Damian Siedlecki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Damian Siedlecki has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Susana Marcos
Instituto de Óptica “Daza de Valdés” Consejo Superior de Investigaciones Científicas Madrid Spain
8 shared publicationsMarek Zając
7 shared publicationsHenryk Kasprzak
Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, 50-370 Wrocław, Poland
5 shared publicationsJerzy Nowak
Wroclaw Univ. of Technology (Poland)
5 shared publications- Alberto de Castro
Instituto de Óptica “Daza de Valdés,” Consejo Superior de Investigaciones Científicas, Madrid, Spain
4 shared publications - Sergio Ortiz
Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas, C/Serrano 121, 28006 Madrid, Spain
4 shared publications
Latest Publications
- Open Access
- 25 March 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (3) , e0320205
Effect of intraocular pressure on crystalline lens oscillations: a computational study using porcine eye model
This study addresses a crucial knowledge gap by investigating the impact of intraocular pressure (IOP) on the wobbling characteristics of the crystalline lens in an ex vivo setting. It utilizes previous validated computational porcine eye models, which offer anatomical and physiological similarities to the human eye. These models incorporate fluid-structure interaction (FSI) to simulate the mechanical interaction between the fluids of the eye and the solid structures. Simulations were conducted under constant mechanical properties and boundary conditions, allowing for precise quantification of lens wobbling behavior with varying IOP levels. Various trends in lens displacement were observed at various IOP levels, revealing significant variations in both magnitude and duration. The results demonstrate the central role of intraocular pressure in influencing lens overshooting during rotational motion, with potential clinical implications. The observed lens displacement patterns, particularly in conditions like glaucoma, underscore the importance of considering IOP as a critical factor in understanding ocular biomechanics. Beyond immediate biomechanical relevance, the study’s findings suggest the potential use of the Purkinje imaging system as a non-invasive method for IOP estimation based on lens overshoot as an “inverse solution” strategy. This non-invasive imaging technique offers a promising alternative to traditional methods, minimizing patient discomfort and potentially enhancing measurement precision.
- 25 March 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (3) , e0320205
Open AccessEffect of intraocular pressure on crystalline lens oscillations: a computational study using porcine eye model
This study addresses a crucial knowledge gap by investigating the impact of intraocular pressure (IOP) on the wobbling characteristics of the crystalline lens in an ex vivo setting. It utilizes previous validated computational porcine eye models, which offer anatomical and physiological similarities to the human eye. These models incorporate fluid-structure interaction (FSI) to simulate the mechanical interaction between the fluids of the eye and the solid structures. Simulations were conducted under constant mechanical properties and boundary conditions, allowing for precise quantification of lens wobbling behavior with varying IOP levels. Various trends in lens displacement were observed at various IOP levels, revealing significant variations in both magnitude and duration. The results demonstrate the central role of intraocular pressure in influencing lens overshooting during rotational motion, with potential clinical implications. The observed lens displacement patterns, particularly in conditions like glaucoma, underscore the importance of considering IOP as a critical factor in understanding ocular biomechanics. Beyond immediate biomechanical relevance, the study’s findings suggest the potential use of the Purkinje imaging system as a non-invasive method for IOP estimation based on lens overshoot as an “inverse solution” strategy. This non-invasive imaging technique offers a promising alternative to traditional methods, minimizing patient discomfort and potentially enhancing measurement precision.
- Open Access
- 2 May 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (6) , 2465-2477
Complexity of crystalline lens wobbling investigated by means of combined mechanical and optical simulations
Crystalline lens wobbling is a phenomenon when the lens oscillates briefly from its normal position immediately after stopping the rotational movement of the eye globe. It can be observed by means of Purkinje imaging. The aim of this research is to present the data and computation workflow that involve both biomechanical and optical simulations that can mimic this effect, aimed to better understanding of lens wobbling. The methodology described in the study allows to visualize both the dynamic changes of the lens conformation within the eye and its optical effect in terms of Purkinje performance.
- 2 May 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (6) , 2465-2477
Open AccessComplexity of crystalline lens wobbling investigated by means of combined mechanical and optical simulations
Crystalline lens wobbling is a phenomenon when the lens oscillates briefly from its normal position immediately after stopping the rotational movement of the eye globe. It can be observed by means of Purkinje imaging. The aim of this research is to present the data and computation workflow that involve both biomechanical and optical simulations that can mimic this effect, aimed to better understanding of lens wobbling. The methodology described in the study allows to visualize both the dynamic changes of the lens conformation within the eye and its optical effect in terms of Purkinje performance.
- Open Access
- 1 February 2021
- Published by Wiley in Optometry and Vision Science
- Vol. 98 (2) , 127-136
Comparison of Subjective and Objective Methods of Corneoscleral Limbus Identification from Anterior Segment Optical Coherence Tomography Images
Supplemental digital content is available in the text. SIGNIFICANCE: This study evaluates the reliability and validity of an automatic method of the external and internal limbal points identification from anterior segment optical coherence tomography (OCT) images in comparison with manual delineation. PURPOSE: The purpose of this work was to evaluate the repeatability and precision of a previously proposed automatic method of external and internal limbal points identification and to compare them with the manual delineation by experienced clinicians in terms of limbus diameter. METHODS: Optical coherence tomography tomograms obtained for 12 healthy volunteers without a history of eye diseases were analyzed. Fifteen OCT tomograms were captured for each patient. For all the images, the external and internal limbal points were determined using both the automatic and manual methods. The external and internal limbus diameters were used as the comparative parameter between the methods under consideration. The statistical analysis included mean, standard deviation, the Passing‐Bablok regression, and the Pearson correlation coefficient. RESULTS: A strong linear dependence between the automatic and manual methods was identified. While compared with the subjective estimates from clinicians, the automatic technique overestimated the external limbus diameter (bias equals 0.21 mm for optometrist and 0.23 mm for ophthalmologist) and slightly underestimated the internal limbus diameter (bias equals 0.13 mm for optometrist and 0.04 mm for ophthalmologist). The automatic method showed significantly better repeatability than the manual method in the case of external limbal points identification and comparably high repeatability for internal limbal points recognition. CONCLUSIONS: Because of high precision and excellent repeatability, the automatic method of limbal points identification may be successfully used for estimation of the dynamic changes in the geometry of the anterior segment of the eye, where the large number of captured OCT images needs to be processed automatically with high precision.
- 1 February 2021
- Published by Wiley in Optometry and Vision Science
- Vol. 98 (2) , 127-136
Open AccessComparison of Subjective and Objective Methods of Corneoscleral Limbus Identification from Anterior Segment Optical Coherence Tomography Images
Supplemental digital content is available in the text. SIGNIFICANCE: This study evaluates the reliability and validity of an automatic method of the external and internal limbal points identification from anterior segment optical coherence tomography (OCT) images in comparison with manual delineation. PURPOSE: The purpose of this work was to evaluate the repeatability and precision of a previously proposed automatic method of external and internal limbal points identification and to compare them with the manual delineation by experienced clinicians in terms of limbus diameter. METHODS: Optical coherence tomography tomograms obtained for 12 healthy volunteers without a history of eye diseases were analyzed. Fifteen OCT tomograms were captured for each patient. For all the images, the external and internal limbal points were determined using both the automatic and manual methods. The external and internal limbus diameters were used as the comparative parameter between the methods under consideration. The statistical analysis included mean, standard deviation, the Passing‐Bablok regression, and the Pearson correlation coefficient. RESULTS: A strong linear dependence between the automatic and manual methods was identified. While compared with the subjective estimates from clinicians, the automatic technique overestimated the external limbus diameter (bias equals 0.21 mm for optometrist and 0.23 mm for ophthalmologist) and slightly underestimated the internal limbus diameter (bias equals 0.13 mm for optometrist and 0.04 mm for ophthalmologist). The automatic method showed significantly better repeatability than the manual method in the case of external limbal points identification and comparably high repeatability for internal limbal points recognition. CONCLUSIONS: Because of high precision and excellent repeatability, the automatic method of limbal points identification may be successfully used for estimation of the dynamic changes in the geometry of the anterior segment of the eye, where the large number of captured OCT images needs to be processed automatically with high precision.
- Open Access
- 1 April 2020
- Published by Hindawi Limited in Journal of Ophthalmology
- Vol. 2020, 1-3
Personalized Optical Designs and Manipulating Optics: Applications on the Anterior Segment of the Eye
- 1 April 2020
- Published by Hindawi Limited in Journal of Ophthalmology
- Vol. 2020, 1-3
Open AccessPersonalized Optical Designs and Manipulating Optics: Applications on the Anterior Segment of the Eye
- 15 February 2019
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 36 (4) , B28-B34
Non-contact tonometry using Corvis ST: analysis of corneal vibrations and their relation with intraocular pressure
The aim of this study was to determine characteristic frequencies of corneal vibrations occurring during air-puff intraocular pressure (IOP) measurement using the Corvis ST tonometer. Relations of frequency of the corneal vibrations with IOP were examined. Two selected vibration frequencies—frequency with maximum amplitude, and mass center of the frequency distribution area, for which the amplitude was higher than 50% (CM50)—present significant correlations with non-corrected IOP and biomechanical corrected IOP (bIOP). The highest correlation was found between the mean values of CM50 and bIOP (). Based on the results obtained, it can be stated that the vibration frequencies of corneal peaks are closely related to the measured non-corrected and biomechanical corrected IOPs.- 15 February 2019
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 36 (4) , B28-B34
Non-contact tonometry using Corvis ST: analysis of corneal vibrations and their relation with intraocular pressure
The aim of this study was to determine characteristic frequencies of corneal vibrations occurring during air-puff intraocular pressure (IOP) measurement using the Corvis ST tonometer. Relations of frequency of the corneal vibrations with IOP were examined. Two selected vibration frequencies—frequency with maximum amplitude, and mass center of the frequency distribution area, for which the amplitude was higher than 50% (CM50)—present significant correlations with non-corrected IOP and biomechanical corrected IOP (bIOP). The highest correlation was found between the mean values of CM50 and bIOP (). Based on the results obtained, it can be stated that the vibration frequencies of corneal peaks are closely related to the measured non-corrected and biomechanical corrected IOPs.- Open Access
- 1 October 2018
- Published by Photonics Society of Poland in Photonics Letters of Poland
- Vol. 10 (3) , 67-69
Precise geometry of the anterior chamber of the eye by means of OCT imaging.
Nowadays medicine highly relies on non-invasive optical diagnostic methods. The likewise situation is in the case of ophthalmology, especially in diagnosis of anterior segment eye diseases, where optical coherence tomography (OCT) plays inestimable role. OCT devices can do fast, painless measurements of the anterior segment of the eye. Nonetheless it should be remembered that the OCT images are burdened with an optical distortion and they doesn’t reflect the true geometry of the eye. This study presents an algorithm for correcting the distortion in OCT images and reflecting true parameters of the anterior segment of the eye. Full Text: PDF ReferencesA. Podoleanu, I. Charalambous, L. Plesea, A. Dogariu, R. Rosen, "Correction of distortions in optical coherence tomography imaging of the eye", Phys. Med. Biol. 49(7), 1277 (2004). CrossRef S. Ortiz, D. Siedlecki, I. Grulkowski, L. Remon, D. Pascual, M. Wojtkowski, S. Marcos, "Optical distortion correction in Optical Coherence Tomography for quantitative ocular anterior segment by three-dimensional imaging", Opt. Express 18, 2782 (2010). CrossRef F. LaRocca, S.J. Chiu, R.P. McNabb, A.N. Kuo, J.A. Izatt, S. Farsiu, "Robust automatic segmentation of corneal layer boundaries in SDOCT images using graph theory and dynamic programming", Biom. Opt. Express 2(6), 1524 (2011). CrossRef S.A. Read et al., "Anterior eye tissue morphology: Scleral and conjunctival thickness in children and young adults", Sci. Rep. 6, 33796 (2016). CrossRef S.R. Uhlhorn, D. Borja, F. Manns, J.-M. Parel, "Refractive index measurement of the isolated crystalline lens using optical coherence tomography", Vision Res., 48(27), 2732 (2008). CrossRef R. Koprowski, Z. Wróbel, S. Wilczyński, A. Nowińska, E. Wylęgała, "Methods of measuring the iridocorneal angle in tomographic images of the anterior segment of the eye", Biomed. Eng. Online, 12, 40 (2013). CrossRef D.P. Pinero, A.B. Plaza Puche, J.L. Alio, "Corneal diameter measurements by corneal topography and angle-to-angle measurements by optical coherence tomography: Evaluation of equivalence", J. Cataract Refract. Surg. 34, 126 (2008). CrossRef B. Urban, M. Krętowska, M. Szumiński, A. Bakunowicz-Łazarczyk, " Evaluation of anterior chamber depth measurements in emmetropic, hypermetropic and myopic eyes in children and adolescents using OCT Visante", Klinika Oczna 114(1), 18 (2012). DirectLink L. Chen, D. Chernyak, "Pupil Changes under Scotopic and Photopic illumination", Invest. Ophthalmol. Vis. Sci. 54, 1524 (2013). DirectLink D. Monsalvez-Romin, A.J. del Aguila-Carrasco, T. Ferrer-Blasco, J.J. Esteve-Taboada, R Montes-Mico, Evaluation of the iridocorneal angle with accommodation using optical coherence tomography", Int. J. Ophthalmol. 10(10), 1614 (2017). CrossRef
- 1 October 2018
- Published by Photonics Society of Poland in Photonics Letters of Poland
- Vol. 10 (3) , 67-69
Open AccessPrecise geometry of the anterior chamber of the eye by means of OCT imaging.
Nowadays medicine highly relies on non-invasive optical diagnostic methods. The likewise situation is in the case of ophthalmology, especially in diagnosis of anterior segment eye diseases, where optical coherence tomography (OCT) plays inestimable role. OCT devices can do fast, painless measurements of the anterior segment of the eye. Nonetheless it should be remembered that the OCT images are burdened with an optical distortion and they doesn’t reflect the true geometry of the eye. This study presents an algorithm for correcting the distortion in OCT images and reflecting true parameters of the anterior segment of the eye. Full Text: PDF ReferencesA. Podoleanu, I. Charalambous, L. Plesea, A. Dogariu, R. Rosen, "Correction of distortions in optical coherence tomography imaging of the eye", Phys. Med. Biol. 49(7), 1277 (2004). CrossRef S. Ortiz, D. Siedlecki, I. Grulkowski, L. Remon, D. Pascual, M. Wojtkowski, S. Marcos, "Optical distortion correction in Optical Coherence Tomography for quantitative ocular anterior segment by three-dimensional imaging", Opt. Express 18, 2782 (2010). CrossRef F. LaRocca, S.J. Chiu, R.P. McNabb, A.N. Kuo, J.A. Izatt, S. Farsiu, "Robust automatic segmentation of corneal layer boundaries in SDOCT images using graph theory and dynamic programming", Biom. Opt. Express 2(6), 1524 (2011). CrossRef S.A. Read et al., "Anterior eye tissue morphology: Scleral and conjunctival thickness in children and young adults", Sci. Rep. 6, 33796 (2016). CrossRef S.R. Uhlhorn, D. Borja, F. Manns, J.-M. Parel, "Refractive index measurement of the isolated crystalline lens using optical coherence tomography", Vision Res., 48(27), 2732 (2008). CrossRef R. Koprowski, Z. Wróbel, S. Wilczyński, A. Nowińska, E. Wylęgała, "Methods of measuring the iridocorneal angle in tomographic images of the anterior segment of the eye", Biomed. Eng. Online, 12, 40 (2013). CrossRef D.P. Pinero, A.B. Plaza Puche, J.L. Alio, "Corneal diameter measurements by corneal topography and angle-to-angle measurements by optical coherence tomography: Evaluation of equivalence", J. Cataract Refract. Surg. 34, 126 (2008). CrossRef B. Urban, M. Krętowska, M. Szumiński, A. Bakunowicz-Łazarczyk, " Evaluation of anterior chamber depth measurements in emmetropic, hypermetropic and myopic eyes in children and adolescents using OCT Visante", Klinika Oczna 114(1), 18 (2012). DirectLink L. Chen, D. Chernyak, "Pupil Changes under Scotopic and Photopic illumination", Invest. Ophthalmol. Vis. Sci. 54, 1524 (2013). DirectLink D. Monsalvez-Romin, A.J. del Aguila-Carrasco, T. Ferrer-Blasco, J.J. Esteve-Taboada, R Montes-Mico, Evaluation of the iridocorneal angle with accommodation using optical coherence tomography", Int. J. Ophthalmol. 10(10), 1614 (2017). CrossRef
- Open Access
- 5 March 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (03) , 1-10
Influence of material and haptic design on the mechanical stability of intraocular lenses by means of finite-element modeling
The Journal of Biomedical Optics (JBO) publishes peer-reviewed papers on the use of novel optical systems and techniques for improved health care and biomedical research.
- 5 March 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (03) , 1-10
Open AccessInfluence of material and haptic design on the mechanical stability of intraocular lenses by means of finite-element modeling
The Journal of Biomedical Optics (JBO) publishes peer-reviewed papers on the use of novel optical systems and techniques for improved health care and biomedical research.
- Open Access
- 18 October 2015
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-8
Optical Coherence Tomography as a Tool for Ocular Dynamics Estimation
Purpose. The aim of the study is to demonstrate that the ocular dynamics of the anterior chamber of the eye can be estimated quantitatively by means of optical coherence tomography (OCT).Methods. A commercial high speed, high resolution optical coherence tomographer was used. The sequences of tomographic images of the iridocorneal angle of three subjects were captured and each image from the sequence was processed in MATLAB environment in order to detect and identify the contours of the cornea and iris. The data on pulsatile displacements of the cornea and iris and the changes of the depth of the gap between them were retrieved from the sequences. Finally, the spectral analysis of the changes of these parameters was performed.Results. The results of the temporal and spectral analysis manifest the ocular microfluctuation that might be associated with breathing (manifested by 0.25 Hz peak in the power spectra), heart rate (1–1.5 Hz peak), and ocular hemodynamics (3.75–4.5 Hz peak).Conclusions. This paper shows that the optical coherence tomography can be used as a tool for noninvasive estimation of the ocular dynamics of the anterior segment of the eye, but its usability in diagnostics of the ocular hemodynamics needs further investigations.
- 18 October 2015
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-8
Open AccessOptical Coherence Tomography as a Tool for Ocular Dynamics Estimation
Purpose. The aim of the study is to demonstrate that the ocular dynamics of the anterior chamber of the eye can be estimated quantitatively by means of optical coherence tomography (OCT).Methods. A commercial high speed, high resolution optical coherence tomographer was used. The sequences of tomographic images of the iridocorneal angle of three subjects were captured and each image from the sequence was processed in MATLAB environment in order to detect and identify the contours of the cornea and iris. The data on pulsatile displacements of the cornea and iris and the changes of the depth of the gap between them were retrieved from the sequences. Finally, the spectral analysis of the changes of these parameters was performed.Results. The results of the temporal and spectral analysis manifest the ocular microfluctuation that might be associated with breathing (manifested by 0.25 Hz peak in the power spectra), heart rate (1–1.5 Hz peak), and ocular hemodynamics (3.75–4.5 Hz peak).Conclusions. This paper shows that the optical coherence tomography can be used as a tool for noninvasive estimation of the ocular dynamics of the anterior segment of the eye, but its usability in diagnostics of the ocular hemodynamics needs further investigations.