework that applies physically consistent rotations and flips to Mueller matrices, tailored to maintain polarization fidelity. Our experimental results across multiple datasets reveal that conventional augmentations can lead to falsified results when applied to polarimetric data, underscoring the necessity of our physics-based approach. In our experiments, we first compare our polarization-specific augmentations against real-world captures to validate their physical consistency. We then apply these augmentations in a semantic segmentation task, achieving substantial improvements in model generalization and performance. This study underscores the necessity of physics-informed data augmentation for polarimetric imaging in deep learning (DL), paving the way for broader adoption and more robust applications across diverse research in the field. In particular, our framework unlocks the potential of DL models for polarimetric datasets with limited sample sizes. Our code implementation is available at github.com/hahnec/polar_augment.


  • Open Access

    Characterization of Polarimetric Properties in Various Brain Tumor Types Using Wide-Field Imaging Mueller Polarimetry

    by Romane Gros, Omar Rodriguez-Nunez, Leonard Felger, Stefano Moriconi, Richard McKinley, Angelo Pierangelo, Tatiana Novikova, Erik Vassella, Philippe Schucht, Ekkehard Hewer, et al.

    Neuro-oncological surgery is the primary brain cancer treatment, yet it faces challenges with gliomas due to their invasiveness and the need to preserve neurological function. Hence, radical resection is often unfeasible, highlighting the importance of precise tumor margin delineation to prevent neurological deficits and improve prognosis. Imaging Mueller polarimetry, an effective modality in various organ tissues, seems a promising approach for tumor delineation in neurosurgery. To further assess its use, we characterized the polarimetric properties by analysing 45 polarimetric measurements of 27 fresh brain tumor samples, including different tumor types with a strong focus on gliomas. Our study integrates a wide-field imaging Mueller polarimetric system and a novel neuropathology protocol, correlating polarimetric and histological data for accurate tissue identification. An image processing pipeline facilitated the alignment and overlay of polarimetric images and histological masks. Variations in depolarization values were observed for grey and white matter of brain tumor tissue, while differences in linear retardance were seen only within white matter of brain tumor tissue. Notably, we identified pronounced optical axis azimuth randomization within tumor regions. This study lays the foundation for machine learning-based brain tumor segmentation algorithms using polarimetric data, facilitating intraoperative diagnosis and decision making.


  • Open Access

    Leveraging SO(3)-steerable convolutions for pose-robust semantic segmentation in 3D medical data

    by Ivan Diaz, Mario Geiger, Richard Iain McKinley

    Convolutional neural networks (CNNs) allow for parameter sharing and translational equivariance by using convolutional kernels in their linear layers. By restricting these kernels to be SO(3)-steerable, CNNs can further improve parameter sharing and equivariance. These equivariant convolutional layers have several advantages over standard convolutional layers, including increased robustness to unseen poses, smaller network size, and improved sample efficiency. Despite this, most segmentation networks used in medical image analysis continue to rely on standard convolutional kernels. In this paper, we present a new family of segmentation networks that use equivariant voxel convolutions based on spherical harmonics. These SE(3)-equivariant volumetric segmentation networks, which are robust to data poses not seen during training, do not require rotation-based data augmentation during training. In addition, we demonstrate improved segmentation performance in MRI brain tumor and healthy brain structure segmentation tasks, with enhanced robustness to reduced amounts of training data and improved parameter efficiency. Code to reproduce our results, and to implement the equivariant segmentation networks for other tasks is available at http://github.com/SCAN-NRAD/e3nn_Unet.


  • Open Access

    Do you see what I see? Diffusion imaging protocol heterogeneity biases ischemic core volume, location, and clinical associations in acute stroke

    by Jonathan Rafael-Patiño, Elda Fischi-Gomez, Antoine Madrona, Veronica Ravano, Bénédicte Maréchal, Tobias Kober, Silvia Pistocchi, Alexander Salerno, Guillaume Saliou, Patrik Michel, et al.

    Purpose Diffusion-weighted magnetic resonance imaging (DWI) is essential for diagnosing ischemic stroke and identifying targets for emergency revascularization. Apparent diffusion coefficient (ADC) maps derived from DWI are commonly used to locate the infarct core, but they are not strictly quantitative and can vary across platforms and sites due to technical factors. This retrospective study was conducted to examine how differences in ADC map generation, resulting from varied protocols across platforms and sites, affect the determination of infarct core size, location, and related clinical outcomes in acute stroke. Methods In this retrospective study, 726 acute anterior circulation stroke patients admitted to the Lausanne University Hospital between May 2018 and January 2021 were selected. DWI data were used to generate ADC maps as they would appear from different protocols: two simulated with low and medium angular resolution (4 and 12 diffusion gradient directions) and one with high angular resolution (20 directions). Using a DEFUSE like criteria and image post-processing, ischemic cores were localized; core volume, location, and associations to National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) scores were compared between the two imaging sequences. Results Significant differences were observed in the ADC distribution within white matter, particularly in the kurtosis and skewness, with the segmented infarct core volume being higher in protocols with reduced angular resolution compared to the 20-directions data (7.63 ml vs. 3.78 ml). The volumetric differences persisted after correcting for age, sex, and type of intervention. Infarcted voxels locations varied significantly between the two protocols. This variability affected associations between infarct core volume and clinical scores, with lower associations observed for 4-directions data compared to 20-directions data for NIHSS at admission and after 24 hours, and mRS after 3 months, further confirmed by multivariate regression. Conclusions Imaging protocol heterogeneity leads to significant changes in the ADC distribution, ischemic core location, size, and association with clinical scores. Work is needed in standardizing imaging protocols to improve the reliability of ADC as an imaging biomarker in stroke management.protocols to improve the reliability of ADC as an imaging biomarker in stroke management. Key Results Orientation changes in diffusion imaging significantly impact ADC distribution and threshold-based infarct core volume determination, affecting multi-centric studies. Lower number of directions in DWI acquisitions weakens associations between infarct volume measurements and clinical scores. Findings emphasize the impact of DWI acquisition protocol heterogeneity and image processing on acute stroke workups.


  • Open Access

    Near-real-time Mueller polarimetric image processing for neurosurgical intervention

    by Stefano Moriconi, Omar Rodríguez-Núñez, Romain Gros, Leonard A Felger, Theoni Maragkou, Ekkehard Hewer, Angelo Pierangelo, Tatiana Novikova, Philippe Schucht, Richard McKinley

    Purpose: Wide-field imaging Mueller polarimetry is a revolutionary, label-free, and non-invasive modality for computer-aided intervention; in neurosurgery, it aims to provide visual feedback of white matter fibre bundle orientation from derived parameters. Conventionally, robust polarimetric parameters are estimated after averaging multiple measurements of intensity for each pair of probing and detected polarised light. Long multi-shot averaging, however, is not compatible with real-time in vivo imaging, and the current performance of polarimetric data processing hinders the translation to clinical practice. Methods: A learning-based denoising framework is tailored for fast, single-shot, noisy acquisitions of polarimetric intensities. Also, performance-optimised image processing tools are devised for the derivation of clinically relevant parameters. The combination recovers accurate polarimetric parameters from fast acquisitions with near-real-time performance, under the assumption of pseudo-Gaussian polarimetric acquisition noise. Results: The denoising framework is trained, validated, and tested on experimental data comprising tumour-free and diseased human brain samples in different conditions. Accuracy and image quality indices showed significant ( $$p < 0.05$$ p < 0.05 ) improvements on testing data for a fast single-pass denoising versus the state-of-the-art and high polarimetric image quality standards. The computational time is reported for the end-to-end processing. Conclusion: The end-to-end image processing achieved real-time performance for a localised field of view ( $$\approx 6.5\ \text {mm}^2$$ ≈ 6.5 mm 2 ). The denoised polarimetric intensities produced visibly clear directional patterns of neuronal fibre tracts in line with reference polarimetric image quality standards; directional disruption was kept in case of neoplastic lesions. The presented advances pave the way towards feasible oncological neurosurgical translations of novel, label-free, interventional feedback.