Yong-Sang Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yong-Sang Lee has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Keun-Woo Lee
Department of Prosthodontics, Veterans Health Service Medical Center, Seoul, Republic of Korea
17 shared publications - Sung-Yong Kim
Department of Prosthodontics, Veterans Health Service Medical Center, Seoul, Republic of Korea
15 shared publications - Seong-A Kim
Department of Prosthodontics, Veterans Health Service Medical Center, Seoul, Republic of Korea
12 shared publications - Joo-Hyuk Bang
Department of Prosthodontics, Veterans Health Service Medical Center, Seoul, Republic of Korea
10 shared publications - Hee-Won Jang
Department of Prosthodontics, Veterans Health Service Medical Center, Seoul, Republic of Korea
9 shared publications - Sun-Young Yim
Department of Prosthodontics, Veterans Health Service Medical Center, Seoul, Republic of Korea
7 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 64 (4) , 413-422
Implant-assisted removable partial denture rehabilitation in a partially edentulous patient with unilateral few remaining teeth: a case report
마예진, et al. J Korean Acad Prosthodont. 2026 Oct;64(4):413-422. https://doi.org/10.4047/jkap.2026.64.4.413
- 1 January 2026
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 64 (4) , 413-422
Open AccessImplant-assisted removable partial denture rehabilitation in a partially edentulous patient with unilateral few remaining teeth: a case report
마예진, et al. J Korean Acad Prosthodont. 2026 Oct;64(4):413-422. https://doi.org/10.4047/jkap.2026.64.4.413
- Open Access
- 1 January 2026
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 64 (2)
Esthetic rehabilitation of an anterior maxillary tooth using immediate implant placement and provisional restoration: a case report
- 1 January 2026
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 64 (2)
Open AccessEsthetic rehabilitation of an anterior maxillary tooth using immediate implant placement and provisional restoration: a case report
- Open Access
- 1 January 2026
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 64 (1)
Implant-assisted removable partial denture restoration in a patient with mandibular single tooth: a case report
- 1 January 2026
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 64 (1)
Open AccessImplant-assisted removable partial denture restoration in a patient with mandibular single tooth: a case report
- Open Access
- 31 August 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (17) , 9595
Survival and Complication Rates of Narrow-Diameter Implants Used for Immediate Provisional Restoration of the Mandibular Anterior Region: A Retrospective Study
Implant placement in the mandibular anterior region is often limited by narrow alveolar ridge width, particularly in older or medically compromised patients, where bone grafting is contraindicated or undesirable. This area is also crucial for esthetics, necessitating immediate restoration after tooth loss. This retrospective study evaluates the short- and long-term survival and complication rates of narrow-diameter implants (NDIs) placed for immediate provisional restoration in the mandibular anterior region. This study includes 22 one-piece NDIs (Osstem, Korea) placed in 13 patients with narrow ridges, immediately restored with non-functional provisional prostheses. Clinical records and follow-up data throughout 2023 were reviewed. Marginal bone loss (MBL) was assessed using standardized periapical radiographs. A generalized linear mixed model was used to analyze the correlation between MBL and clinical variables. The implant survival rate was 100% (95% CI: 82.7–100) over an average follow-up period of 7 years. Biological and mechanical complication rates were 18.18% and 4.54%, respectively; patient-based complications occurred in 30.77% of cases. No statistically significant predictors of MBL were identified, although smoking showed a trend toward significance (p = 0.096; OR = 8.00; 95% CI: 0.69–92.70). NDIs may be a viable option for immediate provisional restoration in this region, although findings should be interpreted cautiously.
- 31 August 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (17) , 9595
Open AccessSurvival and Complication Rates of Narrow-Diameter Implants Used for Immediate Provisional Restoration of the Mandibular Anterior Region: A Retrospective Study
Implant placement in the mandibular anterior region is often limited by narrow alveolar ridge width, particularly in older or medically compromised patients, where bone grafting is contraindicated or undesirable. This area is also crucial for esthetics, necessitating immediate restoration after tooth loss. This retrospective study evaluates the short- and long-term survival and complication rates of narrow-diameter implants (NDIs) placed for immediate provisional restoration in the mandibular anterior region. This study includes 22 one-piece NDIs (Osstem, Korea) placed in 13 patients with narrow ridges, immediately restored with non-functional provisional prostheses. Clinical records and follow-up data throughout 2023 were reviewed. Marginal bone loss (MBL) was assessed using standardized periapical radiographs. A generalized linear mixed model was used to analyze the correlation between MBL and clinical variables. The implant survival rate was 100% (95% CI: 82.7–100) over an average follow-up period of 7 years. Biological and mechanical complication rates were 18.18% and 4.54%, respectively; patient-based complications occurred in 30.77% of cases. No statistically significant predictors of MBL were identified, although smoking showed a trend toward significance (p = 0.096; OR = 8.00; 95% CI: 0.69–92.70). NDIs may be a viable option for immediate provisional restoration in this region, although findings should be interpreted cautiously.
- Open Access
- 1 January 2025
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 63 (2) , 194-202
Complete mouth rehabilitation with fixed implant-supported prosthesis in an edentulous maxilla using dental CAD-CAM technology
홍정은, et al. J Korean Acad Prosthodont. 2025 Apr;63(2):194-202. https://doi.org/10.4047/jkap.2025.63.2.194
- 1 January 2025
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 63 (2) , 194-202
Open AccessComplete mouth rehabilitation with fixed implant-supported prosthesis in an edentulous maxilla using dental CAD-CAM technology
홍정은, et al. J Korean Acad Prosthodont. 2025 Apr;63(2):194-202. https://doi.org/10.4047/jkap.2025.63.2.194
- Open Access
- 1 January 2025
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 63 (2) , 176-185
Prosthodontic treatment with implant-assisted partial denture for limited abutment teeth and bone loss: case report
이향은, et al. J Korean Acad Prosthodont. 2025 Apr;63(2):176-185. https://doi.org/10.4047/jkap.2025.63.2.176
- 1 January 2025
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 63 (2) , 176-185
Open AccessProsthodontic treatment with implant-assisted partial denture for limited abutment teeth and bone loss: case report
이향은, et al. J Korean Acad Prosthodont. 2025 Apr;63(2):176-185. https://doi.org/10.4047/jkap.2025.63.2.176
- Open Access
- 20 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (18) , 8504
Four Different Build Angles in 3D-Printed Complete Denture Bases: A Comparative In Vitro Study
In this study, we aimed to investigate the differences in tissue surface adaptation and the variations in distances between reference points on the polished surfaces of 3D-printed denture bases produced at different build angles. The build angles were 0°, 30°, 60°, and 90°, with 15 denture bases printed for each angle. Using the Geomagic Control® software, a 3D best-fit alignment was conducted between the denture base tissue surface and the reference shape of the edentulous maxilla model to calculate the root mean square error. The distances between reference points on the polished surface were measured using digital calipers. A one-way analysis of variance was conducted for statistical analysis. The adaptation, as measured by the root mean square error, varied significantly among denture bases with different build angles. The distances between the anterior and posterior reference points of the polished surface were also significantly different. However, within the limitations of this study, the variations in adaptations and dimensional accuracy across different build angles were within clinically acceptable ranges. In clinical practice, the print angle can be adjusted based on factors such as printing time, resin consumption, and the number of denture bases being printed simultaneously.
- 20 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (18) , 8504
Open AccessFour Different Build Angles in 3D-Printed Complete Denture Bases: A Comparative In Vitro Study
In this study, we aimed to investigate the differences in tissue surface adaptation and the variations in distances between reference points on the polished surfaces of 3D-printed denture bases produced at different build angles. The build angles were 0°, 30°, 60°, and 90°, with 15 denture bases printed for each angle. Using the Geomagic Control® software, a 3D best-fit alignment was conducted between the denture base tissue surface and the reference shape of the edentulous maxilla model to calculate the root mean square error. The distances between reference points on the polished surface were measured using digital calipers. A one-way analysis of variance was conducted for statistical analysis. The adaptation, as measured by the root mean square error, varied significantly among denture bases with different build angles. The distances between the anterior and posterior reference points of the polished surface were also significantly different. However, within the limitations of this study, the variations in adaptations and dimensional accuracy across different build angles were within clinically acceptable ranges. In clinical practice, the print angle can be adjusted based on factors such as printing time, resin consumption, and the number of denture bases being printed simultaneously.
- Open Access
- 30 August 2024
- Published by MDPI AG in Preprints.org
Four Different Build Angles in 3D-Printed Complete Denture Bases: A Comparative In Vitro Study
In this study, we aimed to investigate the differences in tissue surface adaptation and the variations in distances between reference points on the polished surfaces of 3D-printed denture bases with different build angles. The build angles were 0°, 30°, 60°, and 90°, with 15 denture bases printed for each angle. Using the Geomagic Control® software, a 3D best-fit alignment was conducted between the denture base tissue surface and the reference shape of the edentulous maxilla model to calculate the root mean square error. The distances between reference points on the polished surface were measured using digital calipers. One-way analysis of variance was conducted for statistical analysis. The adaptation, as measured by the root mean square error, varied significantly among denture bases with different build angles. The distances between the anterior and posterior reference points of the polished surface were also significantly different. However, within the limitations of this study, the variations in adaptations and dimensional accuracy across different build angles were within clinically acceptable ranges. In clinical practice, the print angle can be adjusted based on factors, such as printing time, resin consumption, and the number of denture bases being printed simultaneously.
- 30 August 2024
- Published by MDPI AG in Preprints.org
Open AccessFour Different Build Angles in 3D-Printed Complete Denture Bases: A Comparative In Vitro Study
In this study, we aimed to investigate the differences in tissue surface adaptation and the variations in distances between reference points on the polished surfaces of 3D-printed denture bases with different build angles. The build angles were 0°, 30°, 60°, and 90°, with 15 denture bases printed for each angle. Using the Geomagic Control® software, a 3D best-fit alignment was conducted between the denture base tissue surface and the reference shape of the edentulous maxilla model to calculate the root mean square error. The distances between reference points on the polished surface were measured using digital calipers. One-way analysis of variance was conducted for statistical analysis. The adaptation, as measured by the root mean square error, varied significantly among denture bases with different build angles. The distances between the anterior and posterior reference points of the polished surface were also significantly different. However, within the limitations of this study, the variations in adaptations and dimensional accuracy across different build angles were within clinically acceptable ranges. In clinical practice, the print angle can be adjusted based on factors, such as printing time, resin consumption, and the number of denture bases being printed simultaneously.
- Open Access
- 1 January 2024
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 62 (2) , 174-182
A case of oral rehabilitation in a patient with severe tooth wear and occlusal plane collapse, utilizing maxillary fixed prosthesis and mandibular implant-assisted removable partial denture
안재형, et al. J Korean Acad Prosthodont. 2024 Apr;62(2):174-182. https://doi.org/10.4047/jkap.2024.62.2.174
- 1 January 2024
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 62 (2) , 174-182
Open AccessA case of oral rehabilitation in a patient with severe tooth wear and occlusal plane collapse, utilizing maxillary fixed prosthesis and mandibular implant-assisted removable partial denture
안재형, et al. J Korean Acad Prosthodont. 2024 Apr;62(2):174-182. https://doi.org/10.4047/jkap.2024.62.2.174
- Open Access
- 1 January 2024
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 62 (2) , 104-112
Digital interim immediate denture fabrication and implant-supported removable partial denture fabrication after multiple teeth extraction in patient with chronic periodontitis: a case report
박민재, et al. J Korean Acad Prosthodont. 2024 Apr;62(2):104-112. https://doi.org/10.4047/jkap.2024.62.2.104
- 1 January 2024
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 62 (2) , 104-112
Open AccessDigital interim immediate denture fabrication and implant-supported removable partial denture fabrication after multiple teeth extraction in patient with chronic periodontitis: a case report
박민재, et al. J Korean Acad Prosthodont. 2024 Apr;62(2):104-112. https://doi.org/10.4047/jkap.2024.62.2.104