Vahid Parvin Darabad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vahid Parvin Darabad has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
M. Vakilian
Electrical Engineering Department, Center of Excellence in Power System Management and Control, Sharif University of Technology, Tehran, Iran
3 shared publicationsB. T. Phung
School of Electrical Engineering & Telecommunication, University of New South Wales, Sydney, Australia
2 shared publicationsB.T. Phung
2 shared publicationsT. R. Blackburn
School of Electrical Engineering & Telecommunication, University of New South Wales, Sydney, Australia
2 shared publicationsK. Firuzi
Electrical Engineering Department, Center of Excellence in Power System Management and Control, Sharif University of Technology, Tehran, Iran
1 shared publicationM. Hasanpour
Department of Electrical Engineering, Gorgan Branch, Islamic Azad University, Gorgan, Iran
1 shared publication
Latest Publications
- 29 November 2018
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 26 (6) , 3101-3115
Application of ACF-wavelet feature extraction for classification of some artificial PD models of power transformer
- 29 November 2018
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 26 (6) , 3101-3115
Application of ACF-wavelet feature extraction for classification of some artificial PD models of power transformer
- 13 February 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 28 (7) , e2558
An efficient partial discharge pattern recognition method using texture analysis for transformer defect models
- 13 February 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 28 (7) , e2558
An efficient partial discharge pattern recognition method using texture analysis for transformer defect models
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 24 (6) , 3694-3702
A novel method for differentiating and clustering multiple partial discharge sources using S transform and bag of words feature
Transformers are known as one of the most important equipment in power system transmission and distribution networks. Partial Discharge (PD) measurement and PRPD interpretation is a powerful tool to monitor the situation and evaluating the risk of power transformer failure. Multiple discharge sources affect the accuracy of interpretation of PRPD. This paper presents a PD signal separation algorithm based on extraction of high level image features. The time-frequency S transform (ST) is applied to the PD signal waveforms, acquired by digital detection instruments at 100 MS/s. The resultant ST matrix is then converted to gray scale image from which high level features are extracted using Bag of Words (BoW). Principle component analysis (PCA) transform is applied to BoW feature to reduce the dimension of features. Calinski-Harabasz criterion is calculated to identify the number of active sources and then Gaussian mixture model (GMM) clustering is used to discover clusters in the feature space. The proposed separation algorithm is examined with mixed current impulse signals acquired from PD experiments on artificial multi-defect models. The separation results indicate that the proposed algorithm is effective for identifying the number of active sources and separating mixed PD signals initiated from multiple sources.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 24 (6) , 3694-3702
A novel method for differentiating and clustering multiple partial discharge sources using S transform and bag of words feature
Transformers are known as one of the most important equipment in power system transmission and distribution networks. Partial Discharge (PD) measurement and PRPD interpretation is a powerful tool to monitor the situation and evaluating the risk of power transformer failure. Multiple discharge sources affect the accuracy of interpretation of PRPD. This paper presents a PD signal separation algorithm based on extraction of high level image features. The time-frequency S transform (ST) is applied to the PD signal waveforms, acquired by digital detection instruments at 100 MS/s. The resultant ST matrix is then converted to gray scale image from which high level features are extracted using Bag of Words (BoW). Principle component analysis (PCA) transform is applied to BoW feature to reduce the dimension of features. Calinski-Harabasz criterion is calculated to identify the number of active sources and then Gaussian mixture model (GMM) clustering is used to discover clusters in the feature space. The proposed separation algorithm is examined with mixed current impulse signals acquired from PD experiments on artificial multi-defect models. The separation results indicate that the proposed algorithm is effective for identifying the number of active sources and separating mixed PD signals initiated from multiple sources.
- 1 October 2015
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 71, 373-382
An efficient PD data mining method for power transformer defect models using SOM technique
- 1 October 2015
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 71, 373-382
An efficient PD data mining method for power transformer defect models using SOM technique
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 20 (6) , 2061-2072
An efficient diagnosis method for data mining on single PD pulses of transformer insulation defect models
Reviewing the various Partial Discharges (PD data mining researches which have been reported so far, this study compares the performance of different feature spaces and different classifiers employed for PD classification in insulation condition monitoring of power transformers. In this process, first a knowledge basis is developed through construction of 4 different types of PD models in the high voltage laboratory. Background noise is considered as one class in this knowledge basis. The high frequency time domain current signals of high voltage equipment are captured over one power frequency cycle. The single PD activities within this captured signal are extracted by application of a threshold-based method. Four popular feature extraction methods i.e. Statistical, texture, FFT and Cepstral features are applied on these recorded extracted PD signals. To distinguish the different PD types, three conceptually different classifier types, Neural Network, Decision Tree, and k-nearest neighbours, are applied on the recorded feature spaces. Using Bayesian theory, a performance analysis is carried out to find whether the classifiers are over-fitted or not. Although, the most reliable data mining tool found to be a combination of a Cepstral feature space, and neural network classifier however, since the statistical features can be computed very fast it is employed in this work. Next, it is proposed to use a cascade PD identifier to find whether the detected signal is noise or not. And if it is PD, employing Cepstral feature space knowledge-basis, its type is identified.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 20 (6) , 2061-2072
An efficient diagnosis method for data mining on single PD pulses of transformer insulation defect models
Reviewing the various Partial Discharges (PD data mining researches which have been reported so far, this study compares the performance of different feature spaces and different classifiers employed for PD classification in insulation condition monitoring of power transformers. In this process, first a knowledge basis is developed through construction of 4 different types of PD models in the high voltage laboratory. Background noise is considered as one class in this knowledge basis. The high frequency time domain current signals of high voltage equipment are captured over one power frequency cycle. The single PD activities within this captured signal are extracted by application of a threshold-based method. Four popular feature extraction methods i.e. Statistical, texture, FFT and Cepstral features are applied on these recorded extracted PD signals. To distinguish the different PD types, three conceptually different classifier types, Neural Network, Decision Tree, and k-nearest neighbours, are applied on the recorded feature spaces. Using Bayesian theory, a performance analysis is carried out to find whether the classifiers are over-fitted or not. Although, the most reliable data mining tool found to be a combination of a Cepstral feature space, and neural network classifier however, since the statistical features can be computed very fast it is employed in this work. Next, it is proposed to use a cascade PD identifier to find whether the detected signal is noise or not. And if it is PD, employing Cepstral feature space knowledge-basis, its type is identified.
- 17 February 2012
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 23 (3) , 423-437
Data mining on partial discharge signals of power transformer's defect models
- 17 February 2012
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 23 (3) , 423-437
Data mining on partial discharge signals of power transformer's defect models