WSWilliam H. Sauer

William H. Sauer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


William H. Sauer has a total of 172 co-authors. Here are the top co-authors by number of shared publications:

  • Duy Thai Nguyen

    Section of Cardiac Electrophysiology, Division of Cardiovascular Medicine Stanford University Stanford California USA

    9 shared publications
  • Paul C. Zei

    Cardiac Arrhythmia Service, Division of Cardiovascular Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA (P.C.Z.).

    6 shared publications
  • Wendy S. Tzou

    Cardiac Electrophysiology Section, Division of Cardiology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA

    6 shared publications
  • Lijun Zheng

    Section of Cardiac Electrophysiology, Division of Cardiology University of Colorado Aurora Colorado USA

    5 shared publications
  • Ryan T. Borne

    Section of Cardiac Electrophysiology, Division of Cardiology University of Colorado Aurora Colorado

    5 shared publications
  • Alejandro Velasco

    Health San Antonio San Antonio Texas USA

    4 shared publications

Latest Publications

  • Isoproterenol for Unmasking Dormant Conduction and Non‐Pulmonary Vein Triggers During Atrial Fibrillation Ablation: Prospective Multicenter Study

    by Saumil R. Oza, Daniela Hincapie, Manasvi Gupta, Allyson L. Varley, Christopher Thorne, Joshua R. Silverstein, Mohamed Gabr, Amit J. Thosani, Andres F. Miranda‐Arboleda, Jose Osorio, et al.

    Background: Pulmonary vein (PV) reconnection and the onset of non‐PV triggers are frequently the cause of atrial fibrillation (AF) recurrence after radiofrequency catheter ablation (RFCA). The effectiveness of using isoproterenol for unmasking dormant conduction and non‐PV‐triggers during AF RFCA and its effect on improving procedural and clinical outcomes is still controversial.Objective: To evaluate the effectiveness of isoproterenol for unmasking dormant conduction and non‐PV triggers during RFCA for paroxysmal AF (PAF) and its effects on procedural and long‐term clinical outcomes.Methods: In this prospective multicenter cohort from the REAL‐AF registry, patients who underwent RFCA for PAF with and without isoproterenol administration from January 2018 to May 2023 were included. The primary efficacy outcome was freedom from all‐atrial arrhythmia at 12‐month follow‐up. Secondary outcomes included procedural and long‐term clinical outcomes, and procedure‐related complications.Results: A total of 1102 patients were included (isoproterenol = 325 vs. control = 777) (mean age 66.73 ± 10.19 years; 53.05% male). There were no differences in baseline characteristics between the groups. Dormant conduction/non‐PV triggers with isoproterenol were observed in 10.2% of the patients. Isoproterenol administration was associated with increased procedural times (109 (83–137.5) vs. 96 (74–122), p = 0.002), and decreased rates of first‐pass PV isolation (74.84% vs. 80.14%, p = 0.007). There were no differences in freedom from all‐atrial arrhythmias (HR 0.87, 95% CI [0.61–1.24], p = 0.4) or long‐term clinical outcomes at 12 months of follow‐up between the groups.Conclusion: In patients undergoing RFCA for PAF, the use of isoproterenol was associated with increased procedural times and more extensive ablation, without improved clinical outcomes at 12‐month follow‐up.


  • Procedural and Clinical Outcomes of High‐Frequency Low‐Tidal Volume Ventilation Plus Rapid‐Atrial Pacing in Paroxysmal Atrial Fibrillation Ablation

    by Paul C. Zei, Daniela Hincapie, Joan Rodriguez‐Taveras, Jose Osorio, Isabella Alviz, Andres F. Miranda‐Arboleda, Mohamed Gabr, Christopher Thorne, Joshua R. Silverstein, Amit J. Thosani, et al.

    Background: High‐frequency low‐tidal‐volume (HFLTV) ventilation is a safe and cost‐effective strategy that improves catheter stability, first‐pass pulmonary vein isolation, and freedom from all‐atrial arrhythmias during radiofrequency catheter ablation (RFCA) of paroxysmal and persistent atrial fibrillation (AF). However, the incremental value of adding rapid‐atrial pacing (RAP) to HFLTV‐ventilation has not yet been determined.Objective: To evaluate the effect of HFLTV‐ventilation plus RAP during RFCA of paroxysmal AF on procedural and long‐term clinical outcomes compared to HFLTV‐ventilation alone.Methods: Patients from the REAL‐AF prospective multicenter registry, who underwent RFCA of paroxysmal AF using either HFLTV + RAP (500–600 msec) or HFLTV ventilation alone from April 2020 to February 2023 were included. The primary outcome was freedom from all‐atrial arrhythmias at 12‐month follow‐up. Secondary outcomes included procedural characteristics, long‐term clinical outcomes, and procedure‐related complications.Results: A total of 545 patients were included in the analysis (HFLTV + RAP = 327 vs. HFLTV = 218). There were no significant differences in baseline characteristics between the groups. No differences were observed in procedural (HFLTV + RAP 74 [57–98] vs. HFLTV 66 [53–85.75] min, p = 0.617) and RF (HFLTV + RAP 15.15 [11.22–21.22] vs. HFLTV 13.99 [11.04–17.13] min, p = 0.620) times. Both groups showed a similar freedom from all‐atrial arrhythmias at 12‐month follow‐up (HFLTV + RAP 82.68% vs. HFLTV 86.52%, HR = 1.43, 95% CI [0.94–2.16], p = 0.093). There were no significant differences in freedom from AF‐related symptoms (HFLTV + RAP 91.4% vs. HFLTV 93.1%, p = 0.476) or AF‐related hospitalizations (HFLTV + RAP 98.5% vs. HFLTV 97.2%, p = 0.320). Procedure‐related complications were low in both groups (HFLTV + RAP 0.6% vs. HFLTV 0%, p = 0.247).Conclusion: In patients undergoing RFCA for paroxysmal AF, adding RAP to HFLTV‐ventilation was not associated with improved procedural and long‐term clinical outcomes.


  • Open Access

    Isoproterenol for Unmasking Dormant Conduction and Non-Pulmonary Vein Triggers During Atrial Fibrillation Ablation: Prospective Multicenter Study

    by Saumil Oza, Daniela Hincapie, Manasvi Gupta, Allyson L. Varley, Christopher Thorne, Josh Silverstein, Mohamed Gabr, Amit Thosani, Andres F. Miranda-Arboleda, Jose Osorio, et al.

  • Open Access

    Procedural and Clinical Outcomes of High-Frequency Low-Tidal Volume Ventilation Plus Rapid-Atrial Pacing in Paroxysmal Atrial Fibrillation Ablation

    by Paul Zei, Joan Rodriguez-Taveras, Daniela Hincapie, Jose Osorio, Isabella Alviz, Andres F. Miranda-Arboleda, Mohamed Gabr, Christopher Thorne, Josh Silverstein, Amit Thosani, et al.

    Background: High-frequency low-tidal-volume (HFLTV) ventilation is a safe and cost-effective strategy that improves catheter stability, first-pass pulmonary vein isolation, and freedom from all-atrial arrhythmias during radiofrequency catheter ablation (RFCA) of paroxysmal and persistent atrial fibrillation (AF). However, the incremental value of adding rapid-atrial pacing (RAP) to HFLTV-ventilation has not yet been determined. Objective: To evaluate the effect of HFLTV-ventilation plus RAP during RFCA of paroxysmal AF on procedural and long-term clinical outcomes compared to HFLTV-ventilation alone. Methods: Patients from the REAL-AF prospective multicenter registry, who underwent RFCA of paroxysmal AF using either HFLTV+RAP (500-600 msec) or HFLTV ventilation alone from April 2020 to February 2023 were included. The primary outcome was freedom from all-atrial arrhythmias at 12-month follow-up. Secondary outcomes included procedural characteristics, long-term clinical outcomes, and procedure-related complications. Results: A total of 545 patients were included in the analysis (HFLTV+RAP=327 vs. HFLTV=218). There were no significant differences in baseline characteristics between the groups. No differences were observed in procedural (HFLTV+RAP 74 [57-98] vs. HFLTV 66 [53-85.75] min, p=0.617) and RF (HFLTV+RAP 15.15 [11.22-21.22] vs. HFLTV 13.99 [11.04-17.13] min, p=0.620) times. Both groups showed a similar freedom from all-atrial arrhythmias at 12-month follow-up (HFLTV+RAP 82.68% vs. HFLTV 86.52%, HR=1.43, 95% CI [0.94-2.16], p=0.093). There were no significant differences in freedom from AF-related symptoms (HFLTV+RAP 91.4% vs. HFLTV 93.1%, p=0.476) or AF-related hospitalizations (HFLTV+RAP 98.5% vs. HFLTV 97.2%, p=0.320). Procedure-related complications were low in both groups (HFLTV+RAP 0.6% vs. HFLTV 0%, p=0.247). Conclusion: In patients undergoing RFCA for paroxysmal AF, adding RAP to HFLTV-ventilation was not associated with improved procedural and long-term clinical outcomes.

  • Local calcium chloride infusion after pulsed field ablation enhances acute efficacy of cardiac electroporation

    by Taro Koya, Naoto Otsuka, Jason A. Tri, William H. Sauer, Samuel J. Asirvatham, Duy T. Nguyen

    Introduction: Pulsed field ablation (PFA) has emerged as an innovative therapy for cardiac arrhythmias. Drawing parallels with PFA's application in solid tumors, calcium chloride (CaCl2) as an adjuvant therapy, known as calcium electroporation, may amplify PFA's apoptotic effects. We propose that PFA in the atrium could enhance calcium uptake through PFA‐created pores, thereby increasing ablation efficacy even at reduced power levels by exploiting PFA's permeabilization effects.Methods: We conducted in vivo ablations on the atria of seven pigs using low PFA power (250 V, 20 μs for 50 pulses at 200 ms intervals). Post‐PFA, we randomly administered an infusion of either 200 mg/2 ml CaCl2 (calcium group) or saline (control) directly to the ablation site via the catheter tip. We evaluated reduction in electrogram voltage amplitude, electrocardiography (ECG) parameters, ablation lesion parameters, and histology after PFA.Results: Nineteen lesions from control and calcium groups were examined. Control lesions showed no voltage decrease post‐PFA, whereas calcium‐treated lesions exhibited a significant voltage reduction. Gross pathology indicated marked differences in maximum lesion surface diameter, depth, and volume between the lesion groups. Histologically, calcium group lesions were characterized by a more severe acute PFA response with contraction band necrosis, myocytolysis and nuclear pyknosis in adjacent myocardium, in addition to microhemorrhages.Conclusion: Infusing calcium chloride locally after PFA markedly improves the immediate efficacy of electroporation in porcine atria. This study suggests that calcium electroporation could bolster PFA outcomes without higher energy levels, potentially diminishing associated risks. These preliminary findings warrant further research into the long‐term efficacy and potential clinical application of calcium electroporation in PFA.


  • Cover Image, Volume 35, Issue 9

    by Leah A. John, Sanjay Divakaran, Ron Blankstein, Uyanga Batnyam, Pal Suranyi, Mathew Gregoski, Hubert Cochet, Jean‐Marc Peyrat, Nicolas Cedlink, Luis Kabongo, et al.

  • Septal late enhancement by cardiac CT is associated with repeat ablation in nonischemic cardiomyopathy patients

    by Leah A. John, Sanjay Divakaran, Ron Blankstein, Uyanga Batnyam, Pal Suranyi, Mathew Gregoski, Hubert Cochet, Jean‐Marc Peyrat, Nicolas Cedlink, Luis Kabongo, et al.

    Introduction: Scar substrate in nonischemic cardiomyopathy (NICM) patients is often difficult to identify. Advances in cardiac imaging, especially using late iodine‐enhanced computed tomography (LIE‐CT), allow better characterization of scars giving rise to ventricular tachycardia (VT). Currently, there are limited data on clinical correlates of CT‐derived scar substrates in NICM. We sought assess the relationship between scar location on LIE‐CT and outcomes after radiofrequency catheter ablation (RFCA) in NICM patients with VT.Methods: From 2020 to 2022, consecutive patients with NICM undergoing VT RFCA with integration of cardiac CT scar modeling (inHeart, Pessac, France) were included at two US tertiary care centers. The CT protocol included both arterial‐enhanced imaging for anatomical modeling and LIE‐CT for scar assessment. The distribution of substrate on CT was analyzed in relation to patient outcomes, with primary endpoints being VT recurrence and the need for repeat ablation procedure.Results: Sixty patients were included (age 64 ± 12 years, 90% men). Over a median follow‐up of 120 days (interquartile range [IQR]: 41–365), repeat ablation procedures were required in 32 (53%). VT recurrence occurred in 46 (77%), with a median time to recurrence of 40 days (IQR: 8–65). CT‐derived total scar volume positively correlated with intrinsic QRS duration (r = .34, p = 0.008). Septal scar was found on CT in 34 (57%), and lateral scar in 40 (7%). On univariate logistic regression, septal scar was associated with increased odds of repeat ablation (odds ratio [OR]: 2.9 [1.0–8.4]; p = 0.046), while lateral scar was not (OR: 0.9 [0.3–2.7]; p = 0.855). Septal scar better predicted VT recurrence when compared to lateral scar, but neither were statistically significant (septal scar OR: 3.0 [0.9–10.7]; p = 0.078; lateral scar OR: 1.7 [0.5–5.9]; p = 0.391).Conclusion: In this tertiary care referral population, patients with NICM undergoing VT catheter ablation with septal LIE‐CT have nearly threefold increased risk of need for repeat ablation.


  • Open Access

    Consistency of ablations with trainee and increasing independence during fellowship training—Analysis of ablation data by CARTONET

    by John Whitaker, Tina D. Hunter, Jane Carsey, William H. Thatcher, Don Yungher, Stanislav Goldberg, Christina Kaneko, Mati Amit, Omar Kreidieh, Clinton Thurber, et al.

    Introduction: Training in clinical cardiac electrophysiology (CCEP) involves the development of catheter handling skills to safely deliver effective treatment. Objective data from analysis of ablation data for evaluating trainee of CCEP procedures has not previously been possible. Using the artificial intelligence cloud‐based system (CARTONET), we assessed the impact of trainee progress through ablation procedural quality.Methods: Lesion‐ and procedure‐level data from all de novo atrial fibrillation (AF) and cavotricuspid isthmus (CTI) ablations involving first‐year (Y1) or second‐year (Y2) fellows across a full year of fellowship was curated within Cartonet. Lesions were automatically assigned to anatomic locations.Results: Lesion characteristics, including contact force, catheter stability, impedance drop, ablation index value, and interlesion time/distance were similar over each training year. Anatomic location and supervising operator significantly affected catheter stability. The proportion of lesion sets delivered independently and of lesions delivered by the trainee increased steadily from the first quartile of Y1 to the last quartile of Y2. Trainee perception of difficult regions did not correspond to objective measures.Conclusion: Objective ablation data from Cartonet showed that the progression of trainees through CCEP training does not impact lesion‐level measures of treatment efficacy (i.e., catheter stability, impedance drop). Data demonstrates increasing independence over a training fellowship. Analyses like these could be useful to inform individualized training programs and to track trainee's progress. It may also be a useful quality assurance tool for ensuring ongoing consistency of treatment delivered within training institutions.


  • Ambient circulation surrounding an ablation catheter tip affects ablation lesion characteristics

    by Udi Nussinovitch, Paul Wang, Meghedi Babakhanian, Sanjiv M. Narayan, Mohan Viswanathan, Nitish Badhwar, Lijun Zheng, William H. Sauer, Duy T. Nguyen

    Introduction: The association between ambient circulating environments (CEs) and ablation lesions has been largely underexplored.Methods: Viable bovine myocardium was placed in a saline bath in an ex vivo endocardial model. Radiofrequency (RF) ablation was performed using three different ablation catheters: 3.5 mm open irrigated (OI), 4, and 8 mm. Variable flow rates of surrounding bath fluids were applied to simulate standard flow, high flow, and no flow. For in vivo epicardial ablation, 24 rats underwent a single OI ablation and performed with circulating saline (30 ml/min; n = 12), versus those immersed in saline without circulation (n = 12).Results: High flow reduced ablation lesion volumes for all three catheters. In no‐flow endocardial CE, both 4 mm and OI catheters produced smaller lesions compared with standard flow. However, the 8 mm catheter produced the largest lesions in a no‐flow CE. Ablation performed in an in vivo model with CE resulted in smaller lesions compared with ablation performed in a no‐flow environment. No statistically significant differences in steam pops were found among the groups.Conclusion: A higher endocardial CE flow can decrease RF effectiveness. Cardiac tissue subjected to no endocardial CE flow may also limit RF for 4 mm catheters, but not for OI catheters; these findings may have implications for RF ablation safety and efficacy, especially in the epicardial space without circulating fluid or in the endocardium under varying flow conditions.


  • Evaluating temperature gradients across the posterior left atrium with radiofrequency ablation

    by Amneet Sandhu, Blair Holman, Steven Lammers, Lukasz Cerbin, Christopher Barrett, Rafay Sabzwari, Lohit Garg, Matthew M. Zipse, Alexis Z. Tumolo, Ryan G. Aleong, et al.

    Introduction: Esophageal injury is a well‐known complication associated with catheter ablation. Though novel methods to mitigate esophageal injury have been developed, few studies have evaluated temperature gradients with catheter ablation across the posterior wall of the left atrium, interstitium, and esophagus.Methods: To investigate temperature gradients across the tissue, we developed a porcine heart–esophageal model to perform ex vivo catheter ablation on the posterior wall of the left atrium (LA), with juxtaposed interstitial tissue and esophagus. Circulating saline (5 L/min) was used to mimic blood flow along the LA and alteration of ionic content to modulate impedance. Thermistors along the region of interest were used to analyze temperature gradients. Varying time and power, radiofrequency (RF) ablation lesions were applied with an externally irrigated ablation catheter. Ablation strategies were divided into standard approaches (SAs, 10–15 g, 25–35 W, 30 s) or high‐power short duration (HPSD, 10–15 g, 40–50 W, 10 s). Temperature gradients, time to the maximum measured temperature, and the relationship between measured temperature as a function of distance from the site of ablation was analyzed.Results: In total, five experiments were conducted each utilizing new porcine posterior LA wall‐esophageal specimens for RF ablation (n = 60 lesions each for SA and HPSD). For both SA and HPSD, maximum temperature rise from baseline was markedly higher at the anterior wall (AW) of the esophagus compared to the esophageal lumen (SA: 4.29°C vs. 0.41°C, p < .0001 and HPSD: 3.13°C vs. 0.28°C, p < .0001). Across ablation strategies, the average temperature rise at the AW of the esophagus was significantly higher with SA relative to HPSD ablation (4.29°C vs. 3.13°C, p = .01). From the start of ablation, the average time to reach a maximum temperature as measured at the AW of the esophagus with SA was 36.49 ± 12.12 s, compared to 16.57 ± 4.54 s with HPSD ablation, p < .0001. Fit to a linear scale, a 0.37°C drop in temperature was seen for every 1 cm increase in distance from the site of ablation and thermistor location at the AW of the esophagus.Conclusion: Both SA and HPSD ablation strategies resulted in markedly higher temperatures measured at the AW of the esophagus compared to the esophageal lumen, raising concern about the value of clinical intraluminal temperature monitoring. The temperature rise at the AW was lower with HPSD. A significant time delay was seen to reach the maximum measured temperature and a modest increase in distance between the site of ablation and thermistor location impacted the accuracy of monitored temperatures.