David W. Koppenaal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David W. Koppenaal has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Edward D. Hoegg
Department of Chemistry, Biosystems Research Complex Clemson University Clemson South Carolina USA
4 shared publications - Richard Kenneth Marcus
Department of Chemistry, Biosystems Research Complex Clemson University Clemson South Carolina USA
4 shared publications - Ljiljana Paša-Tolić
Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99354, USA
2 shared publications - Tyler J. Williams
Clemson University, Department of Chemistry, Clemson, USA
2 shared publications - Akos Vertes
Department of Chemistry, The George Washington University, Washington, DC 20052, USA
1 shared publication - Beverly J. Agtuca
Divisions of Plant Sciences and Biochemistry, Christopher S. Bond Life Sciences Center, University of Missouri, Columbia, Missouri 65211, United States
1 shared publication
Latest Publications
- 4 August 2021
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 42 (2) , 652-673
Combined atomic and molecular (CAM) ionization with the liquid sampling‐atmospheric pressure glow discharge microplasma
In a world where information‐rich methods of analysis are often sought over those with superior figures of merit, there is a constant search for ionization methods which can be applied across diverse analytical systems. The liquid sampling‐atmospheric pressure glow discharge (LS‐APGD) is a microplasma device which has the inherent capabilities to operate as a combined atomic and molecular (CAM) ionization source. The plasma is sustained by placement of a high voltage (~500 V, dc) onto an electrolytic solution through which the analyte is generally delivered to the discharge. Judicious choice of the solvent provides a means of obtaining atomic/elemental and/or molecular mass spectra. Presented here are the diverse modes of sample introduction and mass spectrometer platforms to which the LS‐APGD has been interfaced. Likewise, representative spectra and figures of merit are presented towards elemental and isotope ratio measurements, as well as application to small organic molecules, organometallic complexes, and intact proteins. It is believed that the diversity of analytical applications and ready implementation across the entirety of mass spectrometry platforms portends a level of versatility not realized with other ionization sources.
- 4 August 2021
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 42 (2) , 652-673
Combined atomic and molecular (CAM) ionization with the liquid sampling‐atmospheric pressure glow discharge microplasma
In a world where information‐rich methods of analysis are often sought over those with superior figures of merit, there is a constant search for ionization methods which can be applied across diverse analytical systems. The liquid sampling‐atmospheric pressure glow discharge (LS‐APGD) is a microplasma device which has the inherent capabilities to operate as a combined atomic and molecular (CAM) ionization source. The plasma is sustained by placement of a high voltage (~500 V, dc) onto an electrolytic solution through which the analyte is generally delivered to the discharge. Judicious choice of the solvent provides a means of obtaining atomic/elemental and/or molecular mass spectra. Presented here are the diverse modes of sample introduction and mass spectrometer platforms to which the LS‐APGD has been interfaced. Likewise, representative spectra and figures of merit are presented towards elemental and isotope ratio measurements, as well as application to small organic molecules, organometallic complexes, and intact proteins. It is believed that the diversity of analytical applications and ready implementation across the entirety of mass spectrometry platforms portends a level of versatility not realized with other ionization sources.
- 13 July 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (9) , 1969-1978
A multi-electrode glow discharge ionization source for atomic and molecular mass spectrometry
A novel multi-electrode glow discharge provides increased sensitivity and analytical flexibility for both atomic and molecular MS determinations.
- 13 July 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (9) , 1969-1978
A multi-electrode glow discharge ionization source for atomic and molecular mass spectrometry
A novel multi-electrode glow discharge provides increased sensitivity and analytical flexibility for both atomic and molecular MS determinations.
- Open Access
- 1 February 2020
- Published by Scientific Societies in Molecular Plant-Microbe Interactions®
- Vol. 33 (2) , 272-283
In-Situ Metabolomic Analysis of Setaria viridis Roots Colonized by Beneficial Endophytic Bacteria
Over the past decades, crop yields have risen in parallel with increasing use of fossil fuel–derived nitrogen (N) fertilizers but with concomitant negative impacts on climate and water resources. There is a need for more sustainable agricultural practices, and biological nitrogen fixation (BNF) could be part of the solution. A variety of nitrogen-fixing, epiphytic, and endophytic plant growth–promoting bacteria (PGPB) are known to stimulate plant growth. However, compared with the rhizobium-legume symbiosis, little mechanistic information is available as to how PGPB affect plant metabolism. Therefore, we investigated the metabolic changes in roots of the model grass species Setaria viridis upon endophytic colonization by Herbaspirillum seropedicae SmR1 (fix+) or a fix− mutant strain (SmR54) compared with uninoculated roots. Endophytic colonization of the root is highly localized and, hence, analysis of whole-root segments dilutes the metabolic signature of those few cells impacted by the bacteria. Therefore, we utilized in-situ laser ablation electrospray ionization mass spectrometry to sample only those root segments at or adjacent to the sites of bacterial colonization. Metabolites involved in purine, zeatin, and riboflavin pathways were significantly more abundant in inoculated plants, while metabolites indicative of nitrogen, starch, and sucrose metabolism were reduced in roots inoculated with the fix− strain or uninoculated, presumably due to N limitation. Interestingly, compounds, involved in indole-alkaloid biosynthesis were more abundant in the roots colonized by the fix− strain, perhaps reflecting a plant defense response.
- 1 February 2020
- Published by Scientific Societies in Molecular Plant-Microbe Interactions®
- Vol. 33 (2) , 272-283
Open AccessIn-Situ Metabolomic Analysis of Setaria viridis Roots Colonized by Beneficial Endophytic Bacteria
Over the past decades, crop yields have risen in parallel with increasing use of fossil fuel–derived nitrogen (N) fertilizers but with concomitant negative impacts on climate and water resources. There is a need for more sustainable agricultural practices, and biological nitrogen fixation (BNF) could be part of the solution. A variety of nitrogen-fixing, epiphytic, and endophytic plant growth–promoting bacteria (PGPB) are known to stimulate plant growth. However, compared with the rhizobium-legume symbiosis, little mechanistic information is available as to how PGPB affect plant metabolism. Therefore, we investigated the metabolic changes in roots of the model grass species Setaria viridis upon endophytic colonization by Herbaspirillum seropedicae SmR1 (fix+) or a fix− mutant strain (SmR54) compared with uninoculated roots. Endophytic colonization of the root is highly localized and, hence, analysis of whole-root segments dilutes the metabolic signature of those few cells impacted by the bacteria. Therefore, we utilized in-situ laser ablation electrospray ionization mass spectrometry to sample only those root segments at or adjacent to the sites of bacterial colonization. Metabolites involved in purine, zeatin, and riboflavin pathways were significantly more abundant in inoculated plants, while metabolites indicative of nitrogen, starch, and sucrose metabolism were reduced in roots inoculated with the fix− strain or uninoculated, presumably due to N limitation. Interestingly, compounds, involved in indole-alkaloid biosynthesis were more abundant in the roots colonized by the fix− strain, perhaps reflecting a plant defense response.
- 28 May 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (7) , 1387-1395
Coupling of an atmospheric pressure microplasma ionization source with an Orbitrap Fusion Lumos Tribrid 1M mass analyzer for ultra-high resolution isotopic analysis of uranium
The coupling of a combined atomic and molecular (CAM) ionization source, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to an Orbitrap Fusion Lumos Tribrid 1M mass spectrometer is described as a significant step towards the elimination of isobaric interferences in elemental/isotopic mass spectrometry. The developed setup permits broadband, elemental mass spectra to be easily acquired at a mass resolution (m/Δm) of 500 000. A new ion source housing and integrated control system provide enhanced stability and sensitivity of the microplasma ion source in comparison to the previous designs. Detailed evaluation of the ion sampling parameters provided insight into differences with other Orbitrap platforms leading to a 5-fold increase in resolution in elemental/isotopic analysis. The roles of data acquisition/ion processing parameters were evaluated with regards to the precision and accuracy of 235U/238U isotope ratios. Significantly, the precision of those measurements improves as a function of pre-set mass resolution up to a value of 1 000 000, where a precision of 0.086% RSD is obtained for uranium concentrations of 100 ng mL−1. Analytical response curves (log–log), acquired for the two uranium isotopes at a resolution of 120 000 were linear (R2 = 0.9969) over more than 5 orders of magnitude, with limits of detection of 1 pg mL−1 for U. Based on 60 μL injection volumes, this represents a mass of 70 fg 235U. These figures of merit satisfy International Target Values (ITVs) for Measurement Uncertainties in Safeguarding Nuclear Materials set by the International Atomic Energy Agency (IAEA). Ultimately, and totally unique from beam-type instruments, the move to the higher-resolution Orbitrap platform provides all of the benefits of high mass resolution, with no penalties in sensitivity, precision, or dynamic range for uranium analysis.
- 28 May 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (7) , 1387-1395
Coupling of an atmospheric pressure microplasma ionization source with an Orbitrap Fusion Lumos Tribrid 1M mass analyzer for ultra-high resolution isotopic analysis of uranium
The coupling of a combined atomic and molecular (CAM) ionization source, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to an Orbitrap Fusion Lumos Tribrid 1M mass spectrometer is described as a significant step towards the elimination of isobaric interferences in elemental/isotopic mass spectrometry. The developed setup permits broadband, elemental mass spectra to be easily acquired at a mass resolution (m/Δm) of 500 000. A new ion source housing and integrated control system provide enhanced stability and sensitivity of the microplasma ion source in comparison to the previous designs. Detailed evaluation of the ion sampling parameters provided insight into differences with other Orbitrap platforms leading to a 5-fold increase in resolution in elemental/isotopic analysis. The roles of data acquisition/ion processing parameters were evaluated with regards to the precision and accuracy of 235U/238U isotope ratios. Significantly, the precision of those measurements improves as a function of pre-set mass resolution up to a value of 1 000 000, where a precision of 0.086% RSD is obtained for uranium concentrations of 100 ng mL−1. Analytical response curves (log–log), acquired for the two uranium isotopes at a resolution of 120 000 were linear (R2 = 0.9969) over more than 5 orders of magnitude, with limits of detection of 1 pg mL−1 for U. Based on 60 μL injection volumes, this represents a mass of 70 fg 235U. These figures of merit satisfy International Target Values (ITVs) for Measurement Uncertainties in Safeguarding Nuclear Materials set by the International Atomic Energy Agency (IAEA). Ultimately, and totally unique from beam-type instruments, the move to the higher-resolution Orbitrap platform provides all of the benefits of high mass resolution, with no penalties in sensitivity, precision, or dynamic range for uranium analysis.
- Open Access
- 23 January 2019
- Published by Oxford University Press (OUP) in Metallomics
- Vol. 11 (1) , 166-175
Siderophore profiling of co-habitating soil bacteria by ultra-high resolution mass spectrometry
Calcareous soil microbes complete for scarce iron by synthesizing diverse suites of siderophores detectable by ultra-high resolution mass spectrometry.
- 23 January 2019
- Published by Oxford University Press (OUP) in Metallomics
- Vol. 11 (1) , 166-175
Open AccessSiderophore profiling of co-habitating soil bacteria by ultra-high resolution mass spectrometry
Calcareous soil microbes complete for scarce iron by synthesizing diverse suites of siderophores detectable by ultra-high resolution mass spectrometry.
- 23 January 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (2) , 251-259
Concomitant ion effects on isotope ratio measurements with liquid sampling – atmospheric pressure glow discharge ion source Orbitrap mass spectrometry
In an effort to understand and improve the accuracy and precision of the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap system, effects of concomitant ions on the acquired mass spectra are examined and presented. The LS-APGD/Orbitrap instrument system is capable of high quality isotope ratio measurements, which are of high analytical interest for nuclear non-proliferation detection applications. The presence of background and concomitant ions (water clusters, matrix, and other analytes) has presented limitations in earlier studies. In order to mitigate these effects, an alternative quadrupole-Orbitrap hybrid mass spectrometer was employed in this study. This instrument configuration has a quadrupole mass filter preceding the Orbitrap to filter-out undesired non-analyte ions. Results are presented for the analysis of U in the presence of Rb, Ag, Ba, and Pb as concomitants, each present at 0.5 μg mL−1 concentration. Progressive filtering of each concomitant ion shows steadily improved U isotope ratio performance. Ultimately, a 235U/238U ratio of 0.007133, with a relative error of −2.1% and a relative standard deviation of 0.087% was achieved using this system, along with improved calibration linearity and lowered limits of detection. This performance is surprisingly good for an ion trap type mass spectrometry instrument.
- 23 January 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (2) , 251-259
Concomitant ion effects on isotope ratio measurements with liquid sampling – atmospheric pressure glow discharge ion source Orbitrap mass spectrometry
In an effort to understand and improve the accuracy and precision of the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap system, effects of concomitant ions on the acquired mass spectra are examined and presented. The LS-APGD/Orbitrap instrument system is capable of high quality isotope ratio measurements, which are of high analytical interest for nuclear non-proliferation detection applications. The presence of background and concomitant ions (water clusters, matrix, and other analytes) has presented limitations in earlier studies. In order to mitigate these effects, an alternative quadrupole-Orbitrap hybrid mass spectrometer was employed in this study. This instrument configuration has a quadrupole mass filter preceding the Orbitrap to filter-out undesired non-analyte ions. Results are presented for the analysis of U in the presence of Rb, Ag, Ba, and Pb as concomitants, each present at 0.5 μg mL−1 concentration. Progressive filtering of each concomitant ion shows steadily improved U isotope ratio performance. Ultimately, a 235U/238U ratio of 0.007133, with a relative error of −2.1% and a relative standard deviation of 0.087% was achieved using this system, along with improved calibration linearity and lowered limits of detection. This performance is surprisingly good for an ion trap type mass spectrometry instrument.
- Open Access
- 1 January 2017
- Published by Oxford University Press (OUP) in Metallomics
- Vol. 9 (1) , 82-92
Unambiguous identification and discovery of bacterial siderophores by direct injection 21 Tesla Fourier transform ion cyclotron resonance mass spectrometry
Under iron-limiting conditions, bacteria produce low molecular mass Fe(iii) binding molecules known as siderophores to sequester the Fe(iii), along wi
- 1 January 2017
- Published by Oxford University Press (OUP) in Metallomics
- Vol. 9 (1) , 82-92
Open AccessUnambiguous identification and discovery of bacterial siderophores by direct injection 21 Tesla Fourier transform ion cyclotron resonance mass spectrometry
Under iron-limiting conditions, bacteria produce low molecular mass Fe(iii) binding molecules known as siderophores to sequester the Fe(iii), along wi
- Open Access
- 1 December 2011
- Published by Springer Nature in BMC Systems Biology
- Vol. 5 (1) , 1-16
Dynamic proteomic profiling of a unicellular cyanobacterium CyanotheceATCC51142 across light-dark diurnal cycles
Background: Unicellular cyanobacteria of the genus Cyanothece are recognized for their ability to execute nitrogen (N2)-fixation in the dark and photosynthesis in the light. An understanding of these mechanistic processes in an integrated systems context should provide insights into how Cyanothece might be optimized for specialized environments and/or industrial purposes. Systems-wide dynamic proteomic profiling with mass spectrometry (MS) analysis should reveal fundamental insights into the control and regulation of these functions. Results: To expand upon the current knowledge of protein expression patterns in Cyanothece ATCC51142, we performed quantitative proteomic analysis using partial ("unsaturated") metabolic labeling and high mass accuracy LC-MS analysis. This dynamic proteomic profiling identified 721 actively synthesized proteins with significant temporal changes in expression throughout the light-dark cycles, of which 425 proteins matched with previously characterized cycling transcripts. The remaining 296 proteins contained a cluster of proteins uniquely involved in DNA replication and repair, protein degradation, tRNA synthesis and modification, transport and binding, and regulatory functions. Functional classification of labeled proteins suggested that proteins involved in respiration and glycogen metabolism showed increased expression in the dark cycle together with nitrogenase, suggesting that N2-fixation is mediated by higher respiration and glycogen metabolism. Results indicated that Cyanothece ATCC51142 might utilize alternative pathways for carbon (C) and nitrogen (N) acquisition, particularly, aspartic acid and glutamate as substrates of C and N, respectively. Utilization of phosphoketolase (PHK) pathway for the conversion of xylulose-5P to pyruvate and acetyl-P likely constitutes an alternative strategy to compensate higher ATP and NADPH demand. Conclusion: This study provides a deeper systems level insight into how Cyanothece ATCC51142 modulates cellular functions to accommodate photosynthesis and N2-fixation within the single cell.
- 1 December 2011
- Published by Springer Nature in BMC Systems Biology
- Vol. 5 (1) , 1-16
Open AccessDynamic proteomic profiling of a unicellular cyanobacterium CyanotheceATCC51142 across light-dark diurnal cycles
Background: Unicellular cyanobacteria of the genus Cyanothece are recognized for their ability to execute nitrogen (N2)-fixation in the dark and photosynthesis in the light. An understanding of these mechanistic processes in an integrated systems context should provide insights into how Cyanothece might be optimized for specialized environments and/or industrial purposes. Systems-wide dynamic proteomic profiling with mass spectrometry (MS) analysis should reveal fundamental insights into the control and regulation of these functions. Results: To expand upon the current knowledge of protein expression patterns in Cyanothece ATCC51142, we performed quantitative proteomic analysis using partial ("unsaturated") metabolic labeling and high mass accuracy LC-MS analysis. This dynamic proteomic profiling identified 721 actively synthesized proteins with significant temporal changes in expression throughout the light-dark cycles, of which 425 proteins matched with previously characterized cycling transcripts. The remaining 296 proteins contained a cluster of proteins uniquely involved in DNA replication and repair, protein degradation, tRNA synthesis and modification, transport and binding, and regulatory functions. Functional classification of labeled proteins suggested that proteins involved in respiration and glycogen metabolism showed increased expression in the dark cycle together with nitrogenase, suggesting that N2-fixation is mediated by higher respiration and glycogen metabolism. Results indicated that Cyanothece ATCC51142 might utilize alternative pathways for carbon (C) and nitrogen (N) acquisition, particularly, aspartic acid and glutamate as substrates of C and N, respectively. Utilization of phosphoketolase (PHK) pathway for the conversion of xylulose-5P to pyruvate and acetyl-P likely constitutes an alternative strategy to compensate higher ATP and NADPH demand. Conclusion: This study provides a deeper systems level insight into how Cyanothece ATCC51142 modulates cellular functions to accommodate photosynthesis and N2-fixation within the single cell.