Beni Adi Trisna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Beni Adi Trisna has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Jeongsoon Lee
Semiconductor and Display Metrology Group, Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea
6 shared publications Seungnam Park
National Centre of Standard Reference Data (NCSRD), Korea Research Institute of Standards and Science (KRISS), Daejeon, Republic of Korea
4 shared publicationsGhufron Zaid
The National Standardization Agency of Indonesia, Pusrisbang-BSN (formerly RCM-LIPI)
3 shared publicationsInjun Park
Interface Materials and Chemical Engineering Research Centre, Korea Research Institute of Chemical Technology (KRICT), Daejeon 34114, Republic of Korea
3 shared publications- Jeong Sik Lim
Greenhouse Gas Metrology team, Korea Research Institute of Standard and Science (KRISS), Science of Measurement, University of Science and Technology (UST), Daejeon, 34113, Republic of Korea
3 shared publications - Sang Woo Kim
Greenhouse Gas Metrology team, Korea Research Institute of Standard and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea
3 shared publications
Latest Publications
- 17 April 2025
- Published by Springer Nature in Asia-Pacific Journal of Atmospheric Sciences
- Vol. 61 (2) , 1-17
Instrument Line Shape Calibration and Comparison with TCCON Measurements for Greenhouse Gas Monitoring at a New COCCON Site in Korea
- 17 April 2025
- Published by Springer Nature in Asia-Pacific Journal of Atmospheric Sciences
- Vol. 61 (2) , 1-17
Instrument Line Shape Calibration and Comparison with TCCON Measurements for Greenhouse Gas Monitoring at a New COCCON Site in Korea
- Open Access
- 4 November 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-31
Preparation of hybrid calibrated absorption cross sections for a compact UV-DOAS measurement
A low-cost differential optical absorption spectroscopy (DOAS) spectrometer has been calibrated using a hybrid approach in which multiple absorption cross sections (ACSs) are measured and compared with previously obtained ACSs. The ACSs obtained from the measurement in this study are referred to as precise measurement (PM) ACSs, while those obtained from the simulation are referred to as hybrid simulation (HS) ACSs. The compact UV grating spectrometer was used to measure PM ACSs at different pressures and temperatures ranging from 295.75 K to 298.15 K. The spectral range was 230–320 nm with a spectral resolution of 0.28–0.39 nm. Uncertainties were evaluated and traceable to SI units. The relative standard measurement uncertainty of the PM ACS for o-xylene, p-xylene, SO2, benzene, styrene and toluene were 3.1 %, 3.1 %, 3.1 %, 3.0 %, 3.0 % and 2.9 %. respectively. This combined relative standard uncertainty includes contributions from optical path length (1.4 %), CRM concentration (≤0.74 %), absorbance repeatability (≤1.5 %), pressure (0.78 %) and temperature (2.1 %). ACSs for reactive trace gases without CRMs were derived using the HS method. This involved convolving literature spectra with measured instrumental functions (IFs) and subsequently applying spectral fitting to achieve ACSs that are well-aligned with those that would be obtained if measured with this spectrometer. The uncertainty of the HS ACSs results from the referenced ACSs, the determination of the IFs and the fitting procedures. The uncertainty of the referenced ACSs is taken directly from the literature and ranges from 0.05 % for benzaldehyde and formaldehyde to 5 % for oxygen. The uncertainty of the IFs is 0.67 %, 0.74 % and 0.65 % in regions I, II and III respectively. The total uncertainty for HS ACS is estimated to be 0.25 % for benzaldehyde, 1.01 % for NO2, 0.95 % for formaldehyde, 0.75 % for p-cresol, 0.74 % for m-xylene, 4.13 % for phenol, 4.19 % for ethylbenzene, 2.83 % for ozone in region I, 3.51 % for ozone in region II, 5.24 % for oxygen in region I and 5.31 % for oxygen in region II, taking into account the above uncertainty components. In a laboratory measurement of a gas mixture (benzene, toluene and ortho-xylene), the difference between the measurement values of the certified reference material (CRM) produced by the gravimetric method and the DOAS measurement is 8.5 % for benzene, 1.6 % for toluene and 4.9 % for ortho-xylene. Therefore, the uncertainty of the DOAS system was estimated to be 15.2 % for benzene, 8.2 % for toluene and 11.6 % for o-xylene, taking into account the uncertainties of the ACS (≤3.1 %), the fitting procedure (≤0.6 %), the difference with the CRM value (≤8.5 %) and the path length (1.4 %). In general, the system is ready for use in field measurements using the long-path DOAS technique.
- 4 November 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-31
Open AccessPreparation of hybrid calibrated absorption cross sections for a compact UV-DOAS measurement
A low-cost differential optical absorption spectroscopy (DOAS) spectrometer has been calibrated using a hybrid approach in which multiple absorption cross sections (ACSs) are measured and compared with previously obtained ACSs. The ACSs obtained from the measurement in this study are referred to as precise measurement (PM) ACSs, while those obtained from the simulation are referred to as hybrid simulation (HS) ACSs. The compact UV grating spectrometer was used to measure PM ACSs at different pressures and temperatures ranging from 295.75 K to 298.15 K. The spectral range was 230–320 nm with a spectral resolution of 0.28–0.39 nm. Uncertainties were evaluated and traceable to SI units. The relative standard measurement uncertainty of the PM ACS for o-xylene, p-xylene, SO2, benzene, styrene and toluene were 3.1 %, 3.1 %, 3.1 %, 3.0 %, 3.0 % and 2.9 %. respectively. This combined relative standard uncertainty includes contributions from optical path length (1.4 %), CRM concentration (≤0.74 %), absorbance repeatability (≤1.5 %), pressure (0.78 %) and temperature (2.1 %). ACSs for reactive trace gases without CRMs were derived using the HS method. This involved convolving literature spectra with measured instrumental functions (IFs) and subsequently applying spectral fitting to achieve ACSs that are well-aligned with those that would be obtained if measured with this spectrometer. The uncertainty of the HS ACSs results from the referenced ACSs, the determination of the IFs and the fitting procedures. The uncertainty of the referenced ACSs is taken directly from the literature and ranges from 0.05 % for benzaldehyde and formaldehyde to 5 % for oxygen. The uncertainty of the IFs is 0.67 %, 0.74 % and 0.65 % in regions I, II and III respectively. The total uncertainty for HS ACS is estimated to be 0.25 % for benzaldehyde, 1.01 % for NO2, 0.95 % for formaldehyde, 0.75 % for p-cresol, 0.74 % for m-xylene, 4.13 % for phenol, 4.19 % for ethylbenzene, 2.83 % for ozone in region I, 3.51 % for ozone in region II, 5.24 % for oxygen in region I and 5.31 % for oxygen in region II, taking into account the above uncertainty components. In a laboratory measurement of a gas mixture (benzene, toluene and ortho-xylene), the difference between the measurement values of the certified reference material (CRM) produced by the gravimetric method and the DOAS measurement is 8.5 % for benzene, 1.6 % for toluene and 4.9 % for ortho-xylene. Therefore, the uncertainty of the DOAS system was estimated to be 15.2 % for benzene, 8.2 % for toluene and 11.6 % for o-xylene, taking into account the uncertainties of the ACS (≤3.1 %), the fitting procedure (≤0.6 %), the difference with the CRM value (≤8.5 %) and the path length (1.4 %). In general, the system is ready for use in field measurements using the long-path DOAS technique.
- Open Access
- 30 November 2023
- Published by Elsevier in International Journal of Refrigeration
- Vol. 158, 135-143
Comprehensive analysis of refrigerant R134a: Implications for estimating and managing greenhouse gas emissions
- 30 November 2023
- Published by Elsevier in International Journal of Refrigeration
- Vol. 158, 135-143
Open AccessComprehensive analysis of refrigerant R134a: Implications for estimating and managing greenhouse gas emissions
- Open Access
- 14 April 2023
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 23 (7) , 4489-4500
Measurement report: Radiative efficiencies of (CF3)2CFCN, CF3OCFCF2, and CF3OCF2CF3
Absorption cross sections of emerging greenhouse gases (GHGs) were measured to estimate the radiative efficiency using high-resolution Fourier transform infrared spectroscopy (HR-FTIR). For quantitative spectroscopy, the Beer–Lambert parameters of absorber pressure, temperature, and optical path length (OPL) were accurately determined to be traceable to the primary standards. The OPL of the multipass cell mounted on the HR-FTIR spectrometer was spectroscopically calibrated. A ratio of the averaged N2O absorptions was found to be in the range of 2217.4–2219.0 cm−1, with a spectral resolution of 0.026 cm−1, yielding a ratio of OPLs between the multipass cell and reference cell. This cell-to-cell comparison method is free from the uncertainty of the referring line strength, which reduced the calibration uncertainty compared with the direct line-strength referring method. With the OPL-calibrated multipass cell (3.169 ± 0.079 m), the absorption cross sections were measured at low absorber pressures with a spectral resolution of 2 cm−1, integrated at 10 cm−1 intervals, and multiplied by the new narrow band model to yield the radiative efficiencies. The radiative efficiency values of CF4, SF6, and NF3 were evaluated to be 0.085 ± 0.002, 0.573 ± 0.016, and 0.195 ± 0.008 W m−2 ppb−1, respectively, which are consistent with previously reported values. For the emerging GHGs, the radiative efficiency values were determined to be 0.201 ± 0.008 W m−2 ppb−1 for heptafluoroisobutyronitrile (CF3)2CFCN; commercially referred to as Novec-4710), 0.328 ± 0.013 W m−2 ppb−1 for perfluoro methyl vinyl ether (CF3OCFCF2; PMVE), and 0.544 ± 0.022 W m−2 ppb−1 for 1,1,1,2,2-pentafluoro-2-(trifluoromethoxy)ethane (CF3OCF2CF3; PFMEE).
- 14 April 2023
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 23 (7) , 4489-4500
Open AccessMeasurement report: Radiative efficiencies of (CF3)2CFCN, CF3OCFCF2, and CF3OCF2CF3
Absorption cross sections of emerging greenhouse gases (GHGs) were measured to estimate the radiative efficiency using high-resolution Fourier transform infrared spectroscopy (HR-FTIR). For quantitative spectroscopy, the Beer–Lambert parameters of absorber pressure, temperature, and optical path length (OPL) were accurately determined to be traceable to the primary standards. The OPL of the multipass cell mounted on the HR-FTIR spectrometer was spectroscopically calibrated. A ratio of the averaged N2O absorptions was found to be in the range of 2217.4–2219.0 cm−1, with a spectral resolution of 0.026 cm−1, yielding a ratio of OPLs between the multipass cell and reference cell. This cell-to-cell comparison method is free from the uncertainty of the referring line strength, which reduced the calibration uncertainty compared with the direct line-strength referring method. With the OPL-calibrated multipass cell (3.169 ± 0.079 m), the absorption cross sections were measured at low absorber pressures with a spectral resolution of 2 cm−1, integrated at 10 cm−1 intervals, and multiplied by the new narrow band model to yield the radiative efficiencies. The radiative efficiency values of CF4, SF6, and NF3 were evaluated to be 0.085 ± 0.002, 0.573 ± 0.016, and 0.195 ± 0.008 W m−2 ppb−1, respectively, which are consistent with previously reported values. For the emerging GHGs, the radiative efficiency values were determined to be 0.201 ± 0.008 W m−2 ppb−1 for heptafluoroisobutyronitrile (CF3)2CFCN; commercially referred to as Novec-4710), 0.328 ± 0.013 W m−2 ppb−1 for perfluoro methyl vinyl ether (CF3OCFCF2; PMVE), and 0.544 ± 0.022 W m−2 ppb−1 for 1,1,1,2,2-pentafluoro-2-(trifluoromethoxy)ethane (CF3OCF2CF3; PFMEE).
- Open Access
- 6 January 2023
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 48 (35) , 13012-13023
Development of a hydrogen impurity analyzer based on mobile-gas chromatography for online hydrogen fuel monitoring
- 6 January 2023
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 48 (35) , 13012-13023
Open AccessDevelopment of a hydrogen impurity analyzer based on mobile-gas chromatography for online hydrogen fuel monitoring
- Open Access
- 7 November 2022
- Published by Copernicus GmbH in EGUsphere
- Vol. 2022, 1-19
Measurement report: Radiative efficiency estimates of (CF3)2CFCN, CF3OCFCF2, and CF3OCF2CF3 using high-resolution Fourier transform infrared spectroscopy
Absorption cross-sections (ACS) of emerging greenhouse gases (GHG) were measured to estimate the radiative efficiencies (RE) using high-resolution Fourier transform infrared spectroscopy (HR-FTIR). For quantitative spectroscopy, the Beer–Lambert parameters of absorber pressure, temperature, and optical pass length (OPL) have been accurately determined to be traceable to the primary standards. The OPL of the multipass cell (MP) mounted on the HR-FTIR spectrometer was spectroscopically calibrated. A ratio of the averaged N2O absorptions was measured in the range of 2,217.4–2,219.0 cm-1 with a spectral resolution of 0.026 cm-1, yielding a ratio of OPLs between the MP and reference cell (RC). This cell-to-cell comparison (CC) method does not include the uncertainty in the referring line strength, thereby reducing the calibration uncertainty compared with a direct line-strength referring method. With the OPL-calibrated MP (3.169 ± 0.079 m), the ACSs were measured at low absorber pressures with a spectral resolution of 2 cm-1, integrated at 10 cm-1 intervals, and multiplied by the new narrow band model to yield the RE values. The RE values of the classic GHGs CF4, SF6, and NF3 were evaluated to be 0.085 ± 0.002, 0.573 ± 0.016, and 0.195 ± 0.008 W m-2 ppb-1, respectively, which are consistent with previously reported values. For the emerging GHGs, the RE values were determined to be 0.201 ± 0.008 W m-2 ppb-1 for (CF3)2CFCN (heptafluoroisobutyronitrile, commercially referred to as Novec-4710), 0.328 ± 0.013 W m-2 ppb-1 for CF3OCFCF2 (perfluoro methyl vinyl ether, PMVE), and 0.544 ± 0.022 W m-2 ppb-1 for CF3OCF2CF3 (1,1,1,2,2-pentafluoro-2-(trifluoromethoxy)ethane, PFMEE).
- 7 November 2022
- Published by Copernicus GmbH in EGUsphere
- Vol. 2022, 1-19
Open AccessMeasurement report: Radiative efficiency estimates of (CF3)2CFCN, CF3OCFCF2, and CF3OCF2CF3 using high-resolution Fourier transform infrared spectroscopy
Absorption cross-sections (ACS) of emerging greenhouse gases (GHG) were measured to estimate the radiative efficiencies (RE) using high-resolution Fourier transform infrared spectroscopy (HR-FTIR). For quantitative spectroscopy, the Beer–Lambert parameters of absorber pressure, temperature, and optical pass length (OPL) have been accurately determined to be traceable to the primary standards. The OPL of the multipass cell (MP) mounted on the HR-FTIR spectrometer was spectroscopically calibrated. A ratio of the averaged N2O absorptions was measured in the range of 2,217.4–2,219.0 cm-1 with a spectral resolution of 0.026 cm-1, yielding a ratio of OPLs between the MP and reference cell (RC). This cell-to-cell comparison (CC) method does not include the uncertainty in the referring line strength, thereby reducing the calibration uncertainty compared with a direct line-strength referring method. With the OPL-calibrated MP (3.169 ± 0.079 m), the ACSs were measured at low absorber pressures with a spectral resolution of 2 cm-1, integrated at 10 cm-1 intervals, and multiplied by the new narrow band model to yield the RE values. The RE values of the classic GHGs CF4, SF6, and NF3 were evaluated to be 0.085 ± 0.002, 0.573 ± 0.016, and 0.195 ± 0.008 W m-2 ppb-1, respectively, which are consistent with previously reported values. For the emerging GHGs, the RE values were determined to be 0.201 ± 0.008 W m-2 ppb-1 for (CF3)2CFCN (heptafluoroisobutyronitrile, commercially referred to as Novec-4710), 0.328 ± 0.013 W m-2 ppb-1 for CF3OCFCF2 (perfluoro methyl vinyl ether, PMVE), and 0.544 ± 0.022 W m-2 ppb-1 for CF3OCF2CF3 (1,1,1,2,2-pentafluoro-2-(trifluoromethoxy)ethane, PFMEE).
- 30 October 2019
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 25 (1) , 1-5
Results of a proficiency testing on the calibration of clinical liquid-in-glass thermometer
- 30 October 2019
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 25 (1) , 1-5
Results of a proficiency testing on the calibration of clinical liquid-in-glass thermometer
- Open Access
- 1 August 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1065 (12) , 122001
Effect of Electrical Annealing to the Inhomogeneity Improvement of Type-S Thermocouples
The thermoelectric inhomogeneity as a function of position along wires is one the significant uncertainty of measurement using thermocouples. Here we report development of an electrical annealing system for thermoelectric inhomogeneity treatment. Two inhomogeneous type-S thermocouples, which had the inhomogeneity greater than 0.04%emf, are successfully recovered using the system. An improvement on thermocouple performance as large as 0.28 °C (at temperature of 1000 °C) can be obtained using the system. This article provides detailed information and may help the reader to obtain a quick grasp about the system.
- 1 August 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1065 (12) , 122001
Open AccessEffect of Electrical Annealing to the Inhomogeneity Improvement of Type-S Thermocouples
The thermoelectric inhomogeneity as a function of position along wires is one the significant uncertainty of measurement using thermocouples. Here we report development of an electrical annealing system for thermoelectric inhomogeneity treatment. Two inhomogeneous type-S thermocouples, which had the inhomogeneity greater than 0.04%emf, are successfully recovered using the system. An improvement on thermocouple performance as large as 0.28 °C (at temperature of 1000 °C) can be obtained using the system. This article provides detailed information and may help the reader to obtain a quick grasp about the system.
- 16 July 2018
- Published by Springer Nature in MAPAN
- Vol. 33 (4) , 469-480
Current Situation and Prospect of Nanometrology and its Standardization in Indonesia
- 16 July 2018
- Published by Springer Nature in MAPAN
- Vol. 33 (4) , 469-480
Current Situation and Prospect of Nanometrology and its Standardization in Indonesia