Scott J. Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Scott J. Lee has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Perry Joseph Pickhardt
Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, USA
8 shared publications Perry J. Pickhardt
Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
4 shared publications- Ronald M. Summers
Imaging Biomarkers and Computer-Aided Diagnosis Laboratory, Clinical Center, National Institutes of Health, Bethesda, USA
4 shared publications - Timothy J. Ziemlewicz
Department of Radiology, University of Wisconsin, Madison, Wisconsin
4 shared publications Peter M. Graffy
From the Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Science Center, 600 Highland Ave, Madison, WI 53792-3252 (S.J., P.M.G., T.J.Z., S.J.L., P.J.P.); and Department of Diagnostic Radiology, National Institutes of Health Clinical Center, Bethesda, Md (R.M.S.).
3 shared publications- Carlo Nicola De Cecco
Emory University
2 shared publications
Latest Publications
- 1 September 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 320 (3)
Diagnostic Accuracy of Bosniak v2019 for Predicting Cancer and Unfavorable Histology in Class III–IV Cystic Renal Masses
This multicenter multinational study demonstrated that Bosniak classification version 2019 can be used to stratify the probability of cancer and cancer with unfavorable histologic features; nodule size was strongly associated with unfavorable histologic features.
- 1 September 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 320 (3)
Diagnostic Accuracy of Bosniak v2019 for Predicting Cancer and Unfavorable Histology in Class III–IV Cystic Renal Masses
This multicenter multinational study demonstrated that Bosniak classification version 2019 can be used to stratify the probability of cancer and cancer with unfavorable histologic features; nodule size was strongly associated with unfavorable histologic features.
- 1 March 2022
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 4 (2) , e210196
Evaluating the Performance of a Convolutional Neural Network Algorithm for Measuring Thoracic Aortic Diameters in a Heterogeneous Population
“Just Accepted” papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review ...
- 1 March 2022
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 4 (2) , e210196
Evaluating the Performance of a Convolutional Neural Network Algorithm for Measuring Thoracic Aortic Diameters in a Heterogeneous Population
“Just Accepted” papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review ...
- 11 August 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 297 (1) , 64-72
Automated Abdominal CT Imaging Biomarkers for Opportunistic Prediction of Future Major Osteoporotic Fractures in Asymptomatic Adults
Automated bone and muscle imaging biomarkers derived from abdominal CT compared favorably with an established clinical assessment tool for fracture risk for presymptomatic prediction of osteoporoti... Background Body composition data from abdominal CT scans have the potential to opportunistically identify those at risk for future fracture. Purpose To apply automated bone, muscle, and fat tools t...
- 11 August 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 297 (1) , 64-72
Automated Abdominal CT Imaging Biomarkers for Opportunistic Prediction of Future Major Osteoporotic Fractures in Asymptomatic Adults
Automated bone and muscle imaging biomarkers derived from abdominal CT compared favorably with an established clinical assessment tool for fracture risk for presymptomatic prediction of osteoporoti... Background Body composition data from abdominal CT scans have the potential to opportunistically identify those at risk for future fracture. Purpose To apply automated bone, muscle, and fat tools t...
- 1 August 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 129, 109083
Artificial intelligence from A to Z: From neural network to legal framework
- 1 August 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 129, 109083
Artificial intelligence from A to Z: From neural network to legal framework
- Top Cited Papers
- 1 May 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 291 (2) , 360-367
Opportunistic Osteoporosis Screening at Routine Abdominal and Thoracic CT: Normative L1 Trabecular Attenuation Values in More than 20 000 Adults
Our study provides normative values of L1 vertebra trabecular attenuation, which can serve as a quick reference for opportunistic osteoporosis screening at routine CT to identify adults with low bone mineral density who are at risk for osteoporosis, and who could potentially benefit from further evaluation and possible intervention. BackgroundAbdominal and thoracic CT provide a valuable opportunity for osteoporosis screening regardless of the clinical indication for imaging.PurposeTo establish reference normative ranges for first lumbar vertebra (L1) trabecular attenuation values across all adult ages to measure bone mineral density (BMD) at routine CT.Materials and MethodsReference data were constructed from 20 374 abdominal and/or thoracic CT examinations performed at 120 kV. Data were derived from adults (mean age, 60 years ± 12 [standard deviation]; 56.1% [11 428 of 20 374] women). CT examinations were performed with (n = 4263) or without (n = 16 111) intravenous contrast agent administration for a variety of unrelated clinical indications between 2000 and 2018. L1 Hounsfield unit measurement was obtained either with a customized automated tool (n = 11 270) or manually by individual readers (n = 9104). The effects of patient age, sex, contrast agent, and manual region-of-interest versus fully automated L1 Hounsfield unit measurem...
- 1 May 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 291 (2) , 360-367
Top Cited PapersOpportunistic Osteoporosis Screening at Routine Abdominal and Thoracic CT: Normative L1 Trabecular Attenuation Values in More than 20 000 Adults
Our study provides normative values of L1 vertebra trabecular attenuation, which can serve as a quick reference for opportunistic osteoporosis screening at routine CT to identify adults with low bone mineral density who are at risk for osteoporosis, and who could potentially benefit from further evaluation and possible intervention. BackgroundAbdominal and thoracic CT provide a valuable opportunity for osteoporosis screening regardless of the clinical indication for imaging.PurposeTo establish reference normative ranges for first lumbar vertebra (L1) trabecular attenuation values across all adult ages to measure bone mineral density (BMD) at routine CT.Materials and MethodsReference data were constructed from 20 374 abdominal and/or thoracic CT examinations performed at 120 kV. Data were derived from adults (mean age, 60 years ± 12 [standard deviation]; 56.1% [11 428 of 20 374] women). CT examinations were performed with (n = 4263) or without (n = 16 111) intravenous contrast agent administration for a variety of unrelated clinical indications between 2000 and 2018. L1 Hounsfield unit measurement was obtained either with a customized automated tool (n = 11 270) or manually by individual readers (n = 9104). The effects of patient age, sex, contrast agent, and manual region-of-interest versus fully automated L1 Hounsfield unit measurem...
- 1 February 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1094) , 20180726
Population-based opportunistic osteoporosis screening: Validation of a fully automated CT tool for assessing longitudinal BMD changes
Objective:To validate a fully automated CT-based spinal trabecular bone mineral density (BMD) tool and apply it to a longitudinal screening cohort.Methods:The automated BMD tool was retrospectively...
- 1 February 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1094) , 20180726
Population-based opportunistic osteoporosis screening: Validation of a fully automated CT tool for assessing longitudinal BMD changes
Objective:To validate a fully automated CT-based spinal trabecular bone mineral density (BMD) tool and apply it to a longitudinal screening cohort.Methods:The automated BMD tool was retrospectively...
- 28 March 2018
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 91 (1089) , 20170968
Fully automated segmentation and quantification of visceral and subcutaneous fat at abdominal CT: application to a longitudinal adult screening cohort
Objective:To investigate a fully automated CT-based adiposity tool, applying it to a longitudinal adult screening cohort.Methods:A validated automated adipose tissue segmentation algorithm was appl...
- 28 March 2018
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 91 (1089) , 20170968
Fully automated segmentation and quantification of visceral and subcutaneous fat at abdominal CT: application to a longitudinal adult screening cohort
Objective:To investigate a fully automated CT-based adiposity tool, applying it to a longitudinal adult screening cohort.Methods:A validated automated adipose tissue segmentation algorithm was appl...
- 23 March 2018
- Published by Springer Nature in Abdominal Radiology
- Vol. 43 (11) , 2980-2986
Accuracy of liver surface nodularity quantification on MDCT for staging hepatic fibrosis in patients with hepatitis C virus
To evaluate semi-automated measurement of liver surface nodularity (LSN) on MDCT in a cause-specific cohort of patients with chronic hepatitis C virus infection (HCV) for identification of hepatic fibrosis (stages F0–4).
- 23 March 2018
- Published by Springer Nature in Abdominal Radiology
- Vol. 43 (11) , 2980-2986
Accuracy of liver surface nodularity quantification on MDCT for staging hepatic fibrosis in patients with hepatitis C virus
To evaluate semi-automated measurement of liver surface nodularity (LSN) on MDCT in a cause-specific cohort of patients with chronic hepatitis C virus infection (HCV) for identification of hepatic fibrosis (stages F0–4).
- 3 January 2018
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 33 (5) , 860-867
Future Osteoporotic Fracture Risk Related to Lumbar Vertebral Trabecular Attenuation Measured at Routine Body CT
: We sought to determine if vertebral trabecular attenuation values measured on routine body computed tomography (CT) scans obtained for a variety of unrelated indications can predict future osteoporotic fractures at multiple skeletal sites. For this Health Insurance Portability and Accountability Act (HIPAA)-compliant and Institutional Review Board (IRB)-approved retrospective cohort study, trabecular attenuation of the first lumbar vertebra was measured in 1966 consecutive older adults who underwent chest and/or abdominal CT at a single institution over the course of 1 year. New pathologic fragility fractures that occurred after a patient's CT study date were identified through an electronic health record database query using International Classification of Diseases (ICD)-9 codes for vertebral, hip, and extremity fractures. Univariate and multivariate Cox proportional hazards regression were performed to determine the effect of L1 trabecular attenuation on fracture-free survival. Age at CT, sex, and presence of a prior fragility fracture were included as confounders in multivariate survival analysis. Model discriminative capability was assessed through calculation of an optimism-corrected concordance index. A total of 507 patients (mean age 73.4 ± 6.3 years; 277 women, 230 men) were included in the final analysis. The median post-CT follow-up interval was 5.8 years (interquartile range 2.1–11.0 years). Univariate analysis showed that L1 attenuation values ≤90 Hounsfield units (HU) are significantly associated with decreased fracture-free survival (p < 0.001 by log-rank test). After adjusting for age, sex, prior fracture, glucocorticoid use, bisphosphonate use, chronic kidney disease, tobacco use, ethanol abuse, cancer history, and rheumatoid arthritis history, multivariate analysis demonstrated a persistent modest effect of L1 attenuation on fracture-free survival (hazard ratio [HR] = 0.63 per 10-unit increase; 95% confidence interval [CI] 0.47–0.85). The model concordance index was 0.700. Ten-year probabilities for major osteoporosis-related fractures straddled the treatment threshold for most subcohorts over the observed L1 HU range. In conclusion, for patients undergoing body CT scanning for any indication, L1 vertebral trabecular attenuation is a simple measure that, when ≤90 HU, identifies patients with a significant decrease in fracture-free survival. © 2018 American Society for Bone and Mineral Research.
- 3 January 2018
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 33 (5) , 860-867
Future Osteoporotic Fracture Risk Related to Lumbar Vertebral Trabecular Attenuation Measured at Routine Body CT
: We sought to determine if vertebral trabecular attenuation values measured on routine body computed tomography (CT) scans obtained for a variety of unrelated indications can predict future osteoporotic fractures at multiple skeletal sites. For this Health Insurance Portability and Accountability Act (HIPAA)-compliant and Institutional Review Board (IRB)-approved retrospective cohort study, trabecular attenuation of the first lumbar vertebra was measured in 1966 consecutive older adults who underwent chest and/or abdominal CT at a single institution over the course of 1 year. New pathologic fragility fractures that occurred after a patient's CT study date were identified through an electronic health record database query using International Classification of Diseases (ICD)-9 codes for vertebral, hip, and extremity fractures. Univariate and multivariate Cox proportional hazards regression were performed to determine the effect of L1 trabecular attenuation on fracture-free survival. Age at CT, sex, and presence of a prior fragility fracture were included as confounders in multivariate survival analysis. Model discriminative capability was assessed through calculation of an optimism-corrected concordance index. A total of 507 patients (mean age 73.4 ± 6.3 years; 277 women, 230 men) were included in the final analysis. The median post-CT follow-up interval was 5.8 years (interquartile range 2.1–11.0 years). Univariate analysis showed that L1 attenuation values ≤90 Hounsfield units (HU) are significantly associated with decreased fracture-free survival (p < 0.001 by log-rank test). After adjusting for age, sex, prior fracture, glucocorticoid use, bisphosphonate use, chronic kidney disease, tobacco use, ethanol abuse, cancer history, and rheumatoid arthritis history, multivariate analysis demonstrated a persistent modest effect of L1 attenuation on fracture-free survival (hazard ratio [HR] = 0.63 per 10-unit increase; 95% confidence interval [CI] 0.47–0.85). The model concordance index was 0.700. Ten-year probabilities for major osteoporosis-related fractures straddled the treatment threshold for most subcohorts over the observed L1 HU range. In conclusion, for patients undergoing body CT scanning for any indication, L1 vertebral trabecular attenuation is a simple measure that, when ≤90 HU, identifies patients with a significant decrease in fracture-free survival. © 2018 American Society for Bone and Mineral Research.
- 21 November 2017
- Published by Springer Nature in European Radiology
- Vol. 28 (4) , 1520-1528
CT texture features of liver parenchyma for predicting development of metastatic disease and overall survival in patients with colorectal cancer
Objectives To determine if identifiable hepatic textural features are present at abdominal CT in patients with colorectal cancer (CRC) prior to the development of CT-detectable hepatic metastases. Methods Four filtration–histogram texture features (standard deviation, skewness, entropy and kurtosis) were extracted from the liver parenchyma on portal venous phase CT images at staging and post-treatment surveillance. Surveillance scans corresponded to the last scan prior to the development of CT-detectable CRC liver metastases in 29 patients (median time interval, 6 months), and these were compared with interval-matched surveillance scans in 60 CRC patients who did not develop liver metastases. Predictive models of liver metastasis-free survival and overall survival were built using regularised Cox proportional hazards regression. Results Texture features did not significantly differ between cases and controls. For Cox models using all features as predictors, all coefficients were shrunk to zero, suggesting no association between any CT texture features and outcomes. Prognostic indices derived from entropy features at surveillance CT incorrectly classified patients into risk groups for future liver metastases (p < 0.001). Conclusions On surveillance CT scans immediately prior to the development of CRC liver metastases, we found no evidence suggesting that changes in identifiable hepatic texture features were predictive of their development. Key Points • No correlation between liver texture features and metastasis-free survival was observed. • Liver texture features incorrectly classified patients into risk groups for liver metastases. • Standardised texture analysis workflows need to be developed to improve research reproducibility.
- 21 November 2017
- Published by Springer Nature in European Radiology
- Vol. 28 (4) , 1520-1528
CT texture features of liver parenchyma for predicting development of metastatic disease and overall survival in patients with colorectal cancer
Objectives To determine if identifiable hepatic textural features are present at abdominal CT in patients with colorectal cancer (CRC) prior to the development of CT-detectable hepatic metastases. Methods Four filtration–histogram texture features (standard deviation, skewness, entropy and kurtosis) were extracted from the liver parenchyma on portal venous phase CT images at staging and post-treatment surveillance. Surveillance scans corresponded to the last scan prior to the development of CT-detectable CRC liver metastases in 29 patients (median time interval, 6 months), and these were compared with interval-matched surveillance scans in 60 CRC patients who did not develop liver metastases. Predictive models of liver metastasis-free survival and overall survival were built using regularised Cox proportional hazards regression. Results Texture features did not significantly differ between cases and controls. For Cox models using all features as predictors, all coefficients were shrunk to zero, suggesting no association between any CT texture features and outcomes. Prognostic indices derived from entropy features at surveillance CT incorrectly classified patients into risk groups for future liver metastases (p < 0.001). Conclusions On surveillance CT scans immediately prior to the development of CRC liver metastases, we found no evidence suggesting that changes in identifiable hepatic texture features were predictive of their development. Key Points • No correlation between liver texture features and metastasis-free survival was observed. • Liver texture features incorrectly classified patients into risk groups for liver metastases. • Standardised texture analysis workflows need to be developed to improve research reproducibility.