Kwang-Cheol Ko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kwang-Cheol Ko has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Se-Hoon Kim
Department of Electrical Engineering, Hanyang University, 222, Wangsimni-ro, Seongdong-gu, Seoul 04763, Korea
7 shared publications - Ji-Eun Baek
Hanyang Univ, Dept Elect Engn, Seoul 04763, South Korea
6 shared publications Young-Maan Cho
Hanyang University
5 shared publications- Jae-Ho Rhee
Department of Electrical Engineering, Hanyang University, Seoul, South Korea
4 shared publications Chang-Jin Lee
Department of Electrical Engineering, Hanyang University, Seoul, Korea
3 shared publicationsJi-Eun Baek
Hanyang University
3 shared publications
Latest Publications
- Open Access
- 28 March 2024
- Published by MDPI AG in Electronics
- Vol. 13 (7) , 1261
Optimal Design of Relay Coil Inductance to Improve Transmission Efficiency of Four-Coil Magnetic Resonance Wireless Power Transmission Systems
Magnetic resonance wireless power transmission consists of a source coil and relay coil (transmission coil (Tx-coil), receiving coil (Rx-coil)). The relay coil is designed with windings and a series capacitor, which are resonant with the input voltage frequency. Magnetic resonant wireless power transmission by a relay coil enables the transmission of power from a few centimeters to several meters. Recently, research has been conducted on the shape and material of each coil to increase the transmission distance. However, limitations remain with respect to increasing the transmission distance. Specifically, the optimization of the electrical characteristics of the relay coil is necessary to increase the transmission distance and improve efficiency. In this study, we configured the inductance of the relay coil to be approximately 95 μH, 270 μH, and 630 μH. Accordingly, we designed the series capacitors to have the same resonant frequency and analyzed the transmission characteristics of each relay coil. We confirmed that as the inductance increased, the transmission efficiency increased by up to 10%. The relay coil was designed to have an inductance of approximately three to six times that of the source coil (load coil). Thus, the optimal design of the relay coil is believed to be the most efficient and economical coil design.
- 28 March 2024
- Published by MDPI AG in Electronics
- Vol. 13 (7) , 1261
Open AccessOptimal Design of Relay Coil Inductance to Improve Transmission Efficiency of Four-Coil Magnetic Resonance Wireless Power Transmission Systems
Magnetic resonance wireless power transmission consists of a source coil and relay coil (transmission coil (Tx-coil), receiving coil (Rx-coil)). The relay coil is designed with windings and a series capacitor, which are resonant with the input voltage frequency. Magnetic resonant wireless power transmission by a relay coil enables the transmission of power from a few centimeters to several meters. Recently, research has been conducted on the shape and material of each coil to increase the transmission distance. However, limitations remain with respect to increasing the transmission distance. Specifically, the optimization of the electrical characteristics of the relay coil is necessary to increase the transmission distance and improve efficiency. In this study, we configured the inductance of the relay coil to be approximately 95 μH, 270 μH, and 630 μH. Accordingly, we designed the series capacitors to have the same resonant frequency and analyzed the transmission characteristics of each relay coil. We confirmed that as the inductance increased, the transmission efficiency increased by up to 10%. The relay coil was designed to have an inductance of approximately three to six times that of the source coil (load coil). Thus, the optimal design of the relay coil is believed to be the most efficient and economical coil design.
- Open Access
- 7 December 2023
- Published by MDPI AG in Electronics
- Vol. 12 (24) , 4921
Analysis and Design of a Pulsed Power Generator for a Low-Energy Magnetic Pulse Welding System
Magnetic pulse welding (MPW) is a joining method that uses Lorentz force generated from an electromagnetic field. This method not only has the advantage of not causing thermal deformation of the material and no by-products compared to the method of joining by melting by heat but also enables the joining of dissimilar metals rather than the joining of the same metal. Joining dissimilar metals can reduce the weight of mechanical devices and apply them to various fields. Recent research on MPW has focused on the characteristics of bonding according to the material or structure of metal rather than on pulse power research that generates the main factor of operation. However, in the operation of MPW, a Lorentz force is generated by the induced current caused by the electromotive force created in the flyer tube and the external magnetic field in the actuator. Therefore, it is necessary to analyze and optimize the pulse power to improve reliability and to miniaturize the system to expand the MPW utilization range. In this paper, we analyzed MPW operation according to a section of the pulse power output waveform. A condition for obtaining the maximum current in the flyer tube was proposed, and a plateau-shaped waveform was derived as an ideal output waveform capable of maintaining the Lorentz force. Through analysis, the proposed pulse power device is designed as a pulse-forming network (PFN) that generates a plateau output waveform. The design specification is that the circuit of PFN (type E) is designed so that the output waveform is pulse width 10 (μs) and the maximum output current is 100 (kA), and it is verified by simulation.
- 7 December 2023
- Published by MDPI AG in Electronics
- Vol. 12 (24) , 4921
Open AccessAnalysis and Design of a Pulsed Power Generator for a Low-Energy Magnetic Pulse Welding System
Magnetic pulse welding (MPW) is a joining method that uses Lorentz force generated from an electromagnetic field. This method not only has the advantage of not causing thermal deformation of the material and no by-products compared to the method of joining by melting by heat but also enables the joining of dissimilar metals rather than the joining of the same metal. Joining dissimilar metals can reduce the weight of mechanical devices and apply them to various fields. Recent research on MPW has focused on the characteristics of bonding according to the material or structure of metal rather than on pulse power research that generates the main factor of operation. However, in the operation of MPW, a Lorentz force is generated by the induced current caused by the electromotive force created in the flyer tube and the external magnetic field in the actuator. Therefore, it is necessary to analyze and optimize the pulse power to improve reliability and to miniaturize the system to expand the MPW utilization range. In this paper, we analyzed MPW operation according to a section of the pulse power output waveform. A condition for obtaining the maximum current in the flyer tube was proposed, and a plateau-shaped waveform was derived as an ideal output waveform capable of maintaining the Lorentz force. Through analysis, the proposed pulse power device is designed as a pulse-forming network (PFN) that generates a plateau output waveform. The design specification is that the circuit of PFN (type E) is designed so that the output waveform is pulse width 10 (μs) and the maximum output current is 100 (kA), and it is verified by simulation.
- Open Access
- 26 June 2022
- Published by MDPI AG in Electronics
- Vol. 11 (13) , 2002
Investigation of the Optimum Diameter of the Ring Reflector for an Axial Virtual Cathode Oscillator
The optimum hole diameter of a ring reflector was experimentally investigated using an axial virtual cathode oscillator (vircator) to enhance its microwave power. The ring reflector enhances the microwave power from the axial vircator by forming a cavity. The ring reflector was installed 9 mm behind the anode. The optimum hole diameter of the ring reflector was analyzed through simulations and experiments by changing the diameter from 60 mm to 160. PIC simulations show that the maximum peak microwave power was generated when the hole diameter was 116 mm and enhanced by 210%. The experiments show similar results to the simulations. The largest peak maximum power was 23.67 MW when the hole diameter was 120 mm. The simulations show that the dominant microwave frequency was formed between 5.33 GHz and 6.7 GHz. The experiments show that the dominant microwave frequency was formed between 5.3 GHz and 5.8 GHz. The frequency trend was approximately similar to that of the simulation results. However, the trend depending on the hole diameter was not as obvious as in the simulations. Although the frequency change was not as clear as in the simulations, experiments show that the hole diameter of the ring reflector affects the vircator operation.
- 26 June 2022
- Published by MDPI AG in Electronics
- Vol. 11 (13) , 2002
Open AccessInvestigation of the Optimum Diameter of the Ring Reflector for an Axial Virtual Cathode Oscillator
The optimum hole diameter of a ring reflector was experimentally investigated using an axial virtual cathode oscillator (vircator) to enhance its microwave power. The ring reflector enhances the microwave power from the axial vircator by forming a cavity. The ring reflector was installed 9 mm behind the anode. The optimum hole diameter of the ring reflector was analyzed through simulations and experiments by changing the diameter from 60 mm to 160. PIC simulations show that the maximum peak microwave power was generated when the hole diameter was 116 mm and enhanced by 210%. The experiments show similar results to the simulations. The largest peak maximum power was 23.67 MW when the hole diameter was 120 mm. The simulations show that the dominant microwave frequency was formed between 5.33 GHz and 6.7 GHz. The experiments show that the dominant microwave frequency was formed between 5.3 GHz and 5.8 GHz. The frequency trend was approximately similar to that of the simulation results. However, the trend depending on the hole diameter was not as obvious as in the simulations. Although the frequency change was not as clear as in the simulations, experiments show that the hole diameter of the ring reflector affects the vircator operation.
- Open Access
- 31 May 2022
- Published by Korean Institute of Electromagnetic Engineering and Science in Journal of Electromagnetic Engineering and Science
- Vol. 22 (3) , 265-271
Investigation of an Axial Virtual Cathode Oscillator with an Open-Ended Coaxial Cathode
A cathode with an open-ended coaxial structure is experimentally investigated using an axial virtual cathode oscillator (vircator). To enhance the microwave power output, an open-ended coaxial cathode is installed in the axial vircator. The proposed cathode is designed based on the reciprocating frequency of the vircator. The operation features of an axial vircator with a solid cathode, an annular cathode, and an open-ended coaxial cathode are comparatively analyzed through simulations and experiments. Three cathodes are machined using graphite. A stainless steel mesh with a transparency of 70% is used as an anode. The anode-to-cathode gap is fixed to 6 mm. The vircator is driven using a 10-stage PFN-Marx generator with a characteristic impedance of 31 Ω. The PFN-Marx generator applies -150 kV voltage pulses with a 170–200 ns pulse width into the vircator. The microwave power from the solid and annular cathodes is 11.22 MW and 11.27 MW, respectively. The proposed cathode generates a microwave with a power of 12.65 MW while enhancing the microwave power by 13% compared with the solid and annular cathodes. The proposed cathode shows a frequency shift to 3.4 GHz, which is a much lower frequency than that of the solid cathode at 6.34 GHz.
- 31 May 2022
- Published by Korean Institute of Electromagnetic Engineering and Science in Journal of Electromagnetic Engineering and Science
- Vol. 22 (3) , 265-271
Open AccessInvestigation of an Axial Virtual Cathode Oscillator with an Open-Ended Coaxial Cathode
A cathode with an open-ended coaxial structure is experimentally investigated using an axial virtual cathode oscillator (vircator). To enhance the microwave power output, an open-ended coaxial cathode is installed in the axial vircator. The proposed cathode is designed based on the reciprocating frequency of the vircator. The operation features of an axial vircator with a solid cathode, an annular cathode, and an open-ended coaxial cathode are comparatively analyzed through simulations and experiments. Three cathodes are machined using graphite. A stainless steel mesh with a transparency of 70% is used as an anode. The anode-to-cathode gap is fixed to 6 mm. The vircator is driven using a 10-stage PFN-Marx generator with a characteristic impedance of 31 Ω. The PFN-Marx generator applies -150 kV voltage pulses with a 170–200 ns pulse width into the vircator. The microwave power from the solid and annular cathodes is 11.22 MW and 11.27 MW, respectively. The proposed cathode generates a microwave with a power of 12.65 MW while enhancing the microwave power by 13% compared with the solid and annular cathodes. The proposed cathode shows a frequency shift to 3.4 GHz, which is a much lower frequency than that of the solid cathode at 6.34 GHz.
- Open Access
- 28 December 2021
- Published by MDPI AG in Electronics
- Vol. 11 (1) , 82
Operation Features of a Coaxial Virtual Cathode Oscillator Emitting Electrons in the Outer Radial Direction
The operation features of the coaxial virtual cathode oscillator emitting electrons in the outer radial direction were investigated through simulations and experiments. A coaxial vircator was compared with an axial vircator when the anode to cathode distance of both vircators was 6 mm. The proposed coaxial vircator was operated when the anode to cathode distance was 5 mm, 6 mm, and 7 mm. The peak power and frequency of the microwave generated from the proposed coaxial vircator when the anode to cathode distance was 6 mm were 20.18 MW and 6.17 GHz, respectively. The simulations and experiments show that the proposed coaxial vircator generates 80% more microwave power than the axial vircator with the same anode to cathode distance. According to the simulations and experiments, the proposed coaxial vircator tends to generate a higher power average when the anode to cathode distance was larger than 5 mm. The frequency of the proposed coaxial vircator when the anode to cathode distance was 5 mm and 7 mm was approximately 8 GHz and 5 GHz, respectively. The geometric factor of the proposed coaxial vircator was considered to be the reason for the greater microwave power generation than the axial vircator. The frequency of the proposed coaxial vircator decreases inversely proportional with the anode to cathode distance as observed in the axial and basic coaxial vircators.
- 28 December 2021
- Published by MDPI AG in Electronics
- Vol. 11 (1) , 82
Open AccessOperation Features of a Coaxial Virtual Cathode Oscillator Emitting Electrons in the Outer Radial Direction
The operation features of the coaxial virtual cathode oscillator emitting electrons in the outer radial direction were investigated through simulations and experiments. A coaxial vircator was compared with an axial vircator when the anode to cathode distance of both vircators was 6 mm. The proposed coaxial vircator was operated when the anode to cathode distance was 5 mm, 6 mm, and 7 mm. The peak power and frequency of the microwave generated from the proposed coaxial vircator when the anode to cathode distance was 6 mm were 20.18 MW and 6.17 GHz, respectively. The simulations and experiments show that the proposed coaxial vircator generates 80% more microwave power than the axial vircator with the same anode to cathode distance. According to the simulations and experiments, the proposed coaxial vircator tends to generate a higher power average when the anode to cathode distance was larger than 5 mm. The frequency of the proposed coaxial vircator when the anode to cathode distance was 5 mm and 7 mm was approximately 8 GHz and 5 GHz, respectively. The geometric factor of the proposed coaxial vircator was considered to be the reason for the greater microwave power generation than the axial vircator. The frequency of the proposed coaxial vircator decreases inversely proportional with the anode to cathode distance as observed in the axial and basic coaxial vircators.
- Open Access
- 30 September 2021
- Published by Korean Institute of Electromagnetic Engineering and Science in Journal of Electromagnetic Engineering and Science
- Vol. 21 (4) , 329-335
Transmission Distance Improvement of a Two-Coil Magnetic Resonance Wireless Power Transmission System Using Transformers
In this paper, a two-coil magnetic resonance wireless transmission system is studied to improve the transmission distance using transformers. A conventional two-coil and four-coil wireless power transmission (WPT) system as well as a two-coil WPT system with transformers are analyzed comparatively via circuit simulations and experiments. Circuit analysis was used to predict the transmission distance with the highest efficiency. To verify the improvement in the transmission distance of the proposed system, transformers with inductance values of 80, 100, and 140 μH were fabricated and analyzed through experiments and simulations. A maximum S21 parameter of 0.76 was noted when the inductance was 80 μH and the transmitting distance was 4 cm. The experimental results almost matched the simulation results. From the experiments, it was shown that the transmitting distance of a WPT system can be adjusted by using transformers. Additionally, it was found that the transmitting distance is inversely proportional to the transformer inductance, and the efficiency of the WPT system decreases with the transmitting distance.
- 30 September 2021
- Published by Korean Institute of Electromagnetic Engineering and Science in Journal of Electromagnetic Engineering and Science
- Vol. 21 (4) , 329-335
Open AccessTransmission Distance Improvement of a Two-Coil Magnetic Resonance Wireless Power Transmission System Using Transformers
In this paper, a two-coil magnetic resonance wireless transmission system is studied to improve the transmission distance using transformers. A conventional two-coil and four-coil wireless power transmission (WPT) system as well as a two-coil WPT system with transformers are analyzed comparatively via circuit simulations and experiments. Circuit analysis was used to predict the transmission distance with the highest efficiency. To verify the improvement in the transmission distance of the proposed system, transformers with inductance values of 80, 100, and 140 μH were fabricated and analyzed through experiments and simulations. A maximum S21 parameter of 0.76 was noted when the inductance was 80 μH and the transmitting distance was 4 cm. The experimental results almost matched the simulation results. From the experiments, it was shown that the transmitting distance of a WPT system can be adjusted by using transformers. Additionally, it was found that the transmitting distance is inversely proportional to the transformer inductance, and the efficiency of the WPT system decreases with the transmitting distance.
- Open Access
- 5 August 2021
- Published by MDPI AG in Electronics
- Vol. 10 (16) , 1878
Experimental Investigation into the Optimum Position of a Ring Reflector for an Axial Virtual Cathode Oscillator
A ring reflector was experimentally investigated using an axial virtual cathode oscillator (vircator). The ring reflector was installed behind the mesh anode of the axial vircator to enhance the microwave power output by forming a resonant cavity and increasing the electron beam to microwave energy conversion efficiency. The optimum position of the ring reflector is analyzed through simulations and experiments by varying the anode to reflector distance from 6 mm to 24 mm in 3 mm steps. PIC simulations show that the ring reflector enhances the microwave power of the axial vircator up to 220%. Experiments show that the microwave power from the axial vircator without the ring reflector is 11.22 MW. The maximum average peak microwave power of the axial vircator with the ring reflector is 25.82 MW when the anode to ring reflector distance is 18 mm. From the simulations and experiments, it can be seen that the ring reflector yields decaying enhancement that is inversely proportional to the anode to ring reflector distance and there is no noticeable microwave enhancement after 24 mm. The frequency range attained from the simulations and experiments is 5.8 to 6.7 GHz and 5.16 to 5.8 GHz, respectively. The difference between the simulation and experimental results is due to the error in the anode to cathode gap distance. Although the frequency is slightly changed, the ring reflector seems to have no influence on the frequency of the generated microwave.
- 5 August 2021
- Published by MDPI AG in Electronics
- Vol. 10 (16) , 1878
Open AccessExperimental Investigation into the Optimum Position of a Ring Reflector for an Axial Virtual Cathode Oscillator
A ring reflector was experimentally investigated using an axial virtual cathode oscillator (vircator). The ring reflector was installed behind the mesh anode of the axial vircator to enhance the microwave power output by forming a resonant cavity and increasing the electron beam to microwave energy conversion efficiency. The optimum position of the ring reflector is analyzed through simulations and experiments by varying the anode to reflector distance from 6 mm to 24 mm in 3 mm steps. PIC simulations show that the ring reflector enhances the microwave power of the axial vircator up to 220%. Experiments show that the microwave power from the axial vircator without the ring reflector is 11.22 MW. The maximum average peak microwave power of the axial vircator with the ring reflector is 25.82 MW when the anode to ring reflector distance is 18 mm. From the simulations and experiments, it can be seen that the ring reflector yields decaying enhancement that is inversely proportional to the anode to ring reflector distance and there is no noticeable microwave enhancement after 24 mm. The frequency range attained from the simulations and experiments is 5.8 to 6.7 GHz and 5.16 to 5.8 GHz, respectively. The difference between the simulation and experimental results is due to the error in the anode to cathode gap distance. Although the frequency is slightly changed, the ring reflector seems to have no influence on the frequency of the generated microwave.
- 9 January 2020
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 15 (2) , 757-763
Experimental Investigation of Improvement in the Dielectric Recovery Characteristics of a Molded Case Circuit Breaker Splitter Plate
- 9 January 2020
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 15 (2) , 757-763
Experimental Investigation of Improvement in the Dielectric Recovery Characteristics of a Molded Case Circuit Breaker Splitter Plate
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Experimental Study on Axial Virtual Cathode Oscillator Operated Using 140J/170kV Pulsed Source
An axial virtual cathode oscillator with stainless steel cathode and stainless steel anode is experimentally analyzed. A 140J/170kV Marx generator is used as an impulse generator to drive the axial virtual cathode oscillator. The gap distance between the anode and the cathode sets to 0.4 cm. The output power of the axial virtual cathode oscillator is analyzed for stainless steel cathode.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Experimental Study on Axial Virtual Cathode Oscillator Operated Using 140J/170kV Pulsed Source
An axial virtual cathode oscillator with stainless steel cathode and stainless steel anode is experimentally analyzed. A 140J/170kV Marx generator is used as an impulse generator to drive the axial virtual cathode oscillator. The gap distance between the anode and the cathode sets to 0.4 cm. The output power of the axial virtual cathode oscillator is analyzed for stainless steel cathode.
- 18 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (1) , 542-548
Hybrid Analog and Digital Control of a High Current Converter Based on an EDLC Bank for Rapidly Decreasing Input Voltage
- 18 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (1) , 542-548
Hybrid Analog and Digital Control of a High Current Converter Based on an EDLC Bank for Rapidly Decreasing Input Voltage