WRWesley Daniel Robertson

Wesley Daniel Robertson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wesley Daniel Robertson has a total of 124 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Characterization of fast ion transport via position-dependent optical deshelving

    by Craig R. Clark, Creston D. Herold, J. True Merrill, Holly N. Tinkey, Wade Rellergert, Robert Clark, Roger Brown, Wesley D. Robertson, Curtis Volin, Kara Maller, et al.

    Ion transport is an essential operation in some models of quantum information processing, where fast ion shuttling with minimal motional excitation is necessary for efficient high-fidelity quantum logic. While fast and cold ion shuttling has been demonstrated, the dynamics and specific trajectory of an ion during diabatic transport have not been studied in detail. Here we describe a position-dependent optical deshelving technique useful for sampling an ion's position throughout its trajectory and we demonstrate the technique on fast linear transport of a 40Ca+ ion in a surface-electrode ion trap. At high speed, the trap's electrode filters strongly distort the transport potential waveform. With this technique, we observe deviations from the intended constant-velocity (100-m/s) transport: We measure an average speed of 82(2) m/s and a peak speed of 251(6) m/s over a distance of 120 µm.


  • Open Access

    Rapid deconvolution of low-resolution time-of-flight data using Bayesian inference

    by Cornelius L. Pieterse, Michiel B. de Kock, Wesley D. Robertson, Hans C. Eggers, R. J. Dwayne Miller

    The deconvolution of low-resolution time-of-flight data has numerous advantages, including the ability to extract additional information from the experimental data. We augment the well-known Lucy-Richardson deconvolution algorithm using various Bayesian prior distributions and show that a prior of second-differences of the signal outperforms the standard Lucy-Richardson algorithm, accelerating the rate of convergence by more than a factor of four, while preserving the peak amplitude ratios of a similar fraction of the total peaks. A novel stopping criterion and boosting mechanism are implemented to ensure that these methods converge to a similar final entropy and local minima are avoided. Improvement by a factor of two in mass resolution allows more accurate quantification of the spectra. The general method is demonstrated in this paper through the deconvolution of fragmentation peaks of the 2,5-dihydroxybenzoic acid matrix and the benzyltriphenylphosphonium thermometer ion, following femtosecond ultraviolet laser desorption.

  • Rapid mixing of colliding picoliter liquid droplets delivered through-space from piezoelectric-actuated pipettes characterized by time-resolved fluorescence monitoring

    by Jamie L. Y. Wu, Friedjof Tellkamp, Mazdak Khajehpour, Wesley D. Robertson, R. J. Dwayne Miller

    Rapid mixing of aqueous solutions is a crucial first step to study the kinetics of fast biochemical reactions with high temporal resolution. Remarkable progress toward this goal has been made through the development of advanced stopped-flow mixing techniques resulting in reduced dead times, and thereby extending reaction monitoring capabilities to numerous biochemical systems. Concurrently, piezoelectric actuators for through-space liquid droplet sample delivery have also been applied in several experimental systems, providing discrete picoliter sample volume delivery and precision sample deposition onto a surface, free of confinement within microfluidic devices, tubing, or other physical constraints. Here, we characterize the inertial mixing kinetics of two aqueous droplets (130 pl) produced by piezoelectric-actuated pipettes, following droplet collision in free space and deposition on a surface in a proof of principle experiment. A time-resolved fluorescence system was developed to monitor the mixing and fluorescence quenching of 5-carboxytetramethylrhodamine (5-Tamra) and N-Bromosuccinimide, which we show to occur in less than 10 ms. In this respect, this methodology is unique in that it offers millisecond mixing capabilities for very small quantities of discrete sample volumes. Furthermore, the use of discrete droplets for sample delivery and mixing in free space provides potential advantages, including the elimination of the requirement for a physical construction as with microfluidic systems, and thereby makes possible and extends the experimental capabilities of many systems.


  • Sampling of Tissues with Laser Ablation for Proteomics: Comparison of Picosecond Infrared Laser and Microsecond Infrared Laser

    by Andrey Krutilin, Stephanie Maier, Raphael Schuster, Sebastian Kruber, Marcel Kwiatkowski, Wesley D. Robertson, Nils-Owe Hansen, R. J. Dwayne Miller, Hartmut Schlüter

    It was recently shown that sampling of tissues with a picosecond infrared laser (PIRL) for analysis with bottom-up proteomics is advantageous compared to mechanical homogenization. Because the cold ablation of tissues with PIRL irradiation is soft, proteins remain intact and even enzymatic activities are detectable in PIRL homogenates. In contrast, it was observed that irradiation of tissues with a microsecond infrared laser (MIRL) heats the tissue, thereby causing significant damage. In this study, we investigated the question if sampling of tissues with a MIRL for analysis of their proteomes via bottom-up proteomics is possible and how the results are different from sampling of tissues with a PIRL. Comparison of the proteomes of the MIRL and PIRL tissue homogenates showed that the yield of proteins identified by bottom-up proteomics was larger in PIRL homogenates of liver tissue, whereas the yield was higher in MIRL homogenates of muscle tissue, which has a significantly higher content of connective tissue than liver tissue. In the PIRL homogenate of renal tissue, enzymatic activities were detectable, whereas in the corresponding MIRL homogenate, enzymatic activities were absent. In conclusion, MIRL and PIRL pulses are suited for sampling tissues for bottom-up proteomics. If it is important for bottom-up proteomic investigations to inactivate enzymatic activities already in the tissue before its ablation, MIRL tissue sampling is an option, because the proteins in the tissues are denatured and inactivated by the heating of the tissue during irradiation with MIRL irradiation prior to the ablation of the tissue. This heating effect is absent during irradiation of tissue with a PIRL; therefore, sampling of tissues with a PIRL is a choice for purifying enzymes, because their activities are maintained.


  • Digital interference microscopy and density reconstruction of picosecond infrared laser desorption at the water-air interface

    by Frederik Busse, Sebastian Kruber, Wesley D. Robertson, R. J. Dwayne Miller

    Material ablation and evaporation using pulsed infrared lasers pose promising approaches for matrix-free laser desorption ionization and in laser surgery. For the best results, key parameters such as laser wavelength, pulse duration, and pulse energy need to be carefully adjusted to the application. We characterize the dynamics at the water-air interface induced by a 10 ps infrared laser tuned to the water absorption band at 3     μ m , a parameter set facilitating stress confined desorption for typical absorption depths in biological samples and tissue. By driving the ablation faster than nucleation growth, cavitation induced sample damage during the ablation process can be mitigated. The resultant explosive ablation process leads to a shock front expansion and material ejection which we capture using off-axis digital interference microscopy, an interference technique particularly useful for detecting the phase shift caused by transparent objects. It is demonstrated that the method can yield local density information of the observed shock front with a single image acquisition as compared to the usually performed fit of the velocity extracted from several consecutive snapshots. We determine the ablation threshold to be ( 0.5 ± 0.2 )   J   cm − 2 and observe a significant distortion of the central parts of the primary shock wave above approximately 2.5     J   cm − 2 . The differences in plume shape observed for higher fluences are reflected in an analysis based on shock wave theory, which shows a very fast initial expansion.


  • Random Laser Physical Unclonable Function

    by David Scrymgeour, Joshua Shank, Bryan James Kaehr, Michael David Henry, Sean Smith, Erik David Spoerke, Jonathan Andreasen, Roger Brown, Wesley Roberston

    We report on the fabrication and characterization of nanocrystalline ZnO films for use as a random laser physical unclonable function (PUF). Correlation between processing conditions and film microstructure will be made to optimize the lasing properties and random response. We will specifically examine the repeatability and security of PUFs demonstrated in this novel 3 system. This demonstration has promise to impact many of Sandia's core missions including counterfeit detection. 4 4

  • Open Access

    Soft Picosecond Infrared Laser Extraction of Highly Charged Proteins and Peptides from Bulk Liquid Water for Mass Spectrometry

    by Yinfei Lu, Cornelius Louwrens Pieterse, Wesley Daniel Robertson, R. J. Dwayne Miller

    We report the soft laser extraction and production of highly charged peptide and protein ions for mass spectrometry directly from bulk liquid water at atmospheric pressure and room temperature, using picosecond infrared laser ablation. Stable ion signal from singly charged small molecules, as well as highly charged biomolecular ions, from aqueous solutions at low laser pulse fluence (~0.3 J cm-2) is demonstrated. Sampling via single picosecond laser pulses is shown to extract less than 27 pL of volume from the sample, producing highly charged peptide and protein ions for mass spectrometry detection. The ablation and ion generation is demonstrated to be soft in nature, producing natively folded proteins ions under sample conditions described for native mass spectrometry. The method provides laser-based sampling flexibility, precision and control with highly charged ion production directly from water at low and near neutral pH. This approach does not require an additional ionization device or high voltage applied directly to the sample.


  • Protein crystals IR laser ablated from aqueous solution at high speed retain their diffractive properties: applications in high-speed serial crystallography

    by Eike C. Schulz, Johannes Kaub, Frederik Busse, Pedram Mehrabi, Henrike M. Müller-Werkmeister, Emil F. Pai, Wesley D. Robertson, R. J. Dwayne Miller

    In order to utilize the high repetition rates now available at X-ray free-electron laser sources for serial crystallography, methods must be developed to softly deliver large numbers of individual microcrystals at high repetition rates and high speeds. Picosecond infrared laser (PIRL) pulses, operating under desorption by impulsive vibrational excitation (DIVE) conditions, selectively excite the OH vibrational stretch of water to directly propel the excited volume at high speed with minimized heating effects, nucleation formation or cavitation-induced shock waves, leaving the analytes intact and undamaged. The soft nature and laser-based sampling flexibility provided by the technique make the PIRL system an interesting crystal delivery approach for serial crystallography. This paper demonstrates that protein crystals extracted directly from aqueous buffer solution via PIRL-DIVE ablation retain their diffractive properties and can be usefully exploited for structure determination at synchrotron sources. The remaining steps to implement the technology for high-speed serial femtosecond crystallography, such as single-crystal localization, high-speed sampling and synchronization, are described. This proof-of-principle experiment demonstrates the viability of a new laser-based high-speed crystal delivery system without the need for liquid-jet injectors or fixed-target mounting solutions.


  • Molecular dynamics investigation of desorption and ion separation following picosecond infrared laser (PIRL) ablation of an ionic aqueous protein solution

    by J. Zou, C. Wu, W. D. Robertson, L. V. Zhigilei, R. J. D. Miller

    Molecular dynamics simulations were performed to characterize the ablation process induced by a picosecond infrared laser (PIRL) operating in the regime of desorption by impulsive vibrational excitation (DIVE) of a model peptide (lysozyme)/counter-ion system in aqueous solution. The simulations were performed for ablation under typical experimental conditions found within a time-of-flight mass spectrometer (TOF-MS), that is in vacuum with an applied electric field (E = ± 107 V/m), for up to 2 ns post-ablation and compared to the standard PIRL-DIVE ablation condition (E = 0 V/m). Further, a simulation of ablation under an extreme field condition (E = 1010 V/m) was performed for comparison to extend the effective dynamic range of the effect of the field on charge separation. The results show that the plume dynamics were retained under a typical TOF-MS condition within the first 1 ns of ablation. Efficient desorption was observed with more than 90% of water molecules interacting with lysozyme stripped off within 1 ns post-ablation. The processes of ablation and desolvation of analytes were shown to be independent of the applied electric field and thus decoupled from the ion separation process. Unlike under the extreme field conditions, the electric field inside a typical TOF-MS was shown to modify the ions’ motion over a longer time and in a soft manner with no enhancement to fragmentation observed as compared to the standard PIRL-DIVE. The study indicates that the PIRL-DIVE ablation mechanism could be used as a new, intrinsically versatile, and highly sensitive ion source for quantitative mass spectrometry.