Michael Kleber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michael Kleber has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Andreas Wagner
2 shared publications- Andreas Wagner
Karlsruhe Institute of Technology, Germany
2 shared publications - Benedict Brecht
Karlsruher Institut für Technologie (KIT); Institut für Meteorologie und Klimaforschung - Department Troposphärenforschung; Süddeutsches Klimabüro; 76344 Eggenstein-Leopoldshafen Hermann-von-Helmholtz-Platz 1
1 shared publication - Harald S. Müller
Institute of Building Materials and Concrete Structures, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
1 shared publication - Janus Willem Schipper
Institute of Meteorology and Climate Research - Troposphere Research (IMKTRO), Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
1 shared publication - Marcel Schweiker
Healthy Living Spaces lab, Institute for Occupational, Social and Environmental Medicine, Medical Faculty, RWTH Aachen University, Aachen, Germany
1 shared publication
Latest Publications
- Open Access
- 26 November 2019
- Published by Springer Nature in Scientific Data
- Vol. 6 (1) , 1-6
Long-term monitoring data from a naturally ventilated office building
Data was collected in the field, from an office building located in Frankfurt, Germany, over the period of 4 years. The building was designed as a low-energy building and featured natural ventilation for individual control of air quality as well as buoyancy-driven night ventilation in combination with a central atrium as a passive cooling strategy. The monitored data include in total 116 data points related to outdoor and indoor environmental data, energy related data, and data related to occupancy and occupant behaviour. Data points representing a state were logged with the real timestamp of the event taking place, all other data points were recorded in 10 minute intervals. Data were collected in 17 cell offices with a size of ~20 m2, facing either east or west). Each office has one fixed and two operable windows, internal top light windows between office and corridor (to allow for night ventilation into the atrium) and sun protection elements (operated both manually and automatically). Each office is occupied by one or two persons.
- 26 November 2019
- Published by Springer Nature in Scientific Data
- Vol. 6 (1) , 1-6
Open AccessLong-term monitoring data from a naturally ventilated office building
Data was collected in the field, from an office building located in Frankfurt, Germany, over the period of 4 years. The building was designed as a low-energy building and featured natural ventilation for individual control of air quality as well as buoyancy-driven night ventilation in combination with a central atrium as a passive cooling strategy. The monitored data include in total 116 data points related to outdoor and indoor environmental data, energy related data, and data related to occupancy and occupant behaviour. Data points representing a state were logged with the real timestamp of the event taking place, all other data points were recorded in 10 minute intervals. Data were collected in 17 cell offices with a size of ~20 m2, facing either east or west). Each office has one fixed and two operable windows, internal top light windows between office and corridor (to allow for night ventilation into the atrium) and sun protection elements (operated both manually and automatically). Each office is occupied by one or two persons.
- 1 January 2018
- Published by Elsevier in Building and Environment
- Vol. 128, 216-224
Investigation of indoor thermal comfort in warm-humid conditions at a German climate test facility
- 1 January 2018
- Published by Elsevier in Building and Environment
- Vol. 128, 216-224
Investigation of indoor thermal comfort in warm-humid conditions at a German climate test facility