Lei Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lei Li has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Yu-Chung Chang
School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99163, USA
8 shared publications- Li-Ju Wang
School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164, USA
6 shared publications Rongrong Sun
School of Mechanical and Materials Engineering, Washington State University College of Engineering and Architecture, Pullman, Washington, UNITED STATES
6 shared publicationsMojtaba Falahati
School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99163, USA
4 shared publications- Yuehe Lin
Washington State University
3 shared publications Allen Yi
Department of Integrated Systems Engineering, The Ohio State University, Columbus, Ohio 43210, USA
2 shared publications
Latest Publications
- Open Access
- 4 February 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (2) , 51
Portable 3D-Printed Paper Microfluidic System with a Smartphone Reader for Fast and Reliable Copper Ion Monitoring
Copper ions (Cu2+) are the third most essential transition metal ions critical to human health. Rapid detection of Cu2+ in water and biological fluids is of significant importance. In this study, we develop a sensitive multi-channel paper microfluidic device integrated with a 3D-printed smartphone-based colorimetric reader for the rapid detection of Cu2+. A novel rhodamine derivative, 1-(N,N-dichloromethine) amino-4-rhodamine B hydrazine-benzimide (RBCl), exhibiting high selectivity and sensitivity to Cu2+, was synthesized and applied as the detection reagent. The interaction mechanism between RBCl and Cu2+ was investigated, revealing a structural transition from a colorless spirolactam (closed-ring) to an open-ring amide structure, resulting in a pink color upon Cu2+ binding. A multi-channel paper microfluidic device with eight detection zones was fabricated, enabling the simultaneous analysis of eight samples. To enhance portability and quantification, a 3D-printed smartphone colorimetric reader was integrated, providing a rapid and efficient detection platform. The system achieved highly specific Cu2+ detection within 2 min, with a detection limit as low as 1.51 ng/mL, meeting water monitoring standards in most countries. Excellent recoveries were demonstrated in real samples, including tap water, river water, blood serum, and urine diluent. This integrated paper microfluidic system is highly sensitive and specific, offering a promising solution for water quality monitoring and health assessment through its rapid sample-to-answer capability.
- 4 February 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (2) , 51
Open AccessPortable 3D-Printed Paper Microfluidic System with a Smartphone Reader for Fast and Reliable Copper Ion Monitoring
Copper ions (Cu2+) are the third most essential transition metal ions critical to human health. Rapid detection of Cu2+ in water and biological fluids is of significant importance. In this study, we develop a sensitive multi-channel paper microfluidic device integrated with a 3D-printed smartphone-based colorimetric reader for the rapid detection of Cu2+. A novel rhodamine derivative, 1-(N,N-dichloromethine) amino-4-rhodamine B hydrazine-benzimide (RBCl), exhibiting high selectivity and sensitivity to Cu2+, was synthesized and applied as the detection reagent. The interaction mechanism between RBCl and Cu2+ was investigated, revealing a structural transition from a colorless spirolactam (closed-ring) to an open-ring amide structure, resulting in a pink color upon Cu2+ binding. A multi-channel paper microfluidic device with eight detection zones was fabricated, enabling the simultaneous analysis of eight samples. To enhance portability and quantification, a 3D-printed smartphone colorimetric reader was integrated, providing a rapid and efficient detection platform. The system achieved highly specific Cu2+ detection within 2 min, with a detection limit as low as 1.51 ng/mL, meeting water monitoring standards in most countries. Excellent recoveries were demonstrated in real samples, including tap water, river water, blood serum, and urine diluent. This integrated paper microfluidic system is highly sensitive and specific, offering a promising solution for water quality monitoring and health assessment through its rapid sample-to-answer capability.
- 13 March 2021
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 4 (3) , 2806-2819
Ultrafast Detection of Exosomal RNAs via Cationic Lipoplex Nanoparticles in a Micromixer Biochip for Cancer Diagnosis
Exosomes are cell-derived, nanosized extracellular vesicles for intercellular communication. Exosomal RNAs have been shown as one type of promising cancer liquid biopsy biomarkers. Conventional methods to characterize exosomal RNAs such as quantitative reverse transcription polymerase chain reaction (qRT-PCR) are limited by low sensitivity, large sample consumption, time-consuming process, and high cost. Many technologies have been developed to overcome these challenges; however, many hours are still required to complete the assays, especially when exosome lysis and RNA extraction are required. We have developed a microfluidic cationic lipoplex nanoparticles (mCLN) assay that utilizes a micromixer biochip to allow for the effective capture of exosomes by cationic lipoplex nanoparticles and thus enables ultrafast and sensitive exosomal RNA detection for cancer diagnosis. The sensing performance and diagnostic performance of the mCLN assay were investigated using non-small cell lung cancer (NSCLC) as the disease model and exosomal microRNA-21 and TTF-1 mRNA as the biomarkers. The limits of detection of the mCLN assay were 2.06 × 109 and 3.71 × 109 exosomes/mL for microRNA-21 and TTF-1 mRNA, respectively, indicating that the mCLN assay may require as low as 1 μL of serum for exosomal RNA detection. The mCLN assay successfully distinguished NSCLC from normal controls by detecting significantly higher microRNA-21 and TTF-1 mRNA levels in exosomes from both NSCLC patient serum samples and A549 NSCLC cells than those from normal controls and BEAS-2B normal bronchial epithelial cells. Compared with conventional qRT-PCR assay, the mCLN assay showed a higher diagnostic accuracy in lung cancer, required less sample volume (30 vs 100 μL), and consumed much less time (10 min vs 4 h).
- 13 March 2021
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 4 (3) , 2806-2819
Ultrafast Detection of Exosomal RNAs via Cationic Lipoplex Nanoparticles in a Micromixer Biochip for Cancer Diagnosis
Exosomes are cell-derived, nanosized extracellular vesicles for intercellular communication. Exosomal RNAs have been shown as one type of promising cancer liquid biopsy biomarkers. Conventional methods to characterize exosomal RNAs such as quantitative reverse transcription polymerase chain reaction (qRT-PCR) are limited by low sensitivity, large sample consumption, time-consuming process, and high cost. Many technologies have been developed to overcome these challenges; however, many hours are still required to complete the assays, especially when exosome lysis and RNA extraction are required. We have developed a microfluidic cationic lipoplex nanoparticles (mCLN) assay that utilizes a micromixer biochip to allow for the effective capture of exosomes by cationic lipoplex nanoparticles and thus enables ultrafast and sensitive exosomal RNA detection for cancer diagnosis. The sensing performance and diagnostic performance of the mCLN assay were investigated using non-small cell lung cancer (NSCLC) as the disease model and exosomal microRNA-21 and TTF-1 mRNA as the biomarkers. The limits of detection of the mCLN assay were 2.06 × 109 and 3.71 × 109 exosomes/mL for microRNA-21 and TTF-1 mRNA, respectively, indicating that the mCLN assay may require as low as 1 μL of serum for exosomal RNA detection. The mCLN assay successfully distinguished NSCLC from normal controls by detecting significantly higher microRNA-21 and TTF-1 mRNA levels in exosomes from both NSCLC patient serum samples and A549 NSCLC cells than those from normal controls and BEAS-2B normal bronchial epithelial cells. Compared with conventional qRT-PCR assay, the mCLN assay showed a higher diagnostic accuracy in lung cancer, required less sample volume (30 vs 100 μL), and consumed much less time (10 min vs 4 h).
- 9 March 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (8) , 2632-2640
Fabrication of aspherical polymeric lenses using tunable ferrogel molds
The majority of optical lenses have spherical surface profiles because they are convenient to fabricate. Replacing spherical optics with aspheric optics leads to smaller size, lighter weight, and less complicated optical systems with a superior imaging quality. However, fabrication of aspheric lenses is expensive and time-consuming. Here, we introduce a straightforward and low-cost casting method to fabricate polymeric aspheric lenses. An elastomeric ferrogel was formed into an aspherical profile by using a designed magnetic field and then was used as a mold. Different types of aspherical profiles from parabola to hyperbola can be formed with this method by tuning the magnetic field. A home-built Shack–Hartmann sensor was employed to characterize the cast polymeric lenses. The effects of magnetic field intensity, gradient of the magnetic field, and magnetic susceptibility of the ferrogel on the lens profiles were investigated. This technique can be used for rapid-forming polymeric aspherical lenses with different sizes and shapes.
- 9 March 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (8) , 2632-2640
Fabrication of aspherical polymeric lenses using tunable ferrogel molds
The majority of optical lenses have spherical surface profiles because they are convenient to fabricate. Replacing spherical optics with aspheric optics leads to smaller size, lighter weight, and less complicated optical systems with a superior imaging quality. However, fabrication of aspheric lenses is expensive and time-consuming. Here, we introduce a straightforward and low-cost casting method to fabricate polymeric aspheric lenses. An elastomeric ferrogel was formed into an aspherical profile by using a designed magnetic field and then was used as a mold. Different types of aspherical profiles from parabola to hyperbola can be formed with this method by tuning the magnetic field. A home-built Shack–Hartmann sensor was employed to characterize the cast polymeric lenses. The effects of magnetic field intensity, gradient of the magnetic field, and magnetic susceptibility of the ferrogel on the lens profiles were investigated. This technique can be used for rapid-forming polymeric aspherical lenses with different sizes and shapes.
- 30 August 2019
- Published by Springer Nature
- Vol. 2050, 21-27
Micromachining of Polymeric Microfluidic Micro/Nanoelectroporation Device
Micro/nanochannel electroporation can deliver gene/drug into single cell with precise dosage control and much higher cell viability compared to traditional bulk electroporation. However, single cell micro/nanochannel electroporation has the problems of low efficiency and complicated operation. By integrating microfluidic with micro/nanochannel electroporation, a large number of cells can be processed within a short time. In this chapter, we provide a detailed protocol of fabrication microfluidic nanochannel electroporation devices. The fabrication of this microfluidic nanochannel electroporation device integrates soft lithography, DNA combing and imprinting, and micromilling. This device is appropriate for gene/drug delivery to a batch of cells. It has the advantages of both the single cell nanochannel electroporation and microfluidic based cell manipulation. The procedures of device fabrication, holder fabrication, cell trapping, and electroporation are included in this protocol.
- 30 August 2019
- Published by Springer Nature
- Vol. 2050, 21-27
Micromachining of Polymeric Microfluidic Micro/Nanoelectroporation Device
Micro/nanochannel electroporation can deliver gene/drug into single cell with precise dosage control and much higher cell viability compared to traditional bulk electroporation. However, single cell micro/nanochannel electroporation has the problems of low efficiency and complicated operation. By integrating microfluidic with micro/nanochannel electroporation, a large number of cells can be processed within a short time. In this chapter, we provide a detailed protocol of fabrication microfluidic nanochannel electroporation devices. The fabrication of this microfluidic nanochannel electroporation device integrates soft lithography, DNA combing and imprinting, and micromilling. This device is appropriate for gene/drug delivery to a batch of cells. It has the advantages of both the single cell nanochannel electroporation and microfluidic based cell manipulation. The procedures of device fabrication, holder fabrication, cell trapping, and electroporation are included in this protocol.
- 2 August 2019
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 7 (18) , 15304-15310
No Such Thing as Trash: A 3D-Printable Polymer Composite Composed of Oil-Extracted Spent Coffee Grounds and Polylactic Acid with Enhanced Impact Toughness
- 2 August 2019
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 7 (18) , 15304-15310
No Such Thing as Trash: A 3D-Printable Polymer Composite Composed of Oil-Extracted Spent Coffee Grounds and Polylactic Acid with Enhanced Impact Toughness
- Open Access
- 20 May 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 114 (20) , 203701
Fabrication of polymeric lenses using magnetic liquid molds
Traditional molding and casting processes in optical manufacturing require sophisticated and expensive molds and molding equipment. In this work, magnetic liquid droplets were used as soft and deformable molds. The magnetic drop within an immiscible polymeric resin forms a conical shape at the interface due to the equilibrium of magnetostatic force and surface tension, which results in a plano–concave lens after curing. An apparatus was assembled to control the amplitude and gradient of the magnetic field. A Shack-Hartmann sensor was employed to measure the focal length of the formed polydimethylsiloxane lenses. The effects of magnetic field intensity, gradient of the magnetic field, and magnetic susceptibility were investigated. This technique is low cost, rapid, and straightforward and can be used for forming lenses with different sizes and shapes.
- 20 May 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 114 (20) , 203701
Open AccessFabrication of polymeric lenses using magnetic liquid molds
Traditional molding and casting processes in optical manufacturing require sophisticated and expensive molds and molding equipment. In this work, magnetic liquid droplets were used as soft and deformable molds. The magnetic drop within an immiscible polymeric resin forms a conical shape at the interface due to the equilibrium of magnetostatic force and surface tension, which results in a plano–concave lens after curing. An apparatus was assembled to control the amplitude and gradient of the magnetic field. A Shack-Hartmann sensor was employed to measure the focal length of the formed polydimethylsiloxane lenses. The effects of magnetic field intensity, gradient of the magnetic field, and magnetic susceptibility were investigated. This technique is low cost, rapid, and straightforward and can be used for forming lenses with different sizes and shapes.
- 24 April 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 292, 263-269
A smartphone based device for the detection of sulfane sulfurs in biological systems
- 24 April 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 292, 263-269
A smartphone based device for the detection of sulfane sulfurs in biological systems
- 1 December 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 275, 300-305
An ultra low-cost smartphone device for in-situ monitoring of acute organophosphorus poisoning for agricultural workers
- 1 December 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 275, 300-305
An ultra low-cost smartphone device for in-situ monitoring of acute organophosphorus poisoning for agricultural workers
- 1 October 2018
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 549 (1-2) , 13-20
Facile continuous production of soy peptide nanogels via nanoscale flash desolvation for drug entrapment
- 1 October 2018
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 549 (1-2) , 13-20
Facile continuous production of soy peptide nanogels via nanoscale flash desolvation for drug entrapment
- 14 August 2018
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 28 (11) , 115005
Numerical and experimental study on multiphase printing of polymeric biconvex micro lenses
Polymeric micro lenses are popularly used in optical systems in recent decades due to the advantages of light weight and low-cost compared to traditional glass lenses. Multiphase printing method is a novel polymeric micro lens manufacturing method with advantage of low-cost and high accuracy. To precisely control the fabrication parameters, it is important to study the influence of forming conditions to the lens shape. This work developed and validated a numerical model that utilizes Young-Laplace equation, Navier-Stokes equation and forces balance to calculate the profile of the printed polymeric micro lens and to study the effects of different manufacturing parameters. Experimental validation shows that the numerical model can achieve accurate lens geometry by knowing printing conditions. This numerical methods will significantly simplify the manufacturing process of polymeric lenses and show promising potentials of the multiphase printing method.
- 14 August 2018
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 28 (11) , 115005
Numerical and experimental study on multiphase printing of polymeric biconvex micro lenses
Polymeric micro lenses are popularly used in optical systems in recent decades due to the advantages of light weight and low-cost compared to traditional glass lenses. Multiphase printing method is a novel polymeric micro lens manufacturing method with advantage of low-cost and high accuracy. To precisely control the fabrication parameters, it is important to study the influence of forming conditions to the lens shape. This work developed and validated a numerical model that utilizes Young-Laplace equation, Navier-Stokes equation and forces balance to calculate the profile of the printed polymeric micro lens and to study the effects of different manufacturing parameters. Experimental validation shows that the numerical model can achieve accurate lens geometry by knowing printing conditions. This numerical methods will significantly simplify the manufacturing process of polymeric lenses and show promising potentials of the multiphase printing method.