Todor I. Todorov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Todor I. Todorov has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Jake A. Carter
Department of Chemistry, Wake Forest University, Salem Hall, Box 7486, Winston-Salem, NC, 27109, USA
2 shared publications - Patrick J. Gray
Human Foods Program, Office of Laboratory Operations & Applied Science, US Food & Drug Administration, College Park, USA
2 shared publications - Abby G. Ershow
Office of Dietary Supplements, National Institutes of Health, Bethesda, MD 20892, USA
1 shared publication Amir Abdalla
US Food and Drug Administration
1 shared publication- Bryan T. Vinyard
Statistics and Bioinformatics Group, Agricultural Research Service, U.S. Department of Agriculture, Northeast Area, Beltsville, MD 20705, USA
1 shared publication - Cecile S. Rose
University of Colorado National Jewish Health Denver, CO
1 shared publication
Latest Publications
- Open Access
Large Iodine Variability in Retail Cows’ Milk in the U.S.: A Follow-Up Study among Different Retail Outlets
In a previous study, large variability in iodine content was found among samples of store brand retail milk at a single time point in a sampling taken from 24 nationwide U.S. locations for the USDA FoodData Central database, but the sampling plan was not designed to detect differences among locations. This follow-up study was carried out to evaluate iodine levels in retail milk across the U.S. over time. Milk samples (2% fat) were collected bimonthly in fourteen locations for one year and analyzed in duplicate. Control materials were used to support accuracy of results and ensure precision across analytical batches. The overall mean and standard error (SE) for iodine concentration were 82.5 (7.0) µg/240 mL serving, which was comparable to the previous national mean [85.0 (5.5) µg/240 mL]. A similar wide range among individual samples was detected (27.9–282 µg/240 mL). For some locations, the mean iodine concentration differed significantly from others, and differed from the national average by amounts ranging from −47 µg to +37 µg per serving. The between-sample range within location was large for some (up to 229 µg/serving) and minimal for others (as little as 13.2 µg/serving). These findings suggest iodine intake from some retail milk supplies could be over- or underestimated relative to the national average, even if the national average is suitable for population-wide intake estimates.
Open AccessLarge Iodine Variability in Retail Cows’ Milk in the U.S.: A Follow-Up Study among Different Retail Outlets
In a previous study, large variability in iodine content was found among samples of store brand retail milk at a single time point in a sampling taken from 24 nationwide U.S. locations for the USDA FoodData Central database, but the sampling plan was not designed to detect differences among locations. This follow-up study was carried out to evaluate iodine levels in retail milk across the U.S. over time. Milk samples (2% fat) were collected bimonthly in fourteen locations for one year and analyzed in duplicate. Control materials were used to support accuracy of results and ensure precision across analytical batches. The overall mean and standard error (SE) for iodine concentration were 82.5 (7.0) µg/240 mL serving, which was comparable to the previous national mean [85.0 (5.5) µg/240 mL]. A similar wide range among individual samples was detected (27.9–282 µg/240 mL). For some locations, the mean iodine concentration differed significantly from others, and differed from the national average by amounts ranging from −47 µg to +37 µg per serving. The between-sample range within location was large for some (up to 229 µg/serving) and minimal for others (as little as 13.2 µg/serving). These findings suggest iodine intake from some retail milk supplies could be over- or underestimated relative to the national average, even if the national average is suitable for population-wide intake estimates.
- 13 February 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (4) , 818-826
Exploring the working range of automated standard dilution analysis of nutrient elements in foods by inductively coupled plasma optical emission spectrometry
Inductively coupled plasma optical emission spectrometry (ICP-OES) is an important tool for measuring nutrient elements in food. ICP-OES methods typically determine analytical concentrations using external standard calibration but can be susceptible to matrix effects. The method of standard additions does not suffer from matrix effects but is time consuming and labor intensive. Automated standard dilution analysis (SDA) allows for online matrix matched calibration without preparing individual standard additions for each sample matrix. This approach may solve both time and matrix issues and has been described in the literature as an attractive alternative to standard additions. The working range of the method for nutrient elements, however, is an understudied feature of SDA that may be a potential drawback to routine analysis of foods. We evaluated automated SDA performance through the analysis of 10 reference materials and four fortified (i.e., spiked) foods spanning the AOAC food triangle. We evaluated the working range, accuracy, and precision for analyses of nutrient elements in foods. Accepted accuracy (80–120% recovery) was achieved for 10 nutrient elements, Ca, Cu, Fe, K, Mg, Mn, Na, P, S, and Zn, when the analytical solution concentration to standard concentration ratio was less than 10. This equates to a working range for each element spanning at least two orders of magnitude. Removing outliers, Z scores (n = 95) ranged from −1.8 to 0.88, and the average recovery (n = 85) from fortification experiments was 97 ± 12% (2σ). Therefore, automated SDA applied to ICP-OES may be used for nutrient elemental analyses in samples with difficult matrices such as foods.
- 13 February 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (4) , 818-826
Exploring the working range of automated standard dilution analysis of nutrient elements in foods by inductively coupled plasma optical emission spectrometry
Inductively coupled plasma optical emission spectrometry (ICP-OES) is an important tool for measuring nutrient elements in food. ICP-OES methods typically determine analytical concentrations using external standard calibration but can be susceptible to matrix effects. The method of standard additions does not suffer from matrix effects but is time consuming and labor intensive. Automated standard dilution analysis (SDA) allows for online matrix matched calibration without preparing individual standard additions for each sample matrix. This approach may solve both time and matrix issues and has been described in the literature as an attractive alternative to standard additions. The working range of the method for nutrient elements, however, is an understudied feature of SDA that may be a potential drawback to routine analysis of foods. We evaluated automated SDA performance through the analysis of 10 reference materials and four fortified (i.e., spiked) foods spanning the AOAC food triangle. We evaluated the working range, accuracy, and precision for analyses of nutrient elements in foods. Accepted accuracy (80–120% recovery) was achieved for 10 nutrient elements, Ca, Cu, Fe, K, Mg, Mn, Na, P, S, and Zn, when the analytical solution concentration to standard concentration ratio was less than 10. This equates to a working range for each element spanning at least two orders of magnitude. Removing outliers, Z scores (n = 95) ranged from −1.8 to 0.88, and the average recovery (n = 85) from fortification experiments was 97 ± 12% (2σ). Therefore, automated SDA applied to ICP-OES may be used for nutrient elemental analyses in samples with difficult matrices such as foods.
- 7 July 2022
- Published by Springer Nature in Food Analytical Methods
- Vol. 15 (11) , 3079-3091
Method Development for the Quantitative Analysis of Multivitamin Supplements by Laser Ablation–Inductively Coupled Plasma–Mass Spectrometry (LA-ICP-MS)
- 7 July 2022
- Published by Springer Nature in Food Analytical Methods
- Vol. 15 (11) , 3079-3091
Method Development for the Quantitative Analysis of Multivitamin Supplements by Laser Ablation–Inductively Coupled Plasma–Mass Spectrometry (LA-ICP-MS)
- 19 January 2022
- Published by Elsevier in Chemosphere
- Vol. 294, 133651
Distribution of 26 major and trace elements in edible seaweeds from the US market
- 19 January 2022
- Published by Elsevier in Chemosphere
- Vol. 294, 133651
Distribution of 26 major and trace elements in edible seaweeds from the US market
- Open Access
- 24 April 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (9) , 4526
A Case of Silicone and Sarcoid Granulomas in a Patient with “Highly Cohesive” Silicone Breast Implants: A Histopathologic and Laser Raman Microprobe Analysis
Foreign body giant cell (FBGC) reaction to silicone material in the lymph nodes of patients with silicone breast implants has been documented in the literature, with a number of case reports dating back to 1978. Many of these case reports describe histologic features of silicone lymphadenopathy in regional lymph nodes from patients with multiple sets of different types of implants, including single lumen smooth surface gel, single lumen textured surface gel, single lumen with polyethylene terephthalate patch, single lumen with polyurethane coating, and double lumen smooth surface. Only one other case report described a patient with highly-cohesive breast implants and silicone granulomas of the skin. In this article, we describe a patient with a clinical presentation of systemic sarcoidosis following highly cohesive breast implant placement. Histopathologic analysis and Confocal Laser Raman Microprobe (CLRM) examination were used to confirm the presence of silicone in the axillary lymph node and capsular tissues. This is the first report where chemical spectroscopic mapping has been used to establish and identify the coexistence of Schaumann bodies, consisting of calcium oxalate and calcium phosphate minerals, together with silicone implant material.
- 24 April 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (9) , 4526
Open AccessA Case of Silicone and Sarcoid Granulomas in a Patient with “Highly Cohesive” Silicone Breast Implants: A Histopathologic and Laser Raman Microprobe Analysis
Foreign body giant cell (FBGC) reaction to silicone material in the lymph nodes of patients with silicone breast implants has been documented in the literature, with a number of case reports dating back to 1978. Many of these case reports describe histologic features of silicone lymphadenopathy in regional lymph nodes from patients with multiple sets of different types of implants, including single lumen smooth surface gel, single lumen textured surface gel, single lumen with polyethylene terephthalate patch, single lumen with polyurethane coating, and double lumen smooth surface. Only one other case report described a patient with highly-cohesive breast implants and silicone granulomas of the skin. In this article, we describe a patient with a clinical presentation of systemic sarcoidosis following highly cohesive breast implant placement. Histopathologic analysis and Confocal Laser Raman Microprobe (CLRM) examination were used to confirm the presence of silicone in the axillary lymph node and capsular tissues. This is the first report where chemical spectroscopic mapping has been used to establish and identify the coexistence of Schaumann bodies, consisting of calcium oxalate and calcium phosphate minerals, together with silicone implant material.
- 1 August 2019
- Published by Elsevier in Food Chemistry
- Vol. 289, 299-307
Distribution of nutrient and toxic elements in brown and polished rice
- 1 August 2019
- Published by Elsevier in Food Chemistry
- Vol. 289, 299-307
Distribution of nutrient and toxic elements in brown and polished rice
- 8 June 2018
- Published by Springer Nature in Food Analytical Methods
- Vol. 11 (11) , 3211-3223
Comparison of ICP-MS and Spectrophotometry Methods for the Analysis of Iodine in 2013 US FDA Total Diet Study Samples
- 8 June 2018
- Published by Springer Nature in Food Analytical Methods
- Vol. 11 (11) , 3211-3223
Comparison of ICP-MS and Spectrophotometry Methods for the Analysis of Iodine in 2013 US FDA Total Diet Study Samples
- Open Access
- 23 April 2018
- Published by Taylor & Francis in Toxicology Mechanisms and Methods
- Vol. 28 (7) , 475-487
Method to characterize inorganic particulates in lung tissue biopsies using field emission scanning electron microscopy
Humans accumulate large numbers of inorganic particles in their lungs over a lifetime. Whether this causes or contributes to debilitating disease over a normal lifespan depends on the type and concentration of the particles. We developed and tested a protocol for in situ characterization of the types and distribution of inorganic particles in biopsied lung tissue from three human groups using field emission scanning electron microscopy (FE-SEM) combined with energy dispersive spectroscopy (EDS). Many distinct particle types were recognized among the 13 000 particles analyzed. Silica, feldspars, clays, titanium dioxides, iron oxides and phosphates were the most common constituents in all samples. Particles were classified into three general groups: endogenous, which form naturally in the body; exogenic particles, natural earth materials; and anthropogenic particles, attributed to industrial sources. These in situ results were compared with those using conventional sodium hypochlorite tissue digestion and particle filtration. With the exception of clays and phosphates, the relative abundances of most common particle types were similar in both approaches. Nonetheless, the digestion/filtration method was determined to alter the texture and relative abundances of some particle types. SEM/EDS analysis of digestion filters could be automated in contrast to the more time intensive in situ analyses.
- 23 April 2018
- Published by Taylor & Francis in Toxicology Mechanisms and Methods
- Vol. 28 (7) , 475-487
Open AccessMethod to characterize inorganic particulates in lung tissue biopsies using field emission scanning electron microscopy
Humans accumulate large numbers of inorganic particles in their lungs over a lifetime. Whether this causes or contributes to debilitating disease over a normal lifespan depends on the type and concentration of the particles. We developed and tested a protocol for in situ characterization of the types and distribution of inorganic particles in biopsied lung tissue from three human groups using field emission scanning electron microscopy (FE-SEM) combined with energy dispersive spectroscopy (EDS). Many distinct particle types were recognized among the 13 000 particles analyzed. Silica, feldspars, clays, titanium dioxides, iron oxides and phosphates were the most common constituents in all samples. Particles were classified into three general groups: endogenous, which form naturally in the body; exogenic particles, natural earth materials; and anthropogenic particles, attributed to industrial sources. These in situ results were compared with those using conventional sodium hypochlorite tissue digestion and particle filtration. With the exception of clays and phosphates, the relative abundances of most common particle types were similar in both approaches. Nonetheless, the digestion/filtration method was determined to alter the texture and relative abundances of some particle types. SEM/EDS analysis of digestion filters could be automated in contrast to the more time intensive in situ analyses.
- 11 January 2016
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 33 (2) , 1-9
Analysis of iodine in food samples by inductively coupled plasma-mass spectrometry
This work shows a method for the determination of iodine in a variety of food samples and reference materials using inductively coupled plasma-mass spectrometry (ICP-MS) following alkaline extraction. Optimisation of the addition of organic carbon showed that a minimum of 3% 2-propanol was necessary for a constant ratio of iodine to internal standard. The limit of quantification (LOQ), calculated as 30σ for the method, was 36 ng g–1 in solid food samples. For method validation, seven standard reference materials (SRM) and 21 fortified food samples were used. The precision (%RSD) of the measurements was in the 2–7% range. Accuracies for the SRMs were 85–105%, while the fortified food samples showed 81–119% recoveries, including a number of samples fortified at 50% of the LOQ. Graphical Abstract
- 11 January 2016
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 33 (2) , 1-9
Analysis of iodine in food samples by inductively coupled plasma-mass spectrometry
This work shows a method for the determination of iodine in a variety of food samples and reference materials using inductively coupled plasma-mass spectrometry (ICP-MS) following alkaline extraction. Optimisation of the addition of organic carbon showed that a minimum of 3% 2-propanol was necessary for a constant ratio of iodine to internal standard. The limit of quantification (LOQ), calculated as 30σ for the method, was 36 ng g–1 in solid food samples. For method validation, seven standard reference materials (SRM) and 21 fortified food samples were used. The precision (%RSD) of the measurements was in the 2–7% range. Accuracies for the SRMs were 85–105%, while the fortified food samples showed 81–119% recoveries, including a number of samples fortified at 50% of the LOQ. Graphical Abstract
- 20 March 2003
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (8) , 1837-1843
Effect of Urea on the Polymer Buffer Solutions Used for the Electrophoretic Separations of Nucleic Acids
The present study describes the effect of urea on the properties of hydroxyethyl cellulose (HEC) polymer solutions used for the separation of nucleic acids. Solution properties were investigated by viscosity measurements and supplemented by Raman spectroscopy of the solution components. By using viscosimetry, it was possible to identify that borate, urea, and HEC participate in an interaction causing an increase in the viscosity of dilute solutions. In addition, short polymer chains exhibited a 4-fold decrease in the entanglement threshold in the presence of 4 M urea and 0.356 M total borate concentration. These interactions were found to be specific to HEC. Raman spectroscopy monitored serial addition of 8 M urea to HEC sieving solutions combined with factor analysis indicated formation of minor urea species. Lack of change in the Raman spectrum and relative amount of borate suggested that there is no direct interaction between borate and urea. These effects on HEC sieving solution properties lead to the use of low HEC concentrations that are beneficial for the separation of nucleic acids under denaturing conditions.
- 20 March 2003
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (8) , 1837-1843
Effect of Urea on the Polymer Buffer Solutions Used for the Electrophoretic Separations of Nucleic Acids
The present study describes the effect of urea on the properties of hydroxyethyl cellulose (HEC) polymer solutions used for the separation of nucleic acids. Solution properties were investigated by viscosity measurements and supplemented by Raman spectroscopy of the solution components. By using viscosimetry, it was possible to identify that borate, urea, and HEC participate in an interaction causing an increase in the viscosity of dilute solutions. In addition, short polymer chains exhibited a 4-fold decrease in the entanglement threshold in the presence of 4 M urea and 0.356 M total borate concentration. These interactions were found to be specific to HEC. Raman spectroscopy monitored serial addition of 8 M urea to HEC sieving solutions combined with factor analysis indicated formation of minor urea species. Lack of change in the Raman spectrum and relative amount of borate suggested that there is no direct interaction between borate and urea. These effects on HEC sieving solution properties lead to the use of low HEC concentrations that are beneficial for the separation of nucleic acids under denaturing conditions.