Dieter Weber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dieter Weber has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Rafal E. Dunin-Borkowski
Forschungszentrum Jülich GmbH
8 shared publications - Alexander Clausen
Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons Forschungszentrum Jülich 52425 Jülich Germany
7 shared publications - Andrew Stewart
Department of Chemistry, University College London, 20 Gordon St, London, United Kingdom, WC1H 0AJ
3 shared publications - Andreas Schropp
Centre for X-Ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY 12 , Notkestraße 85, 22607 Hamburg
2 shared publications - Arya Bangun
IAS-8
2 shared publications - Christian G. Schroer
Deutsches Elektronen-Synchrotron DESY
2 shared publications
Latest Publications
- Open Access
Calibrating coordinate system alignment in a scanning transmission electron microscope using a digital twin
In four-dimensional scanning transmission electron microscopy (4D STEM) a focused beam is scanned over a specimen and a diffraction pattern is recorded at each position using a pixelated detector. During the experiment, it must be ensured that the scan coordinate system of the beam is correctly calibrated relative to the detector coordinate system. Various simplified and approximate models are used implicitly and explicitly for understanding and analyzing the recorded data, requiring translation between the physical reality of the instrument and the abstractions used in data interpretation. Here, we introduce a calibration method where interactive live data processing in combination with a digital twin is used to match a set of models and their parameters with the action of a real-world instrument.
Open AccessCalibrating coordinate system alignment in a scanning transmission electron microscope using a digital twin
In four-dimensional scanning transmission electron microscopy (4D STEM) a focused beam is scanned over a specimen and a diffraction pattern is recorded at each position using a pixelated detector. During the experiment, it must be ensured that the scan coordinate system of the beam is correctly calibrated relative to the detector coordinate system. Various simplified and approximate models are used implicitly and explicitly for understanding and analyzing the recorded data, requiring translation between the physical reality of the instrument and the abstractions used in data interpretation. Here, we introduce a calibration method where interactive live data processing in combination with a digital twin is used to match a set of models and their parameters with the action of a real-world instrument.
- Open Access
- 20 February 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (1) , 103-117
Live Iterative Ptychography
We demonstrate live-updating ptychographic reconstruction with the extended ptychographical iterative engine, an iterative ptychography method, during ongoing data acquisition. The reconstruction starts with a small subset of the total data, and as the acquisition proceeds the data used for reconstruction are extended. This creates a live-updating view of object and illumination that allows monitoring the ongoing experiment and adjusting parameters with quick turn around. This is particularly advantageous for long-running acquisitions. We show that such a gradual reconstruction yields interpretable results already with a small subset of the data. We show simulated live processing with various scan patterns, parallelized reconstruction, and real-world live processing at the hard X-ray ptychographic nanoanalytical microscope PtyNAMi at the PETRA III beamline.
- 20 February 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (1) , 103-117
Open AccessLive Iterative Ptychography
We demonstrate live-updating ptychographic reconstruction with the extended ptychographical iterative engine, an iterative ptychography method, during ongoing data acquisition. The reconstruction starts with a small subset of the total data, and as the acquisition proceeds the data used for reconstruction are extended. This creates a live-updating view of object and illumination that allows monitoring the ongoing experiment and adjusting parameters with quick turn around. This is particularly advantageous for long-running acquisitions. We show that such a gradual reconstruction yields interpretable results already with a small subset of the data. We show simulated live processing with various scan patterns, parallelized reconstruction, and real-world live processing at the hard X-ray ptychographic nanoanalytical microscope PtyNAMi at the PETRA III beamline.
- Open Access
Live Iterative Ptychography
We demonstrate live-updating ptychographic reconstruction with ePIE, an iterative ptychography method, during ongoing data acquisition. The reconstruction starts with a small subset of the total data, and as the acquisition proceeds the data used for reconstruction is extended. This creates a live-updating view of object and illumination that allows monitoring the ongoing experiment and adjusting parameters with quick turn-around. This is particularly advantageous for long-running acquisitions. We show that such a gradual reconstruction yields interpretable results already with a small subset of the data. We show simulated live processing with various scan patterns, parallelized reconstruction, and real-world live processing at the hard X-ray ptychographic nanoanalytical microscope PtyNAMi at the PETRA III beamline.
Open AccessLive Iterative Ptychography
We demonstrate live-updating ptychographic reconstruction with ePIE, an iterative ptychography method, during ongoing data acquisition. The reconstruction starts with a small subset of the total data, and as the acquisition proceeds the data used for reconstruction is extended. This creates a live-updating view of object and illumination that allows monitoring the ongoing experiment and adjusting parameters with quick turn-around. This is particularly advantageous for long-running acquisitions. We show that such a gradual reconstruction yields interpretable results already with a small subset of the data. We show simulated live processing with various scan patterns, parallelized reconstruction, and real-world live processing at the hard X-ray ptychographic nanoanalytical microscope PtyNAMi at the PETRA III beamline.
- Open Access
- 14 July 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (4) , 1267-1276
TEMGYM Basic: transmission electron microscopy simulation software for teaching and training of microscope operation
An interactive simulation of a transmission electron microscope (TEM) called TEMGYM Basic is developed here, which enables users to understand how to operate and control an electron beam without the need to access an instrument. TEMGYM Basic allows users to familiarize themselves with alignment procedures offline, reducing the time and money required to become a proficient TEM operator. In addition to teaching the basics of electron beam alignments, the software enables users to create bespoke microscope configurations and develop an understanding of how to operate the configurations without sitting at a microscope. TEMGYM Basic also creates static ray diagram figures for a given lens configuration. The available components include apertures, lenses, quadrupoles, deflectors and biprisms. The software design uses first-order ray transfer matrices to calculate ray paths through each electron microscope component, and the program is developed entirely in Python to facilitate compatibility with machine-learning packages for future exploration of automated control.
- 14 July 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (4) , 1267-1276
Open AccessTEMGYM Basic: transmission electron microscopy simulation software for teaching and training of microscope operation
An interactive simulation of a transmission electron microscope (TEM) called TEMGYM Basic is developed here, which enables users to understand how to operate and control an electron beam without the need to access an instrument. TEMGYM Basic allows users to familiarize themselves with alignment procedures offline, reducing the time and money required to become a proficient TEM operator. In addition to teaching the basics of electron beam alignments, the software enables users to create bespoke microscope configurations and develop an understanding of how to operate the configurations without sitting at a microscope. TEMGYM Basic also creates static ray diagram figures for a given lens configuration. The available components include apertures, lenses, quadrupoles, deflectors and biprisms. The software design uses first-order ray transfer matrices to calculate ray paths through each electron microscope component, and the program is developed entirely in Python to facilitate compatibility with machine-learning packages for future exploration of automated control.
- Open Access
- 8 March 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (3) , 994-1008
Wigner Distribution Deconvolution Adaptation for Live Ptychography Reconstruction
We propose a modification of Wigner distribution deconvolution (WDD) to support live processing ptychography. Live processing allows to reconstruct and display the specimen transmission function gradually while diffraction patterns are acquired. For this purpose, we reformulate WDD and apply a dimensionality reduction technique that reduces memory consumption and increases processing speed. We show numerically that this approach maintains the reconstruction quality of specimen transfer functions as well as reduces computational complexity during acquisition processes. Although we only present the reconstruction for scanning transmission electron microscopy datasets, in general, the live processing algorithm we present in this paper can be applied to real-time ptychographic reconstruction for different fields of application.
- 8 March 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (3) , 994-1008
Open AccessWigner Distribution Deconvolution Adaptation for Live Ptychography Reconstruction
We propose a modification of Wigner distribution deconvolution (WDD) to support live processing ptychography. Live processing allows to reconstruct and display the specimen transmission function gradually while diffraction patterns are acquired. For this purpose, we reformulate WDD and apply a dimensionality reduction technique that reduces memory consumption and increases processing speed. We show numerically that this approach maintains the reconstruction quality of specimen transfer functions as well as reduces computational complexity during acquisition processes. Although we only present the reconstruction for scanning transmission electron microscopy datasets, in general, the live processing algorithm we present in this paper can be applied to real-time ptychographic reconstruction for different fields of application.
- Open Access
- 12 January 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (1) , 427-436
Online Thickness Determination with Position Averaged Convergent Beam Electron Diffraction using Convolutional Neural Networks
Position averaged convergent beam electron diffraction (PACBED) is one of the most convenient and precise thickness determination techniques available in a scanning transmission electron microscope. The thickness is determined by finding the best match of the recorded PACBED pattern with a series of simulated diffraction patterns by visual inspection. The automatization of this process can be enhanced by convolutional neural networks (CNNs), making the method fast and easy to apply. However, the simulation of a synthetic dataset and the training of the CNNs carry a high computational cost. With the aim to simplify this process, we propose to build a server-based database of pretrained CNN models that is accessed by the user via a web service directly from the data acquisition and analysis software. We demonstrate a working prototype comprised of a shared CNN database containing three material systems. By this, the microscope operator can determine the specimen thickness by PACBED within a few seconds in a reproducible way during a microscope session, without any prior knowledge about machine learning or multislice modeling. Furthermore, the service is integrated into other software and workflows through the API.
- 12 January 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (1) , 427-436
Open AccessOnline Thickness Determination with Position Averaged Convergent Beam Electron Diffraction using Convolutional Neural Networks
Position averaged convergent beam electron diffraction (PACBED) is one of the most convenient and precise thickness determination techniques available in a scanning transmission electron microscope. The thickness is determined by finding the best match of the recorded PACBED pattern with a series of simulated diffraction patterns by visual inspection. The automatization of this process can be enhanced by convolutional neural networks (CNNs), making the method fast and easy to apply. However, the simulation of a synthetic dataset and the training of the CNNs carry a high computational cost. With the aim to simplify this process, we propose to build a server-based database of pretrained CNN models that is accessed by the user via a web service directly from the data acquisition and analysis software. We demonstrate a working prototype comprised of a shared CNN database containing three material systems. By this, the microscope operator can determine the specimen thickness by PACBED within a few seconds in a reproducible way during a microscope session, without any prior knowledge about machine learning or multislice modeling. Furthermore, the service is integrated into other software and workflows through the API.
- Open Access
- 2 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 8 (25730436) , 996-1011
Inverse Multislice Ptychography by Layer-Wise Optimisation and Sparse Matrix Decomposition
We propose algorithms based on an optimisation method for inverse multislice ptychography in, e.g. electron microscopy. The multislice method is widely used to model the interaction between relativistic electrons and thick specimens. Since only the intensity of diffraction patterns can be recorded, the challenge in applying inverse multislice ptychography is to uniquely reconstruct the electrostatic potential in each slice up to some ambiguities. In this conceptual study, we show that a unique separation of atomic layers for simulated data is possible when considering a low acceleration voltage. We also introduce an adaptation for estimating the illuminating probe. For the sake of practical application, we finally present slice reconstructions using experimental 4D scanning transmission electron microscopy (STEM) data.
- 2 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 8 (25730436) , 996-1011
Open AccessInverse Multislice Ptychography by Layer-Wise Optimisation and Sparse Matrix Decomposition
We propose algorithms based on an optimisation method for inverse multislice ptychography in, e.g. electron microscopy. The multislice method is widely used to model the interaction between relativistic electrons and thick specimens. Since only the intensity of diffraction patterns can be recorded, the challenge in applying inverse multislice ptychography is to uniquely reconstruct the electrostatic potential in each slice up to some ambiguities. In this conceptual study, we show that a unique separation of atomic layers for simulated data is possible when considering a low acceleration voltage. We also introduce an adaptation for estimating the illuminating probe. For the sake of practical application, we finally present slice reconstructions using experimental 4D scanning transmission electron microscopy (STEM) data.
- 9 September 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (1) , 408-417
Automatic Alignment of an Orbital Angular Momentum Sorter in a Transmission Electron Microscope Using a Convolutional Neural Network
We report on the automatic alignment of a transmission electron microscope equipped with an orbital angular momentum sorter using a convolutional neural network. The neural network is able to control all relevant parameters of both the electron-optical setup of the microscope and the external voltage source of the sorter without input from the user. It can compensate for mechanical and optical misalignments of the sorter, in order to optimize its spectral resolution. The alignment is completed over a few frames and can be kept stable by making use of the fast fitting time of the neural network.
- 9 September 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (1) , 408-417
Automatic Alignment of an Orbital Angular Momentum Sorter in a Transmission Electron Microscope Using a Convolutional Neural Network
We report on the automatic alignment of a transmission electron microscope equipped with an orbital angular momentum sorter using a convolutional neural network. The neural network is able to control all relevant parameters of both the electron-optical setup of the microscope and the external voltage source of the sorter without input from the user. It can compensate for mechanical and optical misalignments of the sorter, in order to optimize its spectral resolution. The alignment is completed over a few frames and can be kept stable by making use of the fast fitting time of the neural network.
- Open Access
- 22 July 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 28 (S1) , 2958-2960
Ray-Tracing Electrons through a Magnetic Lens
- 22 July 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 28 (S1) , 2958-2960
Open AccessRay-Tracing Electrons through a Magnetic Lens
- Open Access
- 20 June 2020
- Published by The Open Journal in Journal of Open Source Software
- Vol. 5 (50) , 2006
LiberTEM: Software platform for scalable multidimensional data processing in transmission electron microscopy
- 20 June 2020
- Published by The Open Journal in Journal of Open Source Software
- Vol. 5 (50) , 2006
Open AccessLiberTEM: Software platform for scalable multidimensional data processing in transmission electron microscopy