Jingmin Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jingmin Fan has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Anbo Meng
School of Automation, Guangdong University of Technology, Guangzhou, 510006, China
2 shared publications- Junlin Fang
School of Physics and Optoelectric Engineering, Guangdong University of Technology, Guangzhou Higher Education Mega Center 1 , Guangzhou 510006
2 shared publications Qinji Jiang
State Grid Hunan Maintenance Company, Changsha, China
2 shared publications- Qiuqin Sun
Hunan University
2 shared publications - Zhenhua Tang
School of Physics and Optoelectric Engineering, Guangdong University of Technology, Guangzhou Higher Education Mega Center 1 , Guangzhou 510006
2 shared publications Cao Yunfei
Guangdong University of Technology
1 shared publication
Latest Publications
- 4 January 2026
- Published by Springer Nature
- p. 356-363
Application of CEEMDAN-WTD and Gaussian Matching for Denoising and Peak Identification in Transformer Oil Chromatography
- 4 January 2026
- Published by Springer Nature
- p. 356-363
Application of CEEMDAN-WTD and Gaussian Matching for Denoising and Peak Identification in Transformer Oil Chromatography
- 8 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (4) , 5471-5485
A Multilevel Multiphase Single-Stage Switch-Capacitor–Buck DC Transformer for Data Center
Switch-capacitor (SC) based dc transformer is a tendency for voltage regulation in data centers due to bridgeless topology, high voltage gain, and module structure. To achieve high power delivery, SC modules are in multilevel and cascaded with multiphase dc converter. However, the previous high-power SC-based dc transformer is multistage, multilevel, and multiphase structure with massive switches and passive components, causing a large volume and neglecting the characteristics of SC topology. Thus, a multilevel multiphase single-stage switched-capacitor–buck (M2SSCB) dc transformer and its corresponding graph theory-based topology simplification method are proposed in this article. First, the topology evolution based on the graph theory-based topology simplification method is proposed for a cascaded switched-capacitor–buck dc transformer to achieve the simplified M2SSCB dc transformer with fewer electrolytic capacitors and switches as a single-stage converter. Moreover, the proposed M2SSCB dc transformer retains the various switching frequency characteristics in the traditional cascaded switched-capacitor–buck dc transformer and further proposes the dual-frequency operation modes as integer multiple dual-frequency mode and noninteger multiple dual-frequency mode to achieve a wide voltage range. Furthermore, the key parameters design guideline is proposed, and the voltage gain, zero-voltage switching (ZVS), and voltage and current stress of the proposed M2SSCB dc transformer are discussed and presented with fewer switches in a single-stage structure and various switching frequency operation modes for a wide voltage range, ZVS of switches, high voltage gain, and low volume. Finally, an experimental platform is established to verify the correctness and feasibility of the proposed M2SSCB dc transformer. The M2SSCB dc transformer delivers a rated power of 120 W with 48–3.3 V. Besides, it achieves a peak efficiency of 93% and a power density of 93.5 W/in3;. Thus, the proposed M2SSCB dc transformer and its topology simplification method are in line with the development trend of topology single stage.
- 8 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (4) , 5471-5485
A Multilevel Multiphase Single-Stage Switch-Capacitor–Buck DC Transformer for Data Center
Switch-capacitor (SC) based dc transformer is a tendency for voltage regulation in data centers due to bridgeless topology, high voltage gain, and module structure. To achieve high power delivery, SC modules are in multilevel and cascaded with multiphase dc converter. However, the previous high-power SC-based dc transformer is multistage, multilevel, and multiphase structure with massive switches and passive components, causing a large volume and neglecting the characteristics of SC topology. Thus, a multilevel multiphase single-stage switched-capacitor–buck (M2SSCB) dc transformer and its corresponding graph theory-based topology simplification method are proposed in this article. First, the topology evolution based on the graph theory-based topology simplification method is proposed for a cascaded switched-capacitor–buck dc transformer to achieve the simplified M2SSCB dc transformer with fewer electrolytic capacitors and switches as a single-stage converter. Moreover, the proposed M2SSCB dc transformer retains the various switching frequency characteristics in the traditional cascaded switched-capacitor–buck dc transformer and further proposes the dual-frequency operation modes as integer multiple dual-frequency mode and noninteger multiple dual-frequency mode to achieve a wide voltage range. Furthermore, the key parameters design guideline is proposed, and the voltage gain, zero-voltage switching (ZVS), and voltage and current stress of the proposed M2SSCB dc transformer are discussed and presented with fewer switches in a single-stage structure and various switching frequency operation modes for a wide voltage range, ZVS of switches, high voltage gain, and low volume. Finally, an experimental platform is established to verify the correctness and feasibility of the proposed M2SSCB dc transformer. The M2SSCB dc transformer delivers a rated power of 120 W with 48–3.3 V. Besides, it achieves a peak efficiency of 93% and a power density of 93.5 W/in3;. Thus, the proposed M2SSCB dc transformer and its topology simplification method are in line with the development trend of topology single stage.
- 15 September 2023
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 126, 107142
Power transformer fault diagnosis based on a self-strengthening offline pre-training model
- 15 September 2023
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 126, 107142
Power transformer fault diagnosis based on a self-strengthening offline pre-training model
- 24 August 2023
- Published by Springer Nature
- p. 109-120
Prediction of Dissolved Gas Concentration in Transformer Oil Based on WPD-CSO-LSTM Model
- 24 August 2023
- Published by Springer Nature
- p. 109-120
Prediction of Dissolved Gas Concentration in Transformer Oil Based on WPD-CSO-LSTM Model
- 3 August 2023
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 62 (37) , e202308726
An Endogenous Prompting Mechanism for Sulfur Conversions Via Coupling with Polysulfides in Li−S Batteries
The sluggish kinetics process and shuttling of soluble intermediates present in complex conversion between sulfur and lithium sulfide severely limit the practical application of lithium‐sulfur batteries. Herein, by introducing a designated functional organic molecule to couple with polysulfide intermediators, an endogenous prompting mechanism of sulfur conversions has thus been created leading to an alternative sulfur‐electrode process, in another words, to build a fast “internal cycle” of promotors that can promote the slow “external cycle” of sulfur conversions. The coupling‐intermediators between the functional organic molecule and polysulfides, organophosphorus polysulfides, to be the “promotors” for sulfur conversions, are not only insoluble in the electrolyte but also with higher redox‐activity. So the sulfur‐electrode process kinetics is greatly improved and the shuttle effect is eliminated simultaneously by this strategy. Meanwhile, with the endogenous prompting mechanism, the morphology of the final discharge product can be modified into a uniform covering film, which is more conducive to its decomposition when charging. Benefiting from the effective mediation of reaction kinetics and control of intermediates solubility, the lithium‐sulfur batteries can act out excellent rate performance and cycling stability.
- 3 August 2023
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 62 (37) , e202308726
An Endogenous Prompting Mechanism for Sulfur Conversions Via Coupling with Polysulfides in Li−S Batteries
The sluggish kinetics process and shuttling of soluble intermediates present in complex conversion between sulfur and lithium sulfide severely limit the practical application of lithium‐sulfur batteries. Herein, by introducing a designated functional organic molecule to couple with polysulfide intermediators, an endogenous prompting mechanism of sulfur conversions has thus been created leading to an alternative sulfur‐electrode process, in another words, to build a fast “internal cycle” of promotors that can promote the slow “external cycle” of sulfur conversions. The coupling‐intermediators between the functional organic molecule and polysulfides, organophosphorus polysulfides, to be the “promotors” for sulfur conversions, are not only insoluble in the electrolyte but also with higher redox‐activity. So the sulfur‐electrode process kinetics is greatly improved and the shuttle effect is eliminated simultaneously by this strategy. Meanwhile, with the endogenous prompting mechanism, the morphology of the final discharge product can be modified into a uniform covering film, which is more conducive to its decomposition when charging. Benefiting from the effective mediation of reaction kinetics and control of intermediates solubility, the lithium‐sulfur batteries can act out excellent rate performance and cycling stability.
- Open Access
- 24 April 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (17)
Excellent energy storage properties, domain mechanism, and temperature stability of lead-free BaTiO3-Bi(Mg1/2Sn1/2)O3 bulk ferroelectrics
Pulsed power systems require high-performance capacitors with high energy storage density. In this work, (1 − x)BaTiO3-xBi(Mg1/2Sn1/2)O3 ferroelectric ceramics were synthesized in a solid-state solution. The sample of x = 0.12 (0.88BT-0.12BMS) has excellent energy storage density, wide temperature, and wide frequency stability. The excellent energy density of 4.87 J/cm3 at 315 kV/cm and the energy efficiency of 72% at room temperature for 0.88BT-0.12BMS ceramics were achieved. Furthermore, the 0.88BT-0.12BMS ceramics demonstrated well temperature stabilities in the range of 20–100 °C and very good frequency stability in the range of 1–100 Hz. Through pulsed charging–discharging testing, the current density is calculated as 314.01 A/cm2, and the power density is 21.98 MW/cm3. Moreover, the oxygen vacancies' defects and ferroelectric domain mechanism for enhanced breakdown strength as well as high energy density were discussed. These findings broaden the horizon for lead-free dielectrics and show promising applications for pulse power capacitors.
- 24 April 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (17)
Open AccessExcellent energy storage properties, domain mechanism, and temperature stability of lead-free BaTiO3-Bi(Mg1/2Sn1/2)O3 bulk ferroelectrics
Pulsed power systems require high-performance capacitors with high energy storage density. In this work, (1 − x)BaTiO3-xBi(Mg1/2Sn1/2)O3 ferroelectric ceramics were synthesized in a solid-state solution. The sample of x = 0.12 (0.88BT-0.12BMS) has excellent energy storage density, wide temperature, and wide frequency stability. The excellent energy density of 4.87 J/cm3 at 315 kV/cm and the energy efficiency of 72% at room temperature for 0.88BT-0.12BMS ceramics were achieved. Furthermore, the 0.88BT-0.12BMS ceramics demonstrated well temperature stabilities in the range of 20–100 °C and very good frequency stability in the range of 1–100 Hz. Through pulsed charging–discharging testing, the current density is calculated as 314.01 A/cm2, and the power density is 21.98 MW/cm3. Moreover, the oxygen vacancies' defects and ferroelectric domain mechanism for enhanced breakdown strength as well as high energy density were discussed. These findings broaden the horizon for lead-free dielectrics and show promising applications for pulse power capacitors.
- Open Access
- 17 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 16397-16408
Adaptive Modulation Strategy for Modular Multilevel High-Frequency DC Transformer in DC Distribution Networks
The modular multilevel high-frequency DC transformer (MDCT) plays an important role in the bus connection, voltage conversion, power transmission and electrical isolation in the DC distribution networks. During practical operation, the mismatch between high-frequency-link (HFL) voltages and HFL transformer voltage ratio caused by the variation of DC bus voltages occurs, resulting in the increased reactive power, larger current stress and decreased efficiency in MDCT. To solve this problem, an adaptive modulation strategy (AMS) is proposed in this paper. The proposed AMS adjusts HFL voltages by varying the number of inserted sub-modules adaptively, ensuring the HFL voltages match HFL transformer voltage ratio. Compared with the conventional phase-shift strategies, the proposed strategy obtains higher transmission power capacity and HFL power factor, and it maintains the ideal efficiency of MDCT under light load situation. Besides, the proposed strategy avoids the optimal phase-shift angle calculation containing numerous parameters, reducing computing burden and improving practicality for MDCT. Moreover, the hybrid-wave modulation in proposed strategy makes HFL voltages compose of quasi-squarewave and square-wave, addressing the dv/dt stress problem and ensuring the higher DC voltage utilization and power transmission capability simultaneously. The mathematical model, operation principle and control architecture of proposed AMS are investigated, and the experimental results in a MDCT prototype verify the correctness and effectiveness of the analysis and proposed strategy.
- 17 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 16397-16408
Open AccessAdaptive Modulation Strategy for Modular Multilevel High-Frequency DC Transformer in DC Distribution Networks
The modular multilevel high-frequency DC transformer (MDCT) plays an important role in the bus connection, voltage conversion, power transmission and electrical isolation in the DC distribution networks. During practical operation, the mismatch between high-frequency-link (HFL) voltages and HFL transformer voltage ratio caused by the variation of DC bus voltages occurs, resulting in the increased reactive power, larger current stress and decreased efficiency in MDCT. To solve this problem, an adaptive modulation strategy (AMS) is proposed in this paper. The proposed AMS adjusts HFL voltages by varying the number of inserted sub-modules adaptively, ensuring the HFL voltages match HFL transformer voltage ratio. Compared with the conventional phase-shift strategies, the proposed strategy obtains higher transmission power capacity and HFL power factor, and it maintains the ideal efficiency of MDCT under light load situation. Besides, the proposed strategy avoids the optimal phase-shift angle calculation containing numerous parameters, reducing computing burden and improving practicality for MDCT. Moreover, the hybrid-wave modulation in proposed strategy makes HFL voltages compose of quasi-squarewave and square-wave, addressing the dv/dt stress problem and ensuring the higher DC voltage utilization and power transmission capability simultaneously. The mathematical model, operation principle and control architecture of proposed AMS are investigated, and the experimental results in a MDCT prototype verify the correctness and effectiveness of the analysis and proposed strategy.
- 26 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (2) , 648-655
SOFC Detector With OCA Approach to Quantify Trace Gases Dissolved in Transformer Oil
Dissolved gas analysis (DGA) is vital to status evaluation of power transformers. In this study, a solid oxide fuel cell (SOFC) gas sensor was fabricated and applied to DGA. Then, a gas chromatographic system was developed on basis of the SOFC detector. From Nernst function of SOFC, a mathematical model based on oxygen consumption accumulation (OCA) has been proposed to quantify trace gases dissolved in oil. Based on the OCA of SOFC, the gas concentration can be calculated though the chromatogram directly, no calibrating gas is needed, thereby greatly simplifying the quantification process. Following peak detection based on the improved filter matching method, tests were conducted to verify the validity of the OCA method. The experimental results demonstrated that the repeatability represented by relative standard deviation is less than 0.5%; high precision can be achieved, measurement error for five feature gases are less than 10% at given concentrations, providing a competitive performance against other gas sensors with curve fitting method.
- 26 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (2) , 648-655
SOFC Detector With OCA Approach to Quantify Trace Gases Dissolved in Transformer Oil
Dissolved gas analysis (DGA) is vital to status evaluation of power transformers. In this study, a solid oxide fuel cell (SOFC) gas sensor was fabricated and applied to DGA. Then, a gas chromatographic system was developed on basis of the SOFC detector. From Nernst function of SOFC, a mathematical model based on oxygen consumption accumulation (OCA) has been proposed to quantify trace gases dissolved in oil. Based on the OCA of SOFC, the gas concentration can be calculated though the chromatogram directly, no calibrating gas is needed, thereby greatly simplifying the quantification process. Following peak detection based on the improved filter matching method, tests were conducted to verify the validity of the OCA method. The experimental results demonstrated that the repeatability represented by relative standard deviation is less than 0.5%; high precision can be achieved, measurement error for five feature gases are less than 10% at given concentrations, providing a competitive performance against other gas sensors with curve fitting method.
- Open Access
- 17 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 94012-94020
Characteristics of Tin Oxide Chromatographic Detector for Dissolved Gases Analysis of Transformer Oil
The analysis of dissolved gases in insulation oil is of great significance to transformer status evaluation. In this paper, a chromatographic detector based on the nano-tin oxide fiber as well as a chromatography system is developed. The mechanism of the sensor for detecting six component feature gases (i.e., H 2 , CO, CH 4 , C 2 H 4 , C 2 H 6 , and C 2 H 2 ) in transformer oil is expounded, on basis of which the exponent-logarithmic model between conductance and gas concentrations is proposed. Then, the repeatability and accuracy of the nano-tin oxide detectors are tested. The experimental results show that the gases mixture can be separated well by the designed gas chromatography system, and six component gases mixture detection can be realized by the developed detector. Meanwhile, by using the proposed model, high precision of dissolved gas measurement can be achieved, thus the validity of the presented model is verified. Moreover, compared with other chromatographic detectors, i.e., flame ionization detector, the only carrier gas needed for the nano-tin oxide chromatographic detector is the synthetic air, the hardware cost and complexity of system are reduced largely, showing promising applicable value in the engineering practice.
- 17 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 94012-94020
Open AccessCharacteristics of Tin Oxide Chromatographic Detector for Dissolved Gases Analysis of Transformer Oil
The analysis of dissolved gases in insulation oil is of great significance to transformer status evaluation. In this paper, a chromatographic detector based on the nano-tin oxide fiber as well as a chromatography system is developed. The mechanism of the sensor for detecting six component feature gases (i.e., H 2 , CO, CH 4 , C 2 H 4 , C 2 H 6 , and C 2 H 2 ) in transformer oil is expounded, on basis of which the exponent-logarithmic model between conductance and gas concentrations is proposed. Then, the repeatability and accuracy of the nano-tin oxide detectors are tested. The experimental results show that the gases mixture can be separated well by the designed gas chromatography system, and six component gases mixture detection can be realized by the developed detector. Meanwhile, by using the proposed model, high precision of dissolved gas measurement can be achieved, thus the validity of the presented model is verified. Moreover, compared with other chromatographic detectors, i.e., flame ionization detector, the only carrier gas needed for the nano-tin oxide chromatographic detector is the synthetic air, the hardware cost and complexity of system are reduced largely, showing promising applicable value in the engineering practice.